Empowering Scientific Discovery

Beijing Zolix Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
ModelHelios
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelSCS10-Film
PricingUpon Request
Spectral Range300–1700 nm
Wavelength Accuracy±0.2 nm (@ 1200 g/mm grating, 500 nm)
Scan Interval0.1–10 nm (default 10 nm)
Bandwidth0.1–10 nm (default 5 nm)
Light Source150 W stabilized xenon lamp (optical stability ≤0.4%)
Modulation Frequency4–400 Hz
DetectorCalibrated Si photodiode
DC Sensitivity100 nA
AC Sensitivity2 nV
Repeatability<0.6% (<0.3% from 400–1000 nm)
Scan Speed<1 min per spectral response curve
Sample Stage156 mm × 156 mm probe station (customizable)
max sample area300 mm × 300 mm
Mapping Resolution0.5 mm
Mapping Speed20 points/s (@ 0.5 mm step)
Instrument DimensionsHost unit: unspecified
Sample chamberunspecified
Control cabinet800 mm × 600 mm × 1300 mm
SoftwareWindows 7-based proprietary control & analysis suite with calibration traceability
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelLensMechanix
Price RangeUSD 7,000 – 14,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelSGM100
PricingUpon Request
Focal Length100 mm
f-numberf/3
Optical LayoutCrossed Czerny–Turner
Spectral Range200–1100 nm
Stray Light<0.1%
Detector3648-pixel linear CCD array
Spectral Resolution (FWHM)0.05–18.8 nm (configurable via grating and slit selection)
Sensitivity20,000 counts/µW·ms
Signal-to-Noise Ratio300:1
A/D Resolution16-bit
Integration Time7 ms – 65,535 ms
InterfaceUSB 2.0 (8 Mbps), DB-15 I/O (4-in / 4-out)
Power SupplyUSB 5 V DC or external adapter with buck-boost regulation
EMI ShieldingIntegrated RF/EMI-optimized enclosure
Mechanical ConstructionMonolithic aluminum housing
Internal Calibration StorageHigh-capacity flash memory for wavelength calibration, radiometric correction, and colorimetric coefficients
Onboard ProcessingHigh-performance embedded CPU for real-time spectral preprocessing and color space conversion
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelOpticStudio 2017
Price RangeUSD $7,200 – $14,400 (based on perpetual license tiers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelZAMP
TypeTransimpedance (Current-to-Voltage) Amplifier
Input Impedance Range1 mΩ to 100 GΩ (8 decades)
Gain Range10³–10¹⁰ V/A
Output Noise Voltage≤ 0.5 mV (RMS, DC–10 kHz)
Input Current Range±5 mA
Output Voltage Range±5 V
Gain Accuracy±2% (10³–10⁸), ±5% (10⁹–10¹⁰)
Power SupplyDedicated AC adapter (ZAMP-A)
Dimensions195 × 121 × 88 mm
ComplianceCE-marked, RoHS-compliant, designed for laboratory-grade optical signal conditioning in accordance with IEC 61326-1 (EMC for measurement equipment)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelDCS200PC
Counting Rate100 Mcps
Analog Input Channels4 (0–10 V, 16-bit A/D, 1 MS/s per channel)
Analog Output Channels2 (0–10 V)
InterfaceUSB 2.0
CertificationCE
Power SupplyDC 24 V, 0.3 A
Dimensions240 × 240 × 120 mm
Weight3.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginFrance
Sensor TypePhotodiode-based
Max Continuous Power3 W (with built-in attenuator)
Power Range10 pW – 3 W
Wavelength Range190–1100 nm
Linearity±0.5% (up to 2 mW), ±1% (with attenuator, up to 3 W)
Damage Threshold10 W/cm² (CW), 0.1 J/cm² (pulsed, 10 ns)
Output SignalAnalog voltage (1 V per 1 W typical)
ConnectorBNC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelCHAMELEON-100
OriginBeijing, China
ManufacturerZOLIX (OEM/ODM Capable)
CategorySpectroradiometric LED Characterization System
Spectral Range380–780 nm
Spectral Resolution2.5 nm
Measurement Speed≤30 ms per spectrum
Photometric AccuracyLuminous Intensity ±7%, Dominant Wavelength ±1 nm, Chromaticity Coordinates (x,y) ±0.005 (vs. stable reference lamp)
Photometric RepeatabilityLuminous Intensity ±2%, Dominant Wavelength ±0.3 nm, (x,y) ±0.002
Luminous Intensity Range5 mcd – 30,000 mcd
Luminous Flux Range20 mlm – 200 lm
InterfaceUSB 2.0
PowerUSB bus-powered (5 V DC)
Dimensions (Spectrometer Only)140 × 80 × 180 mm
Calibration TraceabilityNIST-traceable
