- All
- Favorite
- Popular
- Most rated
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CNT-NIR Series |
| Price | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Omni-λ300i |
| Application System | Universal |
| Grating Capacity | Triple-Grating Turret |
| Focal Length | 320 mm |
| Optical Design | Czerny-Turner with Toroidal Imaging Correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Options | Side or Dual Input/Output Configurable |
| Slit | Manual (0.01–3 mm width, 2/4/14 mm height), Motorized Slit Optional |
| Detector Interface | Dual CCD Output Standard |
| Control Interface | USB 2.0 (RS-232 Optional) |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.04–1.28 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.069–3.05 nm |
| Linear Dispersion (@435.83 nm) | 0.91–40.43 nm/mm |
| Scan Range | 0–19,200 nm (grating-dependent) |
| Scan Step | 0.0025–0.08 nm |
| F/# | f/4.2 |
| Image Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Dimensions | 420 × 295 × 232 mm |
| Weight | 16 kg |
| Max Power Consumption | 100 W @ 24 V DC |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Model | LIBS-Multi900 |
| Key Spectral Ranges | 195–1000 nm (combined LIBS + Raman) |
| LIBS Detection Range | 200–900 nm |
| Raman Shift Range | 80–4000 cm⁻¹ |
| Optical Resolution (LIBS) | <0.1 nm (configurable) |
| Time-Gated Detection | Minimum 3 ns, Timing Precision ±10 ps |
| Laser Energy Options | 50 / 100 / 200 / 400 mJ |
| Excitation Wavelength (Raman) | 532 nm |
| Raman Spectral Resolution | 2 cm⁻¹ |
| Vacuum Compatibility | Ultra-High Vacuum (UHV), down to 10⁻⁸ Pa |
| Sample Temperature Range | 4 K to RT |
| XYZ Motorized Stage | Fully Customizable Travel |
| In-Situ Imaging | Long-Working-Distance Microscope with Real-Time Visual Feedback |
| Automated Focus Tracking | Laser- and Vision-Based Surface Topography Compensation |
| Mapping Capability | Co-registered LIBS/Raman point-by-point scanning |
| Software Control | Unified GUI for hardware orchestration, spectral acquisition, peak identification, data export, and database integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FEDU |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 10 cm⁻¹ |
| Minimum Wavenumber | 100 cm⁻¹ |
| Wavenumber Repeatability | ±1 cm⁻¹ |
| Laser Wavelength | 532 nm |
| Laser Power | 50 mW |
| Raman Shift Range | 200–2000 cm⁻¹ |
| Fluorescence Range (optional) | 550–850 nm |
| Optical Resolution | 2 nm |
| Detector | Back-Illuminated CCD |
| Power Supply | 110/220 V AC (12 V @ 4 A DC adapter output) |
| Dimensions | 800 × 400 × 350 mm |
| Weight | <10 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SGM1040-VNIR |
| Price Range | USD 70,000 – 112,000 |
| Wavelength Range | 350–1020 nm |
| Slit Width | 25 µm |
| Optical Resolution (FWHM) | 1.3 nm |
| Detector | Sony ILX554B linear CCD, 2048 pixels |
| Integration Time | 1 ms – 65 s |
| Dynamic Range | 1800:1 |
| Signal-to-Noise Ratio | 200:1 |
| Wavelength Repeatability | ±0.05 nm (100 consecutive measurements, Hg-Ar lamp) |
| Wavelength Accuracy | ±0.3 nm |
| Thermal Drift | <0.04 nm/°C |
| Data Interface | USB 2.0 @ 480 Mbps |
| Fiber Connector | SMA 905 |
| Dimensions | 86 × 110 × 31.4 mm |
| Brand | ZOLIX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Ultrafast Spectroscopy Test System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FinderInsight |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–2000 cm⁻¹ |
| Spectral Resolution | 6–10 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.01 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | OmniFluo960 |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (excitation), 0.023–7 mm (emission) |
| Spectral Resolution | ≤ 0.08 nm |
| Sensitivity | Water Raman Signal-to-Noise Ratio ≥ 10,000:1 (at 350 nm excitation, 370–450 nm scan, 5 nm slit, 1 s integration) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Focal Length | 320 mm |
| Stray Light | ≤ 1×10⁻⁵ |
| Detector Options | CR131 (cooled red-sensitive PMT, 185–900 nm), R928, R13456, H10330C-75, R5509-73 |
| Standard Sample Chamber | SAC-FLS with cuvette, powder & solid sample holders |
