Industry-specific Instruments
Filter
Showing 5251–5280 of 6072 results
| Brand | Timepower |
|---|---|
| Model | TP725 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Application | Petroleum, Power, Chemical, Inspection & Research Laboratories |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Kinematic Viscosity Resolution | 0.00001 mm²/s |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max Power Consumption | ≤1500 W |
| Dimensions | 370 × 300 × 650 mm |
| Weight | ~28 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP737 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Model | TP737 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Application Standard | ASTM D7042 / GB/T 17144–1997 |
| Temperature Range | 0.0–1372 °C |
| Temp. Resolution | 0.1 °C (≤999.9 °C), 1 °C (>999.9 °C) |
| Temp. Accuracy | ±0.2% of reading |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2 kW |
| Dimensions (H×W×D) | 500 × 400 × 360 mm |
| Weight | Approx. 32 kg |
| Gas Requirement | High-purity N₂ (≥99.99%), regulated pressure ≥0.08 MPa |
| Safety Features | Overtemperature alarm (520 °C), low-N₂-pressure interlock, insulated furnace housing, ergonomic heat-shielded lid handle |
| Brand | Timepower |
|---|---|
| Model | TP737 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2 kW |
| Dimensions (H×W×D) | 500 mm × 400 mm × 360 mm |
| Temperature Range | 0.0–1372 °C |
| Temp. Resolution | 0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C) |
| Temp. Accuracy | ±0.2% of reading |
| Operating Ambient | ≤30 °C, RH 10–70% |
| Storage Temp. | −25 to +55 °C |
| Sample Tube Capacity | Dual-size (large & small) |
| Data Storage | 100 test records with date-stamped retrieval |
| Gas Requirement | High-purity N₂, min. pressure 0.08 MPa |
| Safety Alerts | Overtemp (≥520 °C), Low N₂ pressure (<0.08 MPa), Thermal hazard warnings |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP737 |
| Pricing | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤ 2 kW |
| Dimensions (H×W×D) | 500 mm × 400 mm × 360 mm |
| Temperature Range | 0.0 °C to 1372 °C |
| Temperature Resolution | 0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C) |
| Temperature Accuracy | ±0.2% of reading |
| Operating Ambient Temperature | ≤30 °C |
| Relative Humidity | 10–70% RH |
| Storage/Transport Temperature | –25 °C to +55 °C |
| Sample Tube Types | Large & Small Crucibles |
| Gas Supply | Nitrogen, Minimum Pressure: 0.08 MPa |
| Safety Alarms | Overtemperature (>520 °C), Low N₂ Pressure (<0.08 MPa) |
| Data Storage | 100 test records with date-stamped retrieval |
| Control Interface | 5-inch TFT color touchscreen |
| Operating System | Embedded real-time OS |
| Heating Control | Programmable ramp/soak profile |
| Residue Calculation | Automatic mass-based %CR determination |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP755 |
| Pricing | Upon Request |
| Measurement Principle | Vibrating Tube (Oscillating U-tube) |
| Density Range | 0–1999.9 kg/m³ |
| Alcohol Concentration Range | 0–100% vol |
| Accuracy | ±0.5 kg/m³ (±0.0005 g/cm³) |
| Temperature Control | 20 °C ±0.1 °C (Dual-Chamber Thermostatic Bath) |
| Sample Volume | 2 mL per measurement (auto- or manual aspiration) |
| Sample Throughput | Up to 80 stored measurements |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions | 265 × 210 × 205 mm |
| Weight | 3.4 kg |
| Ambient Operating Temperature | 5–40 °C |
| Wetted Materials | Acid/alkali-resistant fluoropolymer tubing (standard optional), general-purpose PTFE/PFA tubing |
| Calibration Standard | Certified pure water (ASTM D1250-compliant procedure recommended) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP791 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP791 |
