Optical Measurement Instruments
Filter
Showing 1741–1770 of 3895 results
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25LT |
| Instrument Type | Benchtop Spectrophotometer |
| Optical Geometry | 45°/0° (Annular Illumination, 45° Viewing) |
| Spectral Range | 400–700 nm |
| Light Source | Full-Spectrum LED Array |
| Aperture Size | 9.5 cm (3.75 in) |
| Repeatability | ΔE*ab ≤ 0.03 |
| Display | 26.4 cm (10.4 in) Color LCD Touchscreen |
| Data Interface | USB 2.0 + Ethernet (10/100BASE-T) |
| Color Spaces | CIE XYZ, Yxy, Hunter Lab, CIELAB (L*a*b*), CIELCH, Rdab |
| Color Difference Metrics | ΔE*ab, ΔEcmc (2:1), ΔC*, ΔH*, ΔL*, Δa*, Δb*, ΔXYZ, ΔYxy, ΔRdab |
| Whiteness/Yellowness Indices | ASTM E313-96 (YI, WI), ISO 2470, DIN 6167, Ganz-Griesser Z% |
| Tolerance Mode | User-Defined Pass/Fail Thresholds per Metric |
| Statistical Functions | Mean, Std Dev, Min/Max, Range (per batch of up to 999 readings) |
| Storage Capacity | >5,000 Standard + >5,000 Sample Records |
| Operating Environment | Industrial Lab (10–40 °C, 10–85% RH non-condensing) |
| Compliance | Meets ASTM D2244, ASTM E308, ISO 11664-4, ISO 7724-1, and supports 21 CFR Part 11 audit trail configuration (via optional software license) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25LT |
| Instrument Type | Benchtop Colorimeter |
| Optical Geometry | 45°/0° (Annular Illumination, Central Viewing) |
| Measurement Area | 3.75 in (9.5 cm) diameter |
| Observer Angle | 2° |
| Illuminant | C (Simulated via Tungsten-Halogen Lamp) |
| Display | 10.4 in (26.4 cm) Full-Color LCD Touchscreen |
| Data Output | USB 2.0 & Ethernet (10/100BASE-T) |
| Internal Storage | Thousands of Standard & Sample Records |
| Print Output | Integrated Thermal Printer |
| Color Spaces | CIE XYZ, Yxy, Hunter Lab, CIELAB (L*a*b*), CIELCH (L*C*h), Rdab, X |
| Color Difference Metrics | ΔXYZ, ΔYxy, ΔLab, ΔRdab, ΔCIELAB, ΔCIELCH |
| Color Difference Indices | ΔE (CIE 1976), ΔEcmc (CIE 1995), ΔC*, ΔE*, ΔC, WIE313-96, YIE313-96, YID1925, Z% |
| Pass/Fail Evaluation | User-Defined Tolerances per Color Space |
| CMC (2 | 1) Tolerance Support |
| Environmental Rating | Industrial-Grade Enclosure (IP52 Equivalent), Designed for Factory Floor Use |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25NC |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum LED (cool, energy-efficient) |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ΔE* < 0.30 |
| Measurement Area | 129 cm² |
| Sampling Rate | 5 measurements/sec, 25 measurements/rotation |
| Data Storage | 250 user configurations + 2,000 sample records |
| Interface | USB (printer, keyboard, PC, barcode scanner) |
| Software Compatibility | EasyMatch QC |
| Power Efficiency | Low-energy LED design with extended lifetime |
| Construction | Robust industrial-grade housing |
| Cleaning | Tool-free modular disassembly |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25NC |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Long-life LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25NC |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Long-life LED |
| Spectral Range | 400–700 nm |
| Repeatability (ΔE*ab) | ≤0.03 |
| Measurement Area | 129 cm² |
| Sampling Rate | 5 measurements/sec, up to 25 measurements per rotation |
| Data Storage | 2000 sample records + 250 user configurations |
| Interface | USB for printer, keyboard, PC, barcode scanner |
| Software Compatibility | EasyMatch QC (optional) |
| Power | Low-energy LED architecture |
| Compliance | Designed for GLP/GMP environments |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | D25NC Tomato Colorimeter |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Long-life LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | Shanghai, China |
| Model | FastnessGrade Colorfastness Testing Instrument |
| Product Type | Spectrophotometric Color Measurement System |
| Instrument Form Factor | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | LED Array |
| Spectral Range | 350–700 nm |
| Repeatability (ΔE*ab) | ≤0.03 |
| Compliance | ASTM D2244, ISO 105-A02, ISO 105-A03, ISO 105-A04, ISO 105-B02, ISO 105-X12, AATCC Test Method 8, AATCC TM16, AATCC TM20, GB/T 3920, GB/T 8427, GB/T 4802.1 |
| Brand | HunterLab |
|---|---|
| Origin | Shanghai, China |
| Model | FastnessGrade |
| Product Type | Spectrophotometric Color Difference Meter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | LED Array |
| Spectral Range | 350–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | Shanghai, China |
