Optical Measurement Instruments
Filter
Showing 1711–1740 of 3895 results
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Spectrophotometric Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm (triangular) |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Integrating Sphere Diameter | 15.2 cm (6″) |
| Sphere Coating | Spectraflect® |
| Viewing Apertures | LAV (25.4 mm illum. / 19.0 mm meas.), SAV (9.5 mm illum. / 6.3 mm meas.), MAV (4 mm meas.) |
| Specular Component | Automatic Include/Exclude |
| Transmittance Chamber | Triple-opening design |
| Measurement Interface | Dedicated tactile button with status LED |
| Sample Handling | Ergonomic sample clamp system |
| Optional Accessories | Auto-aperture lens switching, small-area and micro-area measurement kits |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed xenon lamp simulating D65 illuminant |
| Spectral Range | 400–700 nm |
| Repeatability | < 0.03 ΔE* |
| Integrating Sphere Diameter | 15.2 cm (6″) |
| Spectral Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.003% (reported as 0.01%) |
| Measurement Time | < 1 s |
| Minimum Interval Between Measurements | 3 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Compliance | CIE No.15, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Detector | 256-element Diode Array |
| Grating | High-Resolution Concave Holographic |
| Integrating Sphere Diameter | 15.2 cm (6″) |
| Sphere Coating | Spectraflect® |
| View Area Options | LAV (25.4 mm illumination / 19.0 mm measurement), SAV (9.5 mm / 6.3 mm), MAV (4 mm measurement) |
| Mirror Finish Compensation | Automatic Inclusion/Exclusion |
| Lamp Lifetime | >1,000,000 flashes |
| Measurement Time | <1 s |
| Minimum Interval Between Measurements | 3 s |
| Transmission Modes | Direct and Total Transmission |
| Transmission Chamber | Three-Sided Open Design |
| Lens Switching | Motorized LAV/SAV/MAV Selection |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | HL ColorQuest XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.003% (reported as 0.01%) |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Measurement Time | < 1 s |
| Minimum Interval Between Measurements | 3 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Integrating Sphere Diameter | 152 mm |
| Sphere Coating | Spectraflect® |
| Detector | 256-element Diode Array |
| Grating | High-Resolution Concave Holographic Grating |
| Transmittance Modes | Direct and Total |
| Transmission Chamber | Three-Sided Open |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ColorQuest XE |
| Pricing | Available Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ColorQuest XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Type | Benchtop Color Difference Meter |
| Optical Geometry | d/8° (diffuse illumination, 8° viewing) with specular component included/excluded |
| Light Source | Pulsed Xenon Flash Lamp (D65 simulated) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 10 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Measurement Modes | Reflectance, Transmittance, Opacity, Haze, Yellowness Index (YI E313), Whiteness Index (WI CIE/ASTM), APHA/Pt-Co, Gardner, Saybolt, L*a*b*, L*C*h*, ΔE*ab/ΔE00, %R, %T |
| Compliance | ASTM D2244, D6290, D313, D5386, ISO 7724, ISO 11664, CIE No. 15, USP <631>, FDA 21 CFR Part 11 ready (with optional software) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Instrument Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm (FWHM) |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Integrating Sphere Diameter | 15.2 cm (6″) |
| Sphere Coating | Spectraflect® |
| View Aperture Options | LAV (25.4 mm illum. / 19.0 mm meas.), SAV (9.5 mm illum. / 6.3 mm meas.), MAV (4 mm meas.) |
| Specular Component | Automatic Include/Exclude |
| Transmission Chamber | Triple-Opening Design |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Wavelength Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.003% (reported as 0.01%) |
| Measurement Time | < 1 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Transmission Modes | Direct and Total |
| Integrating Sphere Diameter | 15.2 cm |
| Sphere Coating | Spectraflect® |
| Standard Aperture | 25.4 mm (illuminated) / 19.0 mm (measured) |
| Optional Apertures | 9.5 mm / 6.3 mm (SAV), 4 mm (X-SAV) |
| Mirror Finish Compensation | Automatic Inclusion/Exclusion |
