| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CNT-NIR Series |
| Price | Upon Request |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaTracer |
| Imaging Modality | Hyperspectral (Push-broom & Tunable Filter variants) |
| Deployment | Benchtop Laboratory |
| Spectral Range | 250–2500 nm (configurable by variant) |
| Spectral Resolution | 8–20 nm (FWHM, wavelength-dependent) |
| Spatial Resolution | ≤100 µm at 300 mm working distance |
| Field of View (TFOV) | ±7° |
| Instantaneous Field of View (IFOV) | <0.1 mrad |
| Frame Rate | 22–25 fps (GigE data interface) |
| Optical Interface | USB 2.0 (control), GigE (image data) |
| Illumination | Dual 300 W adjustable broadband source (VIS–SWIR), UV optional |
| Sample Stage | Motorized Z-axis (0–800 mm), X/Y translation (300 mm travel), tilt/height-adjustable line source |
| Compliance | Designed for ISO/IEC 17025-aligned forensic laboratories |
| Software | Proprietary acquisition & spectral unmixing suite with spectral library matching and PCA-based anomaly detection |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Imspector Series |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaField Pro-N17E Lite |
| Operating Principle | Push-broom Scanning |
| Imaging Mode | 3D Spatial-Spectral Cube Acquisition |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Range | 960–1640 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Numerical Aperture | f/2.0 |
| Slit Dimensions | 30 µm × 14.2 mm |
| Detector | InGaAs |
| Spatial × Spectral Pixels | 256 × 320 |
| Spectral Bands | 320 (standard), 160 (binning mode) |
| Dynamic Range | 12-bit |
| Field of View (TFOV) | 12.2° (@ 30 mm lens) |
| Image Spatial Resolution | 256 × 400 pixels per cube |
| Scan Speed | 4 s/cube |
| Weight | 7.5 kg |
| Integrated Battery | 120 Wh (operational duration > 2 h) |
| Connectivity | Wi-Fi (Android/iOS remote control), optional serial RF link for long-range telemetry |
| Data Format | ENVI-compatible BIL/BIP, supports Evince, ENVI, SpecSight, and MATLAB workflows |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | AISA Eagle, AISA Hawk, AISA Dual |
| Spectral Range | 400–970 nm (Eagle), 970–2450 nm (Hawk), 400–2450 nm (Dual) |
| Spatial Pixels | 512 or 1024 (Eagle), 320 (Hawk and Dual) |
| Spectral Bands | 488 (Eagle), 256 (Hawk), 500 (Dual) |
| Frame Rate | 160 Hz (Eagle), 100 Hz (Hawk and Dual) |
| Weight | < 12 kg (system total) |
| Integration | GPS/INS-aided georeferencing module included |
| Data Acquisition | Real-time onboard storage with lossless compression |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ArtScanner |
| Pricing | Available Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MicroHSImager |
| Pricing | Available Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N25E-SWIR |
| Price | Upon Request |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 10 nm |
| Spectral Sampling Interval | 6.3 nm |
| Effective Slit Length | 9.6 mm |
| Optical Throughput Efficiency | >50% |
| Relative Aperture | f/2.0 |
| Slit Width | 30 µm |
| Stray Light Level | 0.5% |
| Detector Type | Mercury Cadmium Telluride (MCT) |
| Detector Cooling | Thermoelectric (TE) |
| Full-Frame Pixel Count | 320 × 256 (240 active rows) |
| Pixel Size | 30 × 30 µm |
| A/D Output | 14-bit |
| Dynamic Range | 800:1 |
| Frame Rate (Full Frame) | 100 fps |
| Exposure Time Range | 0.1–20 ms |
| Computer Interface | LVDS |
| Lens Mount | C-Mount |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSHyperSIS-VNIR |
| Price Range | USD 14,000 – 43,000 (FOB) |
| Operating Principle | Push-broom scanning |
| Imaging Mode | 3D spatial-spectral data cube acquisition |
| Deployment Platform | Terrestrial (ground-based) |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 0.025 nm (FWHM) |
| Spatial Resolution | 1392 × 1040 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.05° |
| Frame Rate | 25–120 fps |
| Standard Lens Focal Length | 17 mm |
| Vertical FOV | 40° |
| Horizontal FOV | 70° |
| Scan Speed | ≤100 images/s (CCD-dependent) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaMicro-G |
| Spectral Range | 400–1000 nm (Visible-NIR) / 900–1700 nm (NIR) |
| Spectral Resolution | 2.8–5.0 nm |
| Spatial Resolution | Configurable via interchangeable infinity-corrected objectives (5×–100×) |
| Numerical Aperture | F/2.0–F/2.8 |
| Detector | CCD / sCMOS / InGaAs |
| Pixel Array | Up to 2048 × 2048 (spatial × spectral) |
| Bit Depth | 14–16 bits |
| Interface | USB 2.0 / USB 3.0 / GigE |
