PULUODY
Filter
Showing 91–120 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 18854, JJG/T 066 |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent) |
| Channel Count | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Pressure Range | −0.08 to 0.8 MPa |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temp Range | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | ASTM D6786, ISO 11500, GJB 380, DL/T 432, MIL-STD-1246, GJB 420A/B, DL/T 1096 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 8th-Generation Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Sample Volume Accuracy | ±1% |
| Pressure Range | −0.08 to 0.8 MPa |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature | 0–50 °C |
| Power Supply | 220 V, 50 Hz, <80 W |
| Compliance Standards | ISO 11171, ISO 4406, ISO 4402, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, DL/T 432, GJB 420A/B, ASTM D2276, MIL-STD-1246, USP <788>, USP <789> |
| Software Platform | PULL 8.1 Industrial Control & Analysis System (multi-language: English, Chinese, Japanese, Korean, etc.) |
| Data Storage | 3000+ tests on embedded industrial PC |
| Output Interface | RS232, integrated thermal printer, color LCD touchscreen (dual touch/keyboard input), iPad-compatible data acquisition module |
| Calibration Support | ACFTD & MTD traceable calibration |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Model | PLD-0201I |
| Measurement Principle | Light Obscuration (LO) per ISO 11171:1999 / ISO 4406:1999 / NAS1638 / GJB420B |
| Laser Sensor | 7th-Generation Narrow-Beam Laser Detector (PCF-7A) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channels | 8 user-configurable size thresholds |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min via precision piston pump with electromagnetic flow regulation |
| Pressure Range | –0.06 to 0.7 MPa (dual positive/negative pressure pre-treatment system) |
| Viscosity Handling | up to 350 cSt |
| Max Particle Concentration | 10,000 particles/mL (≤5% coincidence error) |
| Test Duration | Adjustable, default 12.5 s |
| Operating Temp | Ambient to 65 °C |
| Ambient Temp | 0–50 °C |
| Power | 220 V AC, 50 Hz, <80 W |
| Calibration Compliance | GB/T 18854–2002, ISO 11171:1999, JJG 066–95 |
| Data Output | Real-time particle count/size distribution, histogram, ISO 4406 & NAS1638 contamination grade assignment, built-in thermal printer |
| Interface | RS232 serial port |
| Software | P6.4 Analysis Suite (integrated LabPC7 platform) |
| Regulatory Support | GLP-compliant audit trail, FDA 21 CFR Part 11-ready configuration (optional), traceable calibration certificate available from National Defense Science & Technology Industry First-Class Particle Metrology Station (No. 116) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Detection Channels | 8 user-configurable channels |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Sample Flow Rate | 5–60 mL/min |
| Sample Volume Accuracy | ±1% |
| Test Duration | Adjustable, default 12.5 s |
| Viscosity Limit | ≤350 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V, 50 Hz, <80 W |
| Calibration Standard | GB/T 18854–2002 (equivalent to ISO 11171:1999) |
| Compliance Standards | ISO 4406:1999, NAS 1638, GJB 380, GJB 420 |
| Data Interface | RS232 |
| Control System | Integrated Industrial PC or External PC |
| Software | P6.4 Particle Analysis Suite (Standalone & PC Edition) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PLD-0201 (Latest) |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171:1999, GB/T 18854–2002, JJG 066–95 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171) |
| Particle Size Range | 1–450 µm |
| Channel Resolution | 1000 adjustable channels (user-selectable 8-channel configuration) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Sample Volume Precision | ±1% |
| Flow Rate | 5–60 mL/min |
| Test Duration | Adjustable down to 12.5 s |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pre-treatment system) |
| Max. Viscosity Handling | ≤350 cSt |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Photometric Blockage |
| Measurement Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Number of Adjustable Channels | 8 |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Pressure Range | −0.6 to +0.7 bar (integrated positive/negative pressure pretreatment system) |
| Viscosity Handling | up to 350 cSt |
| Operating Temperature | ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Calibration Compliance | GB/T 18854–2002 (equivalent to ISO 11171:1999), JJG 066–95 |
| Standards Supported | ISO 4406, NAS 1638, GJB 380, GJB 420, GB/T 14039–2002 |
| Data Output | Real-time particle count per channel, histogram, contamination grade assignment, RS232 interface, built-in thermal printer |
| Software | P6.4 Particle Analysis Suite (embedded & PC versions) |