| Pricing | Upon Request |
| Light Source | Semiconductor Laser |
| Measurement Principle | Light Obscuration (ISO 11171, ISO 4402 compliant) |
| Particle Size Range | 0.8 µm to 500 µm (sensor-dependent) |
| Detection Channels | 8 programmable channels |
| Adjustable Channel Thresholds | Within calibrated size range per selected standard |
| Sample Volume Range | 0.2–1000 mL |
| Sampling Flow Rate | 5–80 mL/min |
| Resolution | <10% (per ISO 21501-4) |
| Coincidence Limit | 10,000 particles/mL |
| Maximum Positive Pressure (Chamber) | 0.8 MPa |
| Maximum Negative Pressure (Chamber) | 0.08 MPa |
| Ambient Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤200 W |
| Dimensions (W×D×H) | 390 × 340 × 660 mm |
| Weight | 23.5 kg |
| Data Output | Built-in thermal printer + RS232 serial interface |
| Calibration Standards Supported | GJB-420B, NAS 1638, ISO 4406, GOCT 17216 |
| Custom Standard Programming | Yes |
| Sample Introduction | Precision syringe pump + dual-pressure (positive/negative) chamber for degassing and viscous fluid handling |
| Integrated Air Filtration System | HEPA-class internal purification |
| Display & Interface | Color touchscreen with Chinese-language UI, on-device data storage, automated grade classification per selected standard |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP791 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | TP791 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP791 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP791 |
| Pricing | Upon Request |
| Light Source | Semiconductor Laser |
| Measurement Principle | Light Obscuration (LO) per ISO 11171 & ISO 4402 |
| Measurement Range | 0.8 µm to 500 µm (sensor-dependent) |
| Number of Detection Channels | 8 (user-definable size thresholds within calibration range) |
| Sample Volume | 0.2–1000 mL (programmable) |
| Flow Rate | 5–80 mL/min |
| Resolution | <10% (per ISO 21501-4) |
| Coincidence Limit | 10,000 particles/mL |
| Pressure Chamber | +0.8 MPa (positive), –0.08 MPa (negative) |
| Data Output | Built-in thermal printer + RS232 serial interface |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤200 W |
| Dimensions | 390 × 340 × 660 mm |
| Weight | 23.5 kg |
| Compliance Standards | GJB-420B, NAS 1638, ISO 4406, GOCT 17216 (built-in) |
| Sample Compatibility | Hydraulic oils, lubricants, transformer oil, turbine oil, gear oil, engine oil, jet fuel (Jet A/A-1), water-glycol fluids, polymer solutions, and other non-aqueous organic liquids |
| Calibration | Multi-point NIST-traceable reference standards |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP791 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP825 |
| Pricing | Available Upon Request |
| Display | LCD |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | ≤1500 W |
| Dimensions (W×D×H) | 320 mm × 440 mm × 600 mm |
| Weight | 30 kg |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Kinematic Viscosity Measurement Range | 0.75–27,000 mm²/s |
| Viscosity Resolution | 0.00001 mm²/s |
| Bath Volume | ~10 L |
| Test Positions | 4 independent capillary viscometer stations |
| Real-time Clock | Yes (battery-backed, retains time during power loss) |
| Sample Types | Transparent and opaque liquids including crude oil, fuel oils (light/heavy), lubricants, additives, and used oils |
| Brand | Timepower |
|---|---|
| Model | TP825 / TP725 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | ASTM D445, ISO 3104, GB/T 265-1988 |
| Temperature Control Method | PID-controlled Constant-Temperature Bath |
| Capillary Selection | Auto-recognized or user-defined Ubbelohde-type viscometers |
| Data Output | Automatic kinematic viscosity (mm²/s), flow time (s), and calculation per standard algorithms |
