Henven
Filter
Showing 1–30 of 77 results
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 2HJ |
| Reactor Configuration | Dual independent reactors (configurable in series/parallel) |
| Temperature Range | 350–500 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Operating Pressure | 2.5–10 MPa |
| Gas Flow Range | 0–20 L/min |
| Gas Flow Accuracy | ±0.1% FS |
| Liquid Flow Range | 0–20 mL/min |
| Liquid Flow Accuracy | ±0.1 mL/min |
| Level Measurement Accuracy | ±2 mm |
| Catalyst Bed Volume | 0–100 mL (customizable) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BJHJ |
| Price Range | USD 14,000 – 28,000 |
| Raw Material Capacity | 5 m³ |
| Operating Volume | 3 m³ |
| Heating Power | 10 kW |
| Circulation Pump Power | 0–4 kW (adjustable) |
| Circulation Flow Rate | 0–12 m³/h (adjustable) |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 80 °C |
| Continuous Operation Duration | Up to 20 h |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Custom-Engineered |
| Price Range | USD 140,000 – 280,000 |
| High-Temperature Range | 1400 °C |
| Low-Temperature Range | −20 °C |
| Thermal Shock ΔT Range | 1420 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate | 80 °C/min |
| Cooling Rate | 80 °C/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | -150 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Applied Force | 50 N |
| Displacement Range | 2.5 mm |
| Frequency Range | 0.01–100 Hz |
| Heating Rate | 0.1–20 °C/min (dual-loop self-learning PID control) |
| Force Resolution | 0.001 N |
| Displacement Resolution | 0.01 µm |
| Atmosphere Control | Dual-channel mass flow controller (0–200 mL/min), inert/oxidizing/reducing/static/dynamic gas modes |
| Sample Dimensions | Height 0.3–25 mm, Diameter ≤10 mm |
| Operating Modes | Tension, Compression, Bending (3-point & cantilever), Shear, Penetration |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HCR |
| Price Range | USD 10,800–15,000 (FOB Beijing) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Temperature Range | RT to 1150 °C (HCR-1), RT to 1250 °C (HCR-2), RT to 1450 °C (HCR-3), RT to 1550 °C (HCR-4) |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Operating Mode | Fully Automated |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Dynamic heating, isothermal stabilization |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±1 mW to ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| Voltage Input Range | ±10 µV to ±2000 µV (auto-ranging) |
| Vacuum Capability (Optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any setpoint within operating range |
| Calibration Standards Supported | Indium, tin, lead (for temperature and enthalpy calibration) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCR-1 |
| Sample Capacity | Single-sample |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Temperature Range | Ambient to 1150 °C |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| Scan Modes | Dynamic heating, isothermal hold |
| DSC Measurement Range | ±1–±500 mW |
| DSC Sensitivity | ±0.1 μW |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| Signal Range | ±10–±2000 μV (auto-ranging) |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | Indium, tin, lead |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-2 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Sensitivity | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| DSC Measurement Range | ±1–±500 mW |
| DSC Precision | ±0.1 μW |
| Sample Capacity | Single-sample configuration |
| Control Mode | Manual sample loading |
| Thermal Program Modes | Ramp heating, isothermal hold (up to 72 h at any temperature within range) |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Signal Output Range | ±10–±2000 μV (auto-ranging) |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Interface | Integrated LCD display showing furnace temperature, sample temperature, gas status, and real-time signal |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy estimation (multiple algorithms), Tg determination, specific heat comparison method, calibration support (In, Sn, Pb), screenshot capture at arbitrary timestamps, user-defined formula implementation |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-3 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel MFC-controlled gas system (N₂, Ar, O₂, air |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy determination (multiple model algorithms), Tg identification, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition, calibration support (In, Sn, Pb standards) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-4 |
