Industry-specific Instruments
Filter
Showing 3091–3120 of 6502 results
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C690B |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method |
| Compliant Standards | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 kPa |
| Chamber Capacity | 1 unit, max sample size Φ45 mm × 80 mm |
| Gas Supply | Compressed air (user-supplied), ≥40.6 PSI (500 kPa) |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 250 × 330 × 440 mm |
| Power | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable) |
| Net Weight | 10 kg |
| Data Traceability | NIST-traceable pressure sensors |
| Software Compliance Options | 21 CFR Part 11 electronic signatures, GMP audit trail, multi-level user permissions |
| Brand | Labthink |
|---|---|
| Model | C690B |
| Principle | Vacuum Decay Method |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Test Range | 3–8 µm (USP <1207> reference orifice) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 kPa |
| Chamber Dimensions | ≤Φ45 mm × 80 mm |
| Sample Capacity | 1 unit per test |
| Air Supply | Compressed air ≥500 kPa (60 psi), Φ6 mm polyurethane tubing |
| Power | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions (W×D×H) | 250 × 330 × 440 mm |
| Weight | 10 kg |
| Interface | 12.1″ industrial touchscreen, USB port, optional thermal printer |
| Data Traceability | NIST-traceable pressure sensor, audit trail, optional 21 CFR Part 11 electronic signature and GMP-compliant software modules |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Principle | Vacuum Decay Method |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Test Range | 3–8–Large Leak (Reference Orifice, USP <1207>) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per batch |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed Air (≥500 kPa / 72.5 psi) |
| Interface | Ø6 mm Polyurethane Tubing |
| Power | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 850 × 500 × 730 mm |
| Weight | 95 kg |
| Vacuum Source | Integrated European Vacuum Pump |
| Data Traceability | NIST-Traceable Pressure & Flow Sensors |
| Software Platform | Windows-based Embedded OS with 15.6" Touchscreen |
| Optional Compliance Modules | 21 CFR Part 11 Electronic Signatures, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Vacuum Decay |
| Test Method | ASTM F2338–22, YY/T 0681.18–2022, USP <1207> |
| Sample Capacity | 20–120 units per batch |
| Test Chamber | Dual independent chambers (A & B) |
| Sample Size Limit | ≤ Φ45 mm × 80 mm |
| Pressure Range | –100 to +100 kPa |
| Detection Limit | ≤ 3 µm (equivalent reference orifice per USP <1207>) |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Gas Supply | Compressed air (user-supplied, ≥500 kPa / 72.5 psi) |
| Interface | Φ6 mm polyurethane tubing |
| Power Supply | 120 VAC ±10% 60 Hz OR 220 VAC ±10% 50 Hz (configurable) |
| Dimensions | 850 × 500 × 730 mm (W×D×H) |
| Net Weight | 95 kg |
| Compliance Options | Optional 21 CFR Part 11 electronic signature & audit trail module |
| Brand | Labthink |
|---|---|
| Model | C690H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Vacuum Decay Method (ASTM F2338–21 compliant) |
| Test Range | 3–8–Large Leak (USP <1207> Reference Orifice Equivalent) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | –100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per batch |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Interface | Ø6 mm Polyurethane Tubing |
| Dimensions | 850 × 500 × 730 mm |
| Weight | 95 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Operating System | Embedded Windows on 15.6" Touchscreen |
| Data Compliance | 21 CFR Part 11–ready Electronic Signatures, Audit Trail, Role-Based User Access Control |
| Software Features | Real-time Pressure Curve Visualization, Automatic Pass/Fail Classification, Leakage Rate & Equivalent Orifice Diameter Calculation, Auto-Capture & Sorting of Non-Conforming Units, USB & Ethernet Connectivity, Remote Firmware Updates |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Labthink C690H |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method |
| Standards Compliant | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 3–8–Large Leak (USP <1207> Reference Orifice) |
| Detection Limit | ≤3 µm |
| Resolution | 0.1 µm |
| Repeatability | ±1 µm |
| Pressure Range | −100 to 0 to +100 kPa |
| Sample Capacity | 20–120 units per run |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Brand | Labthink |
|---|---|
