| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | MBE-1 |
| Power Supply Compatibility | DC high-voltage source (0–30 kV) |
| Syringe Pump Interface | Standard Luer-lock input |
| Grounding Options | Adjustable 6 cm / 8 cm / 10 cm metallic grounding rings |
| Base Dimensions | 300 × 200 mm |
| Structural Material | Polypropylene insulating frame with grounded square metal plate |
| Needle Mounting | X–Z manual translation stage |
| Compatible Nozzle Configurations | Single-, coaxial-, and triaxial needle assemblies |
| Safety Features | Interlocked protective hood, dedicated HV terminal mounting holes, ESD-safe base architecture |
| Regulatory Alignment | Designed to support GLP-compliant process documentation and ASTM D7945-15 (electrospinning/electrospray methodology guidelines) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMS-1 |
| Price Range | USD 1,400 – 2,800 |
| Funnel Diameter | 60 mm |
| Funnel Speed Range | 0–650 rpm |
| Winding Drum Speed | 0.01–10 rpm |
| Reciprocating Stroke | ≤50 mm |
| Reciprocating Speed | 0.01–10 mm/s |
| Yarn Component Width | 100 mm |
| Max. Yarn Spool Diameter | 100 mm |
| Weight | 4 kg |
| Max. Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Operating Temperature | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PEC-1 |
| Price Range | USD 125 – 140 |
| Electrode Spacing | 0–80 mm |
| Electrode Length | 100 mm |
| Electrode Width | 10 mm |
| Overall Dimensions (L×W×H) | 120 × 120 × 90 mm |
| Electrode Material | Oxygen-Free Copper (OFHC) |
| Electrode Holder & Base Material | Polypropylene (PP) |
| Surface Finish | Sharp-edged collection faces |
| Alignment Tolerance | < 0.1° deviation over full length |
| Weight | ~1.3 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RRC-1 |
| Price | USD 1,400 (approx.) |
| Base Web Width | 100 mm |
| Speed Range | 0.01–10 rpm |
| Linear Velocity Range | 0.13–52.44 mm/s |
| Drum Diameter Compatibility | 25–100 mm |
| Roller Height Adjustment | 0–24 mm |
| Max Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Frame Material | PP Polypropylene |
| Roller & Mount | 304 Stainless Steel |
| Grounding Plate | Anodized Aluminum |
| Net Weight | 7.5 kg |
| Cable | 1 m, 5-pin aviation connector |
| Operating Temperature | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SLQ-6 |
| Sample Capacity | 6 positions |
| Sample Mass Range | 0.5–3 g |
| Measurement Range | 0–100% (w/w) |
| Accuracy | Relative deviation ≤4%, Parallel deviation ≤0.4% |
| Total Cycle Time | ≤90 min (acid digestion: 30 min, alkaline digestion: 30 min, filtration & rinsing: ~30 min) |
| Heating System | Six independent semi-spherical ceramic heating elements with individual temperature control per crucible |
| Temperature Range | Ambient to 400 °C |
| Sealing Mechanism | Dual-layer PTFE isolation gasket (top and bottom) |
| Rated Power | 2 kW |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 570 × 470 × 750 mm |
| Weight | 30 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SmartFiber-E |
| Price | USD 5,600 (FOB Shanghai) |
| Compliance | GB/T 5009.88–2008, GB/T 5413.6–2010, GB/T 9822–2008, GB/T 22494–2008, NY/T 1594–2008, AOAC 991.43, AACC 32–07, NMKL 157, ASP Method |
| Sample Throughput | 6 samples per run |
| Filtration Technology | Dual-mode SmartVacuumFilter™ with alternating positive/negative pressure |
| Crucible Type | Patented ground-glass fritted crucibles (G2, 40–100 µm pore size) |
| Filtration Speed | ≤3 min per 100 mL digestate |
