Industry-specific Instruments
Filter
Showing 3181–3210 of 6456 results
| Brand | Labthink |
|---|---|
| Model | RT-01 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application | Ink adhesion, coating abrasion resistance, print rub fastness testing |
| Compliance | ASTM D5264, TAPPI T830 |
| Load Options | 8.9 N (2 lb) and 17.8 N (4 lb) |
| Stroke Frequency | 21, 42, 85, 106 cycles per minute (cpm) |
| Motion Type | Arcuate reciprocating |
| Cycle Count Range | 0–999,999 |
| Sample Capacity | 1–2 specimens |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 485 × 390 × 230 mm |
| Net Weight | 40 kg |
| Control System | Microprocessor-based with PVC membrane keypad and LCD display |
| Test Modes | Dry rub, wet rub, migration, wet trace |
| Memory Function | Power-loss cycle retention |
| Audible Alert | Built-in buzzer for test completion |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | RT-01 |
| Pricing | Upon Request |
| Friction Load | 8.9 N (2 lb) / 17.8 N (4 lb) |
| Friction Speed | 21 / 42 / 85 / 106 cycles per minute (cpm) |
| Motion Profile | Arcuate reciprocating |
| Cycle Range | 0–999,999 |
| Specimen Capacity | 1–2 specimens |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 485 × 390 × 230 mm |
| Net Weight | 40 kg |
| Compliance | ASTM D5264, TAPPI T830 |
| Brand | Labthink |
|---|---|
| Model | SBG-80T |
| Light Source | CIE D65-compliant 6500 K fluorescent tube (D6500 high-CRI super fluorescent lamp) |
| Viewing Area | 400 × 250 mm |
| Illuminance on Glass Surface | ~1000 lux |
| Ambient Light Requirement | 20–50 lux |
| Magnification | 100× |
| Minimum Scale Division | 0.01 mm |
| Power Supply | 220 VAC, 50 Hz / 120 VAC, 60 Hz |
| Dimensions (L×W×H) | 800 × 600 × 230 mm |
| Net Weight | 10 kg |
| Compliance | GB/T 3198, GB/T 22638.2, YBB 00152002–2015, CIE S 002:2022 (CIE D65 illuminant), CY3–91 |
| Brand | Labthink |
|---|---|
| Model | SBG-80T |
| Light Source | CIE D65-compliant 6500 K fluorescent tube |
| Observation Area | 400 × 250 mm |
| Illuminance on Glass Surface | ~1000 lux |
| Ambient Illuminance Requirement | 20–50 lux |
| Magnification | 100× |
| Minimum Scale Division | 0.01 mm |
| Color Rendering Index (CRI) | ≥95 |
| Light Uniformity | ±5% across observation area |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 800 × 600 × 230 mm |
| Net Weight | 10 kg |
| Compliance Standards | GB/T 3198, GB/T 22638.2, YBB 00152002–2015, CY3–91, CIE S 002:2022 |
| Brand | Labthink |
|---|---|
| Model | SBG-80T |
| Light Source | CIE D65-compliant 6500 K fluorescent lamp (D6500 high-CRI super daylight tube) |
| Viewing Area | 400 × 250 mm |
| Illuminance on Glass Surface | ~1000 lux |
| Ambient Illuminance Requirement | 20–50 lux |
| Magnification | 100× |
| Minimum Scale Division | 0.01 mm |
| Color Rendering Index (CRI) | ≥95 |
| Light Uniformity | ±5% across viewing area |
| Power Supply | 220 VAC, 50 Hz / 120 VAC, 60 Hz |
| Dimensions (L×W×H) | 800 × 600 × 230 mm |
| Net Weight | 10 kg |
| Compliance | GB/T 3198, GB/T 22638.2, YBB 00152002–2015, CY3–91, CIE S 002:2022 (Standard General Lighting Conditions for Visual Assessment) |
| Brand | Labthink |
|---|---|
| Model | Strip Sampler-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Sample Width | 15 mm (customizable) |
| Sample Length | < 600 mm |
| Number of Strips per Cut | 11 (customizable) |
| Max. Sample Thickness | < 2 mm |
| Compatible Materials | Paper, Flexible Plastic Films |
| Dimensions (L×W×H) | 350 × 300 × 290 mm |
| Net Weight | 15 kg |
| Power Requirement | None (Manual Operation Only) |
| Blade Type | Imported High-Hardness Steel Blade |
| Compliance | GB/T 1040.3–2006, ISO 527–3:1995 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TQD-G1A |
| Price Range | USD 14,000 – 70,000 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Rate Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 50 mm × 50 mm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Interface | RS232 serial port |
| Display | 7-inch industrial color touch screen |
| Compliance Standards | ISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, ASTM D737, TAPPI T460, JIS P8117 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TQD-G1A |
| Price Range | USD 14,000 – 42,000 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Air Flow Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 5 cm × 5 cm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Interface | RS232 |
| Display | 7″ industrial color touchscreen |
| Compliance Standards | ISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, ASTM D737, TAPPI T460, JIS P8117 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TQD-G1A |
| Pressure Differential Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Rate Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 5 cm × 5 cm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable) |
| Dimensions (W×D×H) | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TQD-G1A |
| Price Range | USD 14,000 – 70,000 |
| Measurement Principle | Constant-Pressure-Difference (Method B) & Constant-Flow-Rate (Method A) |
| Standards Compliance | ISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, ASTM D737, TAPPI T460, JIS P8117 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Rate Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 50 mm × 50 mm |
| Max Sample Thickness | 1 mm |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions (W×D×H) | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TQD-G1A |
| Price Range | USD 14,000 – 42,000 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Airflow Range | 0–30 L/min |
| Airflow Resolution | 0.1 L/min |
| Airflow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 5 cm × 5 cm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz (selectable) |
