Biological Safety Cabinets
Filter
Showing 31–60 of 80 results
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LA2-4A1 |
| Certification Standards | NSF/ANSI 49, YY0569, EN 12469, JIS K 3800, SANS 12469 |
| ULPA Filtration Efficiency | ≥99.999% for particles >0.12 µm |
| Noise Level | <57.5 dBA (per EN 12469) |
| External Dimensions (L×W×H) | 1420 × 815 × 1540 mm |
| Internal Work Area (L×W×H) | 1260 × 623 × 670 mm |
| Ergonomic Design | 10° inclined sash and work surface |
| Antimicrobial Coating | Isoceide™ on exterior surfaces |
| Control System | Sentinel™ microprocessor-based digital interface |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | LA2-A |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | Model-dependent (e.g., LA2-3A: 1115 × 852 × 1540 mm) |
| Internal Dimensions (L×W×H) | Model-dependent (e.g., LA2-3A: 970 × 623 × 670 mm) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% @ 0.1–0.3 µm |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Control System | Sentinel Gold microprocessor-based digital display with real-time monitoring |
| Optional Features | RS232 data port, night/standby mode, ISOCIDE antimicrobial coating, seamless stainless steel work surface, ergonomic tilt-angle front window (10°), ADA-compliant control panel |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Type | Class II, Type A2 Biosafety Cabinet |
| Model | LA2-G4 |
| Filter Efficiency | ≥99.999% (ULPA) |
| Inflow Velocity | 0.30–0.53 m/s |
| Downflow Velocity | 0.30–0.33 m/s |
| Noise Level | ≤56 dBA |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, AS/NZS 2252.2:2013 |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Category | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| Certification | NSF/ANSI 49, YY0569 |
| Filter Efficiency | ≥99.999% for particles ≥0.1 µm (ULPA) |
| Airflow Velocity (Inflow) | 0.53 m/s (105 fpm) |
| Airflow Velocity (Downflow) | 0.31 m/s (60 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Construction | Seamless One-Piece Stainless Steel Work Chamber |
| Control System | Esco Sentinel Gold Microprocessor-Based Digital Display |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5), IEST-RP-CC001.3, ADA Accessibility Guidelines |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Cabinet Type | Class II, Type A2 |
| Filter Efficiency | 99.999% (ULPA, 0.1–0.3 µm) |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Airflow | Inflow 0.53 m/s (105 fpm), Downflow 0.35 m/s (70 fpm) |
| Construction | Seamless stainless steel work area, ISOCIDE® antimicrobial powder coating |
| Control System | Sentinel Gold™ microprocessor-based digital display with RS232 port |
| Ergonomics | 10° front tilt, ADA-compliant angled control panel and display |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Cabinet Type | Class II, Type B2 (Total Exhaust) |
| Certification | NSF/ANSI 49, YY0569 |
| Filter Efficiency | ≥99.999% for particles ≥0.1 µm (ULPA) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.31 m/s (60 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Construction | Seamless stainless steel work chamber |
| Motor | Brushless DC motor |
| Control System | Esco Sentinel Gold microprocessor-based interface |
| Compliance | Meets IEST-RP-CC001.3 for ULPA filter performance |
| Airflow Configuration | Unidirectional downflow + total external exhaust |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LB2-4B1 |
| Certification | NSF/ANSI 49 & YY0569 |
| ULPA Downflow Filter Efficiency | >99.999% for particles ≥0.12 µm |
| HEPA Exhaust Filter Efficiency | >99.99% for particles ≥0.3 µm |
| Noise Level (per EN 12469) | <58 dBA |
| External Dimensions (L×W×H) | 1420 × 815 × 1568 mm |
| Internal Work Area (L×W×H) | 1260 × 623 × 715 mm |
| Construction | 304 Stainless Steel Work Surface, Isocide™ Antimicrobial Coating, Seamless Front Intake & Sloped Ergonomic Design |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | VBD-4A1 |
| Safety Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1247 × 760 × 1966 mm (adjustable height up to 2271 mm) |
| Internal Dimensions (L×W×H) | 1040 × 680 × 594 mm |
| Inflow Air Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% at 0.12 µm |