| Spectral Bandwidth | 10 nm (isosceles triangle) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ColorQuest XE |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Wavelength Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.003% (reported as 0.01%) |
| Measurement Time | < 1 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Transmission Modes | Direct and Total |
| Integrating Sphere Diameter | 152 mm |
| Sphere Coating | Spectraflect® |
| Standard Aperture | 25.4 mm (illumination) / 19.0 mm (measurement) |
| Optional Apertures | 9.5 mm / 6.3 mm (SAV), 4 mm (MAV) |
| Specular Component | Auto-Included/Auto-Excluded |
| Report Interval | 10 nm |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HunterLab CQXE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE* ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXE |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Spectral Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Effective Bandwidth | 10 nm (FWHM) |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Integrating Sphere Diameter | 152 mm |
| Sphere Coating | Spectraflect® |
| Standard Aperture | 25.4 mm (illuminated), 19.0 mm (measured) |
| Optional Apertures | 9.5 mm / 6.3 mm (SAV), 4 mm (MAV) |
| Specular Component | Auto-Included / Auto-Excluded |
| Aperture Switching | Motorized and Automatic |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XE |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔYI < 0.05 |
| Spectral Resolution | < 3 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–200% |
| Measurement Time | < 1 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XT |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Compliance | ASTM D1209 (APHA), ASTM D1500 (Gardner), ASTM D156 (Saybolt), ASBC, EBC, ISO 7784-2, CIE No. 15 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XT |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Light Source / Observer | C/2°, D65/10° |
| Color Spaces | CIE L*a*b*, Hunter Lab, Yxy, XYZ and ΔE*ab, ΔE00 |
| Color Scales | ASTM D1209 (APHA/PtCo/Hazen), ASTM E313 (Yellowness Index), ASTM D6166 (Gardner), ASTM D156 (Saybolt), ASTM D1500 (ASTM Color), ASBC, EBC, ADMI, Y Transmittance |
| Measurement Modes | Total and Directional Transmittance |
| Transmission Chamber Dimensions | 10.2 cm (D) × 35.6 cm (W) × 16.5 cm (H) |
| Display | Backlit LCD with capacitive touchscreen |
| Optical System | Dual-beam spectrophotometer |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Effective Bandwidth | 10 nm (triangular) |
| Light Source | Pulsed xenon lamp |
| Lamp Lifetime | >1,000,000 flashes |
| Measurement Time | <1.5 s |
| Inter-measurement Interval | ≥3 s |
| Compliance Standards | CIE No. 15.2, ASTM E1164, ASTM D5386, DIN 5033 |
| Communication Interface | RS-232C (D-sub 9-pin female) |
| Operating Environment | 10–40 °C, 10–90% RH (non-condensing) |
| Storage Environment | −21–66 °C, 10–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Power Consumption | 60 W (standby), 120 W (continuous) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorQuest XT |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Effective Bandwidth | 10 nm (triangular) |
| Repeatability | ΔE* ≤ 0.03 |
| Measurement Time | < 1.5 s |
| Minimum Inter-Reading Interval | 3 s |
| Lamp Lifetime | > 1,000,000 flashes |
| Display | Backlit Touchscreen LCD |
| Communication Interface | RS-232C (D9 female) |
| Operating Environment | 10–40 °C, 10–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Standby Power | 60 W |
| Operational Power | 120 W |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXT |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp (D65 Simulation) |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorTrend HT (CTHT) |
| Optical Geometry | 0°/45° dual-beam |
| Wavelength Range | 400–700 nm |
| Illuminant | C |
| Observer Angle | 2° |
| Measurement Spot Diameter | 20 mm |
| Measurement Distance | 50–150 mm |
| Illumination/Detection Area | 35 mm / 25 mm |
| Color Resolution | ±0.1 CIELab units |
| Height Resolution | ±0.1 mm |
| Repeatability (24 h, no recalibration) | < ±0.5 CIELab units |
| Output | Four user-configurable CIE tristimulus values + height via isolated 4–20 mA channels |
| Environmental Rating | NEMA 4 / IP65 |
| Operating Temperature | 10–50 °C |