| Dimensions (W×D×H) | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Compliance Standards | ISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, ASTM D737, TAPPI T460, JIS P8117 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Labthink-TQD-G1A |
| Price Range | USD 14,000 – 70,000 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Rate Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 5 cm × 5 cm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Interface | RS232 |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 300 × 460 × 520 mm |
| Net Weight | 25 kg |
| Brand | Labthink |
|---|---|
| Model | TQD-G1A |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application Scope | Paper, paperboard, nonwovens, automotive interior materials (PU foam, PVC, leather, textiles), membranes, sponges, carpets, masks |
| Test Methods | ISO 9237 (Method A & B), ASTM D737, GB/T 5453, TAPPI T460, JIS P8117 |
| Pressure Drop Range | 0–1000 Pa |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.25% FS |
| Flow Range | 0–30 L/min |
| Flow Resolution | 0.1 L/min |
| Flow Accuracy | ±2% FS |
| Test Area | 20 cm² (standard, customizable) |
| Sample Size | 50 mm × 50 mm |
| Max Sample Thickness | 1 mm |
| Gas Supply | Clean compressed air (user-supplied, ≥550 kPa, >120 L/min) |
| Power | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 300 × 460 × 520 mm |
| Weight | 25 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VAC-V1(EX) |
| Price Range | USD 14,000 – 70,000 |
| Testing Principle | Differential Pressure (Manometric) Method |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Temperature Control Range | 5–95 °C (±0.1 °C stability) |
| Vacuum Resolution | 0.1 Pa |
| Test Chamber Vacuum Level | ≤10 Pa |
| Sample Area | 38.48 cm² (Ø97 mm) |
| Gas Permeation Range | 0.05–50,000 cm³/m²·24h·0.1MPa (extendable to ≥500,000 cm³/m²·24h·0.1MPa) |
| Test Gases | O₂, N₂, CO₂, H₂, air, He |
| Operating Pressure Differential | 10–200 kPa |
| Gas Inlet | Ø6 mm polyurethane tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 500 × 575 × 450 mm (L×W×H) |
| Net Weight | 50 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VAC-V2 |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VAC-V2 |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0%RH, 5–90%RH (optional active humidification at 15–40 °C) |
| Humidity Accuracy | ±1%RH |
| Vacuum Resolution | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Sample Size | Ø97 mm |
| Effective Test Area | 38.48 cm² |
| Gas Permeability Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Number of Independent Test Cells | 3 |
| Test Gases | O₂, N₂, CO₂, air, He (custom modification required for flammable/explosive gases) |
| Test Pressure Range | 10–200 kPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | RS232 serial port |
| Data Management | Lystem™ Laboratory Data Sharing System |
| Power Supply | 220 VAC/50 Hz or 120 VAC/60 Hz |
| Dimensions (L×W×H) | 760×575×450 mm |
| Net Weight | 88 kg |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (extendable to ≥500,000 cm³/m²·24h·0.1MPa) |
| Specimen Count | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator) |
| Humidity Accuracy | ±1% RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (L×W×H) | 760 × 575 × 450 mm |
| Weight | 88 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB00082003 |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He, etc. |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Specimen Count | 3 independent test cells |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (humidification module optional) |
| Humidity Accuracy | ±1% RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | –0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (L×W×H) | 760 × 575 × 450 mm |
| Weight | 88 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038–2000, JIS K7126-1, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He, etc. |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Capacity | 3 independent test chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0%RH, 2–98.5%RH, 100%RH (humidifier optional) |
| RH Accuracy | ±1%RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Weight | 88 kg |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Count | 3 independent test chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional humidity generator) |
| Humidity Accuracy | ±1%RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Interface | RS232 |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB00082003 |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure (ASTM D1434, ISO 15105-1, GB/T 1038-2000) |
| Test Gases | N₂, O₂, CO₂, Air, He (customizable for flammable/explosive gases) |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (expandable to ≥500,000 cm³/m²·24h·0.1MPa) |
| Independent Test Chambers | 3 |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional humidity generator) |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Sample Area | 38.48 cm² |
| Sample Diameter | Φ97 mm |
| Power Supply | 220VAC 50Hz / 120VAC 60Hz |
| Net Weight | 88 kg |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Principle | Differential Pressure Method |
| Test Gases | O₂, N₂, CO₂, H₂ |
| Standard Compliance | GB/T 1038-2000, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126, YBB00082003 |
| Measurement Range | 0.05–50,000 cm³/m²·24h·0.1MPa (extendable to ≥500,000 cm³/m²·24h·0.1MPa) |
| Test Chambers | 3 independent |
| Vacuum Resolution | 0.1 Pa |
| Vacuum Level in Test Chamber | <20 Pa |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional humidifier) (±1%RH) |
| Specimen Size | Φ97 mm |