compliant with CIE S 025/E2015 and CIE 127:2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelLBIC
Price RangeUSD 14,000 – 28,000
Excitation SourceMultiple stabilized continuous-wave lasers (e.g., 405 nm, 532 nm, 635 nm, 785 nm)
Laser Power Range0–30 mW, continuously adjustable
Focused Spot Size< 50 µm
Power Stability< 1% RMS over 8 hours
Measurement Repeatability< 2% (RSD)
MicroscopyInterchangeable 10× and 20× objective lenses
Monitoring Camera1.3 MP industrial CMOS camera
Maximum Sample Area100 mm × 100 mm
XY Stage Resolution0.625 µm (closed-loop stepper motor)
Operating Temperature10–35 °C
Calibration StandardNIM-traceable Si or InGaAs photodetectors
ComplianceISO/IEC 17025-aligned calibration procedures, compatible with GLP documentation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelZLX-ES Series
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product TypeDomestic Metrological Standard System
ModelUV-Vis Spectrophotometer Calibration Standard System
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS/Stanford Research Systems
ModelSR540
Frequency Range4 Hz to 3.7 kHz (inner slot: 4–400 Hz
outer slot400–3700 Hz)
Phase Stability0.2°–0.5°
Frequency Accuracy<2%
Output Signal5 V TTL (HCT-compatible), BNC
Control InterfaceFront-panel thumbwheel + external 0–10 V analog input
Reference OutputSync TTL pulse with adjustable phase offset
Blade MaterialChemically blackened, demagnetized brass
Blade Thickness0.5 mm
Diameter102 mm
Slot ConfigurationsDual concentric slots (inner + outer)
Dimensions (Controller)216 × 89 × 343 mm
Weight (Controller)3.2 kg
Motor Life>6000 hours
ComplianceCE, RoHS, FCC Class A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSigma
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSGRM-200
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginFrance
TypePyroelectric Energy Sensor
Max. Repetition Rate25 kHz
Pulse Width Range10 ns – 20 ms
Energy Range10 µJ – 50 J
Spectral Range0.19–20 µm (with appropriate absorber)
Calibration Uncertainty±3% (k=2)
Rise Time~1.5 ms (BF-type)
Damage Threshold1 J/cm² (1064 nm, 10 ns)
InterfaceUSB or RS-232 (via StarLab or Nova II meter)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelMAMOS Series
OriginBeijing, China
ManufacturerZOLIX Optics Co., Ltd.
TypeModular Magneto-Optical Kerr & Reflective Magnetic Circular Dichroism (RMCD) Measurement System
Core CapabilitiesMicro-area MOKE imaging, RMCD spectroscopy, polarization-resolved mapping, time-resolved magnetization dynamics
Laser Source532 nm narrow-linewidth laser (Δλ < 0.00001 nm, M² < 1.2, power stability ±2% RMS over 4 h)
Spatial Resolution≤300 nm (at 532 nm)
Kerr Angle Resolution~0.5 mdeg (~8.7 µrad)
Polarization ControlMotorized polarizer/analyzer with 0.0144° angular resolution
Imaging SensorSony 1-inch CMOS, 20 MP, 15 fps @ 5K, 50 fps @ 1.8K
Precision StageXYZ motorized stage (120 × 120 × 40 mm travel), XY step resolution 40 nm, Z step resolution 10 nm, load capacity >10 kg
Optical ArchitectureAll-reflective, non-magnetic objective or aspheric lens design
SoftwareModular GUI supporting automated MOKE/RMCD/Raman/PL/SHG scanning, polarization sweeps, script-based sequencing (Python-compatible), GLP-compliant data logging with timestamped metadata and audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Regional CategoryDomestic (China)
ModelTIMART
Price RangeUSD 110,000 – 138,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product LineZLX-AS Series
Optical ConfigurationDual-beam and single-beam configurable
Spectral Range200–2500 nm (model-dependent)
Stray Light<5×10⁻⁹ (UV-Vis high-accuracy configuration)
Wavelength Accuracy±0.05 nm (UV-Vis), ±1 nm (NIR)
Photometric Accuracy±0.05%T (UV-Vis standard mode), ±2% (NIR & field-deployable configurations)
Spectral Resolution≤5 nm (adjustable scan step: 0.1–10 nm)
Beam Parallelism≤±5°
Sample PositioningMotorized XYZ + θy/θz angular adjustment (±45°/±90°)
ComplianceASTM E903, ISO 9050, GB/T 2680, EN 410, ANSI Z87.1, USP <857>, FDA 21 CFR Part 11 (software audit trail enabled)