| Imaging Mode | Push-broom scanning with motorized XY stage |
| FOV & IFOV | Objective-dependent (e.g., 10× objective: ~1.0 mm FOV, ~0.5 µm IFOV at diffraction limit) |
| Frame Rate | Variable (up to 60 fps for snapshot LCTF variants |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaField-V10E |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | <3 nm |
| Spatial Resolution (IFOV) | <0.1° |
| Field of View (TFOV) | 20° |
| Image Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Scanning Mechanism | Optomechanical Push-broom with Motorized Horizontal Scan (±22.5°, 45° total) |
| Detector Type | Uncooled CCD |
| Pixel Size | 6.45 × 6.45 µm |
| A/D Depth | 14-bit |
| Dynamic Range | 60 dB |
| Optical Interface | C-Mount |
| Lens Focal Length | 25 mm |
| f-number | F/2.4 (spectrometer), F/1.4–F/17 (lens) |
| Total Optical Throughput | >50% |
| Stray Light | <0.5% |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| System Weight | 8 kg |
| Form Factor | Hand-carried integrated unit |
| Data Output Format | Standard raw binary cube (.raw) compatible with ENVI, Specim IQ, and MATLAB |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MICROXCAM |
| Imaging Modality | 3D Hyperspectral Imaging |
| Platform Compatibility | Ground-based & Airborne Deployment |
| Spectral Range | 500–1450 cm⁻¹ (7–20 µm) |
| Detector Technology | Uncooled Microbolometer Array with Gold-Black Broadband Absorber |
| Spectral Resolution | <16 cm⁻¹ (typical, configurable via integrated MEMS Fabry–Pérot tunable filter) |
| Spatial Resolution | ≤ 1.5 mrad IFOV (dependent on lens focal length and working distance) |
| Field of View (TFOV) | 12° × 9° (standard lens) |
| Frame Rate | Up to 25 Hz full-frame spectral cube acquisition |
| Data Output Format | Standard ENVI-compatible .hdr/.dat, IEEE 754 float32 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GaiaGeo |
| Pricing | Upon Request |
| Spectral Range | 970–2500 nm (400–970 nm optional) |
| Spectral Channels | 256 (continuous, at 970–2500 nm) |
| Spatial Resolution | 0.2–2 mm |
| Spatial Pixels per Line | 320 |
| Max Scan Speed | 100 lines/sec (e.g., 20 mm/sec at 0.2 mm pixel size |
| Data Format | BIL (ENVI-compatible) |
| Calibration | Factory spectral calibration |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GaiaSorter-Dual |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm |
| Spatial Resolution (IFOV) | 30 µm and 50 µm |
| Field of View (TFOV) | 20° |
| Imaging Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Imaging Modality | 3D Scanning |
| Operational Mode | Airborne-Compatible Benchtop Configuration |
| Power Input | AC 220 V ±10% / DC 12 V |
| Total System Power Consumption | ~500 W |
| Sample Chamber Max Dimensions | 300 × 300 × 100 mm |
| Working Distance Adjustment Range | 100–600 mm |
| Scan Travel | 800 mm |
| Output Interfaces | USB, Ethernet, RS-232 |
| Brand | ZOLIX |
|---|---|
| Model | iTracer |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Operating Principle | Whiskbroom Scanning |
| Imaging Modality | 3D Hyperspectral Cubes |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Ranges | 200–400 nm, 380–800 nm, 400–1000 nm, 900–1700 nm, 1000–2500 nm |
| Spectral Resolution | 0.01 nm |
| Spatial Resolution | 1280 × 1024 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.1 mrad |
| Frame Rate | 5 fps |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics |
| Type | GaiaSorter |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm (at VNIR band) |
| Spatial Resolution (IFOV) | 30 µm / 50 µm |
| Imaging Resolution | 1392 × 1040 pixels |
| Field of View (TFOV) | 20° |
| Frame Rate | 25–120 fps |
| Imaging Mode | Push-broom Hyperspectral Scanning |
| Deployment | Ground-based & Airborne Compatible |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments and industrial QA/QC workflows |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-Imager |
| Price Range | USD 70,000 – 140,000 |
| Operating Principle | Push-broom scanning |
| Imaging Method | Filter-based |
| Deployment Mode | Ground-based and airborne compatible |
| Spectral Resolution | 2.8 nm @ 30 µm slit, 2 nm @ 18 µm slit |
| Detector Types | CCD (1392×1040), sCMOS (2048×2048), EMCCD (512×512), InGaAs (320×256 / 640×512) |
| Spectral Ranges | 400–1000 nm (Vis-NIR), 900–1700 nm (NIR) |
| Numerical Aperture | f/2.4 (Vis-NIR), f/2.0 (NIR) |
| Slit Dimensions | 30 µm × 14.2 mm (standard), 18 µm × 14.2 mm (optional) |
| Data Depth | 12-bit / 16-bit |
| Interface | USB 2.0 / USB 3.0 |
| Lens Mount | C-mount |