| Model | FastnessGrade |
| Type | Benchtop Spectrophotometer |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | LED Array |
| Spectral Range | 350–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Product Category | Spectrophotometric Color Measurement Instrument |
| Compliance | ASTM D2244, ISO 105-A02, ISO 105-A03, ISO 105-B02, ISO 105-X12, AATCC Test Method 8, AATCC TM16, AATCC TM20, GB/T 3920, GB/T 8427, GB/T 4802.1 |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | FSD-300 |
| Applicable Film Width | ≤340 mm |
| Minimum Detectable Feature Size | 0.05 mm |
| Maximum Spatial Resolution | 30 µm |
| Sensor Type | Area-Scan CCD |
| Maximum Web Speed | 18 m/min |
| Light Source | 30 W LED Cold Illumination |
| Power Supply | 220 VAC, 50 Hz |
| Communication Interfaces | RS232 / RS485 / Ethernet / USB |
| Upper Unit Dimensions (L×W×H) | 230 × 131 × 108 mm |
| Lower Unit Dimensions (L×W×H) | 272 × 160 × 252 mm |
| Compliance | GB 6595–1986, ASTM D3351–93, GB/T 4611–2008, GB/T 11115–2009 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | HunterLab2 |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ISOMATCH 3G |
| Software Type | Cloud-Ready Color Formulation & Quality Control Suite |
| Compatibility | All HunterLab spectrophotometers (e.g., UltraScan VIS, MiniScan EZ, ColorFlex EZ, Agera) |
| Deployment | Windows-based client with optional SQL Server backend |
| Network Capability | Real-time LAN/WAN synchronization |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail (with optional configuration), GLP/GMP-ready logging |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISOMATCH 3G |
| Price Range | USD $1,000 – $70,000 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ISOMATCH-3G |
| Application Scope | Opaque, Translucent & Transparent Materials |
| Core Engine | Multi-Flux Spectral Prediction Algorithm |
| Connectivity | Ethernet/USB/OPC UA |
| Database Architecture | Client-Server SQL-Based |
| Compliance Support | ISO 13655, ASTM E308, CIE 15:2018, FDA 21 CFR Part 11 (Audit Trail Enabled) |
| Module Framework | Modular, License-Based Deployment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabScan XE 0/45 |
| Pricing | Available Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Reflectance |
| Light Source | Pulsed Xenon Lamp (CIE D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm |
| Bandwidth | 10 nm |
| Reflectance Range | 0–150% |
| Reflectance Resolution | 0.003% |
| Repeatability | ΔE* < 0.09 on Ceramic White Tile |
| Aperture | 44 mm (measuring), 50 mm (illumination) |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E308, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Optical Geometry | 0°/45° (15-point fiber optic ring) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Repeatability | ΔE*ab ≤ 0.09 |
| Detector | 256-element Silicon Photodiode Array |
| Illumination Area Options | 44 mm (standard), 25 mm, 13 mm, 6 mm, 3 mm (VSI optional) |
| Spectral Bandwidth | <10 nm FWHM |
| Photometric Range | 0–150% reflectance |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Interface | RS-232C DB9 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Annular Illumination with 15-Point Fiber-Optic Detection |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Photometric Range | 0–150% |
| Repeatability (ΔE*ab) | ≤0.09 |
| Illumination Area (Standard) | 44 mm Ø |
| Optional Variable Sample Illumination (VSI) | 44 / 25 / 13 / 6 / 3 mm Ø |
| Detector | 256-element Silicon Array |
| Monochromator | Diffraction Grating |
| UV Control | Automatic UV-absorbing filter (cut-on ~420 nm) |
| Lamp Lifetime | ≥1 billion flashes |
| Power Input | 100–240 VAC, 47–63 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan-XE |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | 0°/45° Annular Illumination with 15-Fiber Ring Detection |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Repeatability (ΔE*ab) | ≤ 0.09 |
| Measurement Aperture | Standard 44 mm (1.75″), Optional Variable Sample Illumination (VSI) with 5 apertures (44, 25, 13, 6, 3 mm) |
| Detector | 256-element Silicon Photodiode Array |
| Monochromator | Holographic Diffraction Grating |
| UV Control | Automatic UV-absorbing filter (cut-on ~420 nm) |
| Lamp Lifetime | ≥ 1 billion flashes |
| Communication Interface | RS-232C (DB9) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400 nm – 700 nm |
| Repeatability (ΔE*ab) | ≤ 0.09 |
| Measurement Aperture | Adjustable from 3 mm to 44 mm (VSI) |
