Particle/Powder Analysis Instruments
Filter
Showing 631–660 of 969 results
| Brand | PULUODY |
|---|---|
| Model | PLD-601Q |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±5% typical (per USP <788>, ISO 21501-4, ChP 2020) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GMP/GLP audit trail, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9–2013, GB 8368, ISO 21501-4, ISO 11171, NAS 1638 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601S |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Edition 0903, GB/T 11446.9–2013, JJG 1061 |
| Software Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Sample Compatibility | Aqueous & non-aqueous sterile solutions, lyophilized powders (after reconstitution), ophthalmic preparations, vaccines, WFI, medical packaging components, infusion devices, terminal filters |
| Operating Temperature | 0–80 °C (fluid), –15–50 °C (ambient) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Counting Accuracy | ±5% typical (per ChP/USP verification protocols) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-aligned calibration), <10% (ISO 21501-4 aligned) |
| Regulatory Documentation Support | GLP/GMP-compliant test reports, validation templates (IQ/OQ/PQ), metrological traceability via NWMS (National Northwest Metrology Testing Center) and DFKW No. 116 Calibration Station |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601W |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm (customizable down to 0.1 µm with certified calibration) |
| Channel Resolution | 1000 adjustable size channels |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Compliance | USP <788>, <789>, <797> |
| Software | V8.9 Integrated Analysis Suite (PC & embedded touchscreen) |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Range | 0–50 °C |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±5% typical (per ChP) |
| Overlap Error | ≤5% |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO-calibrated) |
| Calibration Standards | NIST-traceable latex spheres, JJG 1061–2010, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601X |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Channel Resolution | 1000 channels |
| Measurable Size Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±5% typical |
| Counting Precision (Coincidence Limit) | ≤5% at 1000 particles/mL |
| Resolution | >95% (calibrated per ChP 2015/2020), <10% (per USP <788> & ISO 21501) |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signature, 5-Level User Permission Management |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Regulatory Alignment | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601XY |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm (optional extended range: 0.03–3000 µm) |
| Channel Count | 1000 customizable size channels (down to 0.01 µm resolution) |
| Flow Control | Dual-precision metering piston pump + ultra-precise electromagnetic flow control system |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601Y |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Sample Introduction | Disposable Needle Sampling Probe |
| Channel Resolution | 1000 Adjustable Channels (Down to 0.01 µm) |
| Detection Range | 1–450 µm (Extended Options: 0.03–3000 µm) |
| Accuracy | ±3% (Typical), Calibration Traceable to JJG1061, ISO 21501, or NIST-Traceable Latex Standards |
| Counting Repeatability | ≤3% Coincidence Error at 1000 particles/mL |
| Resolution | >95% (Ph. Ch. 2015/2020 compliant), <10% (USP/ISO 21501 compliant) |
| Flow Rate | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Operating Ambient | −15–50 °C |
| Software | V8.9 Integrated PC & Touchscreen Analysis Suite |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signature, Role-Based 5-Tier Permissions), GLP/GMP-Ready Data Integrity Architecture |
| Standards Supported | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601Y |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (customizable to 0.03–3000 µm) |
| Channel Count | 1000 adjustable size channels |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-2 compliant) |
| Software | V8.9 Regulatory-Compliant Analysis Suite |
| Compliance | FDA 21 CFR Part 11, GMP/GLP Audit Trail, Electronic Signature, Five-Tier User Access Control |
| Standards Supported | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601Z |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Sample Introduction | Disposable Needle Sampling Probe |
| Channel Resolution | 1000 Adjustable Channels (Down to 0.01 µm) |
| Detection Range | 1–450 µm (Extended options: 0.03–3000 µm) |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Repeatability | ≤3% coincidence error at 1000 particles/mL |
| Flow Rate | 5–150 mL/min (sampling), 5–500 mL/min (rinse) |
| Temperature Range | Fluid 0–80 °C |
| Compliance | Meets ChP 0903, USP <788>/<789>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Regulatory-Grade Analysis Suite (FDA 21 CFR Part 11 Compliant) |
| Data Integrity | Audit Trail, Electronic Signature, Role-Based 5-Tier User Permissions, Auto Backup/Restore, Power-Fail Recovery |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-820X |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channel Resolution | 1000 adjustable channels (16 user-selectable) |
