Empowering Scientific Discovery

Hangzhou Zhuochi Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-WK-S
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C (±1% ±5 °C)
Accuracy<5%
Repeatability<5%
Limit of Detection (LOD)0.1 µg/L
ComplianceHJ 1214–2021 (China National Standard for AOX in Water)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhochi
OriginZhejiang, China
ModelAOX-3
Measurement PrincipleHigh-Temperature Combustion Coupled with Coulometric Titration
Quantification Range5–1000 mg sample mass
Accuracy±1%
Repeatability≤1% RSD
Detection Limit0.8–1000 µg/L (as AOX)
Resolution0.01 µg
Max Operating Temperature1150 °C
Temperature Uniformity±1 °C
Heating RateAdjustable up to 50 °C/min
Furnace Chamber DimensionsØ40 × 300 mm
Power Supply220 V, 50 Hz, 1.5 kW
Net Weight26 kg
ComplianceHJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelAOX-WK-S
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C
Temperature Accuracy±1% ±5 °C
Measurement Accuracy<5%
Repeatability<5%
LOD0.1 µg/L
ComplianceHJ 1214–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAOX-S
PricingUpon Request
Measurement PrincipleCombustion–Microcoulometric Titration
Furnace Temperature Range500–1000 °C
Temperature Accuracy±1% ±5 °C
Measurement Accuracy<5%
Repeatability<5%
Limit of Detection (LOD)0.1 µg/L (as Cl⁻ equivalent)
ResolutionNot specified
Added to wishlistRemoved from wishlist 0
Add to compare
KeyPrinciple: High-Temperature Combustion + Microcoulometric Titration
Range0.8–1000 µg/L
Accuracy±1%
Repeatability≤1%
LOD0.8 µg/L
Resolution0.01 µg
Max Temp1150 °C
Temp Stability±1 °C
Furnace Zone200 mm
Power1.5 kW, 220 V/50 Hz
Dimensions345×360×660 mm
Weight26 kg
ComplianceHJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-S Zhuochi
Measurement PrincipleCombustion-Microcoulometric Titration
Temperature Range500–1000 °C (±1 % ±5 °C)
Accuracy<5 %
Repeatability<5 %
Limit of Detection0.1 µg/L
ComplianceHJ 1214–2021 (China EPA Standard for Water Quality — Determination of Adsorbable Organic Halogens by Microcoulometry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
ModelAOX-WK-S
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C (±1% ±5 °C)
Accuracy<5%
Repeatability<5%
Detection Limit0.1 µg/L
ComplianceHJ 1214–2021 (China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
ModelAOX-WK-S
ApplicationWater Quality Analysis
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C (±1% ±5 °C)
Accuracy<5%
Repeatability<5%
LOD0.1 µg/L
ComplianceHJ 1214–2021 (China EPA Standard)
OriginZhejiang, China
Supplier TypeAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
ModelAOX-WK-S
ApplicationAdsorbable Organic Halogens (AOX) in Water
Measurement PrincipleCombustion-Microcoulometric Titration
Temperature Range500–1000 °C (±1% ±5 °C)
Accuracy<5%
Repeatability<5%
Detection Limit0.1 µg/L
ComplianceHJ 1214–2021 (China EPA Standard)
OriginZhejiang, China
Supplier TypeAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-1000
Measurement PrincipleCombustion-Coulometric Titration
Measurement Range5–1000 µg/L (as Cl⁻)
Accuracy±1%
Repeatability (RSD)≤1%
Detection Limit0.8–1000 µg/L
Resolution0.01 µg
ComplianceDesigned to meet ISO 9562 and EPA Method 1650 requirements for AOX determination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAOX-3
PriceUSD 3,950 (FOB)
Detection PrincipleHigh-Temperature Combustion Coupled with Microcoulometric Titration or Ion Chromatography
Detection Range0.8–1000 µg/L (as Cl⁻ equivalent)
Accuracy±1%
Repeatability (RSD)≤1%
Detection Limit0.8 µg/L
Resolution0.01 µg
Max Combustion Temperature1150 °C
Temperature Control Stability±1 °C
Heating RateAdjustable up to 50 °C/min
Furnace Chamber DimensionsØ40 × 300 mm
Power Supply220 V, 50 Hz, 1.5 kW
Net Weight26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
KeyPrinciple: Combustion–Microcoulometric Titration
Temperature Range500–1000 °C
Accuracy<5%
Repeatability<5%
LOD0.1 µg/L
Temp. Control Precision±1% ±5 °C
OriginZhejiang, China
BrandZhuochi
ModelAOX-WK-S
ComplianceHJ 1214–2021
Added to wishlistRemoved from wishlist 0
Add to compare
KeyPrinciple: Combustion–Microcoulometric Titration
Temperature Range500–1000 °C, ±1% ±5 °C
Accuracy<5%
Repeatability<5%