| Reporting | CSV and PDF export with audit trail metadata |
| Regulatory Support | GLP-compliant operation log, user access levels, and electronic signature-ready workflow |
| Brand | TimePower |
|---|---|
| Model | TIMEPOWER582 |
| Standard Compliance | ASTM D130, ASTM D4048, ISO 6251, GB/T 5096, GB/T 7326, SH/T 0232, SH/T 0023 |
| Temperature Range | Ambient to 150 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Main Heating Power | 600 W |
| Auxiliary Heating Power | 1000 W |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timer Range | 1 min – 24 h (user-programmable) |
| Sample Positions | 4 independent test cells |
| Max. Simultaneous Samples | 12 (via sequential batch processing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions | 480 × 360 × 520 mm |
| Net Weight | 18 kg |
| Operating Humidity | ≤85% RH (non-condensing) |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | 20 kN Pneumatic Grip |
| Actuation Pressure | 80 psi (5.5 bar) |
| Maximum Clamping Force | 40 kN |
| Jaw Face Dimensions | 25 mm × 50 mm |
| Control | Foot-Operated Valve |
| Jaw Type | Dual-Pneumatic, Centerline-Aligned |
| Initial Clamping Force | Spring-Preloaded |
| Compatibility | Tinius Olsen ST-Series Dual-Column Universal Testing Machines |
| Integration Capability | Yes — Compatible with Automated Test Systems |
| Jaw Face Interchangeability | Yes — Multiple Standard & Custom Face Options Available |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | 603HDTV, 303HDTV |
| Compliance Standards | ISO 75-1/2, ISO 306, ASTM D648, ASTM D1525 |
| Maximum Simultaneous Test Positions | 6 (603HDTV), 3 (303HDTV) |
| Oil Bath Stations | 6 (603HDTV), 3 (303HDTV) |
| Load Application | Pneumatic vertical loading with air-bearing guide ring |
| Displacement Resolution | 0.001 mm |
| Load Accuracy | Certified for 0.45 MPa (ISO 75) and 1.0 MPa / 5.0 MPa (ISO 306) |
| Cooling System | Integrated heat exchanger (603HDTV) |
| Software | Horizon HDV with SPC, audit trail, CFR 21 Part 11–ready configuration options |
| Data Export Formats | HTML, CSV, PDF |
| Password Protection | Dual-level authentication |
| Brand | Tinius Olsen |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | F012 |
| Price Range | USD 14,000 – 70,000 |
| Load Cell Capacity | 10 N (1000 g) |
| Test Speed Range | 0.001–1000 mm/min |
| Maximum Travel | 755 mm |
| Extension Resolution | 0.001 mm |
| Controller | HMC Wireless Bluetooth Handheld Controller |
| Optional Accessories | Tension Grips, PC-Based Testing Software |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | MP1200 |
| Heating Zones | 3-zone independent PID control with Pt100 sensors |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.1 °C across furnace |
| Control Interface | 7-inch capacitive touchscreen |
| Data Interface | USB 2.0 |
| Die Release Mechanism | Drop-down die holder |
| Weight Loading | Manual or motorized weight lift option |
| Standard Die | 2.095 mm diameter × 8.000 mm length (ASTM D1238 / ISO 1133 compliant) |
| Sample Cutter | Optional manual or automatic |
| Mirror Viewport | Integrated stainless-steel mirror for real-time extrudate observation |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | TO-550 |
| Max Load Capacity | 50 kN |
| Loading Rate | 50.8 mm/min |
| Vertical Travel Range | 250–470 mm |
| Horizontal Clearance | 265 mm |
| Platen Diameter | 133 mm |
| Platen Stroke | 25 mm |
| Motor Power | 375 W |
| Dimensions (L×W×H) | 550 × 400 × 870 mm |
| Weight | 60 kg |
| Standards Compliance | ASTM D1559, BS 598-107, EN 12697-34, AASHTO T 245 |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | TO-553 |
| Compaction Hammer Mass (Light) | 4.5 kg |
