VICI
Filter
Showing all 23 results
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VICI Valco Series Valves |
| Pricing | Available Upon Request |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | VICI Cheminert M |
| Flow Range (M10) | 10 nL – 10 mL |
| Flow Range (M50) | 50 µL – 50 mL |
| Pump Type | Syringe-free, bidirectional, anodized displacement pump |
| Valve Configuration | Multi-position fluid path selection valve |
| Program Storage | Up to 100 user-defined methods |
| Physical Design | Compact benchtop footprint |
| Compliance Context | Designed for GLP-compliant liquid handling in regulated analytical laboratories |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | D-2 |
| Detection Modes | Electron Capture (EC) and Helium Ionization (HI) |
| Ion Source | Pulsed DC helium discharge (non-radioactive) |
| Detection Principle | Electron capture for electronegative compounds |
| Minimum Detectable Concentration | Sub-pg (10⁻¹² g) in EC mode |
| Linear Dynamic Range | >10⁵ (HI mode) |
| Gas Requirements | Ultra-high-purity helium (99.999%+, with integrated purifier) |
| Compatibility | Retrofit-capable for legacy GC systems (e.g., Agilent, Thermo, Shimadzu) |
| Regulatory Compliance | Fully compliant with EPA Method 8021B, ASTM D6667, and USP <621> for residual solvent analysis |
| Brand | VICI |
|---|---|
| Origin | USA |
| Series | Dynacal (Standard, XLT Long-Life, Membrane-Type) & G-Cal |
| Permeation Rate Range | 5–50,000 ng/min (Dynacal) |
| Temperature Sensitivity | Low (G-Cal), Controlled-Environment Optimized (Dynacal) |
| Compliance | Designed for ASTM D6167, ISO 6145-8, USP <1225>, and GLP/GMP traceable calibration workflows |
| Application Scope | Chromatographic calibrations (GC, GC-MS), ambient air monitoring, toxic gas standard generation, EPA Method TO-14/TO-15 support |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | FID Gas Station |
| Hydrogen Flow Rate | 100–1000 mL/min |
| Hydrogen Purity | 99.9996% or 99.99996% |
| Hydrogen Output Pressure | up to 11 barg (160 psig) |
| Zero Air Flow Rate | 1.8–5 L/min |
| Zero Air Hydrocarbon Content | < 0.1 ppm |
| Configuration Options | Horizontal (GC-under bench) or Vertical (space-saving rack-mount) |
| Rack Compatibility | 19-inch standard enclosure (Hydrogen 19” Rack Plus variant) |
| Compliance | Designed for continuous operation in GLP/GMP and ISO/IEC 17025-accredited laboratories |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | GC> Ultra-Zero Air Generator |
| Hydrocarbon (HC) Purity | < 0.1 ppm |
| CO₂ Removal | < 5 ppm |
| CO Removal | < 50 ppm |
| NOₓ & SOₓ Removal | < 0.1 ppm |
| Flow Rate Range | 1–30 L/min |
| Maximum Output Pressure | 6.5 barg (95 psig) |
| Technology | Catalytic Oxidation + Multi-Stage Purification |
| Cabinet Mount Option | 19-inch Rack Compatible |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HP Plus Tower |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 0.5–4 L/min |
| Output Pressure | 5 bar (75 psig) |
| Nitrogen Purity | 99.999% (≤10 ppm O₂, ≤0.1 ppm total hydrocarbons with optional HC module) |
| Dew Point | −50 °C |
| Inlet Air Pressure | 7–10 bar (100–160 psi) |
| Interface | LED display with power switch, system status, and error indicators |
| Connection | Inlet – 1/4" NPT, Outlet – 1/8" NPT |
| Noise Level | Low (external air compressor design) |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | JR-792 |
| Tube Compatibility | 1/16" (1.59 mm) and 1/8" (3.18 mm) OD stainless steel tubing |
| Cutting Mechanism | Adjustable scissor-grip rotary wheel with tungsten carbide cutting wheel |
| Blade Replacement | Tool-free, snap-in JR-793 replacement wheels |
| Finish Quality | Burr-minimized, perpendicular, dimensionally stable cuts |
| Construction | Precision-machined stainless steel body with ergonomic polymer grips |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | Mistral Evolution |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 10–40 NL/min |
| Output Pressure | 8 bar(g) |
| Nitrogen Purity | 98.0–99.5% |
| Dew Point | –50 °C |
| Compliance | Designed for LC/MS OEM integration |
| Form Factor | Benchtop, under-bench installable with casters |
| Control Interface | Integrated LCD display (pressure, flow, temperature, system status) |
| Auto-restart on power recovery | Yes |
| Optional integrated oil-free low-noise air compressor | Available |
| Dual-gas configuration (N₂ + compressed air) | Supported |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 150 |