| Precision | RSD <0.5% (n=6, certified reference material) |
| Software | Standalone control interface with audit trail logging |
| Accessories | G1–G5 fritted crucibles, 80–2800 mesh sieves, optional thermostatic shaker bath, standardized clamp kits |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZPT-3P |
| Material | 316L stainless steel (needle body & seat), medical-grade polypropylene (Luer adapter) |
| Dead Volume | Outer-Middle layer: 1.4 mL |
| Middle-Inner layer | 2.0 mL |
| Inner layer | 0.2 mL |
| Weight | ~300 g |
| Configurable needle gauges | e.g., 13G+16G+20G, 13G+18G+25G, 15G+20G+25G |
| Includes | 1× modular needle seat, 3× triple-needle sets, 10× 1/16″ tubing fittings, 10× small O-rings, 4× large O-rings, 4× Luer-lock adapters, 1× dual-purpose wrench, 1× metal mounting bracket |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TES-1 |
| Price Range | USD 2,800 – 7,000 |
| High-Voltage Power Supply | 0–+30 kV (adjustable), optional −30 kV |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, supports 1–60 mL syringes |
| Needle Traverse Range | 0–150 mm |
| Needle Speed | 0–1000 ±1 mm/min |
| Collector Rotation Speed | 120–3000 ±20 rpm (bidirectional) |
| Standard Collector | Balanced Rotating Drum (Φ100 × L200 mm) |
| Overall Dimensions (w/o collector) | 471 × 455 × 518 mm |
| Weight (w/o collector) | 25 kg |
| Safety Features | Emergency Stop, Grounding Protection, Overvoltage/Overcurrent/Arc-Fault Protection |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 60 W |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-2 |
| Power Supply | ±30.0 kV (0.1 kV resolution) |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, max 60 mL syringe |
| Collector Speed | 0–600 ±1 rpm, reversible |
| Nozzle Traverse Range | 40–200 mm |
| Nozzle Travel Speed | 0–1000 ±1 mm/min |
| Tip-to-Collector Gap Adjustment | up to 180 mm |
| Temperature Control | RT–50 ±1.0 °C |
| Humidity Control | 20–80 ±3 %RH |
| Chamber Dimensions (w/d/h) | 833×466×995 mm (standalone), 833×466×1800 mm (with mobile base) |
| Weight | 110 kg (standalone), 125 kg (with base) |
| Total Power Consumption | 625 W |
| Safety Compliance | Integrated emergency stop, interlocked access door, full-system grounding, overtemperature protection, ESD-safe materials (PFA tubing, anti-static polymers, carbon-brush grounding rods) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-4 |
| Voltage Output | ±30 kV (standard), optional ±60 kV |
| Collector | 304 stainless steel roller, servo-driven, max. 3000 rpm |
| Syringe Pump | Dual-channel, 2–60 mL compatibility, high-voltage rated |
| Motion Control | X (280 mm, manual), Y (180 mm auto-reciprocating, up to 3000 mm/min), Z (100 mm, manual) |
| Environmental Control | PID-controlled heating (far-infrared), condensation dehumidification, thermal evaporation humidification |
| Safety | Emergency stop, grounded conductive structure, explosion-proof tempered glass viewport, anti-static floor mat, UV germicidal lamp, observation lamp |
| Compliance | Designed for GLP-compliant electrospinning R&D environments |
| Software | Proprietary PLC-based electrospinning OS with real-time environmental logging, parameter recall, and audit-ready operation history |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WI22-0201 Octo-Configurable Kit |
| Price Range | USD 0.15 – 150.00 |
| Material | 316L Stainless Steel (Needles & Housing), Medical-Grade Polypropylene (Adapters) |
