| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop/Free-Standing ED-XRF Spectrometer |
| Application Field | Non-Ferrous Metals & Precious Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit for Ag/Cu | ≤10 ppm |
| Quantitative Accuracy | ±0.001% for Au (99.999 wt%) |
| Detector | Large-Area Silicon Drift Detector (SDD) |
| Excitation Geometry | Vertical Beam Path Configuration |
| Compliance | ASTM E1621, ISO 8256, GB/T 17724–2022, RoHS Directive 2011/65/EU |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ScopeX G59 |
| Configuration | Benchtop |
| Instrument Type | Conventional ED-XRF Spectrometer |
| Industry-Specific Application | Non-Ferrous Metals (Precious Metals) |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | ≤10 ppm for Ag and Cu |
| Quantitative Accuracy | ±0.001% for Au in AU99999-grade material |
| Detector | Large-Area Silicon Drift Detector (SDD) |
| Optical Geometry | Vertical Beam Path |
| Sample Chamber | Extra-Large, Accommodates Irregular & High-Volume Specimens |
| Excitation Source | Rhodium Anode Microfocus X-ray Tube |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | ScopeX G59 |
| Configuration | Benchtop/Floor-Standing |
| Instrument Type | Conventional ED-XRF |
| Industry-Specific Application | Non-Ferrous Metals (Precious Metals) |
| Elemental Range | Al (13) to U (92) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | ScopeX PG6 |
| Form Factor | Benchtop/Floor-Standing |
| Instrument Type | Conventional ED-XRF |
| Industry-Specific Application | Non-Ferrous Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | ppm-level |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | ScopeX PG7 |
| Price Range | USD 14,000 – 42,500 (FOB) |
| Form Factor | Benchtop |
| Instrument Type | Conventional ED-XRF |
| Industry-Specific Application | Non-Ferrous Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Sub-ppm to % level (matrix-dependent) |
| Safety Compliance | IEC 62495, GB/Z 25488–2010, EN 61000-6-3 |
| Software | ScopeX Suite v3.2 (with audit trail, user-level permissions, CFR Part 11 ready) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | SHINE Metal Corrosion Edition |
| Instrument Type | Powder X-ray Diffractometer |
| Power Supply | Integrated Low-Power X-ray Source (Details in Technical Datasheet) |
| Detector | CCD-based 2D X-ray Detector |
| Connectivity | USB 3.0, Bluetooth 5.0, Wi-Fi 802.11ac |
| Sample Mass Requirement | ~20 mg per analysis |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic |
| Model | SHINE Soil Edition |
| Instrument Type | Powder X-ray Diffractometer |
| Power Supply | As specified in technical documentation |
| Anode Target Options | Cu or Co |
| Detector | CCD-based 2D X-ray detector |
| Sample Requirement | ~20 mg per analysis |
| Connectivity | USB, Bluetooth, Wi-Fi |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SHINE REX900 |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano (BB) |
| Portability | Fully Integrated Ruggedized Enclosure |
| Radiation Safety | Fully Shielded, Zero Leakage During Operation |
| Data Output Formats | Excel, PDF |
| Connectivity | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11ac |
| Software | CrystalX — Automated Phase Identification & Quantification Engine |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | TrueX 200S |
| Application | Handheld/Portable |
| Instrument Type | Conventional |
| Industry-Specific Type | General-Purpose |
| Elemental Range | Mg–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TrueX 700 |
| Application | Handheld / Portable |
| Instrument Type | General-Purpose EDXRF |
| Industry-Specific Use | Soil & Atmospheric Environmental Monitoring |
| Elemental Analysis Range | Sodium (Na, Z=11) to Uranium (U, Z=92) |
| Brand | LANScientific |
|---|---|
| Model | TrueX 700 Series |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable/Handheld EDXRF Spectrometer |
| Application Field | Environmental Soil & Sediment Screening |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD (for major elements under standardized conditions) |
| Detector | High-resolution silicon drift detector (SDD), Peltier-cooled, 25 mm² active area |
| Sample Form Compatibility | Solids, powders, filter residues, slurries (dried or semi-dry), thin films, particulates, and heterogeneous field-collected matrices |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | TrueX 860 |
| Application | Handheld / Portable |
| Instrument Type | General-Purpose ED-XRF Spectrometer |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | Sub-ppm to ppm level (matrix-dependent) |
| Compliance | CE, RoHS, FCC, ISO 17025-aligned operation |
| Weight | <1.5 kg |
| Battery Life | ≥8 hours typical usage |
| Safety | Automatic beam shutter, radiation interlock, real-time dose monitoring per IEC 62495 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable/Handheld ED-XRF |
| Models | TrueX 880, TrueX 880S, TrueX 980, TrueX 980S |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantitative Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD (for major elements under standardized conditions) |
| Compliance | CE, RoHS, ISO 12885, ASTM E1621, ASTM E2857 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | TrueX G7 |
| Price Range | USD 14,000 – 42,500 |
| Form Factor | Handheld / Portable |
| Instrument Type | Benchtop-Portable Hybrid ED-XRF |
| Industry-Specific Design | Non-Ferrous & Precious Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | Sub-ppm to % level (matrix-dependent) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TX3000 Series (Portable) |
