Optical Instruments
Filter
Showing 3541–3570 of 7843 results
| Brand | IXFiber |
|---|---|
| Origin | France |
| Type | Specialty Optical Fiber |
| Core Application | Fiber Bragg Grating (FBG) Fabrication |
| Compliance | ITU-T G.652.D, IEC 60793-2-50 |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NKD8000 |
| Price | Upon Request |
| Spectral Range (Standard) | 350–1000 nm |
| Spectral Range (UV-Enhanced) | 280–1000 nm |
| Spectral Range (NIR) | 800–1700 nm |
| Spectral Range (Broadband) | 350–1700 nm |
| Spectral Range (Extended Broadband) | 350–2200 nm |
| Spectral Resolution | 1 nm or 2 nm (selectable) |
| Measurement Time | 2–10 minutes (dependent on spectral range and configuration) |
| Analysis Time | 5 seconds–5 minutes (dependent on model complexity) |
| Incident Angle Range | 20°–70° (motorized continuous variable), or fixed angles (30°/50°/70°) |
| Spot Size | 5 mm (standard), 250 µm (optional micro-spot) |
| Sample Stage | X-Y motorized scanning stage (100 mm travel), accommodates samples from 10×10 mm to 200×250 mm |
| Max. Layers | 5-layer stack with up to two unknown parameters per layer |
| Thickness Range | 1 nm – 25 µm (wavelength-, angle-, and polarization-dependent) |
| Accuracy (semi-absorbing films) | thickness <1% (typ.), <3% (max) |
| Accuracy (metallic films) | thickness <1% (typ.), <3% (max) |
| Repeatability | transmission <0.01% (typ.), <0.1% (max) |
| Light Source | 150 W xenon arc lamp (NKD8000v) |
| Power Supply | 220 V, 50 Hz, 2 A or 110 V, 60 Hz, 3 A |
| Dimensions | 890 × 540 × 720 mm |
| Weight | 105 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J200 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Accuracy | ±0.0002 (nD) |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Light Source | LED @ 589 nm |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detection Method | Linear CCD Array |
| Display | 7-inch TFT Color Touchscreen |
| Interface | USB & RS-232 |
| Power Supply | 220 VAC / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | J300 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Refractive Index Accuracy | ±0.0002 |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.03 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detection Method | Linear CCD Array |
| Display | 7-inch TFT Color Touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | J500 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00003 |
| Brix Range | 0–100% |
| Brix Accuracy | ±0.1% |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.02 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V / 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J600 |
| Price Range | USD 2,100–7,000 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.30000–1.70000 (nD) |
| Refractive Index Accuracy | ±0.00002 |
| Brix Range | 0–100.00% |
| Brix Accuracy | ±0.01% |
| Temperature Control Range | 5–90 °C |
| Temperature Stability | ±0.01 °C |
| Light Source | LED (589 nm) |
| Prism Material | Sapphire-grade |
| Sample Cell | Stainless Steel |
| Detector | High-resolution linear CCD array |
| Display | 7-inch TFT color touchscreen |
| Interface | USB + RS-232 |
| Power Supply | 220 V AC / 50 Hz |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | P-2000 |
| Light Source | Sodium lamp (D-line, 589.3 nm), optional mercury lamp and halogen lamp |
| Temperature Control | Peltier-controlled sample holder |
| Display | Digital LCD with 0.0001° resolution |
| Measurement Range | ±90° |
| Measurement Accuracy | ±0.002° |
| Measurement Precision | 0.002° |
| Response Speed | 6°/s |
| Compliance | JP XVII, USP <781>, EP 2.2.7, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2P Microendoscope |
| Application Domain | In Vivo Intratissue Imaging, Clinical Dermatology, Tissue Engineering, Fluorescent Protein Detection |
