Empowering Scientific Discovery

Hunan Zhenhua Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
ModelDRL-III
Measurement PrincipleHeat Flow Method
Thermal Conductivity Range0.010–50 W/m·K
Accuracy±3%
Repeatability±1%
Temperature RangeAmbient to 200 °C (Hot Plate), 0–99.99 °C (Cold Plate)
Sample DiameterØ10–30 mm
Sample Thickness0.02–20 mm
Thermal Resistance Range5×10⁻⁶ – 0.05 m²·K/W
Pressure Range0–1000 N
Displacement Resolution0.01 mm
Dimensions (L×W×H)60 cm × 58 cm × 90 cm
Compliance StandardsASTM E1530, ASTM C518, ISO 8301, DIN EN 12939, DIN EN 13163, DIN EN 12667, JIS A 1412
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelHWX-II
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelDRX-II-300A
Price RangeUSD 7,000–14,000
Instrument TypeGuarded Hot Plate Method
Measurement Range0.01–2.2 W/m·K
Repeatability±1.0%
Accuracy±2.5%
Thickness CapacityUp to 200 mm
Cold Plate Temp Range−40 °C to +60 °C
Hot Plate Temp RangeAmbient to 110 °C (optional up to 300 °C or 600 °C)
Temperature Control Precision±0.1 °C
Temp Resolution0.01 °C
Sample Size200 × 200 × (5–20) mm or 300 × 300 × (5–100) mm
Power SupplyAC 220 V ±5%, 3.0 kW
ComplianceGB/T 10294–2008, ASTM C518, ISO 8302
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
ModelDRX-II-JG
Measurement PrincipleLaser Flash Method (LFA)
Temperature RangeRT to 1000 °C
Thermal Diffusivity Range0.01–1000 mm²/s
Thermal Conductivity Range0.1–1000 W/(m·K)
Accuracy±3%
Repeatability±2% (thermal diffusivity), ±3% (specific heat)
Sample FormsSolid, Powder, Liquid, Film, Composite, Ceramic, Metal, Graphite, Polymer
Atmosphere OptionsAmbient air, inert gas, oxidizing/reducing gas, vacuum (down to 10⁻³ Pa)
Sample DimensionsØ12–20 mm or ≥10×10 mm, thickness 0.1–10 mm (recommended 3 mm)
DetectionInfrared detector (non-contact)
Data Acquisition Rate2 MHz
Software PlatformWindows 10 (64-bit), GLP-compliant reporting, ASTM E2585 / ISO 22007-4 / GB/T 22588 / GJB 1201.1-91 compliant
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelDRX-II-LUX
PriceUpon Request
Measurement PrincipleSteady-State Guarded Hot Plate (Modified ASTM C177 / ISO 8302 compliant architecture)
Heat Plate DiameterΦ65 mm
Heat Plate Temp60 ± 0.1 °C (Pt100 controlled)
Cold Plate Temp20 ± 0.1 °C (water-cooled, Pt100 controlled)
Preheater Temp40 °C (optional)
Coolant Temp Control20 ± 0.5 °C
Coolant Flow Rate40 L/h
Temperature Differential Resolution±0.1 °C (via differential thermopile or dual Pt100)
Sample DimensionΦ50 × 50 mm
Thickness Measurement Accuracy±0.01 mm (digital caliper)
Test Duration5–20 min
Contact PressureManual or motorized preloading system
Max Power Consumption≤1.5 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDRH-600
Instrument TypeGuarded Hot Plate Method
Sample CapacitySingle specimen
Test EnvironmentAmbient pressure
Thermal Conductivity Range0.0015–3.0 W/m·K
Accuracy±3%
Repeatability±1%
Temperature Range (Cold Plate)0–99.9 °C
Temperature Range (Hot Plate)Ambient to 99.9 °C
Specimen Dimensions (Max)600 × 600 × 200 mm
Specimen Flatness Tolerance≤0.5 mm
Thickness Measurement Range0–200 mm
Thickness Resolution0.01 mm
Applied Pressure Range0–1000 N
Pressure Resolution0.1 N
Temperature Resolution0.01 °C (Cold Plate), 0.1 °C (Hot Plate)
Power SupplyAC 220 V ±5%, 3.0 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
ModelHDRX-RL03
Measurement PrincipleHeat Flow Meter (HFM) Method
Thermal Conductivity Range0.001–5 W/(m·K)
Accuracy±3%
Repeatability≤3%
Temperature RangeRT to 1000 °C
Sample Thickness Range0.5–60 mm
Thickness Resolution1 µm
Thickness Accuracy±0.01 mm
Applied Pressure Range0–3.0 MPa
Pressure Accuracy<0.5% FS
Cold-Side Cooling10 L Precision Circulating Bath (−5 to 80 °C, 0.01 °C resolution)