| Instrument Type | Total Reflection XRF (TXRF) |
| Application Scope | Soil & Atmospheric Analysis |
| Sample Form Compatibility | Liquid, Suspension, Solid, Particulate Deposits |
| Regulatory Alignment | Compliant with ISO 8519, ASTM D7706 (for trace metal analysis in environmental matrices), GLP-ready data handling |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TX3000 Series |
| Configuration | Handheld / Portable |
| Instrument Type | Total-Reflection X-Ray Fluorescence (TXRF) |
| Application Domain | Soil & Atmospheric Analysis |
| Compliance Context | ASTM D6919, ISO 17294-2, USP <232>/<233>, EPA Method 6020B (adapted for field TXRF) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TX3000 |
| Application | Portable/Field-Deployable |
| Instrument Type | Total Reflection XRF (TXRF) |
| Industry-Specific Use | Soil & Atmospheric Analysis |
| Elemental Range | Mg (12) to U (92) |
| Detection Range | 30 ppb – 100 ppm |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | TX3300 Series |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) |
| Application Form Factor | Handheld / Portable |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | 20 pg/mL (ppb) in liquid matrix |
| Sample Consumption | ≤ 10 µL per analysis |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Industry Focus | Energy & Chemicals |
| Compliance Context | Designed for GLP-compliant trace metal quantification in regulated environmental and industrial labs |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TX3300 |
| Application | Portable/Field-Deployable |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | 20 pg/mL (ppb) in liquid matrix |
| Detector | 20 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | TX3300Cl |
| Application | Handheld/Portable |
| Instrument Type | Total-Reflection X-Ray Fluorescence (TXRF) |
| Industry-Specific Use | Energy & Chemical Engineering |
| Elemental Range | Mg (12) to U (92) |
| Detection Range | 0.3 ppm – 100 ppm |
| Detector | Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TX3300TI |
| Application | Handheld/Portable |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) Spectrometer |
| Industry-Specific Use | Energy & Chemical Engineering |
| Detection Limit | Sub-ppb (ng/L) for Thallium |
| Sample Volume | Microliter-scale (μL) |
| Analysis Time | ≤2 min per sample (no digestion, no calibration required) |
| Optical Design | High-efficiency TXRF geometry with ultra-low background |
| Compliance Support | Designed for ASTM D8139, ISO 17294-2, and China’s HJ 657–2013 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Total Reflection XRF (TXRF) |
| Element Range | Mg–U |
| Detection Limit | 0.1 ppb – 100 ppm |
| Detector | 65 mm² Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YANG 700 |
| Pricing | Upon Request |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-3 Microcoulometric Halogen Analyzer |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion (900–1100 °C) |
| Applicable Standards | GB/T 34845–2017, GB/T 22904–2008, GB/T 35613–2017, GB/T 39084–2020, GB/T 35611–2017, GB/T 41533–2022 |
| Detection Target | Adsorbable Organic Halogens (AOX), expressed as Cl⁻ |
| Detection Limit | 2 mg/kg |
| Quantification Range | 0.5–5 mg/kg (Cl) |
| Precision | ±1 µg Cl |
| Repeatability | ≤10% RSD at ≤2 mg/L sample concentration |
| Combustion Temperature Control | 500–1100 °C, ±1 °C accuracy |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment | 0–500 mV, continuously adjustable |
| Sample Introduction | 50 mg ±5 mg activated carbon cartridge |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Interface | RS-232 (DB9) |
| Software Platform | Windows-based proprietary AOX analysis suite with real-time parameter monitoring, data logging, audit trail, and report generation (PDF/CSV export) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 (PRC National Ecological and Environmental Standard) |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ±1 µg Cl |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Control Range | 500–1100 °C |
| Stability | ±1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion |
| Compliance | HJ 1214–2021 (China National Standard) |
| Maximum Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Precision | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Loading | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 |
| Detection Principle | Microcoulometric Titration |
| Max Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 mg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ≤10% relative deviation (at 1 µg Cl) |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C control accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANYO |
|---|---|
| Model | SOMA Series |
| Standard Compliance | NY/T 1121.6–2006, NY/T 85–1988, LY/T 1237–1999, GB/T 33469–2016 Annex C |
| Heating Stations | 3 independent micro-boiling reflux positions with PID temperature control |
| Reagent Dispensing Accuracy | ≤0.3% (v/v) |
| Titration Endpoint Detection | Biomimetic colorimetric endpoint recognition |
| Reagent Port | 1 dedicated channel with isolated fluid path |
| Tube Cleaning | Programmable pre-run automated line rinse and conditioning cycle |
| Software Interface | Integrated GUI with real-time process logging, CSV export, and LIMS-compatible data transmission protocol |
| Safety | Fully enclosed reagent handling |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LARRY-USB3648 |
| Pricing | Available Upon Request |