| Power Supply | 220–240 VAC, 50 Hz |
| NSF-Certified Waste Container Capacity | 40 US gallons (151 L) |
| Pre-filter | Polyester media, cardboard frame, 870 × 500 mm, 6 units per box |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | VBD-4A1 |
| Cabinet Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1247 × 760 × 1966 mm (adjustable up to 2271 mm height) |
| Internal Dimensions (L×W×H) | 1040 × 680 × 594 mm |
| Inflow Air Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% @ 0.12 µm |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | VDA-A |
| Instrument Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1340 × 762 × 1961 mm / 1645 × 762 × 1961 mm |
| Internal Work Area Dimensions (L×W×H) | 1100 × 465 × 564 mm / 1405 × 465 × 564 mm |
| ULPA Filter Efficiency | ≥99.999% at MPPS (0.12 µm) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | VIVA |
| Cabinet Class | Type II A2-equivalent |
| External Dimensions (L×W×H) | 1423 × 815 × 1510 mm (VA2-4A1-E) / 2030 × 815 × 1510 mm (VA2-6A1-E) |
| Work Area Dimensions (L×W×H) | 1270 × 623 × 680 mm (VA2-4A1-E) / 1870 × 620 × 680 mm (VA2-6A1-E) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Pre-filter | Polyester, 85% arrestance |
| Final Filter | Dual ULPA, ≥99% MPPS @ 0.12 µm |
| Airflow Monitoring | Real-time digital sensing with Sentinel microprocessor control |
| Compliance | ISO 14644-1 Class 3 (equivalent to Fed Std 209E Class 1), NSF/ANSI 49 compliant design principles |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Type | Class II Type A1 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1423 × 815 × 1510 mm (VA2-4A1-E) / 2030 × 815 × 1510 mm (VA2-6A1-E) |
| Internal Work Area Dimensions (L×W×H) | 1270 × 623 × 680 mm (VA2-4A1-E) / 1870 × 620 × 680 mm (VA2-6A1-E) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% at MPPS (0.12 µm) |
| Pre-filter | Polyester, 85% arrestance |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 3 (ISO 3), USP <797>, GLP/GMP-ready |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UVT-S-AR |
| Instrument Type | Class I Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1245 × 585 × 585 mm |
| Internal Dimensions (L×W×H) | 1200 × 520 × 520 mm |
| Filter Efficiency | ≥99% |
| UV Wavelength | 254 nm |
| UV Lamp Power | 30 W (ozone-free) |
| Air Recirculation Rate | 25 m³/h |
| Timer Range | 0–24 h (digital) |
| Illumination | 15 W white LED work surface lighting |
| UV Protective View Window | UV-absorbing coated glass |
| Front Sash | 3-position height adjustment |
| Electrical Supply | 230 V |
| Brand | HD-Lab (HDL) |
|---|---|
| Origin | Beijing, China |
| Model | BSC-1100 II A2 |
| Cabinet Class | NSF/ANSI 49–2022 & EN 12469:2000 Compliant Class II Type A2 |
| External Dimensions (L×W×H) | 1080 × 790 × 2150 mm |
| Internal Work Area (L×W×H) | 915 × 600 × 680 mm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.1–0.2 µm |
| Filter Penetration Rate | ≤0.005% |
| Inflow Velocity | ≥0.5 m/s |
| Downflow Velocity | 0.25–0.5 m/s |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥700 lux |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power Consumption | 1.85 kW |
| Net Weight | 290 kg |
| Compliance | YY 0569–2005, NSF/ANSI 49–2022, EN 12469:2000, ISO 14644–1 Class 5 (ISO Class 5 Equivalent) |
| Brand | HDL (Harbin Donglian) |
|---|---|
| Origin | Beijing, China |
| Model | BSC-1100-L II B2 |
| Cabinet Type | Class II, Type B2 (100% Exhaust, Zero Recirculation) |
| External Dimensions (L×W×H) | 1382 × 790 × 2210 mm |
| Internal Work Area Dimensions (L×W×H) | 1220 × 600 × 680 mm |
| ULPA Filter Efficiency | ≥99.9995% for particles ≥0.1–0.2 µm |
| Filter Penetration Rate | ≤0.005% |
| Noise Level | ≤62 dB(A) |
| Inflow Velocity | >0.5 m/s |
| Downflow Velocity | 0.25–0.5 m/s |
| Vibration (RMS) | ≤3 µm |
| Illuminance | ≥700 lx |
| Power Supply | 220 V AC / 50 Hz |
| Rated Power Consumption | 1.95 kW |
| Max Power Consumption | 2.95 kW |
| Weight | 310 kg |
| Compliance | YY 0569-2005, NSF/ANSI 49-2002, EN 12469:2000 |
| Brand | Nuaire |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | NU-543-300S / 400S / 500S / 600S |