Hot-Side ControlPID-regulated heating with multi-point real-time temperature monitoring
Compliance StandardsASTM C518, ASTM E1530, ISO 22007-2
Data Acquisition32-bit high-resolution ADC, modular architecture supporting specific heat and thermal diffusivity expansion modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
ModelDRX-II-SPB
PrincipleHeat Flow Meter Method (HFMM)
Temperature Range600–1600 °C
Thermal Conductivity Range0.001–5 W/(m·K)
Accuracy±3%
Repeatability±3%
Sample FormSolid disk (φ119 mm × 35–45 mm)
Atmosphere ControlInert gas (N₂, Ar) or vacuum (≤1000 Pa)
Pressure Control0–0.1 MPa
Heating ElementMolybdenum rod
CoolingExternal recirculating chiller
SensorImported U.S. heat flux transducer
ComplianceGB/T 10295, GB/T 17911.8-2002, YB/T 4130-2005
Dimensions (L×W×H)1300×800×1450 mm
Power Supply220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDRX-I-SPB
Instrument TypeGuarded Hot Plate Method (Water-Cooled)
Continuous Sample Capacity1–3 stacked layers
Test EnvironmentHigh-Temperature Atmosphere (up to 1400 °C)
Dimensions (L×W×H)1500 mm × 650 mm × 1120 mm
Thermal Conductivity Range0.015–2.7 W/(m·K)
Accuracy±3%
Repeatability±1%
Temperature RangeAmbient to 1400 °C
Sample FormSolid slabs or bricks (standard: Ø180 mm × 50 mm or ≤230 mm × 230 mm × 65 mm)
Heating Power ControlAdjustable, computer-regulated
Water Flow Rate10 g/s (temperature-stabilized coolant loop)
Total Power Consumption≤4.5 kW
Operating SystemWindows 10 / 7 / XP
Electrical Supply220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelHPA-300
Price RangeUSD 7,000–14,000
Instrument TypeHeat Flow Method
Dimensions (L×W×H)750 × 650 × 1100 mm
Accuracy±3%
Thermal Conductivity Range0.015–100 W/(m·K)
Repeatability±1%
Maximum Test Temperature300 °C
Applied Load Range0–1000 N (adjustable)
Specimen Sizeφ50 × 100 mm or φ37.5 × 100 mm
Cooling Base Temperature20 °C (integrated constant-temperature water bath)
Axial Temperature Sensors4 points
Radial Temperature Sensors3–6 gradient points
Heating Power60 W
SoftwareFully Automated Acquisition & Analysis Suite with Touchscreen Interface
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelDRH300
QuotationUSD 7,650 (FOB)
Instrument TypeGuarded Hot Plate Method
Dimensions (L×W×H)1200 × 700 × 1300 mm
Accuracy±3%
Thermal Conductivity Range0.005–3.0 W/(m·K)
Repeatability1%
Temperature Control Range (DRH300A/B/C variants)0–40 °C / RT–100 °C / −20–70 °C
Sample Size Max300 × 300 × 100 mm
Thermal Resistance Range0.1–8.0 m²·K/W
Control SystemPeltier-based heated/cooled plates with dual embedded heat flux sensors
ComplianceASTM C518, ISO 8301, GB/T 10294, GB/T 10295, JIS A 1412, DIN EN 12939, DIN EN 13163, DIN EN 12667
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelJRWS
Price RangeUSD 7,000–14,000
Instrument TypeTransient Hot Wire Method
Dimensions (L×W×H)190 × 95 × 140 mm
Accuracy±3%
Thermal Conductivity Range0.01–10 W/m·K
Repeatability±2%
Temperature Control Range5–85 °C
Temperature Measurement Error≤±0.1 °C
Resolution0.01 °C
Thermal Diffusivity Stability Requirement≤±1 °C (entire test), ≤±0.5 °C (steady-state phase)
Specific Heat Capacity Range0.5–5.0 kJ/(kg·K)
Specimen GeometryØ200 mm × 400 mm cylinder with central Ø40 mm through-hole
Water Bath Temp Range10–80 °C
Heating Rate0.5–1.0 °C/min
Strain MeasurementResistance strain gauge, 250 mm gauge length, resolution 0.1 με
Power SupplyAC 220 V ±10%, 50–60 Hz, ≤6 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
ModelGHR-3K
Measurement PrincipleSteady-State Cylindrical Guarded Hot Pipe Method (per GB/T 10296–2008 & ISO 8497:1994)
Thermal Conductivity Range0.05–80 W/(m·K)
Accuracy±3%
Repeatability±2%
Test Temperature RangeAmbient to 350 °C
Sample FormCylindrical tubular insulation shells (e.g., rubber-plastic, fiberglass, rock wool, glass wool pipes)