| Pricing | Available Upon Request |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | Model 230 |
| Temperature Control Range | Up to 100°C |
| Flow Stability | Constant flow through permeation tube chamber |
| Dilution Flow Range | Wide, enabling linear calibration across multiple concentration levels |
| Configuration | Benchtop dynamic gas calibration system with integrated mass flow controllers and temperature-regulated permeation module |
| Compliance Context | Designed for traceable calibration per EPA Method TO-15, ASTM D6196, ISO 16017, and USP <1231> for VOC analyzers |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 235 |
| Price Range | USD $1,500 – $7,500 |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 345 |
| Price Range | USD 1,400 – 7,200 (based on configuration and regional duties) |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 505 |
| Price Range | USD $1,200 – $6,800 |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MTGA6002 Online |
| Pricing | Available Upon Request |
| Detector Compatibility | PDHID, PDPID, PDECD, FID, Micro-TCD, RGD |
| Detection Mode | Pulsed Discharge |
| Minimum Detectable Concentration | 1 ppb (for most analytes) |
| Maximum Detector Configuration | 4 simultaneous detectors |
| Communication Interfaces | 4–20 mA, OPC UA, Profibus DP, Ethernet TCP/IP |
| Automation Level | Fully Automated, Remote Operation Capable |
| Design Architecture | Modular, User-Configurable |
| Application Scope | Trace Impurity Analysis in High-Purity Gases, Electronic Specialty Gases, Food-Grade Gas QC, Remote Toxic Gas Monitoring |
| Hazardous Area Suitability | Compatible with Third-Party ATEX/IECEx-Certified Detectors |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model Compatibility | Agilent 8890 / 7890 / 6890 GC |
| Detection Modes | Pulsed DC Helium Discharge (Electron Capture & Helium Photoionization) |
| Detection Limits | Sub-pg to fg (EC mode) |
| Temperature Stability | ±0.02 °C (TCD variant) |
| Carrier Gas Purification | Valco HP2 (He/Ar/Ne/Kr/Xe), NP2 (N₂), <1 ppm reactive impurities |
| Brand | VICI |
|---|---|
| Model | PS-050025 |
| Volume | 100 µL |
| Needle | RN (Removable Needle), Bevel Tip, 0.029" OD × 0.005" ID × 2" L |
| Maximum Pressure Rating | 250 psi |
| Seal Material | PTFE Plunger Tip & Needle Seal |
| Barrel Material | Glass |
| Valve Type | Integrated Push-Button Actuated On/Off Valve |
| Compliance | Designed for GLP/GMP-compliant chromatographic workflows requiring trace-level sample integrity |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | SWH4, HKS, VSH, FRK1 |
| Unit Price | USD 1.00 |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | VICI TGA |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limit | Sub-ppb (parts-per-quadrillion achievable with optimized configuration) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports FDA 21 CFR Part 11 audit trails (with optional software package), GLP/GMP-ready architecture |
| Output Options | Configurable digital (RS-485, Ethernet/IP, Modbus TCP) and analog (4–20 mA, 0–10 V) outputs |
| Sample Interface | Valco®-sourced high-integrity pneumatic valves, Sulfinert®/Silcosteel®-passivated flow paths, electropolished stainless-steel manifolds |
| Calibration | Automated on-board calibration with user-defined schedules, NIST-traceable standard gas integration |
| Data Handling | OPC UA server integration, automated daily maintenance logging, CSV/Excel export via embedded web interface |
| Form Factor | Rack-mountable (19″ 4U chassis) or standalone industrial enclosure (NEMA 4X rated) |
| Support | Lifetime remote diagnostics and application engineering support included |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Valco |
| Pricing | Available Upon Request |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | VICI Valco Full Line |
| Pricing | Available Upon Request |
| Brand | VICI |
|---|---|
| Origin | USA |
| Model | Valco HP2 |
| Gas Compatibility | He, Ar, Ne, Kr, Xe, Rn |
| Max Operating Pressure | 1000 psi |
| Impurity Removal Limit | <10 ppb (H₂O, H₂, O₂, N₂, CO, NO, NH₃, CO₂) |
| Excluded Gases | He, Ar, Ne, Kr, Xe, Rn (i.e., does not remove carrier gas itself) |
| Heating Control | Integrated thermal regulation system |
| Certification | CE compliant |
| Power Options | 110 VAC or 230 VAC |
| Replacement Cartridge Part No. | MNK283165 (He) |
| Mounting | In-line upstream of GC inlet |
| Brand | VICI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VICI Micro Diaphragm Valve Series |
| Pricing | Available Upon Request |