| Sample Port Orientation | Top- or Front-Loading |
| Compliance | ASTM E308, ISO 11664-4, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LabScan XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400 nm – 700 nm |
| Repeatability (ΔE*ab) | ≤ 0.09 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LSXE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Detector | 256-element Silicon Photodiode Array |
| Spectral Separation | Diffraction Grating |
| Repeatability | ≤ 0.09 ΔE* (CIELAB, avg. of 20 readings on white tile) |
| Measurement Aperture | Standard 44 mm LAV (5 apertures available: 3, 8, 15, 25, 44 mm) |
| Measurement Time | ≤ 3 s |
| Reflectance Range | 0–150% |
| Illuminant | CIE D65 (Xenon + UV-filtered optics) |
| Compliance | ASTM E308, ISO 7724-1, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (with EasyMatch-QC v5.0+) |
| Operating Temp. | 10–40 °C |
| Storage Temp. | −20–70 °C |
| Humidity | 10–90% RH (non-condensing) |
| Interface | RS-232C, optional USB/Ethernet via PC adapter |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Desktop Colorimeter |
| Pricing | Upon Request |
| Product Type | Colorimeter |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° |
| Light Source | Pulsed Xenon Lamp (D65-simulated, UV-enhanced) |
| Spectral Range | 400–700 nm |
| Reporting Interval | 10 nm |
| Detector | 256-element silicon photodiode array with diffraction grating |
| Aperture Options | 3 mm, 8 mm, 15 mm, 25 mm, and 44 mm (LAV) |
| Reflectance Range | 0–150% |
| Repeatability | <0.05 ΔE*ab (white tile, 10 readings) |
| Measurement Time | ≤3 s |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E308, DIN 5033, JIS Z 8722 |
| Software Interface | RS232C, compatible with HunterLab EasyMatch-QC v5.x and industry-specific color formulation platforms |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabScan XE |
| Product Type | Spectrophotometric Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.09 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Product Type | Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Detector | 256-element silicon photodiode array with diffraction grating |
| Aperture Options | 44 mm, 25 mm, 13 mm, 6 mm, 3 mm (motorized variable aperture) |
| Repeatability (ΔE*ab) | ≤ 0.09 |
| Measurement Time | ≤ 3 s |
| Reflectance Range | 0–150% |
| UV Filtering | Optional 420 nm cut-off filter |
| Compliance | CIE No. 15, ASTM E308, ASTM D1925 (Yellowness Index), ASTM E2698 (Plastics), ISO 7724, ISO 11664, USP <631>, FDA 21 CFR Part 11 (with EasyMatch-QC software enabled) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400 nm – 700 nm |
| Wavelength Interval | 10 nm |
| Repeatability | ΔE*ab ≤ 0.09 |
| Aperture Size | 44 mm (LAV) |
| Measurement Time | ≤ 3 s |
| Photometric Range | 0–150% Reflectance |
| Detector | 256-element Silicon Photodiode Array with Diffraction Grating |
| Illuminant Simulation | D65 (Xenon + Filter) |
| Operating Voltage | 100–240 VAC, 47–63 Hz |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Interface | RS-232C |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Product Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | 0°/45° (annular, non-contact) |
| Light Source | Pulsed Xenon Lamp with D65 Illuminant Simulation |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| Detector | 256-element Silicon Photodiode Array with Diffraction Grating |
| Aperture Options | 3 mm, 8 mm, 15 mm, 25 mm, and 44 mm (LAV) |
| Repeatability | ΔE* < 0.09 |
| Measurement Time | ≤ 3 s |
| Reflectance Range | 0–150% |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E308, DIN 5033, JIS Z 8722 |
| Software Compatibility | HunterLab EasyMatch QC (21 CFR Part 11 compliant audit trail option available) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabScan XE for Steel Industry |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp with D65 Illuminant Simulation |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ΔE* ≤ 0.15 CIELAB (average) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | 0/45° (annular illumination, 45° viewing) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.09 |
| Aperture Size | 44 mm |
| Compliant Standards | ASTM E313-96, USDA-recognized for tomato product evaluation |
| Built-in Tomato-Specific Indices | Tomato A/B Ratio, Lycopene Estimate (Hunter LAB), Tomato Juice Score, Tomato Catsup Score, Tomato Paste Score, Tomato Sauce Score, 457-nm Brightness, C/2° and D65/10° Yellowness Index |