| Compatible Platforms | DermaInspect® and MPTflex Multiphoton Workstations |
| Optical Sectioning Capability | Depth-Resolved In Situ Imaging of Human Skin and Small Animal Tissues |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2PM™ |
| Type | Imported Scientific Instrument |
| Distribution Channel | Authorized Distributor |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | 2PM™-Cryo |
| Laser Source | Ti:Sapphire femtosecond oscillator (710–920 nm, 80 MHz, 100–200 fs, <1.3 W) |
| Temperature Range | 77 K to 873 K (−196 °C to +600 °C) |
| Cooling/Heating Rate | 0.01–150 K/min |
| Spatial Resolution | <0.5 µm (lateral), <2 µm (axial) |
| Temporal Resolution | 200 ps (TCSPC, up to 256 time channels) |
| FOV | 250 µm × 250 µm (lateral), ≤2 mm depth |
| Objective | Standard 40×, NA 1.3 (optional objectives available) |
| Software | JenLab Control & JenLab Image |
| Compliance | CE-marked |
| Power Supply | 115 VAC / 60 Hz or 230 VAC / 50 Hz |
| Dimensions (excl. laser) | 700 × 520 × 800 mm³ |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | femt-O-cut |
| Laser Wavelength | 710–990 nm |
| Pulse Duration | < 100 fs |
| Repetition Rate | 80 MHz |
| Avg. Output Power | 1.5 W |
| Numerical Aperture (NA) | 1.3 |
| Lateral Resolution | < 1 µm |
| Axial Resolution | < 2 µm |
| 3D Processing Depth | Up to 100 µm |
| Minimum Feature Size | < 70 nm (FWHM) |
| Scanning Range | 350 × 350 µm (XY), 200 µm (Z) |
| Piezo Z-Stage Precision | 40 nm |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | femtOgene® |
| Laser Pulse Width | < 20 fs (typ. < 150 fs) |
| Repetition Rate | 85 MHz |
| Average Power | 200–400 mW |
| Wavelength | 800 ± 10 nm |
| Objective | 40×, NA 1.3 |
| Scan Range | 350 × 350 µm (H), 200 µm (V) |
| Stage Travel | 120 × 102 mm |
| Dispersion Compensation | Integrated high-order module |
| Operating Temp. | 15–35 °C |
| RH | 5–80% |
| Power Supply | AC 230 V, 50 Hz |
| System Footprint | Base 490 × 280 × 480 mm³ |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPTcompact |
| Pricing | Upon Request |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | MPTflex CARS |
| Detection Principle | Multiphoton Excitation + Coherent Anti-Stokes Raman Scattering (CARS) |
| Spatial Resolution | Subcellular (~0.5 µm lateral, ~1.5 µm axial) |
| Laser Wavelengths | Tunable near-infrared (700–1100 nm for excitation |
| Imaging Depth | Up to 200 µm in human skin *in vivo* |
| Real-time Chemical Contrast | Label-free molecular vibrational fingerprinting (e.g., lipids, proteins, melanin, water, collagen) |
| Regulatory Compliance | CE-marked for clinical research use |
| compliant with IEC 60825-1 | 2014 (laser safety) |
| Software Platform | MPTconsole v5.x with FDA 21 CFR Part 11–ready audit trail and GLP-compliant data archiving |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | MPTflex |
| Laser Source | Near-infrared femtosecond laser |
| Spatial Resolution | Subcellular (≤0.5 µm lateral, ≤1.5 µm axial) |
| Imaging Depth | Up to 200 µm in human skin *in vivo* |
| Detection Mode | Fluorescence & Second Harmonic Generation (SHG) |
| Clinical Compliance | CE-marked as Class IIa medical device per MDR 2017/745 |
| Software Platform | MPTconnect v5.x with FDA 21 CFR Part 11–ready audit trail and GLP/GMP-compatible data archiving |
| Brand | JenLab |
|---|---|
| Origin | Germany |
| Model | TauMap® |
| Type | FLIM/FCS/FRET Multimodal Microscopy System |
| Application Domain | Biomedical Research, Pharmaceutical Development, Live-Cell Dynamics |
| Brand | Jenoptik |
|---|---|
| Origin | USA |
| Model | ALM Series Liquid Crystal Amplitude Modulator |
| Wavelength Range | 730–1600 nm |
| Aperture Options | Standard (custom apertures available) |
| Polarization Requirement | Requires polarized input or use with external polarizers |
| Optional Accessories | Thin-film polarizers (VIS), AR-coated variants |