| Viscosity Handling | Up to 1850 mm²/s (cSt) without dilution or heating |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Sampling Flow Rate | 5–60 mL/min |
| Accuracy | ±1% volumetric delivery |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Standards Compliance | ISO 4406, ISO 11500, ISO 11171, NAS 1638, GJB 420A/B, DL/T 432, MIL-STD-1246, ASTM D6786 (referenced), GB/T 18854-2002 |
| Calibration Reference | NIST-traceable GBW standard reference materials |
| Operating Temperature | Ambient to 65°C (sample), 0–50°C (ambient) |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-820X-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channel Resolution | 1000 adjustable channels (up to 16 active per test) |
| Viscosity Handling | ≤1850 mm²/s (cSt) |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min, accuracy ±1%) |
| Test Duration | Configurable, default 20 s |
| Repeatability | ≤5% coincidence error at 10,000 particles/mL |
| Operating Temp. | Ambient to 65 °C |
| Ambient Temp. | 0–50 °C |
| Power | 220 V, 50 Hz, <80 W |
| Compliance Standards | ISO 11500, ISO 4406, ISO 11171, NAS 1638, GJB 420A/B, GJB 380, MIL-STD-1246, DL/T 432, DL/T 1096, ROCT 17216, GB/T 18854–2002 |
| Calibration Reference | NIST-traceable GBW standard particles |
| Data Storage | 3000 tests onboard (industrial PC), unlimited via external PC |
| Interface | RS232, optional Wi-Fi/Bluetooth (customizable) |
| Display | 8.2″ color TFT-LCD touch interface running PULUODY ColorOS v8.2 |
| Software | P6.4 Particle Analysis Suite (embedded & PC versions) |
| Optional Modules | Water saturation detection, moisture content analysis |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801 |
| Instrument Type | Optical Particle Counter (Light Obscuration & Light Scattering Dual-Mode) |
| Detection Range | 0.5–100 µm |
| Channel Resolution | Up to 1000 user-configurable size channels (16 standard) |
| Sampling Flow Rate | 5–150 mL/min |
| Counting Accuracy | ±3% |
| Sizing Accuracy | ≥90% |
| Sample Volume Precision | ±1% |
| Measurement Time | 5 s to user-defined |
| Calibration Standard | NIST-traceable latex spheres |
| Operating System | Windows-based control software |
| Communication Interface | Standard TCP/IP |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801ZX |
| Instrument Type | Optical Particle Counter (Dual-Mode: Light Scattering + Light Obscuration) |
| Detection Range | 0.5–100.0 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Platform (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PLD-MPCS Series |
| Instrument Type | Optical Microscopy-Based Particle Counter |
| Key Imaging Resolution | 0.1 µm |
| Measurement Range | 1–500 µm |
| Magnification | 40×–1000× |
| CCD Sensor | ≥5 MP (standard configuration) |
| Repeatability Error | < 5% (excluding sample preparation variability) |
| Particle Segmentation Speed | < 1 s per field |
| Segmentation Success Rate | > 93% |
| Software Platform | Windows OS-compatible image analysis suite with RS232/USB interface |
| Compliance Standards | ISO 16232, ISO 4406, VDA 19, GME 7061, GMW 16037-2017, JB/T 7858, GB/T 20110, DL 432 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Microscopy-Based Particle Counting System |
| Measurement Range | 1 µm – 500 µm |
| Repeatability | < 5% (excluding sample preparation variability) |
| Analysis Time | 60 seconds |
| Magnification | 40× – 1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm division) |
| Software Environment | Windows OS (XP through 11) |
| Interface | RS-232 or USB |
| Particle Recognition Accuracy | >95% (per ChP 2020), <10% misclassification (per USP <788> & ISO 21501-1) |
| Overlap Tolerance | ≤5% at 10,000 particles/mL |
| Image Stitching | Fully automated, seam-free membrane scanning |
| Segmentation Speed | <1 second per field |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Instrument Type | Optical Microscopy-Based Particle Counter |
| Measurement Principle | ISO 21501-4 / USP <788> Microscopic Particle Counting Method |
| Test Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation variability) |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm graduation) |
| Particle Segmentation Speed | <1 s per field |
| Segmentation Success Rate | >93% |
| Detection Resolution | >95% (per ChP 2020), <10% false-negative rate (per USP <788>, ISO 21501) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Software Platform | Windows 2000/XP-compatible proprietary image analysis suite |
| Interface | RS-232 or USB 2.0 |
| Compliance | USP <788>, <789>, EP 6.0–8.0, JP 14–16, BP 2009–2013, IP 2010, IntPh V, ChP 2015 & 2020, GB/T 11446.9–2013, GB 8368, ISO 21501-4, ISO 21510, ISO 11171 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-MPCS2.0-1 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Digital Image-Based Microscopy with Polarized Light |
| Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Maximum Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm (excluding sample preparation variability) |
| Repeatability Error | < 5% (excluding sample preparation variability) |
| Camera | ≥5 MP CCD sensor |