| Automated Light Shield | Yes |
| Dark Count | ≤ 100 CPS (at –10°C) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaTracer |
| Imaging Modality | Hyperspectral (Push-broom & Tunable Filter variants) |
| Deployment | Benchtop Laboratory |
| Spectral Range | 250–2500 nm (configurable by variant) |
| Spectral Resolution | 8–20 nm (FWHM, wavelength-dependent) |
| Spatial Resolution | ≤100 µm at 300 mm working distance |
| Field of View (TFOV) | ±7° |
| Instantaneous Field of View (IFOV) | <0.1 mrad |
| Frame Rate | 22–25 fps (GigE data interface) |
| Optical Interface | USB 2.0 (control), GigE (image data) |
| Illumination | Dual 300 W adjustable broadband source (VIS–SWIR), UV optional |
| Sample Stage | Motorized Z-axis (0–800 mm), X/Y translation (300 mm travel), tilt/height-adjustable line source |
| Compliance | Designed for ISO/IEC 17025-aligned forensic laboratories |
| Software | Proprietary acquisition & spectral unmixing suite with spectral library matching and PCA-based anomaly detection |
| Key | Brand: ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | Omni-λ Grating Modules |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Imspector Series |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaField Pro-N17E Lite |
| Operating Principle | Push-broom Scanning |
| Imaging Mode | 3D Spatial-Spectral Cube Acquisition |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Range | 960–1640 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Numerical Aperture | f/2.0 |
| Slit Dimensions | 30 µm × 14.2 mm |
| Detector | InGaAs |
| Spatial × Spectral Pixels | 256 × 320 |
| Spectral Bands | 320 (standard), 160 (binning mode) |
| Dynamic Range | 12-bit |
| Field of View (TFOV) | 12.2° (@ 30 mm lens) |
| Image Spatial Resolution | 256 × 400 pixels per cube |
| Scan Speed | 4 s/cube |
| Weight | 7.5 kg |
| Integrated Battery | 120 Wh (operational duration > 2 h) |
| Connectivity | Wi-Fi (Android/iOS remote control), optional serial RF link for long-range telemetry |
| Data Format | ENVI-compatible BIL/BIP, supports Evince, ENVI, SpecSight, and MATLAB workflows |
| Brand | ZOLIX |
|---|---|
| Model | DPe22 |
| Detector Type | Room-Temperature Pyroelectric Detector |
| Spectral Range | 500 nm – 22 µm |
| Active Area | 0.5 mm × 2 mm |
| Window Material | ZnSe (standard) |
| Responsivity @ 500 Hz, 12.5 µm | 2×10⁵ V/W |
| Specific Detectivity D* @ 500 Hz, 12.5 µm | 1×10⁹ cm·Hz¹ᐟ²/W |
| NEP @ 500 Hz, 12.5 µm | 9×10⁻¹¹ W/Hz¹ᐟ² |
| Max. Incident Power | 1 µW |
| Max. Output Voltage | 4 V |
| Output Mode | Voltage |
| Polarity | Positive (P) |
| Recommended Modulation Frequency | ~70 Hz |
| Pre-amplifier Integrated | Yes |
| Sensing Element | LATGS Crystal |
| Structural Design | Thermocouple-inspired architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Czerny-Turner grating monochromator with 1800 lines/mm grating |
| Optical System | Single-beam |
| Background Correction | Deuterium lamp + Self-reversal (Self-absorption) background correction |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (5-step automatic switching) |
| Cu Detection Limit (Flame) | ≤0.003 µg/mL |
| Cd Characteristic Mass (GFAAS) | 0.3×10⁻¹² g |
| Cd Detection Limit (GFAAS) | 0.2×10⁻¹² g |
| Graphite Furnace Temp. Range | Room temperature to 3000 °C |
| Max. Sample Volume (GFAAS) | 70 µL |
| Background Correction Capacity | >60× at up to 1.0 A absorbance |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SGM30 Series |
| Spectral Range | 200–1150 nm |
| Optical Resolution | <1.6 nm @ 546 nm |
| Signal-to-Noise Ratio (SNR) | 300:1 (full signal) |
| Dynamic Range | 3000:1 |
| Stray Light | <0.3% @ 625 nm |
| Detector | Back-thinned CCD |
| A/D Conversion | 16-bit |
| Integration Time | 10 ms – 65 s |
| Input Interface | SMA905 |
| Slit Options | 10, 25, 50, 100, 200 µm |
| Dark Noise | 20 RMS counts |
| Dimensions | 74 × 69 × 35 mm |
| Weight | 211 g |
| Power Supply | 500 mA @ 5 VDC |
| Communication | USB 2.0 (plug-and-play, Windows-compatible) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder One |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–5,000 cm⁻¹ |