| Power Supply | 90–250 VAC, 47–63 Hz |
| Communication | RS-232 or RS-485 |
| Compliance | Designed for GLP/GMP-aligned process monitoring environments |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorTrend HT |
| Product Type | Online Color Difference Meter |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Viewing Angle | 2° |
| Illuminant | C |
| Measurement Area | 20 mm Ø |
| Measurement Distance | 50–150 mm |
| Illumination/Detection Area | 35 mm / 25 mm |
| Color Resolution | ±0.1 CIELAB units |
| Height Resolution | ±0.1 mm |
| Repeatability (24 h, no recalibration) | < ±0.5 CIELAB units |
| Output | Four user-configurable CIE tristimulus values + height via isolated 4–20 mA channels |
| Environmental Rating | NEMA 4 / IP65 |
| Operating Temperature | 10–50 °C |
| Interface | RS-232 or RS-485 |
| Compliance | Designed for GLP/GMP environments with audit-ready data traceability |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | cPAT |
| Type | Online Color Difference Meter |
| Optical Geometry | 0°/45° Integrating Sphere |
| Application Domain | Plastic Extrusion, Compounding, and Profile Manufacturing |
| Compliance Framework | Designed for ISO 13655 (M0/M1/M2/M3), ASTM D2244, ASTM E308, CIE No. 15, and GLP/GMP-aligned process validation |
| Data Management | FTP/USB Export, Audit-Trail-Ready Calibration Logging, Real-Time Scan History (100+ scans on-screen) |
| Control Interface | PLC-Integrated Touch HMI with Closed-Loop Actuator Output (Feeder Speed, Pump Rate, Line Speed Motor, Oven Thermostat) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXE |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp (CIE Illuminant D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–200% |
| Photometric Resolution | 0.003% |
| Repeatability | ΔE* < 0.03 in CIE L*a*b* on certified white tile |
| Aperture Sizes | 25.4 mm (standard), 9.5 mm (optional) |
| Transmission Chamber Dimensions | 35.6 × 16.5 × 10.2 cm |
| Mirror Finish Compensation | Automatic Specular Component Included/Excluded |
| Compliance | ASTM E308, ISO 7724-1, ISO 11664, CIE No. 15, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXE |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop (not online — corrected per technical reality) |
| Optical Geometry | 0/45° integrating sphere (note: correction — CQXE uses d/8°, not 0/45° |
| Light Source | Pulsed Xenon Flash Lamp (CIE Illuminant D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–200% |
| Photometric Resolution | 0.003% |
| Repeatability | ΔE*ab < 0.03 (vs. NIST-traceable standard white tile) |
| Aperture Sizes | 25.4 mm (standard), 9.5 mm (optional) |
| Port | RS-232C |
| Power | 100–240 VAC |
| Compliance | ASTM E308, ISO 7724, ISO 11664, CIE No. 15, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25-NC |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cool, Energy-Efficient) |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ΔE* < 0.05 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D25/DP-9000 |
| Pricing | Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25A-DP9000 (D25A) |
| Optical Geometry | 45°/0° (dual-beam, 2-inch aperture, reducible to 1/8-inch) |
| Illuminant | C (CIE Standard Illuminant C) |
| Observer | 2° Standard Observer |
| Color Spaces | CIE XYZ, Yxy, Hunter Lab, CIE L*a*b*, CIE L*C*h°, FMC-2 |
| Color Indices | WI E313, YI E313, YI D1925, Opacity, TAPPI Brightness, Z%, Tomato Grade, ΔE, ΔEcmc, ΔC, ΔE*, ΔC* |
| Repeatability | <0.02 SD (XYZ, 20 readings) |
| Measurement Time | <1 second |
| Display | 40×8 backlit LCD with icon-driven membrane keypad |
| Data Storage | 300 sample readings + 99 product setups (battery-backed memory) |
| Interface | RS-232C bidirectional serial port (ASCII, DIF, WK1 formats) |
| Printer | Built-in 40-column thermal printer |
| Operating Environment | 14–50°C, 0–85% RH non-condensing |
| Compliance | Meets ASTM E308, ISO/CIE 11664, TAPPI T452, USP <1061>, FDA 21 CFR Part 11 (audit trail enabled via software) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HunterLab D25L-DP9000 (D25L) Colorimeter and Color Difference Meter |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D25LT |
| Pricing | Available Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | D25LT |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400–700 nm |
| Repeatability (ΔE*ab) | ≤0.03 |