| Instrument Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1057 / 1362 / 1669 / 1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873 / 1178 / 1483 / 1788 × 654 × 724 |
| Filter Efficiency | ≥99.995% at 0.3 µm |
| Brand | NuAire |
|---|---|
| Origin | USA |
| Model | NU-543 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H, mm) | 1057/1362/1669/1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873/1178/1483/1788 × 654 × 724 |
| HEPA Filter Efficiency | ≥99.995% at 0.3 µm |
| Airflow Configuration | 70% recirculated (re-circulated after dual-stage HEPA filtration), 30% exhausted (ducted or via thimble connection) |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 5 (ISO Class 5 equivalent for work area) |
| Brand | Plas-Labs |
|---|---|
| Origin | USA |
| Model | 825-PCR HEPA |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (W×D×H) | 610 mm × 457 mm × 711 mm |
| Internal Dimensions (W×D×H) | 597 mm × 432 mm × 530 mm |
| HEPA Filter Efficiency | ≥99.9997% @ 0.3 µm |
| Operating Noise Level | <40 dB(A) |
| UV Lamp | 254 nm, full-cavity irradiation with 0–30 min timer |
| Viewing Window | 9.5 mm acrylic, beta-radiation shielding |
| Illumination | "Bright Light" LED system, shadow-free, 40,000 h rated life |
| Safety Features | proximity sensors on access doors, positive-pressure internal environment, removable top and outer panels, spill-containment base tray |
| Shelf Configuration | two adjustable white polymer shelves |
| Weight (Shipping) | 51 kg |
| Brand | SuJie |
|---|---|
| Origin | Jiangsu, China |
| Cabinet Type | Class II, Type A2 (NSF/EN 12469 compliant) |
| Cleanliness Class | ISO Class 5 (Federal Standard 209E Class 100) |
| Downflow Velocity | ≥0.35 m/s |
| Inflow Velocity | ≥0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Vibration Peak-to-Peak | ≤6 µm |
| Power Supply | AC 220 V, 50 Hz, Max. 1 kW |
| Lighting Intensity | ≥650 lx |
| UV Lamp | 20 W ×1 or 30 W ×1 |
| Fluorescent Lamp | 20 W ×2 or 30 W ×2 |
| Work Area Dimensions (W×D×H) | 1100×600×640 mm / 1300×600×640 mm |
| External Dimensions (W×D×H) | 1300×815×2210 mm / 1500×820×2210 mm |
| Weight | 300 kg / 340 kg |
| Personnel Protection | ≤10 CFU (impact sampling), ≤5 CFU (slit sampling) |
| Product Protection | ≤5 CFU per agar plate |
| Cross-Contamination Protection | ≤2 CFU per agar plate |
| Supply Filter Size | 1015×460×70 mm (BHC-1100) / 1315×460×70 mm (BHC-1300) |
| Exhaust Filter Size | 490×400×70 mm (BHC-1100) / 890×460×70 mm (BHC-1300) |
| Brand | Suzhou Antai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BSC-1000IIA2 |
| Instrument Type | Class II Type A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1200 × 790 × 2050 mm |
| Internal Dimensions (L×W×H) | 1000 × 600 × 620 mm |
| Filter Efficiency | ULPA ≥99.999% @ 0.12 µm |
| Brand | Suzhou Antai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BSC-1300IIA2 |
| Instrument Type | Class II Type A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1500 × 790 × 2050 mm |
| Internal Dimensions (L×W×H) | 1270 × 600 × 620 mm |
| Filter Efficiency | ULPA ≥99.999% @ 0.12 μm |
| Brand | Suzhou Antai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BSC-1300IIB2 |
| Instrument Type | Class II, Type B2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1500 × 790 × 2330 mm |
| Internal Work Area Dimensions (L×W×H) | 1270 × 600 × 620 mm |
| Filter Efficiency | HEPA ≥ 99.995% @ 0.3 µm |
| Brand | Telstar |
|---|---|
| Origin | Spain |
| Cabinet Type | Class II, Type A2 |
| Certification | EN 12469, TÜV-GS |
| External Dimensions (W×D×H) | 1354 × 759 × 1260 mm |
| Internal Work Area (W×D×H) | 1259 × 605 × 587 mm |
| Sash Opening Height | 200 mm |
| Downflow Velocity | 0.35 m/s |
| Downflow Volume | 882 m³/h |
| Noise Level | 58 dB(A) |
| Illumination | >1000 lux |
| Vibration | <0.005 mm RMS |
| Power Consumption | 1.6 kW |
| UV Lamp | Integrated, Timer-Programmable |
| Fluorescent Lighting | Integrated |
| HEPA Filtration Efficiency | ≥99.999% @ 0.12 µm and 0.3 µm (Supply & Exhaust) |
| Air Recirculation | 70% |
| Exhaust Ratio | 30% |
| Work Surface | Removable stainless steel tray |
| Cabinet Weight | 200 kg |
| Stand Height | 780 mm |
| Exhaust Port Diameter | 160 mm |
| ECO Mode | Yes (reduces downflow to 50%) |
| User Access Control | Dual-level password protection |