| Drop Height | 457 mm |
| Compaction Hammer Mass (Heavy) | 10.2 kg |
| Sample Diameter Options | 100 mm (TO-553-1-03) or 152.4 mm (TO-553-2-03) |
| Power Supply | 220 V, 50 Hz |
| Compliance Standards | BS 598-107, EN 12697-10 & -30, AASHTO T245, ASTM D5581–1996, ASTM D6926 |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | TO-561 |
| Compliance | ASTM D 36, ASTM E 28, AASHTO T 53, EN 1427, BS 2000 |
| Voltage/Frequency | 220 V / 50 Hz |
| Sample Holder | Dual brass ring assembly with heat-resistant glass bath |
| Ball Diameter | 9.5 mm steel sphere |
| Heating System | Adjustable electric heating plate with magnetic stirrer |
| Temperature Display | Digital PID-controlled readout (±0.1 °C resolution) |
| Accessories Included | Two conical rings, two ball centering guides, two steel balls, ring holder assembly, heated stirring plate |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | TP-563 |
| Compliance | ASTM D2172, AASHTO T58/T164, EN 12697-1 |
| Adjustable Speed Range | 0–3600 rpm |
| Sample Capacity Options | 1500 kg or 3000 kg |
| Power Supply | 220 V, 50 Hz |
| Includes | 25 precision filter paper discs |
| Construction | Machined aluminum rotating bowl, cast iron housing, vertical shaft drive |
| Operation Mode | Electrical motor-coupled centrifugation |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195/880/995 |
| Measurement Method | 9 or 16 Interference Filters |
| Spectral Response | 420–710 nm |
| Bandwidth | 20 nm |
| Color Reproducibility | ±0.0004 / ±0.0002 |
| Transmittance Repeatability | ±0.5% / ±0.25% |
| Saybolt Color Accuracy | ±1 unit |
| Observer Angle | 2° and 10° CIE Standard |
| Measurement Time | ≤25 s |
| Path Length Range | 0.1–153 mm |
| Light Source | Halogen Tungsten Lamp |
| Heating Module (optional) | Up to 95 °C |
| Data Storage Capacity | 32 measurements |
| Dimensions | 17 × 52 × 20 cm |
| Weight | 7–8 kg |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Model | RC-806 |
| Dissolution Vessels | 8 |
| Temperature Range | 5.0 (ambient)–45.0 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SMC 30F |
| Pricing | Available Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TKL-B |
| Pricing | Available Upon Request |
| Hot Bath Temperature Range | 110 °C ±5 °C |
| Cold Bath Temperature Range | 2.5 °C ±0.5 °C |
| Power Supply | AC 220 V |
| Input Power | 2.5 kW |
| Hot Bath Dimensions | Ø250 mm × 325 mm (cylindrical) |
| Cold Bath Dimensions | Ø250 mm × 385 mm (cylindrical) |
| Heating Method | Nickel-Chromium Resistance Wire |
| Cooling Method | Compressor-Based Refrigeration System |
| Circulation Design | Top-inlet / bottom-return forced convection for thermal uniformity in cold bath |
| Control System | Digital PID temperature controller + time relay |
| Structural Material | FRPP (Fiberglass-Reinforced Polypropylene) tank body |
| Pump Material | Solid brass impeller and housing |
| Brand | TM Electronics |
|---|---|
| Origin | USA |
| Model | BT-1000 |
| Dimensions | 13" W × 15" D × 6.5" H |
| Power | 115 V, 50/60 Hz, 150 W |
| Pressure Range | 0.2–50 psig and 1–100 psi (oil-free, dry air) |
| Time Range | 0.1–1000 s |
| Resolution | 0.5 in H₂O |
| Test Modes | Burst, Creep, Creep-to-Failure, Leak Detection, and combined dual-mode tests (e.g., Creep/Leak, Leak/Burst) |
| Display | 20×16-character LCD with graphical capability |
| Data Storage | 1000 test results |
| Program Memory | 40 user-defined test protocols |
| Statistical Output | X̄-R control charts, histograms, mean, standard deviation, min/max, range, count |
| Interface | DB25 female (print & PLC auxiliary), DB25 male (RS-232 ASCII serial, PC/WINDOWS compatible) |
| Compliance | ISO 11607, ASTM F1140, ASTM F2054 |
| Calibration | NIST-traceable |