| Regulatory Traceability | Calibrated and certified by the AVIC Particle Metrology Testing Station (National Defense Science & Technology Industry First-Class Particle Metrology Station No. 116) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PLD-0201 |
| Price | USD 45,800 (FOB Shanghai) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Calibration Standards | ISO 11171:2016, ISO 4402:1991, GB/T 18854–2002, JJG/T 066, NAS 1638, ISO 4406:2021 |
| Measurement Range | 0.01 µm – 1000 µm (configurable sensor modules) |
| Channel Resolution | Up to 1000 user-definable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Max. Viscosity Handling | ≤450 mm²/s |
| Operating Temp. | 20–65 °C (sample), 0–50 °C (ambient) |
| Pressure Range | –0.08 to 0.8 MPa |
| Data Storage | 3000+ tests onboard |
| Output Interface | RS232, touchscreen GUI, integrated thermal printer |
| Software | PULL 8.1 Multi-Language Platform (EN/CN/JP/KO/DE/FR/ES/IT/RU/AR) |
| Compliance Support | ASTM D6786, USP <788>, ISO 21501-4, GLP/GMP audit trail (optional), FDA 21 CFR Part 11 compliant mode (with optional license) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-008 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa |
| Compliance Standards | ISO 4406, NAS 1638, ISO 11171, ISO 4402, GB/T 14039, DL/T 432, GJB 420A/B, ASTM D2276, MIL-STD-1246, USP <788>, and 510+ global particle contamination standards |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-01 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Photometric Blocking |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-treatment system) |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171/GB/T 18854) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (cleaning) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | –0.08 to 0.8 MPa |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-0201-03 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Pressure Range | –0.08 to 0.8 MPa (dual-polarity pre-treatment system) |
| Operating Temperature | Ambient to 65 °C |
| Storage Capacity | 3000 tests onboard (industrial PC) |
| Compliance | ASTM D6786, ISO 4406:2017, NAS 1638, DL/T 1096, GJB 420B, MOOG, ISO 11218 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201-04 |
| Measurement Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406, NAS 1638, ISO 11171, ISO 4402 |
| Sample Flow Control | Dual-precision piston pump + electromagnetic flow regulation |
| Adjustable Sizing Channels | User-definable threshold settings with built-in pulse-height calibration |
| Sample Handling | Integrated pressurized/depressurized sampling chamber with stirring and degassing functions |
| Display & Interface | 7-inch color TFT-LCD touchscreen with dual-input (touch + keypad) |
| Data Output | RS232 serial port, on-device thermal printer, iPad-compatible data acquisition |
| Software Architecture | Decoupled analysis & calibration modules |
| Calibration Support | Traceable to GBW reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-0201-16-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | GB/T 18854–2002 (ISO 11171:1999, JJG 066–95) |
| Reporting Standards | ISO 4406, NAS 1638, GB/T 14039, DL/T 1096, ISO 4402 |
| Measurement Range | 1–450 µm (configurable sub-ranges: 2–100 µm, 1–150 µm, 2–200 µm) |
| Channel Count | 1000 size bins |
| Repeatability | <5% CV (at ≥1000 counts per sample) |
| Sample Flow Rate | 10–60 mL/min (online), 20–150 mL/min (flush) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Fluid Temperature | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Output Interfaces | RS232, 4–20 mA analog, customizable alarm relay |
| Data Storage | 3000 records (100 full test reports) |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Fully compatible with ISO/IEC 17025-aligned calibration workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-3 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) / Photometric Blockage |
| Calibration Standards | ISO 11171, ISO 4406, NAS 1638, GB/T 18854, JJG/T 066 |
| Detection Channels | 1000 adjustable size bins |
| Flow Control | Precision piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Range | 1 mL to unlimited (user-defined) |
| Display | Color LCD touchscreen with dual input (touch + keypad) |
| Data Output | RS232 serial interface, built-in thermal printer, iPad-compatible data acquisition |
| Software | PULL 8.1 multi-language platform (English, Chinese, Japanese, Korean, etc.), GLP-compliant audit trail, 3000-test local storage |
| Compliance | Supports FDA 21 CFR Part 11-ready configuration (via optional software module), ISO/IEC 17025 traceable calibration protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-7 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, DL/T 1096, GJB 380 |