Specimen DimensionsOuter diameter up to 25 mm, length 500 mm, metering section 200 mm, guard sections 150 mm each
Heating Power0–500 W (adjustable constant-current source, ±0.5% stability)
Environmental Control Precision±1 °C
Guard Zone Temperature Control Precision±1 °C
Data Acquisition16-bit multi-channel thermocouple input card
Software InterfaceWindows-based control, real-time monitoring, automated calculation of thermal conductivity (λ), surface thermal resistance (Rₛ), and heat transfer coefficient (h)
ComplianceFully aligned with GB/T 10296–2008 and ISO 8497:1994 requirements for steady-state thermal transmission characterization of cylindrical insulation systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDRX-II-PS
Instrument PrincipleTransient Plane Source (TPS) Method
Sample ThroughputSingle-sample mode
Test EnvironmentAmbient pressure
Dimensions (L×W×H)750 × 400 × 600 mm
Accuracy±3%
Thermal Conductivity Range0.005–500 W/m·K
Repeatability±3%
Temperature Range OptionsRoom temperature to 200 °C / 600 °C / 1000 °C (user-selectable configuration)
Measurement Duration1–160 s
Sample Thickness0.1–5 mm
Power SupplyAC 220 V, ≤500 W
InterfaceRS232/USB for PC communication
SoftwareIntegrated TPS analysis suite with automated reporting and ASTM/ISO-compliant data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
ModelDRH-300C
Measurement PrincipleGuarded Hot Plate Method (ASTM C177 / ISO 8302)
Thermal Conductivity Range0.001–2.7 W/m·K
Accuracy±3%
Repeatability±1%
Temperature Control Range−20 °C to 70 °C
Sample Thickness15–100 mm (auto-measured, 0.1 mm resolution)
Sample Size300 mm × 300 mm
ComplianceASTM C518, ISO 8301, GB/T 10295, EN 1946-3:1999
Cooling OptionsForced air, external water bath, or Peltier-based electronic cooling
SoftwarePC-based automated data acquisition, real-time thermal resistance calculation, report generation, and GLP-compliant audit trail (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHCX09A
PricingAvailable Upon Request
Thermal Conductivity Range0.05–20 W/(m·K)
Temperature Measurement AccuracyBetter Than Class 0.2
Measurement Uncertainty±3%
Heating Power Control Resolution±1%
Sample GeometryCylindrical, Ø15–30 mm × 5–30 mm
Temperature & AtmosphereCustomizable per User Specification
Data AcquisitionFully Automated via PC Interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
ModelDRH-300
Measurement PrincipleGuarded Hot Plate Method (ASTM C177, ISO 8302)
Test EnvironmentAmbient Temperature (18–25 °C, 20–80% RH)
Dimensions (L×W×H)1100 × 900 × 1300 mm
Thermal Conductivity Range0.001–2.2 W/(m·K)
Accuracy±3%
Repeatability±1%
Temperature Control Precision±0.1 °C (Hot Plate & Cold Plate)
Sample Thickness5–50 mm
Sample Size Options200 × 200 mm or 300 × 300 mm
Power SupplyAC 220 V ±5%, 3.0 kW
SoftwareWindows-based Automated Thermal Analysis Suite (English & Chinese UI)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelDRX-I-JH
PricingAvailable Upon Request
Max Operating TemperatureRT–600°C / RT–1000°C (configurable)
Thermal Conductivity Range0.035–40 W/(m·K) and 20–500 W/(m·K) (material-dependent)
Sample GeometryCylindrical rods (Ø5 × 220 mm for metals
Wire SamplesØ1–3 mm diameter
Sample Quantity≥2 per test run
Measurement Accuracy≤5% (typical), down to ±2% under optimized calibration and controlled conditions
Vacuum/Atmosphere ControlCustomizable (high-vacuum or inert gas purge options)
AutomationFully computer-controlled heating ramping, data acquisition, real-time calculation, and report generation
Power Supply220 V AC, ≤4 kW total consumption
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeDistributor
Product OriginDomestic
ModelDRX-II-RW
Price RangeUSD 7,000–14,000