| Certifications | ISO 13485–compatible manufacturing environment |
| Pressure Test | Pre-shipped hydrostatic leak test at 0.6 MPa |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TS-100 |
| Pricing | Available Upon Request |
| Temperature Range | 5°C above ambient to 60°C (±0.5°C control accuracy) |
| Humidity Range | 70–95% RH (≤ ±2% RH uniformity) |
| Airflow Velocity | 0.3–0.5 m/s |
| Cup Dimensions | Ø60 mm ID × 22 mm depth |
| Cup Capacity | 8 units |
| Test Duration | 1–999 minutes |
| Humidification Power | 400 W |
| Heating Power | 200 W |
| Cooling Power | 270 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Chamber Interior Dimensions | 400 × 500 × 500 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSS-5 |
| Pricing | Upon Request |
| Brand | TESTech |
|---|---|
| Model | TTech-ISO817-1 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standard | ISO 817 Annex C, UL 9540A |
| Combustion Tube | Quartz glass, ID 40 mm, L 1.2 m |
| Ignition Electrodes | Tungsten wire (Ø1 mm), inter-electrode gap 6.4 mm |
| Imaging | High-speed industrial camera with flame front tracking software |
| Gas Mixing | Vacuum-assisted gas blending vessel with magnetic stirrer |
| Exhaust Treatment | Expansion chamber + acid-scrubbing wash bottle |
| Control Interface | PC-based virtual instrument platform with manual/automatic operation modes |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TTech-ISO9705 |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Compliance Basis | ISO 9705:2023, UL 9540A Annex D, GB/T 36276–2018, NFPA 855 Annex B |
| Max Fire Load | 10 MW |
| Chamber Dimensions (L×W×H) | Up to 18 m × 35 m × 15 m |
| Exhaust Flow Rate | ≥15,000 m³/h |
| Gas Analysis | H₂ + Total Hydrocarbons (THC) + FTIR Multi-Gas Quantification (CO, CO₂, HF, HCl, SO₂, NOₓ, CH₄, C₂H₄, etc.) |
| Smoke Measurement | Optical Density (Ds), Specific Optical Density (Ds/m), Mass Loss Rate (MLR), Heat Release Rate (HRR) via Oxygen Consumption Calorimetry |
| Data Acquisition | 100 Hz synchronized sampling across thermal, gas, optical, and mass loss channels |
| Brand | TTZH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT3 |
| Test Temperature Range | Down to −73 °C (with external cryogenic cooling system) |
| Axial Load | 50 N (standard, fixed) |
| Torque Measurement Range | 0–2000 N·mm (custom ranges available on request) |
| Drive System | Electronically controlled high-precision direct-drive motor |
| Torque Sensor | High-resolution digital torque transducer |
| Cooling Interface | Closed-loop cryogenic jacket compatible with liquid nitrogen or mechanical chillers |
| Control Unit | Integrated PLC-based controller with industrial touchscreen HMI |
| Data Acquisition | Real-time synchronized sampling of torque, temperature, and time |
| Software | Windows-based application supporting ASTM D1478 / IP 186/93 compliance reporting, GLP audit trails, and CSV/PDF export |
| Key | Brand: EUROTECH |
|---|---|
| Origin | Italy |
| Model | XTR60 |
| Type | Continuous Strip-to-Tube Welding & Sizing System |
| Configuration | Import (CE-compliant) |
| Distribution Status | Authorized Distributor |
| Brand | TUNE VOLT |
|---|---|
| Model | TW-2058AKL |
| Principle | Light Obscuration (Optical Blockage) |
| Particle Size Range | 0.8 µm to 500 µm |
| Detection Channels | 8 user-configurable channels |
| Resolution | <10% |
| Repeatability | RSD <2% |
| Viscosity Limit | up to 350 mm²/s (cSt) |
| Sample Volume | 0.2–1000 mL |