| Measuring Range | 1–1000 µm (sensor-dependent |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Reporting | Particles/mL + ISO 4406/NAS 1638 contamination codes |
| Data Interface | RS232 |
| Control System | Integrated industrial PC with embedded OS |
| Display | Touchscreen LCD with dual input (touch + keypad) |
| Software | P6.4 Analysis Suite (embedded & PC versions) |
| Compliance | GB/T 18854, JJG/T 066, JJG 1061, ISO 11500, DL/T 432 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-8 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Minimum Detectable Size | 0.01 µm (nano-range mode) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, ASTM D6786, DL/T 432, DL/T 1096, GJB 380, GJB 420A/B, MIL-STD-1246, GB/T 14039, GB/T 18854 |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Data Storage | 3,000 tests (embedded industrial PC) |
| Interface | RS232 |
| Output | Particle count per mL, size distribution histogram, contamination grade (ISO/NAS), printable reports |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-8 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (configurable sensor |
| typical operational range | 0.5–600 µm) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Reporting Standards | ISO 4406:1999/2017, NAS 1638, DL/T 1096, MOOG, ISO 11218 |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Sample Handling | Integrated pressure-assisted degassing, magnetic stirring, and high-viscosity compensation |
| Display & Interface | 7-inch TFT-LCD touchscreen with dual input (touch + keypad), embedded OS, thermal printer |
| Data Output | RS232 serial interface, histogram, size distribution curve, particle count per mL, contamination grade |
| Software | P6.4 Analysis Suite (embedded & PC versions) |
| Compliance Support | FDA 21 CFR Part 11 audit trail (via PC software), GLP/GMP traceability mode |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-DL |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (flushing) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa |
| Data Storage | 3000 tests (onboard industrial PC) |
| Interface | RS232 |
| Compliance | ISO 4406, NAS 1638, DL/T 432, DL/T 1096, GJB 420B, ASTM D6786, MIL-STD-1246, MOOG, ISO 11218 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-GT |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-treatment system) |
| Data Storage | 3000 tests onboard |
| Compliance | ASTM D6786, ISO 4406:2017, NAS 1638, DL/T 1096, GJB 420B, MOOG, ISO 11218 |
| Brand | PULUODY |
|---|---|
| Model | PLD-0201L |
| Measurement Principle | Light Obscuration (LO) / Optical Blockage |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump with electromagnetic flow regulation (5–60 mL/min) |
| Pressure Range | −0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment) |
| Viscosity Limit | ≤350 cSt (mm²/s) |
| Operating Temperature | Ambient to 65 °C |
| Environmental Temp. | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Compliance Standards | ISO 4406:1999, NAS 1638, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95, GJB 380, GJB 420 |
| Data Interface | RS232 serial port |
| Built-in Printer | Yes |
| Calibration Traceability | Certified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PLD-0201NEW |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Laser Sensor | 6th-generation narrow-beam laser detector |
| Sensitivity | 1 µm (per ISO 4402) / 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–450 µm |
| Number of Adjustable Channels | 8 |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Sampling Volume | 1 mL to unlimited (user-definable) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment) |
| Max. Fluid Viscosity | ≤350 mm²/s |
| Operating Temperature | Ambient to 65°C |
| Ambient Temperature Range | 0–50°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Compliance Standards | ISO 4406, NAS 1638, GJB 380, GJB 420, GB/T 14039–2002, GB/T 18854–2002 (equivalent to ISO 11171:1999), JJG 066–95 |
| Calibration Traceability | Certified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station) |
| Data Output | Real-time particle count per channel, contamination grade assignment, histogram generation, built-in thermal printer |
| Interface | RS232 serial port for external PC connection and data archiving |
| Software | P6.4 Particle Analysis Suite (integrated embedded OS + optional PC version) |
| Auto-Cleaning Function | Yes |
| Sample Pretreatment | None required |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PLD-0203 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171, ACFTD/ISO 4402 |
| Compliance | ISO 4406:2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Sensor Generations | 7th-generation dual-laser narrow-beam optical sensors |
| Software | P6.4 Integrated Particle Analysis Suite (PC & embedded versions) |
| Control Interface | Industrial-grade touchscreen HMI + optional IPC integration |