| Effective Permeation Area | 38.48 cm² |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Data Interface | RS232 |
| Software Integration | Lystem™ Laboratory Data Management System |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Measurement Principle | Differential Pressure Method |
| Test Gases | O₂, N₂, CO₂, Air, He (customizable for flammable/explosive gases) |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Capacity | 3 independent test chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0%RH, 5–90%RH (optional auto-humidification at 15–40 °C) |
| Humidity Accuracy | ±1%RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Range | 10–200 kPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Power | 220VAC 50Hz / 120VAC 60Hz |
| Weight | 88 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | VAC-V2 |
| Price Range | USD 14,000 – 85,000 (FOB Qingdao) |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB00082003 |
| Test Gases | O₂, N₂, CO₂ (user-supplied gas sources) |
| Permeation Range | 0.05–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Specimen Count | 3 independent test cells |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator required) |
| Humidity Accuracy | ±1% RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (L×W×H) | 760 × 575 × 450 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 88 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Labthink VAC-V2 |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential Pressure (ASTM D1434 / ISO 15105-1 / GB/T 1038-2000) |
| Test Gases | O₂, N₂, CO₂ (user-supplied) |
| Measurement Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Chamber Count | 3 independent test chambers |
| Vacuum Resolution | 0.1 Pa |
| Minimum Test Chamber Vacuum | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator required) |
| Humidity Accuracy | ±1% RH |
| Sample Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (L×W×H) | 760 × 575 × 450 mm |
| Weight | 88 kg |
| Power | AC 220 V, 50 Hz |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 PERME |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 85,000 (FOB Qingdao) |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB00082003 |
| Measurement Parameters | Oxygen (O₂), Nitrogen (N₂), Carbon Dioxide (CO₂), Sulfur Hexafluoride (SF₆), and other non-corrosive gases |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Specimen Capacity | 3 independent test cells |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (humidification module optional) |
| Humidity Accuracy | ±1% RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | –0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (L×W×H) | 760 × 575 × 450 mm |
| Weight | 88 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Principle | Differential Pressure Method (ASTM D1434, ISO 15105-1, GB 1038) |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Temperature Control | 5–95 °C, ±0.1 °C |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional humidity generator required) |
| Humidity Accuracy | ±1%RH |
| Vacuum Accuracy | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Sample Diameter | Φ97 mm |
| Sample Quantity | 3 independent test cells |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂, CH₄ (CH₄-compatible configuration available with modified gas handling system) |
| Test Pressure Range | –0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Weight | 88 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-A, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Principle | Differential Pressure Method |
| Test Gases | O₂, N₂, CO₂ |
| Test Range | 0.05–50,000 cm³/m²·24h·0.1MPa (expandable to ≥500,000) |
| Sample Capacity | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional generator) (±1%RH) |
| Sample Diameter | Φ97 mm |
| Effective Area | 38.48 cm² |
| Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply | 0.4–0.6 MPa via Φ6 mm polyurethane tubing |
| Power | 220VAC 50Hz / 120VAC 60Hz |
| Weight | 88 kg |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB00082003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | VAC-V2 |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Pressure-difference (manometric) method |
| Measurable Gases | O₂, N₂, CO₂, air, He, H₂, CH₄ (with optional safety modification) |
| Test Parameters | Gas Transmission Rate (GTR), Solubility Coefficient (S), Diffusion Coefficient (D), Permeability Coefficient (P) |
| Independent Test Chambers | 3 |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Lower Chamber Vacuum Level | <20 Pa |
| Standard Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038–2000, YBB 00082003 |
| Sample Area | 38.48 cm² |
| Sample Diameter | Φ97 mm |
| Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Interface | RS232 |
| Data System | Lystem™ Laboratory Data Management Platform |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 88 kg |
| Dimensions | 760 × 575 × 450 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | VAC-V2-PERME |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Measurement Range | 0.05–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Count | 3 independent test stations |
| Vacuum Resolution | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 5°C–95°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Control Range | 0%RH, 2–98.5%RH, 100%RH (humidity generator optional) |
| Humidity Accuracy | ±1%RH |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂ (gas supply user-provided) |
| Test Pressure Differential | −0.1 MPa to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Interface | Ø6 mm polyurethane tubing |
| Data Output | RS232 serial interface |
| Software Integration | Lystem™ Laboratory Data Sharing System |