| Sampling Accuracy | ±1% |
| Flow Rate | 5–80 mL/min |
| Vacuum Pressure | up to 0.08 MPa |
| Positive Pressure | up to 0.8 MPa |
| Coincidence Limit | 10,000 particles/mL |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions | 400 × 340 × 660 mm |
| Weight | 23.5 kg |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | DNS |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Sample Volume | 1.5–30 mL |
| Concentration Range | 0.0001–95% v/v |
| Particle Size Range | 10 nm–1 mm |
| Detection Modes | Transmitted Light (T) & Backscattered Light (BS) |
| Scan Mode | Vertical high-frequency scanning of static sample |
| Optional Functions | T-MIX (in-situ stirring), T-LOOP (circulation coupling) |
| Output Metric | Turbiscan Stability Index (TSI) |
| Compliance Context | Designed for GLP-compliant formulation development and stability assessment per ICH Q1/Q5, USP <729>, ISO 13321 |
| Origin | Netherlands |
|---|---|
| Model | TV2000AKV |
| Temperature Range | Ambient +5 °C to 130 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±0.01 °C |
| Temperature Resolution | ±0.1 °C |
| Timing Accuracy | ±0.01 s |
| Max Timer Duration | 9999.99 s |
| Bath Capacity | 20 L |
| Heating Power | 200 / 1000 / 1500 W (triple-zone) |
| Construction Materials | AISI 304 stainless steel and PTFE |
| Safety Compliance | CE Directive |
| Dimensions (L×W×H) | 285 × 465 × 585 mm |
| Weight | 40 kg |
| Total Power Consumption | 2800 W |
| Optical Detection | Dual infrared sensors |
| Capillary Types Supported | Ubbelohde and Cannon-Fenske |
| Viscosity Range | 0.3 – 10,000 cSt |
| Calibration Storage | Up to 10 capillary constants |
| Optional Chiller Compatibility | TLC2 (enables 10 °C operation) |
| Standards Compliance | ASTM D445, ASTM D446, IP 71 |
| Brand | Tianwei Environmental (TW) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TW-CQ4 |
| Instrument Category | Pest Control Instrument |
| Dimensions | 710 × 600 × 2120 mm (including base) |
| Compliance | GB/T 24689.1–2009 |
| Brand | Tianwei Environmental (TW) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TW-CT1 |
| Instrument Category | Pest Monitoring & Forecasting System |
| Power Consumption (Standby) | ≤25 W |
| Power Supply | Solar-powered (with optional 220 V AC backup) |
| Operating Temperature | 0–70 °C |
| Relative Humidity Range | 0–85% RH (non-condensing) |
| Camera Resolution | 5 MP (500 W-pixel equivalent) |
| UV Light Source | 20 W, peak wavelength 365 nm |
| Infrared Killing Chamber Temp | 85 ± 5 °C after 15 min operation |
| Insect Mortality Rate | ≥98% |
| Specimen Integrity Rate | ≥95% |
| Image Capture Interval | Every 30 minutes |
| Communication | 4G cellular + Ethernet port |
| Integrated GPS | Yes |
| Infrared Counting Sensor Accuracy | ≥99% |
| Brand | Tianwei Environmental (TW) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TW-ZW108 |
| Price | USD 3,650 (approx.) |
| Sample Capacity | 8 × 0.2 mL tubes |
| Reaction Volume | 5–120 µL |
| Temperature Range | 4–99 °C |
| Max Heating/Cooling Rate | 7 °C/s (heat), 5 °C/s (cool) |
| Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Accuracy | ≤ ±0.1 °C |
| Excitation Source | Maintenance-free LED (400–700 nm) |
| Detection Channel | 1 channel (FAM/SYBR Green I) |
| Display | 7-inch HD capacitive touchscreen |
| Dimensions (L×W×H) | 355 × 200 × 124 mm |
| Net Weight | 2.5 kg |
| Noise Level | <45 dB |
| Thermal Lid | Auto-pressure-adjusting |
| Data Interface | USB port for import/export |