| Measurement Range | 0.03 μm to 3000 μm (configurable sensor modules A–N) |
| Channel Count | Up to 1000 user-configurable size channels (any 16 active per test) |
| Sensitivity | 1 μm (per ISO 4402) or 4 μm(c) (per ISO 11171 / GB/T 18854) |
| Accuracy | < ±3% |
| Volume Precision | ±1% |
| Sample Volume | 1–200 mL (programmable) |
| Flow Rate | Sampling 5–60 mL/min |
| Max Online Pressure | 0–0.6 MPa (standard) |
| Viscosity Range | Offline ≤99 mm²/s |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Resolution | ≥90% at 60 mL/min |
| Reporting | Real-time particle count per size bin, distribution histogram, cumulative curve, ISO/NAS/GJB contamination code, pass/fail flagging |
| Data Output | RS232, RS485, USB, analog 4–20 mA / 0–5 V, MODBUS RTU |
| Alarm Logic | Configurable threshold-based超标 alert (hardware + software) |
| Storage Capacity | Up to 6,000 test records (200 × 30-result sets) |
| Auto-Cleaning | Integrated post-test fluidic purge cycle |
| Operating Temp. | Sample 20–65 °C |
| Power | 220 VAC, 50 Hz, <80 W |
| Metrological Accreditation | CALIBRATED BY National Northwest Metrology & Testing Center (civil) / CASC First-Level Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Measurement Principle | Light Blockage (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Particle Size Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Volumetric Accuracy | ±1% |
| Flow Rate (Sampling) | 5–60 mL/min |
| Flow Rate (Cleaning) | 5–150 mL/min |
| Max. Online Pressure | 0–31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Ambient to 65°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203 (8-Channel) |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam sensor |
| Measurement Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliant with | ISO 4406:1987/1999, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Particle Size Range | 0.03 µm to 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-definable size channels (16 active per test) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Volume Accuracy | ±1% |
| Sample Flow Rate | 5–60 mL/min (test), 5–150 mL/min (cleaning) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Operating Pressure (Online) | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure regulator) |
| Sample Volume | 1–200 mL (programmable) |
| Temperature Range | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Auto-Cleaning Function | Yes |
| Software | P6.4 Analysis & Testing Suite (Integrated & PC Edition) |
| Compliance Support | FDA 21 CFR Part 11 audit trail (optional configuration), GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Sample Volume Accuracy | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Operating Pressure | 0–0.6 MPa (standard) |
| Temperature Range | Sample: 20–65°C |
| Ambient | 0–50°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA analog, MODBUS RTU |
| Alarm Output | Configurable particle count or size-based threshold alert |
| Internal Storage | Up to 6000 test records (200 tests × 30 results each) |
| Software | P6.4 Particle Analysis Suite (PC & embedded integrated version) |
| Display | Color LCD touchscreen interface |
| Self-cleaning Function | Integrated post-test rinse cycle |
| Regulatory Traceability | Certified by National Northwest Metrology & Testing Center (civilian) and PLA Commission of Science, Technology and Industry for National Defense — First-Level Particle Metrology Station (military) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-0203 Series |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Laser Sensor | 7th-generation dual-laser narrow-beam detector |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 channels (user-selectable 16 size bins) |
| Sensitivity | 1 µm (ISO 4402) or 4 µm(c) (ISO 11171 / GB/T 18854) |
| Resolution | ≥90% @ 60 mL/min |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Sample Volume Accuracy | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Pressure Rating | 0–0.6 MPa (standard) |
| Standards Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500, GB/T 18854, JJG 1061, MTD/ISO 11171, ACFTD/ISO 4402, ASTM F658-87 (PSL calibration) |
| Software | P6.4 Integrated Analysis & Testing Software (PC & embedded versions) |
| Control Interface | Industrial-grade touchscreen LCD (integrated IPC or external industrial PC) |
| Data Output | Real-time particle count per channel, size distribution histogram, cumulative curve, contamination grade classification (NAS/ISO), built-in thermal printer, RS232/RS485/USB, MODBUS, 4–20 mA & 0–5 V analog outputs |
| Storage Capacity | Up to 6,000 test records (200 tests × 30 results each) |
| Self-Cleaning Function | Yes |