| Spectral Resolution | <3 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DSR100 |
| Pricing | Upon Request |
| Wavelength Range | 200–2500 nm (UV-VIS-NIR) / 1–14 µm (MIR-FIR) |
| Beam Type | Uniform Collimated or Focused |
| Beam Diameter | Ø2–20 mm (collimated), Ø0.3–3 mm (focused) |
| Light Source | Deuterium + Tungsten-Halogen (UV-A/VIS-NIR) / Tungsten-Halogen + SiC (MIR-FIR) |
| Intensity Stability | ≤0.8% (UV-A/VIS-NIR), ≤2% (MIR-FIR) |
| Monochromator | Triple-Grating, Resolution: <0.1 nm @ 435.8 nm (1200 g/mm grating), <2.5 nm @ 2615 nm (75 g/mm grating) |
| Scan Step | Down to 0.005 nm |
| Output Bandwidth | <5 nm (UV-VIS-NIR), <10 nm (MIR-FIR) |
| Stray Light Suppression | Motorized Filter Wheel with Order-Sorting Filters |
| Modulation Frequency | 4–400 Hz |
| Detection | Lock-in Amplifier (2 nV sensitivity, 100 dB dynamic range) |
| Reference Detectors | NIST-traceable Si photodiode (200–1100 nm), Pyroelectric detector (1–14 µm) |
| Repeatability | ≤±1.5% (UV-VIS-NIR), ≤±5% (MIR-FIR) |
| Optical Center Height | 305 mm |
| System Dimensions | 1500 × 1200 × 560 mm |
| Control Enclosure | Standard 4U rack-mount cabinet with embedded industrial PC |
| Origin | Israel |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PD10 |
| Pricing | Available Upon Request |
| Measurement Principle | Photodiode-based Pulse Energy Detection |
| Max Repetition Rate | 10 kHz |
| Energy Range | 2 nJ – 20 µJ |
| Spectral Range | 190–1100 nm |
| Active Area | Ø10 mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-LIBS Integrated LIBS System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | CCD Interface Flange |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SmartFluo-Pro |
| Price | USD 25,000 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Spectral Resolution | 5 nm |
| Detection Limit | <0.1 µg/L quinine sulfate in 0.1 mol/L H₂SO₄ |
| Wavelength Accuracy | ±1 nm |
| Excitation Range | 200–800 nm |
| Emission Range | 200–800 nm |
| Excitation Monochromator | 200 mm focal length, Czerny–Turner configuration, low stray light design |
| Grating Density | 1800 grooves/mm @ 400 nm |
| Wavelength Repeatability | ±0.5 nm |
| Integration Time | 100 µs to 24 s |
| Standard Sample Holder | Quartz cuvette (10 mm path length) |
| Dimensions (L×H×W) | 620 × 415 × 300 mm |
| Weight | 25 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Spectral Angular Distribution System |
| Wavelength Range | 200 nm – IR |
| Angular Positioning Repeatability | ±0.005° |
| Angular Resolution | 0.00125° |
| Optional Functionality | Diffraction Efficiency Measurement of Gratings |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Product Type | Spectroscopy Instrument Control Software |
| Model | SpectraScan (Accessory Software Suite) |
| Compliance | Designed for ZOLIX omni-λ Series Monochromators & ZOLIX CCD Detectors |
| Interface | USB 2.0 / USB 3.0 |
| Supported Operating Systems | Windows 10/11 (64-bit) |
| Data Export Formats | CSV, TXT, ASCII, PNG, TIFF |
| Calibration Support | Wavelength & Intensity Calibration via NIST-traceable standards |
| Software Architecture | Native C++ with multi-threaded acquisition engine |
| Audit Trail | Optional GLP-compliant logging module (configurable) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | SGM1700 |
| Spectral Range | 900–1700 nm |
| Detector Type | Thermoelectrically Cooled InGaAs Linear Array |
| Optical Resolution | <4 nm @ 1181 nm (25 µm slit, 150 g/mm grating @ 1250 nm) |
| Signal-to-Noise Ratio | 2000:1 (High Dynamic Range mode), 800:1 (High Sensitivity mode) |
| Dynamic Range | 3000:1 (HDR), 1600:1 (HS) |
| Stray Light | <0.3% @ 1350 nm |
| Integration Time | 10 ms – 120 s |
| Dark Noise | 22 RMS counts (HDR), 40 RMS counts (HS) |
| Linearity | R² > 0.99 |
| A/D Conversion | 16-bit |
| Trigger Modes | Software-triggered & External TTL-triggered |
| Interface | USB 2.0 |
| Power Supply | 12 VDC, 3 A |
| Dimensions | 172 × 118 × 52 mm |
| Weight | 1227 g |
| Detector Cooling | −10 °C (stabilized, ambient @ 25 °C) |
| Input Connector | SMA 905 |
| Slit Options | 25 µm (standard), 10 µm / 50 µm (optional) |
Show next