| Compliance | Approved by Ministry of Agriculture and Rural Affairs (MARA) of PRC for ASF virus detection kits |
| Key | Brand: TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-4068 |
| Quotation | Upon Request |
| Applied Standard | GB/T 9867, ISO 4649, DIN 53516 |
| Load on Specimen | 10 ± 0.2 N |
| Abrasion Distance | 20 m or 40 m |
| Roller Speed | 40 ± 1 rpm |
| Roller Diameter | 150 ± 0.2 mm |
| Specimen Diameter | 16 ± 0.2 mm |
| Overall Dimensions | 700 × 340 × 300 mm |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-4288 |
| Pricing | Upon Request |
| Worktable Width | 100 mm |
| Maximum Slice Thickness | 12 mm |
| Blade Dimensions (L×W×H) | 80 × 25 × 1 mm |
| Maximum Feed Thickness | 12 mm |
| Overall Dimensions (L×W×H) | 700 × 300 × 400 mm |
| Motor Power | 0.55 kW |
| Net Weight | 86 kg |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TY-5006UA |
| Temperature Control Range | RT to 300 °C |
| Heating Rate Options | (120 ± 10) °C/h or (50 ± 5) °C/h |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Range | 0–1.5 mm |
| Deformation Accuracy | ±0.001 mm |
| Sample Support Span | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | < 0.005 mm/100 °C |
| Load Rod & Platter Mass | 68 g |
| Heating Power | 4 kW |
| Dimensions (W × D × H) | 540 × 520 × 970 mm |
| Cooling Method | Natural cooling above 150 °C |
| Bath Medium | Methyl silicone oil (kinematic viscosity ~200 cSt) or transformer oil |
| Test Stations | 3 independent stations |
| Standard Compliance | GB/T 1633, GB/T 1634.1–3, GB/T 8802, ISO 306:2013, ISO 75-1–3:2003, ASTM D1525, ASTM D648 |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TY-6004 |
| Price Range | USD 4,200 – 7,000 |
| Measuring Range | 0–200 Mooney Units (MU) |
| Accuracy | ±0.5 MU |
| Resolution | 0.1 MU |
| Temperature Range | Ambient to 200 °C |
| Temp. Stability | ±0.3 °C |
| Heating Rate | <20 min (RT to 150 °C) |
| Rotor Speed | 2.00 ± 0.02 rpm |
| Cavity Closure Force | 11.5 kN |
| Applied Pressure | 0.4 MPa |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 800 W |
| Dimensions (W×D×H) | 660 × 570 × 1300 mm |
| Net Weight | 260 kg |
| Rotor Material | Cr6WV Tool Steel |
| Data Interface | USB |
| Software Language Support | English, Simplified Chinese, Traditional Chinese, Russian |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TYMP-II |
| Speed Options | 11 m/s or 20 m/s (selectable) |
| Motor Speed | 1400 rpm or 2800 rpm |
| Grinding Wheel Specifications | G260APRI, 150 × 40 × 32 mm (32-grit and 80-grit options available) |
| Worktable Diameter | 160 × 44 mm |
| Center Height | 214 mm |
| Traverse Stroke | 20 mm |
| Sample Dimensions | Length > 260 mm, Width ≤ 34 mm, Thickness ≤ 8 mm |
| Overall Dimensions | 500 × 400 × 314 mm |
| Weight | 80 kg |
| Dust Extraction Port | Ø50 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TYS-3672A |
| Pricing | Upon Request |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TY6004 |
| Price Range | USD 4,200 – 7,000 (FOB China) |
| Measurement Range | 0–200 Mooney Units |
| Resolution | 0.1 MU |
| Accuracy | ±0.5 MU |
| Temperature Range | Ambient to 200 °C |
| Temp. Stability | ±0.5 °C |
| Rotor Speed | 2.00 ± 0.02 rpm |
| Applied Pressure | 0.5 MPa |
| Heating Rate | <5 min (RT to 100 °C) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 800 W |
| Dimensions (W×D×H) | 660 × 570 × 1300 mm |
| Weight | 2160 kg |
| Rotor Material | Cr6WV tool steel |
| Data Interface | USB |