Ningbo Scientz
Filter
Showing 61–90 of 113 results
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Shelf-Type (Non-Contact Heating) |
| Application Scope | Pilot-Scale Processing |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Shelf-Type (In-Situ) Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (Empty Chamber) | ≤5 Pa |
| Condensate Capacity | 4 kg/24 h |
| Cold Trap Temperature (Empty) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SCIENTZ-10LS |
| Instrument Type | Standard Shelf-type Freeze Dryer |
| Scale | Pilot-scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No-load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No-load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manifold Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condenser Capacity (24 h) | 3 kg/batch |
| Condenser Temperature | ≤−56 °C (optional −80 °C configuration available) |
| Dimensions (L×W×H) | 590 × 460 × 450 mm (main unit) + 440 mm (bell jar height) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ-10T |
| Ultrasonic Power Range | 20–1200 W |
| Ultrasonic Frequency Range | 20–25 kHz |
| Maximum Heating Power | 800 W |
| Temperature Control Range | –5 °C to Ambient |
| Reactor Volume | 10 L |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 50–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Multi-sample Processing Capability | Yes |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | SCIENTZ-12N/A |
| Instrument Type | Standard Shelf-Type (Bell-Jar Configuration) |
| Scale | Pilot-Scale |
| Lyophilization Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (W×D×H) | 600 mm × 450 mm × 720 mm + 440 mm (cold trap height) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SCIENTZ-12N/C |
| Instrument Type | Manifold (Stopcock) Configuration |
| Application Scope | Laboratory-Scale Lyophilization |
| Lyophilization Area | 0.12 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm (main unit) + 440 mm (manifold height) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Manifold-Style Freeze Dryer with Heated Shelf |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum (Empty Chamber) | ≤5 Pa |
| Condensate Capacity | 3 kg/24 h |
| Cold Trap Temperature (Empty) | ≤−56 °C |
| Dimensions (L×W×H) | 590 × 460 × 400 mm + 440 mm (Chamber Height) |
| Compressor | Imported High-Efficiency Single-Stage or Optional Dual-Stage Cascade (−80 °C Capable) |
| Control System | 7-inch True-Color Touchscreen with Embedded Industrial OS |
| Heating System | 36 V Silicone Rubber Heated Shelf with PID Temperature Control |
| Chamber Material | One-Piece Molded Polycarbonate (Optically Transparent, Corrosion-Resistant, Leak-Tight) |
| Vacuum Interface | Standard KF-25 Flange |
| Data Management | Onboard Curve Storage, USB Export, PC-Compatible Software with Audit Trail Support |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SCIENTZ-150 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 800 × 460 × 450 mm |
| Minimum Processing Volume | >30 mL |
| Operating Pressure Range | 0–150 bar |
| Temperature Control | Integrated + External Cooling Interface |
| Flow Rate | Variable via Frequency-Controlled Pump |
| Valve Options | Impact Valve (R), Spherical Valve (PS), Diamond Valve, Stellite Valve |
| Construction Material | ASTM A240 Grade 316L Stainless Steel |
| Particle Size Reduction | Down to <100 nm (typical under optimized conditions) |
| Cell Disruption Efficiency | >95% (validated for E. coli, S. cerevisiae, and Chlorella vulgaris) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SCIENTZ-15T |
| Ultrasonic Power Range | 200–1500 W |
| Ultrasonic Frequency Range | 20–25 kHz |
| Maximum Heating Power | 1200 W |
| Temperature Control Range | −5 °C to ambient |
| Tank Capacity | 15 L |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-16TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Processing Capacity | 16 samples |
| Cooling Mode | Integrated temperature-controlled rack (ambient to ~15 °C recommended) |
| Pulse Mode | Adjustable on/off duty cycle |
| Protection Features | Overtemperature, overload, and system self-diagnosis |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Standard Manifold Freeze Dryer |
| Application Scope | Pilot-Scale |
| Lyophilization Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm + 440 mm (condenser height) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | SCIENTZ-18N/E |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm + 440 mm (cold trap height) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SCIENTZ-207B |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 1070 × 340 × 460 mm |
| Processing Volume Range | 15–250 mL |
| Maximum Operating Pressure | 0–180 MPa |
| Material Contact Surface | ASTM F899 Grade 316L Stainless Steel |
| Temperature Control | External Chilled Circulation Interface (Compatible with Standard Laboratory Chillers) |
| Sample Throughput | Continuous Flow, Auto-Feeding |
| Valve Core Material | Synthetic Diamond |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | SCIENTZ-20F/A |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Ice Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Probe Homogenizer |
| Dimensions (W×D×H) | 416 × 244 × 300 mm |
| Sample Volume Range | 10–40,000 mL |
| Operating Frequency | 20–25 kHz |
| Power Output | Adjustable, Continuous & Pulsed Mode |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature Protection, Overload Detection, Timed Shutdown |
| Control Interface | Digital Panel with Real-Time Display |
| Cooling Method | Air-Cooled Generator |
| Compliance | CE-marked, ISO 9001 Certified Manufacturing Facility |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-24TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 100 µL – 5 mL |
| Parallel Processing Capacity | 24 samples |
| Cooling Method | Integrated Temperature-Controlled Rack (External Chiller Interface Supported) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Programmable Protocols | Up to 20 user-defined methods |
| Safety Features | Overtemperature & Overload Protection, Real-time System Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Probe Homogenizer |
| Dimensions (W×D×H) | 416 × 244 × 300 mm |
| Sample Volume Range | 10–40,000 mL |
| Operating Frequency | 20–25 kHz |
| Probe Material | Titanium Alloy (Grade 5) |
| Power Output | Adjustable, Continuous & Pulse Modes |
| Safety Features | Overtemperature, Overload, and Timer Alarm |
| Dispersion Mechanism | Acoustic Cavitation in Liquid Media |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCIENTZ-30T |
| Ultrasonic Power Range | 200–1800 W |
| Ultrasonic Frequency Range | 20–25 kHz |
| Maximum Heating Power | 1800 W |
| Temperature Control Range | −5 °C to Ambient |
| Chamber Volume | 30 L |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Development |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (Empty Chamber) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (Empty) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Development & Process Optimization |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scale | Pilot-Scale |
| Lyophilization Area | 0.21 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Dimensions (L×W×H) | 750 × 640 × 1200 mm |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCIENTZ-48L |
| Pricing | Upon Request |
| Brand | Ningbo Scientz |
|---|---|
| Model | SCIENTZ-48LT |
| Throughput | 48 samples per run |
| Drive Mechanism | High-frequency vertical oscillation |
| Temperature Control | Integrated refrigerated compressor (–10 °C to +4 °C operational range) |
| Sample Vessel Type | Sealed 0.2–2.0 mL centrifuge tubes |
| Display | Full-color capacitive touchscreen interface |
| Compliance | Designed for GLP-compliant workflows |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 360 × 420 × 520 mm |
| Net Weight | 42 kg |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-48TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Maximum Ultrasonic Power | 2400 W |
| Sample Volume per Tube | 100 µL – 4 mL |
| Parallel Processing Capacity | 48 Samples |
| Temperature Control | Not Specified (External Cooling Required) |
| Pulse Mode | Adjustable Continuous or Duty-Cycle Mode |
| Programmable Protocols | Up to 20 User-Defined Methods |