| Model | C690M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Positive Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent orifice size) |
| Pressure Range | −100 to +100 kPa |
| Test Chamber | 1 unit, swing-arm auto-sealing design |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-provided), ≥500 kPa (72.5 PSI) |
| Air Inlet | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Control System | 12.1″ embedded Windows touch panel PC |
| Data Traceability | NIST-traceable pressure sensors |
| Software Compliance | 21 CFR Part 11–ready audit trail, electronic signature, role-based user permissions |
| Optional | Integrated oil-free European vacuum pump, custom test fixtures, certified leak standards (positive/negative controls), GMP-compliant computer system validation package |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent leak size) |
| Pressure Range | −100 to +100 kPa |
| Chamber | Single transparent swing-arm sealed chamber |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-supplied, ≥500 kPa / 72.5 psi) |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10% 60 Hz OR 220 VAC ±10% 50 Hz (configurable) |
| Control System | 12.1" embedded Windows touch panel |
| Data Traceability | NIST-traceable pressure sensors |
| Software Features | Real-time pressure curve, auto-leak quantification, statistical reporting, USB/Ethernet connectivity, remote firmware update |
| Regulatory Support | 21 CFR Part 11 compliant electronic signatures, multi-level user permissions, audit trail, GMP-compliant validation documentation |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay Method (ASTM F2338 compliant) |
| Dual-Mode Operation | Vacuum & Positive Pressure |
| Test Chamber | Swing-arm Auto-Clamping with Rapid Interchange |
| Target Vacuum Level | User-Configurable |
| Viewing Window | Transparent Acrylic Test Chamber |
| Vacuum Source | Optional Oil-Free European Vacuum Pump (NIST-Traceable Calibration Supported) |
| Pressure Sensor Technology | High-Stability Digital Transducer |
| Microflow Control | Automated Precision Flow Regulation |
| Data Traceability | Full Audit Trail, NIST-Referenced Calibration |
| Compliance | 21 CFR Part 11 Electronic Signatures, GMP Data Integrity Requirements, USP <1207>, YY/T 0681.18 |
| Operating System | Embedded Windows on 12.1" Touchscreen |
| Test Resolution | 0.1 mPa·s equivalent (leak rate), ±1 µm equivalent leak size repeatability |
| Test Range | Equivalent to 2–8 µm laser-drilled reference leaks (per USP <1207> guidance) |
| Max Sample Dimensions | Ø45 mm × 80 mm |
| Pressure Range | –100 to +100 kPa |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Net Weight | 26 kg |
| Footprint | 300 mm × 560 mm × 370 mm |
| Air Supply Requirement | Compressed air ≥500 kPa (72.5 PSI), Ø6 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | C690M |
| Pricing | Upon Request |
| Test Principle | Vacuum Decay & Pressure Decay |
| Standards Compliance | ASTM F2338, YY/T 0681.18, USP <1207> |
| Detection Range | 2–8 µm (USP <1207> reference orifice scale) |
| Detection Limit | ≤2 µm |
| Resolution | 0.1 mPa·s (pressure-based equivalent) |
| Repeatability | ±1 µm (equivalent leakage orifice) |
| Pressure Range | −100 to +100 kPa |
| Test Chamber | 1 unit, swing-arm auto-sealing |
| Max Sample Size | Ø45 mm × 80 mm |
| Gas Supply | Compressed air (user-provided), ≥500 kPa (72.5 PSI) |
| Interface | Ø6 mm polyurethane tubing |
| Dimensions (W×D×H) | 300 × 560 × 370 mm |
| Weight | 26 kg |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Control System | 12.1" embedded Windows touch panel |
| Data Traceability | NIST-traceable pressure sensors, audit trail, electronic signature per 21 CFR Part 11 |
| Software Features | Real-time pressure curve display, automatic leak rate calculation, statistical reporting, USB/Ethernet connectivity, remote firmware update |
| Optional | GMP-compliant computer system validation package, integrated oil-free European vacuum pump, custom test fixtures, certified negative/positive reference standards |
| Brand | Labthink |
|---|---|
| Model | C840H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Model | C840H |
| Principle | Gravimetric Method |
| Standards Compliance | USP <641>, YBB00342002-2015, YBB00132002-2015, ISO 759-1981, GB 31604.8-2016, GB/T 5009.60, GB/T 9740 |
| Test Capacity | 25 stations |
| Cup Volume | 100 mL |
| Weight Range | 0.05–10,000 mg (standard), up to 80,000 mg (optional) |
| Resolution | 0.01 mg (standard), 0.1 mg (optional) |
| Repeatability | ±0.05 mg (standard), ±0.3 mg (optional) |