| Sample Capacity | Single-sample configuration |
| Temperature Range | Ambient to 1550 °C |
| Programmable Temperature Control | Heating and Isothermal hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| Heating/Cooling Rate | 0.1–100 °C/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV (RMS) |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | In, Sn, Pb, and user-defined reference materials |
| Optional Accessories | GC/MS transfer line (thermostatted to 200 °C), ceramic/alumina/graphite/quartz/platinum crucibles (0.06 mL & 0.12 mL standard) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCT-1 |
| Price Range | USD 12,500 – 18,000 (FOB Beijing) |
| Temperature Range | Ambient to 1150 °C |
| Heating Rate | 0.1–100 °C/min (user-definable) |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCT-2 |
| Price Range | USD 14,000 – 20,000 (FOB Beijing) |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min (programmable) |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCT-3 |
| Temperature Range | Ambient to 1450 °C |
| Heating Rate | 0.1–100 °C/min (user-definable) |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| DSC Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 μW |
| TG Measurement Range | 1–200 mg |
| TG Resolution | 0.1 μg |
| TG Noise | <0.1 μg |
| Vacuum Capability | 2.5×10⁻² Pa (with optional vacuum pump) |
| DTA Range | ±10 μV to ±2000 μV |
| DTA Resolution | 0.01 μV |
| Crucible Options | Al₂O₃ (0.06 mL / 0.12 mL), Al, graphite, quartz, Pt |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HCT-4 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (customizable for corrosive gases) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Heat Flow Meter Method |
| Sample Capacity | Single Sample per Test |
| Test Environment | Ambient Temperature |
| Thermal Conductivity Range | 0.001–5 W/m·K |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Temperature Control Range | 0–90 °C |
| Sample Dimensions | 300 × 300 × (2–50) mm or 200 × 200 × (2–50) mm |
| Thickness Adjustment | Motorized, Auto-Calibrating |
| Applied Load Range | 0–1500 N |
| Thickness Measurement | High-Precision Displacement Sensor with Zeroing & Calibration Function |
| Compliance Standards | GB/T 10295-2008, ASTM C518, ISO 8301:1991 |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1200 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 °C/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability (Drift) | ±0.1 °C |
| Minimum Heat Flow Resolution | 0.1 µW |
| Power Noise Level | <0.1 µW |
| Crucible Volume | 0.06–0.12 mL |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ-1 |
| Temperature Range | 200 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Isothermal Accuracy | ±0.1 °C |
| Reactor Pressure Range | 0.1–2 MPa |
| Gas Flow Range | 0–200 mL/min |
| Gas Flow Accuracy | ±0.1% FS |
| Liquid Flow Range | 0–10 mL/min |
| Liquid Flow Accuracy | ±0.01 mL/min |
| Catalyst Bed Volume | 0–100 mL (customizable) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HJ-7 |
| Pricing | Available Upon Request |
| Reactor Volume | 100 mL |
| Max Reactor Temperature | 500 °C |
| Tubing Heat Tracing Range | Ambient to 200 °C |
| Gas–Liquid Mixer Outlet Temp | 520 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Operating Pressure | 0.1–20 MPa |
| Gas Flow Rate | 0–40 L/min |
| Light Oil Feed Rate | 0–20 mL/min |
| Heavy Oil Feed Rate | 0–50 mL/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ.10 |
| Reactor Volume | 300 mL |
| Max Operating Temperature | 500 °C (Reactor), 520 °C (Gas-Liquid Mixer Outlet), 200 °C (Line Tracing) |
| Temperature Control Accuracy | ±0.1 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Max Operating Pressure | 20 MPa |
| Gas Flow Range | 0–40 L/min |
| Light Oil Feed Rate | 0–20 mL/min |
| Heavy Oil Feed Rate | 0–50 mL/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ.4 |
| Temperature Range | Up to 500 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Operating Pressure | 3–10 MPa |
| Gas Flow Rate | 0–20 L/min |
| Liquid Feed Rate | 0–10 mL/min |
| Catalyst Bed Volume | 0–100 mL (customizable) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ.6 |
| Reactor Configuration | Dual Parallel Fixed-Bed Reactors (One Medium-Pressure, One Low-Pressure) |
| Max Operating Temperature | 600 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Gas Flow Range | 0–1000 mL/min |
| Liquid Flow Range | 0–5 mL/min |