| Viewing Window | 10° inclined, anti-reflection, UV-protected tempered glass with bottom-edge unobstructed vision |
| Inlet Design | V-shaped front airfoil |
| Filter Accessibility | Front-accessible for rapid replacement |
| Brand | Telstar |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Custom-Built |
| Instrument Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H) | Customizable |
| Internal Dimensions (L×W×H) | Customizable |
| Filter Efficiency (HEPA/ULPA) | ≥99.999% at 0.12 µm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model Numbers | 51022481, 51022482, 51022483, 51022484 |
| External Dimensions (L×W×H) | 1100–2000 mm |
| Internal Dimensions (L×W×H) | 900–1800 mm |
| HEPA Filter Efficiency at MPPS | ≥99.995% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MSC-Advantage |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1300 × 1580 × 870 mm |
| Internal Dimensions (L×W×H) | 1200 × 780 × 630 mm |
| Filter Efficiency | >99.999% for 0.3 µm particles |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 1300 A2 |
| Instrument Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1300 × 1580 × 870 mm |
| Internal Dimensions (L×W×H) | 1200 × 780 × 630 mm |
| Filter Efficiency | >99.999% for 0.3 µm particles |
| Airflow Pattern | 30% exhaust / 70% recirculation |
| Work Area Dimensions (W×D×H) | 1200 × 495 × 780 mm or 1800 × 495 × 780 mm |
| Exhaust Flow Rate | 330 or 490 CFM |
| Work Surface Area | 0.56 or 0.84 m² |
| Sash Opening Height | 250 mm |
| Fluorescent Illumination | >65 foot-candles (fc) |
| Sound Pressure Level | 63 or 65 dB(A) |
| Heat Output at 25°C | 150 or 260 W |
| Voltage Range | 90–250 V AC |
| Power Consumption | 200 or 400 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | 1300 B2 |
| Instrument Type | Class II, Type B2 Biosafety Cabinet |
| External Dimensions (L×W×H) | 1379 × 1844 × 803 mm |
| Internal Dimensions (L×W×H) | 1232 × (653–742) × 648 mm |
| Filter Efficiency | >99.99% for 0.3 µm particles |
| Airflow Mode | Total Exhaust (No Recirculation) |
| Inflow Velocity | 0.5 m/s (typical, per NSF/ANSI 49) |
| Downflow Velocity | 0.3 m/s (typical) |
| Exhaust Flow Rate | 665–998 CFM |
| Work Surface Area | 0.55–0.82 m² |
| Sash Opening Height | 203 mm |
| Illumination | 91 foot-candles |
| Sound Pressure Level | 65–66 dB(A) |
| Heat Dissipation at 25°C | 22–24 W |
| Voltage | 230 V AC |
| Power Consumption | 280–370 W |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Certification | NSF/ANSI 49, UL Listed, EN 1822 H14 HEPA |
| Model | MSC-1356 / MSC-1358 |
| Airflow | 530 m³/h (330 CFM) / 840 m³/h (490 CFM) |
| Work Area Surface | 0.56 m² / 0.84 m² |
| Front Window Opening | 250 mm (max 535 mm) |
| Internal Dimensions (W×H×D) | 780×1200×495 mm / 780×1800×495 mm |
| External Dimensions (W×H×D) | 1520×1300×795 mm / 1520×1900×795 mm |
| Weight (net) | ~530 kg / ~750 kg |
| Filtration Efficiency | ≥99.999% at 0.3 µm |
| Noise Level | 63 dB(A) / 65 dB(A) |
| Illumination | >65 fc |
| Power Input | 230 V, 50/60 Hz |
| Protection Class | IP20 |
| Electrical Rating | 0.2 kW / 0.4 kW |
| UV Lamp Timer | 1–24 h programmable |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA (assembled in China under strict quality control) |
| Cabinet Class | Class II, Type A2 |
| Compliance | YY 0569-2005 (China NMPA-regulated Class III medical device), NSF/ANSI 49-2022 compliant |
| Airflow System | Dual independent DC motor-driven blowers with SmartFlow™ real-time air velocity balancing |
| Inflow Velocity | ≥0.5 m/s (adjustable and auto-compensated) |
| Downflow Velocity | ≥0.25 m/s (HEPA-filtered) |
| Filtration | Dual HEPA filters (≥99.99% @ 0.3 µm) — supply and exhaust |
| Noise Level | ≤65 dB(A) |
| Power Requirement | 230 V AC, 50/60 Hz |
| Energy Mode | Night-Save mode reduces power consumption by >75% while maintaining ISO Class 5 (Class 100) work area integrity |
| UV Lamp Option | Timer-controlled (30 min – 24 h), germicidal UVC (254 nm) |
| Construction | Monolithic 304 stainless steel interior or modular anti-glare coated interior |
| Sash Opening Options | 3", 4", 5", or 6" vertical sash height |
| Certification | NMPA registered as Class III medical device |