| Cooling | Air-cooled to −0 °C (CCD/sCMOS), TE-cooled to −80 °C (EMCCD), TE3-cooled (InGaAs) |
| Software | Proprietary acquisition & analysis suite with ENVI/Evince/SpecSight export compatibility |
| Optional Onboard Processing | Intel Core i7, 16 GB RAM, 256 GB SSD |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaArtScanner |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GaiaChem |
| Pricing | Upon Request |
| Operating Mode | Push-broom Scanning |
| Spectral Range (nm) | 900–1700 (NIR) / 970–2500 (SWIR) |
| Spectral Resolution (nm) | 6 (NIR) / 10 (SWIR) |
| Spectral Bands | 256 |
| Spatial Pixels per Line | 320 |
| Spatial Resolution (µm) | 30–300 |
| Scan Range (mm) | 10–100 |
| Max Sample Dimensions (mm) | 100 × 100 × 40 (W × L × T) |
| Max Scan Speed | 100 hyperspectral line images/s |
| Typical Acquisition Time | 3–10 s (320 × 320 spatial pixels, 256 bands) |
| Illumination Source | SPECIM Diffused Line Illumination Unit |
| Data Format | BIL (Band Interleaved by Line), ENVI & Evince Compatible |
| Spectral Calibration | Factory-performed |
| Reflectance Intensity Calibration | Auto-compensated per scan using internal reference tile |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaSky-mini2-VN |
| Imaging Principle | Push-broom scanning |
| Platform Compatibility | Rotary-wing UAVs (e.g., DJI M600 Pro, S1000+), airships, helicopters |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm (at 30 µm slit width) |
| Numerical Aperture | f/2.8 |
| Sensor | Sony ICX674 CCD |
| Pixel Pitch | 4.54 µm |
| Output Bit Depth | 14-bit |
| Interface | USB 3.0 |
| Operating Voltage | 12–19 V DC |
| Power Consumption | 45 W |
| Image Resolution | 960 × 1040 pixels |
| Spatial Sampling (IFOV) | 0.16 m @ 300 m AGL, 17 mm lens |
| Horizontal FOV | 28.7° (@17 mm), 26.7° (@18.5 mm), 21.5° (@23 mm) |
| Ground Coverage Width | 154 m (@17 mm, 300 m) |
| Scan Rate | 160 line images/s |
| Weight | 1.5 kg (integrated camera + controller) |
| Storage | 240 GB SSD |
| Mounting Envelope | ≥330 × 200 × 260 mm (H×W×D) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Model | GaiaField |
| Operating Principle | Push-broom |
| Imaging Mode | 3D spatial-spectral data cube |
| Deployment | Ground-based |
| Spectral Range | 400–1000 nm (visible to near-infrared) |
| Spectral Resolution | <3 nm (VIS), ≤5 nm (NIR) |
| Spatial Resolution (IFOV) | Configurable via interchangeable lenses |
| Field of View (TFOV) | Lens-dependent |
| Frame Rate | Up to 120 fps (at full resolution, system-limited) |
| Battery Life | >4 hours continuous operation |
| Environmental Rating | IP5X dust resistant, IP1X water resistant |
| Interface | USB 3.0 |
| Data Format | ENVI-compatible BIL/BIP, TIFF, and raw binary |
| OS Compatibility | Windows 7/8/10 (32- & 64-bit) |
| Calibration | Radiometric, reflectance, flat-field, lens distortion, and non-uniformity correction |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thomson Scattering Spectroscopic Diagnostic System |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | ImSpector |
| Spectral Range (Standard Config) | 380–800 nm (V8) / 400–1000 nm (V10) |
| Slit Width | 50 µm (25/80/150 µm optional) |
| Slit Length | 9.6–9.8 mm |
| Relative Aperture | f/2.8 |
| Optical Design | Transmissive Grating-Based Push-Broom Imaging |
| Image Plane Size | 4.3 × 6.6 mm or 6.6 × 8.8 mm |
| Spatial Resolution | <30 µm RMS (V8), <40 µm RMS (V10) |
| Spectral Resolution | 6–11.2 nm |
| Stray Light | <0.5% |
| Throughput Efficiency | >50% |
| Housing Material | Anodized Aluminum |
| Dimensions | Ø35 × 139 mm |
| Weight | 300 g |
| Interface | Standard C-Mount |
| Optical Aberration Control | Optimized for minimal astigmatism, pincushion (<30–45 µm), and trapezoidal distortion (<20–40 µm) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Model | Iris-V / Iris-SN / Iris-N |
| Type | Filter-Based Hyperspectral Imaging Module |
| Spectral Range | 400–720 nm (Iris-V), 550–1000 nm (Iris-SN), 900–1700 nm (Iris-N) |
| FWHM Bandwidth | 8–20 nm (customizable), e.g., 8 nm @ 550 nm (Iris-V/Iris-SN), 20 nm @ 900 nm (Iris-N) |
| Tuning Resolution | ≥1 nm |
| Aperture | 28 mm (standard), customizable up to 48 mm |
| Acceptance Angle | ±8° (Iris-V/Iris-SN), ±10° (Iris-N) |
| Switching Time | 50–150 ms |
| Wavelength Accuracy | FWHM/8 ± 0.5 nm |
| Operating Temperature | −10 to +40 °C |
| Storage Temperature | −20 to +80 °C |
| Power Supply | DC 5 V @ 8 A |
| Polarization Sensitivity | Transmission doubles under linearly polarized illumination vs. unpolarized (reference condition) |