| Catalyst Bed Volume | 30 mL |
| Control Interface | Integrated Industrial Touchscreen HMI |
| Automation Level | Fully Automated with Embedded Fault Detection & Safety Interlocks |
| Structural Frame | Reinforced 316L Stainless Steel |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ0 |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Pressure | 0.1–0.4 MPa |
| Butadiene Feed Rate | 0–100 mL/min |
| Cyclohexane Feed Rate | 500 mL/min |
| Catalyst Feed Rate | 0–50 mL/min |
| Termination Agent Feed Rate | 0–50 mL/min |
| Total Residence Time (3 Reactors in Series) | 1.5–4 hr |
| Coagulation Vessel Volume | 200 L |
| Reactor Effective Volume (per unit) | 15 L |
| Configuration | 3 Polymerization Reactors + 1 Termination Reactor + 2 Latex Storage Vessels + 1 Particle Formation Vessel |
| Real-Time Monitoring | Temperature, Pressure, Flow (Multi-Point) |
| Structural Frame | High-Strength Integrated Stainless Steel |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJ1 |
| Temperature Range | Up to 800 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Pressure Range | 0.1–10 MPa |
| Gas Flow Range | 0–20 L/min |
| Gas Flow Accuracy | ±0.1% FS |
| Liquid Flow Range | 0–10 mL/min |
| Liquid Flow Accuracy | ±0.01 mL/min |
| Catalyst Bed Volume | 0–10 mL (customizable) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJC |
| Price Range | USD 28,000 – 70,000 |
| Flow Rate | up to 10 L/h |
| Operating Pressure | 1–6.0 MPa |
| Maximum Design Temperature | 600 °C |
| Catalyst Loading Volume | 2 mL |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJCY |
| Temperature Control | 6 independent linear ramp/hold segments up to 550 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Rating | 10 MPa |
| Gas Flow Range | 0–20 L/min, Accuracy: ±0.1% FS |
| Liquid Flow Range | 0–20 mL/min, Accuracy: ±0.1 mL/min |
| Catalyst Loading Capacity | Up to 100 mL (customizable) |
| Control Interface | Integrated industrial-grade LCD touchscreen with仁迈 (Renmai) fluidized-bed control firmware |
| Structural Frame | Heavy-duty 316 stainless steel modular frame |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | HJD-12 |
| Price Range | USD 14,000 – 70,000 |
| Reactor Temperature Range | 500–1000 °C |
| Linear Ramp Rate | 0.1–40 °C/min |
| Isothermal Stability | ±0.1 °C |
| Reactor Pressure Range | 0.1–3 MPa |
| Gas Flow Range | 0–300 mL/min |
| Gas Flow Accuracy | ±0.1% FS |
| Liquid Flow Range | 0–25 mL/min |
| Liquid Flow Precision | ±0.01 mL/min |
| Catalyst Loading Capacity | 0–15 mL (customizable) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | HJDS |
| Price Range | USD 28,000 – 42,500 (FOB Beijing) |
| Maximum Reaction Pressure | 10 MPa |
| Maximum Reaction Temperature | 500 °C |
| Catalyst Bed Volume | 5 mL |
| Reactor Dimensions | 20 mm × 4 mm × 600 mm (ID × Wall Thickness × Length) |
| Liquid Flow Rate Capacity | 150 mL/min |
| Maximum Allowable Pressure Drop Across Catalyst Bed | ≤ 0.3 MPa |
| Temperature & Pressure Control Accuracy | ±1% of setpoint |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | HJQ |
| Flow Rate | 0–10 L/h |
| Operating Pressure | 16.0 MPa |
| Pressure Drop | ≤0.3 MPa |
| Signal Output | 0–5 V |
| Catalyst Loading Volume | 100 mL |
| Maximum Design Temperature | 400 °C |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Henven (Producer) |
| Model | HJQL |
| Flow Rate | ~400 L/h |
| Operating Pressure | 5.0 MPa |
| Pressure Drop | ≤0.3 MPa |
| Signal Input/Output | 0–5 V |
| Catalyst Loading Volume | 100 mL |
| Maximum Design Temperature | 500 °C |
| Dimensions | 420 × 800 × 1800 mm (W × D × H) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HJW |
| Temperature Range | Up to 550 °C |
| Maximum Pressure | 6 MPa |
| Catalyst Bed Volume | 5 mL |
| Construction Material | ASTM A240 S31603 (316 stainless steel) |
| Process Fluid Compatibility | H₂, N₂, H₂O, HF (anhydrous and aqueous) |
| Electrical Interface | 1/4″ FNPT |
| Control System | Integrated touchscreen HMI with Renmai fluidized-bed logic engine |
| Thermal Control | Zoned linear ramping & long-term isothermal stability |
| Safety Architecture | Independent dual-channel temperature/pressure monitoring with auto-shutdown and audible/visual alarm |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | HKG |
| Price Range | USD 14,000–28,000 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 950 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 10 K/min (standard), configurable up to 300 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤0.01% of full scale |