| Compliance | CE, RoHS |
| Mounting | Standard SM1-threaded housing compatible with Thorlabs/Optomechanics platforms |
| Operating Temperature | 15–35 °C |
| Response Time | <20 ms (typical, dependent on drive voltage slew rate) |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | C-Series (C203, C305, C308, C314, C605, C608, C614, C623, C908, C914, C923) / CS-Series (CS155, CS305, CS308, CS314, CS608, CS614, CS908, CS914) |
| Length Measurement Accuracy | (2.6 + L[mm]/200) µm (C-Series), (3.5 + L[mm]/100) µm (CS-Series) |
| Diameter Measurement Accuracy | (1.0 + D[mm]/200) µm (C-Series), (1.3 + D[mm]/100) µm (CS-Series) |
| Max Measurable Length | 250–900 mm |
| Max Measurable Diameter | 30–230 mm |
| Application Scope | Rotating shaft components requiring GD&T-compliant optical metrology |
| Brand | Jenoptik |
|---|---|
| Origin | USA |
| Model | GMP150 |
| Output Power Range | 0–150 W (1 W resolution) |
| Frequency Range | 2425–2475 MHz (±25 MHz tunable) |
| RF Ripple | <0.2% |
| Output Connector | Female N-type, 50 Ω |
| Cooling | Internal fan-cooled |
| Input Voltage | 110–230 VAC, 50/60 Hz |
| Remote Interface | RS232 |
| Protection | Reflected power limit (0–100 W adjustable) |
| Timer Range | 10 ms – 6000 s |
| Ramp & Overshoot Control | Yes |
| Warm-up Time | 0 s (instant operation) |
| Component Category | RF Source |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | Integrated Optical Amplitude Modulator |
| Substrate Material | MgO-doped LiNbO₃ |
| Operating Principle | Electro-optic (Pockels effect) in Ti-indiffused waveguide |
| Wavelength Range | 400–2000 nm (VIS to NIR/IR) |
| Modulation Bandwidth | DC to ≥10 GHz |
| Fiber Type | Polarization-maintaining single-mode fiber (PM-SMF) |
| Input/Output Coupling | FC/APC or custom connector options |
| Drive Voltage (Vπ) | Typically 3–6 V (depends on configuration) |
| Optical Power Handling | ≤500 mW (CW), higher for pulsed operation |
| Operating Temperature | 15–35 °C |
| Compliance | RoHS, CE |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Model | Integrated Optical Modulator Driver |
| Component Category | Light Source Driver |
| Compliance | CE, RoHS |
| Operating Input | TTL-compatible logic signal (≥20 ns rise time) |
| Output Rise Time | ≤1 ns |
| Output Voltage Range | Adjustable, ±5 V typical |
| Output Impedance | 50 Ω matched |
| Application Interface | SMA or LEMO connectors (configurable) |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | Integrated Optical Phase Modulator |
| Substrate Material | MgO:LiNbO₃ / LiNbO₃ |
| Operating Wavelength Range | 400–2000 nm (Visible to IR) |
| Modulation Bandwidth | DC to >1 GHz |
| Fiber Coupling | Polarization-Maintaining Single-Mode Fiber (PM-SMF) |
| RF Input | SMA or K-type connector |
| Half-Wave Voltage (Vπ) | Typically 3–6 V (depends on design & wavelength) |
| Optical Damage Threshold | >500 mW (CW), >1 MW/cm² (pulsed) |
| Operating Temperature | 15–35 °C |
| Compliance | RoHS, CE |
| Brand | Jenoptik |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PLM Series Liquid Crystal Phase Modulator |
| Component Category | Optical Modulator (Not Light Source) |
| Key Optical Function | Voltage-Controlled Birefringence-Based Phase Delay Tuning |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | SLM-S320(d)/640(d) |
| Technology | Nematic Liquid Crystal-Based Phase Modulator |
| Wavelength Range | 430–1600 nm |
| Configuration Options | Single-Layer (phase OR amplitude/polarization modulation) / Dual-Layer (simultaneous phase & amplitude modulation) |
| Active Area | Large-aperture design for high-power laser compatibility |
| Control Interfaces | LabVIEW VIs, MATLAB Toolbox, C/C++ API |
| Mounting Options | Reflective mode with optional backside mirror |