LOD0.1 µg/L
OriginZhejiang, China
ComplianceHJ 1214–2021 (PRC Environmental Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-S
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C (±1% ±5 °C)
Accuracy<5%
Repeatability<5%
Limit of Detection (LOD)0.1 µg/L
ComplianceDesigned per HJ 1214–2021 (China National Standard for AOX in Water)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-3 Standard
Measurement PrincipleHigh-Temperature Combustion Coupled with Coulometric Titration
Detection Range0.8 μg/L to 1000 μg/L
Accuracy<1%
Repeatability<10%
Limit of Detection (LOD)0.1 μg
Resolution0.01 μg
Max Combustion Temperature1150 °C
Sample IntroductionPressurized Nitrogen-Driven Column Adsorption (5–1000 mg)
Analysis Time (Combustion & Detection)3–10 min (excluding pre-concentration)
Required GasesO₂ ≥99.6% (99.999% recommended), N₂ for adsorption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOCHI
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelZC-AOX
PriceUSD 4,200 (FOB Zhejiang)
Measurement PrincipleCombustion–Coulometric Titration
Measurement Range5–1000 µg AOX per sample
Accuracy±1% of reading
Repeatability (RSD)≤1%
Detection Limit0.8–1000 µg/L (sample-dependent)
Resolution0.01 µg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOCHI
OriginZhejiang, China
ModelZC-AOX-3
Measurement PrincipleCombustion-Coulometric Titration
Measurement Range5–1000 µg
Accuracy±1%
Repeatability≤1% RSD
Detection Limit0.8–1000 µg/L
Resolution0.01 µg
ComplianceDesigned for ASTM D5907, ISO 9562, and EPA Method 1650
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandZhochi
OriginZhejiang, China
ModelAOX-3
Detection PrincipleHigh-Temperature Combustion Coupled with Coulometric Titration or Ion Chromatography
Temperature Range100–1150 °C
Max. Temp. Stability±1 °C
炉 Chamber DimensionsØ40 × 300 mm
Power Supply220 V, 50 Hz
Rated Power1.5 kW
Sample Mass Range5–1000 mg
Detection Range0.8–1000 µg/L
LOD0.8 µg/L
Accuracy±1%
Repeatability≤1%
Resolution0.01 µg
Avg. Analysis Time (combustion only)3–10 min
Gas RequirementsO₂ ≥99.6% (99.999% recommended)
ComplianceHJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAOX-WK-S
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500 °C to 1000 °C, ±1% ±5 °C
Accuracy<5%
Repeatability<5%
LOD0.1 µg/L
ComplianceHJ 1214–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
ModelAOX-WK-S
ApplicationDetermination of Adsorbable Organic Halogens (AOX) in Water Samples
Measurement PrincipleCombustion–Microcoulometric Titration
Temperature Range500–1000 °C, ±1% ±5 °C
Accuracy<5%
Repeatability<5%
Limit of Detection (LOD)0.1 µg/L
ComplianceHJ 1214–2021 (China EPA Standard)
OriginZhejiang, China
Supplier TypeAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
KeyPrinciple: Combustion–Microcoulometric Titration
Temperature Range500–1000 °C
Accuracy<5%
Repeatability<5%
LOD0.1 µg/L (as Cl⁻ equivalent)
ComplianceGB/T 34845-2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-3
Detection PrincipleHigh-Temperature Combustion–Microcoulometric Titration
Measurement Range0.8–1000 µg/L
Accuracy±1%
Repeatability≤1% RSD
Detection Limit0.8 µg/L
Resolution0.01 µg
Combustion TemperatureUp to 1150 °C
Furnace Temperature Stability±1 °C
Heating RateAdjustable up to 50 °C/min
Furnace Chamber DimensionsØ40 × 300 mm
Power Supply220 V, 50 Hz, 1.5 kW
Net Weight26 kg
ComplianceHJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-3
Detection PrincipleHigh-Temperature Combustion Coupled with Microcoulometric Titration
Detection Range0.8–1000 µg/L
Accuracy±1%
Repeatability≤1% RSD
LOD0.8 µg/L
Resolution0.01 µg
Max Combustion Temperature1150 °C
Furnace Temp Control Stability±1 °C
Heating RateAdjustable up to 50 °C/min
Furnace Chamberφ40 × 300 mm
Power Supply220 V, 50 Hz, 1.5 kW
Net Weight26 kg
Dimensions (W×D×H)345 × 360 × 660 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhuochi
OriginZhejiang, China
ModelAOX-ZC
Measurement PrincipleCombustion–Coulometric Titration
Measurement Range5–1000 µg
Accuracy±1%
Repeatability≤1% RSD
Detection Limit0.8–1000 µg/L
Resolution0.01 µg
ComplianceDesigned for EPA Method 1613, ISO 9562, DIN 38409-H17, and ASTM D5908
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0