| Temperature Control Range | Ambient to 130 °C |
| Temperature Stability | ±0.5 °C |
| Cooling Method | Liquid-cooled rapid cooling system |
| Gas Supply | Compressed air ≥500 kPa (72.5 PSI), Φ8 mm polyurethane tubing |
| Power Input | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz (user-selectable) |
| Dimensions (W×D×H) | 83 cm × 110 cm × 73 cm |
| Net Weight | 200 kg |
| Display | 12.1" medical-grade touchscreen |
| Data Compliance | 21 CFR Part 11–compliant electronic signatures, audit trail, role-based user permissions |
| Connectivity | Embedded Ethernet port for remote control, firmware updates, and network integration |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C840H |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Model | C840H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Model | C840M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Test Range | 0.3–80,000 mg (standard) |
| Resolution | 0.1 mg (standard) |
| Repeatability | ±0.3 mg (standard) |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.5 °C |
| Test Stations | 12 |
| Cup Volume | 100 mL |
| Gas Supply | Compressed air (user-supplied) |
| Tubing Interface | Φ8 mm polyurethane |
| Dimensions (W×D×H) | 630 × 1050 × 730 mm |
| Power | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (configurable) |
| Net Weight | 180 kg |
| Compliance Standards | ISO 1135-4:2015, ISO 1135-5:2015, ISO 3826-1:2019, ISO 3826-4:2015, ISO 8536-4:2019, EN 1186-3, GB 31604.8–2016, GB/T 5009.60, YBB00342002–2015, YBB00132002–2015, ISO 759:1981, ISO 6353-1:1982, GB/T 9740 |
| Brand | Labthink |
|---|---|
| Model | C850H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | C860M |
| Price Range | USD 14,000 – 98,000 |
| Brand | Labthink |
|---|---|
| Model | CHY-C2A |
| Measurement Principle | Mechanical Contact Profilometry |
| Load Range | 0–2 mm (standard), 0–6 mm / 12 mm (optional) |
| Resolution | 0.1 µm |
| Measurement Speed | 10 tests/min (adjustable) |
| Contact Area | 50 mm² (film), 200 mm² (paper/board) |
| Applied Pressure | 17.5 ± 1 kPa (films), 50 ± 1 kPa (paper/board) |
| Compliance | ISO 4593, ISO 534, ISO 3034, GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D374, ASTM D1777, TAPPI T411, JIS K6250, JIS K6783, JIS Z1702, BS 3983, BS 4817 |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions | 461 × 334 × 357 mm (L×W×H) |
| Net Weight | 32 kg |
| Interface | RS232 |
| Data Management | Lystem™ Laboratory Data Sharing System |
| Calibration | Traceable standard gauge block included |
| Brand | Labthink |
|---|---|
| Model | CLASSIC 216 |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Number of Independent Test Cells | 3 |
| Vacuum Resolution | 0.1 Pa |
| Minimum Test Chamber Vacuum | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required for precise isothermal operation) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidification system optional) |
| Specimen Area | 38.48 cm² (Ø97 mm) |
| Pressure Differential Range | –0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Power Supply | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Dimensions (L×W×H) | 670 × 540 × 430 mm |
| Net Weight | 75 kg |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038–2000, YBB 00082003–2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CLASSIC 216 |
| Price Range | USD 14,000 – 57,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003-2015 |
| Test Gases | O₂, N₂, CO₂, He, air |
| Measurement Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Number of Test Cells | 3 (independent) |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane |
| Dimensions (L×W×H) | 670 × 540 × 430 mm |
| Weight | 75 kg |
| Power Supply | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CLASSIC 216 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Measurement Range | 0.1–50,000 cm³/m²·24h·0.1MPa (standard) |
| Test Stations | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidification module optional) |
| Specimen Area | 38.48 cm² (Φ97 mm) |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas sources, 0.4–0.6 MPa inlet pressure) |
| Pressure Differential | –0.1 to +0.1 MPa |
| Power Supply | AC 220 V 50 Hz / AC 120 V 60 Hz |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Net Weight | 75 kg |
| Compliance Standards | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003-2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | CLASSIC216 |
| Price Range | USD 14,000 – 85,000 |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄ |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1MPa (standard) |