| Operating Temperature | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Calibration Traceability | Certified by National Northwest Metrology & Testing Center (civil) or CASC First-Level Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0203-16 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Software | P6.4 Integrated Analysis & PC Edition |
| Control System | Embedded Industrial PC or External Industrial PC |
| Compliance Standards | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, ISO 11500, DL/T 432, GJB 380 |
| Calibration Standards | JJG 1061, ISO 11171, ISO 4402 (ACFTD), GB/T 18854, ASTM F658-87 (PSL Latex Spheres) |
| Measurement Range | 0.03 µm – 3000 µm (model-dependent configuration) |
| Sensitivity | 1 µm (ISO 4402) or 4 µm(c) (ISO 11171 / GB/T 18854) |
| Channel Count | 1000 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Accuracy | <±3% |
| Sample Volume | 1–200 mL (programmable) |
| Volume Precision | ±1% |
| Online Pressure Range | 0–0.6 MPa (standard) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Temperature Range | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, ±1%, <80 W |
| Data Output | Particle count vs. size distribution, histogram, cumulative curve, contamination grade (NAS/ISO), built-in thermal printer |
| Communication Interfaces | RS232, RS485, USB (U-disk), MODBUS, 4–20 mA analog output, 0–5 V analog output |
| Alarm Function | Configurable threshold-based particle count alarm |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Auto-Cleaning | Yes, post-analysis rinse cycle |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail (software-enabled), GLP/GMP-ready data integrity framework |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0203-16 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor (7th Generation) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance Standards | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-selectable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Accuracy | < ±3% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Sample Volume Precision | ±1% |
| Flow Rate | Sampling 5–60 mL/min |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Pressure | 0–0.6 MPa (standard) |
| Sample Temperature | Ambient to 65 °C |
| Ambient Temperature | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, MODBUS, 4–20 mA / 0–5 V analog |
| Data Storage | Up to 6000 test records (200 tests × 30 results/test) |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail (optional configuration), GLP/GMP-ready reporting structure |
| Cleaning Protocol | Automated post-test rinse cycle |
| Certification | Calibrated per national military standard by CALIBRATION AUTHORITY OF THE COMMISSION OF SCIENCE, TECHNOLOGY AND INDUSTRY FOR NATIONAL DEFENSE (CSTIND) — Grade I Particle Metrology Station (Military Grade), or NORTHWEST NATIONAL METROLOGY & TESTING CENTER (Civil Grade) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Channel Count | 1000 configurable size channels (16 user-selectable bins) |
| Size Range | 0.03 µm – 3000 µm (model-dependent configuration) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Resolution | ≥90% at 60 mL/min |
| Accuracy | < ±3% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Sample Volume | 1–200 mL (programmable) |
| Volume Precision | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Pressure Rating | 0–0.6 MPa (standard) |
| Operating Temp. | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Output | Real-time particle count vs. size histogram, cumulative/differential distribution, contamination grade (NAS/ISO), RS232/RS485/USB, 4–20 mA & 0–5 V analog outputs, MODBUS RTU, built-in thermal printer |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Cloud Integration | PULUODY Oil Monitoring Cloud Platform |
| Self-Cleaning Function | Yes |
| Onboard Storage | Up to 6000 test records (200 assays) |
| Regulatory Support | Audit trail, user access control, electronic signature-ready for GLP/GMP environments per FDA 21 CFR Part 11 guidance |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171, JJG 1061 |
| Compliance Standards | ISO 4406:1987/1999, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm to 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-selectable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Volumetric Accuracy | ±1% |
| Sample Volume | 1–200 mL (programmable) |
| Flow Rate | 5–60 mL/min (test), 5–150 mL/min (cleaning) |
| Max. Online Pressure | 0.6 MPa (standard), 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Sample inlet 20–65°C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Self-cleaning Function | Yes |
| Software | P6.4 Analysis & Testing Software (Integrated & PC Edition) |
| Control Interface | Industrial-grade color touchscreen LCD |
| Regulatory Certification | Calibrated per national military metrology standards (CNSA Defense Science & Technology Commission Level-1 Particle Metrology Station) |