| AR Coating | Customizable broadband anti-reflection coating |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W15 |
| Measurement Principle | Contact Stylus Profilometry (ISO 21920-compliant) |
| Max Measuring Length | 17.5 mm |
| Vertical Range/Resolution (T1E stylus) | ±100 µm / 6 nm |
| Traverse Speeds | 0.15, 0.5, 1 mm/s |
| Stylus Connection | USB & Bluetooth® |
| Compliant Standards | ISO 21920-1:2021, ISO 4287:2010, ISO 13565-2/-3, ISO 12085, ISO 4288, DIN EN 10049, JIS B 0601 |
| Evaluated Parameters | Ra, Rq, Rz, Rt, Rsk, Rku, Rk-family (Rpk, Rvk, Rk), Rmr, Rdc, RΔq, RSm, AR, Wte, and >40 additional profile & functional parameters |
| System Accuracy | ±5% (per ISO 21920-3 Annex B calibration protocol) |
| Optional Accessories | LV17 Wireless Drive Box, HS300 Height Stand, MS300 Compact Measurement Station |
| Software Platform | Evovis Mobile Standard (PC-based evaluation with statistical export, GLP/GMP-ready audit trail, CSV/PDF report generation) |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W40 |
| Maximum Measurement Length | 20 mm |
| Measurement Speed | 0.2–2 mm/s |
| Connection Interface | USB-C |
| Vertical Measurement Range/Resolution | ±300 µm / 1 nm |
| Compliance | DIN EN ISO 21920, DIN EN ISO 4287:2010, DIN EN ISO 13565-2 & -3, DIN EN ISO 12085, ISO 4287:1987, DIN 4762, DIN EN ISO 4288, JIS B-0601, DIN EN 10049 / SEP 1941 |
| Accuracy | ±5% |
| Evaluation Parameters | Ra, Rq, Rsk, Rku, Rt, Rz, Rk, Rpk, Rvk, Pk, Ppk, Pvk, Wt, Wa, Wq, and >100 additional profile and amplitude parameters per ISO standards |
| Software Platform | Evovis Mobile Standard |
| Brand | Jenoptik |
|---|---|
| Origin | Germany |
| Model | W800 |
| Type | Contact Stylus-Based Surface Profilometer |
| Measurement Principle | Inductive Stylus Tracing with High-Resolution Position Feedback |
| Drive Mechanism | Motorized Bridge-Type Translation Stage |
| Probe Interface | Magnetic Quick-Change Mount with RFID-Enabled Stylus Recognition |
| Control | Integrated Handheld Control Box with Emergency Stop and Axis Resume Functionality |
| Compliance | Designed for ISO 4287, ISO 4288, ISO 25178-2, and ASME B46.1 Conformance |
| Software Platform | Jenoptik TopMap Suite (Supports GLP/GMP Audit Trail, FDA 21 CFR Part 11–Compliant User Management & Electronic Signatures) |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6800T |
| Product Type | Online Analyzer |
| Turbidity Range | 0.0–4.0 / 40.0 / 400.0 / 1000.0 NTU |
| SS Range | 0.0–10.0 / 100.0 / 1000.0 / 2000.0 mg/L |
| Resolution | 0.1 NTU, 0.1 mg/L |
| Operating Temperature | 0–60 °C |
| Accuracy | ±2% of full scale |
| Output | Dual 4–20 mA (turbidity & temperature), RS485 Modbus RTU |
| Enclosure Rating | IP65/NEMA 4X |
| Sensor Protection Rating | IP68 |
| Sensor Material | 316L stainless steel housing, custom optical glass |
| Sensor Dimensions | Ø42 mm × 210 mm L, 1" NPT male thread |
| Max Pressure | 4 bar |
| Cable Length | 10 m standard |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | CRYO ARM™ 200 II (JEM-Z200CA) |
| Acceleration Voltage | 200 kV |
| Magnification Range | ×100 to ×1,000,000 |
| Spherical Aberration Coefficient (Cs) | 1.5 mm |
| Chromatic Aberration Coefficient (Cc) | 1.8 mm |
| Specimen Temperature | ≤100 K |
| Sample Storage Capacity | Up to 12 cryo-samples |
| Energy Filter | Integrated Omega-type Energy Filter |
| Optional Software | JEOL Automated Data Acquisition System (JADAS) |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JEM-3300 |
| Price Range | USD 6.2–6.9 million (est.) |
| Acceleration Voltage | Up to 300 kV |
| Magnification Range | 2,000× – 1,000,000× |
| Electron Source | Cold Field Emission Gun (CFEG) |
| Energy Filter | Integrated Omega-Type Electron Energy Filter |
| Automation | Automated Sample Loading System, JADAS Software Suite, Phase Plate Compatibility, Köhler Illumination Optics |