| Specimen Count | 3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Pressure Differential | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Weight | 75 kg |
| Power | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Brand | Labthink |
|---|---|
| Model | CLASSICA-216 |
| Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂, Air, He |
| Test Range | 0.1–50,000 cm³/m²·24h·0.1 MPa (standard) |
| Vacuum Resolution | 0.1 Pa |
| Chamber Vacuum Level | <20 Pa |
| Temperature Control Range | 15–55 °C (external chiller/heater required) |
| Humidity Control Options | 0% RH, 100% RH, or intermediate levels per ASTM E104 (humidity generator optional) |
| Specimen Area | 38.48 cm² |
| Specimen Diameter | Φ97 mm |
| Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.4–0.6 MPa |
| Interface | Φ6 mm polyurethane tubing |
| Dimensions | 670 × 540 × 430 mm (L×W×H) |
| Weight | 75 kg |
| Power | AC 220 V / 50 Hz or AC 120 V / 60 Hz |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038–2000, YBB 00082003–2015 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | COF-P01 |
| Angle Range | 0°–85° |
| Angular Resolution | 0.01° |
| Angular Speed | 0.1°/s–10.0°/s |
| Standard Slider Mass | 1300 g |
| Optional Slider Masses | 200 g, 235 g (custom masses available) |
| Operating Environment | 23±2°C, 20–70% RH |
| Dimensions (L×W×H) | 440×305×200 mm |
| Weight | 20 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliance | ASTM D202, ASTM D4918, TAPPI T815 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DV-Series (Modular Platform) |
| Price Range | USD 14,000 – 70,000 |
| Brand | Labthink |
|---|---|
| Model | FIT-01 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Impact Energy Range | 1 J, 2 J, 3 J (standard) |
| Resolution | 0.001 J |
| Impactor Tip Diameter | Φ25.4 mm, Φ19 mm, Φ12.7 mm (customizable) |
| Clamp Aperture | Φ89 mm, Φ60 mm |
| Specimen Size | 100 mm × 100 mm or Φ100 mm |
| Pneumatic Supply Pressure | 0.6 MPa (user-supplied) |
| Air Hose Interface | Φ6 mm polyurethane tubing |
| Dimensions (L×W×H) | 600 mm × 390 mm × 600 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 64 kg |
| Compliance | GB/T 8809–2014, ASTM D3420–2008a, NF T54-116–1973 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FPT-F1 |
| Test Force Range | 0–5 N / 0–10 N / 0–30 N |
| Accuracy Class | 0.5 |
| Standard Slider Masses | 200 g, 500 g (optional: 100 g, 1000 g, 1814 g, 2000 g) |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Temperature Control Range | Ambient to 99.9 °C |
| Power Supply | AC 220 V 50 Hz / AC 120 V 60 Hz |
| Dimensions (L×W×H) | 850 × 350 × 290 mm |
| Net Weight | 30 kg |
| Compliance | ISO 8295, ISO 8510-2, GB 10006, GB/T 2790–2792, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549 |
| Brand | Labthink |
|---|---|
| Model | FPT-F1 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Test Range | 0–5 N / 0–10 N / 0–30 N |
| Accuracy Class | 0.5 |
| Slider Mass Options | 200 g, 500 g (custom: 100 g, 1000 g, 1814 g, 2000 g) |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Temperature Control Range | Ambient to 99.9 °C |
| Power Supply | AC 220 V 50 Hz / AC 120 V 60 Hz |
| Dimensions (L×W×H) | 850 × 350 × 290 mm |
| Net Weight | 30 kg |
| Compliance Standards | ISO 8295, ISO 8510-2, GB 10006, GB/T 2790–2792, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549 |
| Brand | Labthink |
|---|---|
| Model | FPT-F1 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 7,000 – 14,000 |
| Test Modes | Static & Kinetic COF, 180° Peel |
| Load Capacity | 0–5 N / 0–10 N / 0–30 N |
| Accuracy | Class 0.5 |
| Slider Masses | 200 g, 500 g (optional: 100 g, 1000 g, 1814 g, 2000 g) |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Temperature Range | Ambient to 99.9 °C |
| Power Supply | AC 220 V 50 Hz / AC 120 V 60 Hz |
| Dimensions (L×W×H) | 850 × 350 × 290 mm |
| Net Weight | 30 kg |
| Compliance | ISO 8295, ISO 8510-2, GB 10006, GB/T 2790, GB/T 2791, GB/T 2792, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549 |
| Brand | Labthink |
|---|---|
| Model | FT-F1 |
| Temperature Range (Hot Chamber) | Ambient to 150 °C (up to 280 °C optional) |
| Temperature Stability (Hot Chamber) | ±0.1 °C at 150 °C |
| Temperature Range (Cold Chamber) | 0–100 °C |
| Temperature Stability (Cold Chamber) | ±0.1 °C |
| Compliance | ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G |
| Measurement Methods | Gloss Reduction (standard), Haze Increase (optional), Gravimetric Condensate Mass (standard, balance not included) |