Empowering Scientific Discovery

Beijing Zolix Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelSGM30 Series
Spectral Range200–1150 nm
Optical Resolution<1.6 nm @ 546 nm
Signal-to-Noise Ratio (SNR)300:1 (full signal)
Dynamic Range3000:1
Stray Light<0.3% @ 625 nm
DetectorBack-thinned CCD
A/D Conversion16-bit
Integration Time10 ms – 65 s
Input InterfaceSMA905
Slit Options10, 25, 50, 100, 200 µm
Dark Noise20 RMS counts
Dimensions74 × 69 × 35 mm
Weight211 g
Power Supply500 mA @ 5 VDC
CommunicationUSB 2.0 (plug-and-play, Windows-compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelSGM1700
Spectral Range900–1700 nm
Detector TypeThermoelectrically Cooled InGaAs Linear Array
Optical Resolution<4 nm @ 1181 nm (25 µm slit, 150 g/mm grating @ 1250 nm)
Signal-to-Noise Ratio2000:1 (High Dynamic Range mode), 800:1 (High Sensitivity mode)
Dynamic Range3000:1 (HDR), 1600:1 (HS)
Stray Light<0.3% @ 1350 nm
Integration Time10 ms – 120 s
Dark Noise22 RMS counts (HDR), 40 RMS counts (HS)
LinearityR² > 0.99
A/D Conversion16-bit
Trigger ModesSoftware-triggered & External TTL-triggered
InterfaceUSB 2.0
Power Supply12 VDC, 3 A
Dimensions172 × 118 × 52 mm
Weight1227 g
Detector Cooling−10 °C (stabilized, ambient @ 25 °C)
Input ConnectorSMA 905
Slit Options25 µm (standard), 10 µm / 50 µm (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Spectral Range900–1700 nm
DetectorInGaAs linear array
Optical DesignCzerny-Turner
Resolution~5 nm (SW2870 with 25 µm slit: ~2.5 nm)
A/D Converter16-bit, 15 MHz
CoolingSingle-stage thermoelectric (TEC), ΔT ≈ 25 °C below ambient (e.g., 0 °C at 25 °C ambient)
InterfaceUSB 2.0 (bus-powered)
I/O Ports6 configurable digital I/O lines
Data BufferUp to 4000 spectra (continuous multi-exposure mode)
Onboard MemoryFlash ROM for firmware and calibration data
Fiber CouplingSMA 905
Shutter SupportExternal shutter module compatible for dark reference acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBlue Series
Spectral Range200–1100 nm
DetectorCCD (2048-pixel linear array)
Optical Resolution (FWHM)0.13–6.0 nm (dependent on grating and slit configuration)
Sensitivity100 photons/count at 400 nm
Signal-to-Noise Ratio1000:1 (full well, 1 s integration)
Dynamic Range2000:1 (6 decades)
Stray Light<0.1% at 435 nm
InterfaceUSB 2.0, SMA905 fiber input, 16-bit ADC
Integration Time1 ms – 65 s
Grating Options300–2400 g/mm (holographic & ruled)
Slit Options14–200 µm
Focal Ratiof/4
Optical DesignSymmetric Czerny–Turner with crossed-beam geometry
Power Supply<100 mA via USB port
Dimensions25.4 × 76.2 × 127 mm (1 × 3 × 5 in)
Weight397 g (14 oz)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Detector TypeCMOS
Spectral Range180–1025 nm
Signal-to-Noise Ratio330:1
Detector ModelHamamatsu S11639 (2048-pixel linear CMOS array)
Integration Time0.2 ms to 65 s
A/D Resolution16-bit @ 15 MHz
InterfaceUSB 2.0 (480 Mbps, plug-and-play)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0