Instrument TypeHeat Flow Method
Dimensions (L×W×H)550 × 450 × 780 mm
Accuracy±3%
Thermal Conductivity Range0.5–100 W/(m·K)
Repeatability≤±1%
Specific Heat Measurement Accuracy±7%
Thermal Diffusivity Measurement Accuracy±5%
Operating Temperature Range20–300 °C
Sample Diameter15–50 mm
Sample Thickness1–50 mm
Compliance StandardsGB 5598–1985, GB 11205–1989, MIL-I-49456A, ASTM D5470–06
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDRX-I-RX
Price RangeUSD 1,400–7,200 (FOB)
Instrument TypeTransient Hot Wire Method (THW)
Dimensions (L×W×H)110 × 150 × 65 cm
Accuracy±5%
Thermal Conductivity Range0.015–20 W/(m·K)
Repeatability±2%
Max Test Temperature1000 °C / 1400 °C / 1600 °C (configurable)
Sample Size Limit230 × 114 × 65 mm
Heating Power ControlProgrammable & Computer-Regulated
Dual-Mode CapabilityCross-Wire & Parallel-Wire THW
Software PlatformWindows 7/XP-based thermal analysis application with automated data acquisition and report generation
Optional ModulesSpecific Heat Capacity Measurement Module (accuracy: ±7–10%), Transient Line Source (TLS), and Needle Probe Method Adapters
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelDRX-II-RL
PricingAvailable Upon Request
Temperature Range Options−196 °C to RT, −30 °C to 90 °C, −20 °C to 70 °C, 0 °C to 40 °C, 0 °C to 100 °C
Temperature Resolution0.01 °C
Sample DiameterΦ10–30 mm
Sample Thickness0.02–50 mm
Thermal Resistance Range0.1–8.0 m²·K/W
Thermal Conductivity Range0.015–100 W/(m·K) and 0.015–40 W/(m·K)
Accuracy≤±3% (thermal conductivity), ±5% (thermal diffusivity), ±7% (specific heat)
Repeatability0.3–0.5%
Cooling OptionsForced-air, External Water Bath, Liquid Nitrogen
ControlMotorized Plate Actuation, Programmable Temperature Ramp (1–10 setpoints), Embedded Controller + PC Interface
Compliance StandardsASTM D5470-06, ASTM E1530, ASTM C518, ISO 8301, JIS A1412, DIN EN 12939, DIN EN 13163, DIN EN 12667, MIL-I-49456A
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelDRH-300
Price RangeUSD 7,000–14,000
Instrument TypeGuarded Hot Plate Method
Dimensions (L×W×H)820 × 760 × 950 mm
Accuracy±2%
Thermal Conductivity Range0.001–2.20 W/(m·K)
Repeatability±1%
Sample Thickness Range5–50 mm
Sample Size300 × 300 mm
Cold Plate Temp. Range0–60 °C (0.01 °C resolution)
Hot Plate Temp. Range10–99.9 °C
Temperature Uniformity (Hot/Cold Plates)≤0.1 °C
Surface Flatness Tolerance≤0.5 mm
Applied Pressure Range0–80 kPa (0.1 kPa resolution)
Power SupplyAC 220 V ±5%, 3.0 kW
Added to wishlistRemoved from wishlist 0
Add to compare
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelRPT-II
PricingAvailable Upon Request
Temperature RangeAmbient to 1000 °C
Temp. Accuracy±0.1 °C
Heating Rate0–10 °C/min
Cooling OptionsNatural & Controlled
Sample DimensionsØ4×100 mm, Ø6×100 mm, Ø8×100 mm
Expansion Measurement Range0–5 mm
Expansion Resolution0.1 µm/digit
Expansion Accuracy±0.1% FS
Test ModulesThermal Expansion Coefficient (CTE), Electrical Conductivity, Thermal Conductivity, Resistivity
Control & AnalysisIndustrial PC–Based Automated Software Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHENHUAFENXI
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDRX-II
Instrument TypeHeat Flow Method
Sample CapacitySingle sample per test
Test EnvironmentAmbient pressure
Thermal Conductivity Range0.015–50 W/(m·K)
Accuracy±3%
Repeatability±2%
Dimensions (L×W×H)550×500×850 mm
Temperature RangeRT to 200 °C
Sample FormSolid (rigid or flexible sheets, discs, composites)
Standards ComplianceASTM E1530, ASTM C518, ISO 8301, JIS A1412, DIN EN 12939, DIN EN 13163, DIN EN 12667, MIL-I-49456A
SoftwareIntegrated automated thermal analysis platform with calibration management, temperature ramp programming, and GLP-compliant reporting