| Calibration Scale | 0.1 µm per pixel |
| Particle Segmentation Speed | < 1 s per image |
| Segmentation Success Rate | > 93% |
| Software Platform | Windows 2000/XP |
| Interface | RS-232 or USB |
| Compliance | ISO 16232, ISO 4406, VDA 19, GME 7061, GMW 16037, JB/T 7858, GB/T 3821, DL 432 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMF-2801.1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Standalone Touch Interface) |
| Output | 4–20 mA Analog Signal, Optional Alarm Relay, iPad-Compatible Data Acquisition |
| Compliance Mode | Separated Civil/Military Standard Configuration |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 Contamination Code |
| Brand | PULUODY |
|---|---|
| Model | PMT |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Seventh-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Standards | ISO 4406, NAS 1638, ISO 11171, ISO 11500, GB/T 14039, DL/T 432, GJB 420B |
| Particle Size Range | 2–100 µm or 4–70 µm(c) |
| Calibration Standards | ISO 4402 (ACFTD), ISO 11171 (MTD), GB/T 18854 |
| Accuracy | <3% typical |
| Channel Count | 1000 configurable size bins |
| Sample Flow Rate | 10–60 mL/min |
| Rinse Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range (Fluid) | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Interface | RS232 / RS485-to-USB / native USB |
| Analog Output | 4–20 mA with programmable contamination alarm |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen |
| Compliance | Meets requirements for GLP/GMP traceability, FDA 21 CFR Part 11-ready software architecture (audit trail, electronic signature support in P6.4 software) |
| Brand | PULUODY |
|---|---|
| Model | PMT |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Seventh-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Particle Size Range | 2–100 µm (or 4–70 µm(c)) |
| Channel Count | 1000 adjustable size channels (user-definable 16 channels) |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Max Online Pressure | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Fluid 0–80 °C |
| Interface | RS232 / RS485 / USB |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Sampling System | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Accuracy | <±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with customizable over-limit alarm |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Separation Architecture |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser light scattering with narrow-beam geometry |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog interface with customizable alarm logic |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Separation Platform |
| Compliance Architecture | Dual-mode (civil/military standard support) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | <±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, JJG 1061, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen) |
| Data Output | Particle count per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination grading |
| Analog Output | 4–20 mA with configurable alarm threshold |
| Power Input | 100–265 VAC, 50–60 Hz |
| Interface | Color TFT LCD touchscreen + optional wireless keyboard/mouse |
| Data Acquisition | iPad-compatible real-time streaming |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable Latex Spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition, PC-based V8.3 Analysis & Calibration Software Suite |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Context | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface, iPad-compatible wireless acquisition |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.065–0.2 µm and 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with configurable particle-count alarm |
| Data Acquisition | iPad-integrated wireless acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Display | Color LCD touch interface with optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Mode | Separated civilian/military standard configuration |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail (software-configurable), GLP/GMP-compliant reporting templates |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Options | 4–20 mA analog signal,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & Touchscreen GUI) |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready configuration (optional), ISO/IEC 17025 traceable calibration workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measurement Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 4–70 µm(c), or user-defined 1–100 µm) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal + digital alarm trigger |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded touchscreen version) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance | Supports GLP audit trails, configurable report generation per ISO 4406, NAS 1638, and SAE AS4059D |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sample Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Compliance | Supports 21 CFR Part 11 audit trail (via optional software module), GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Sample Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Counting Resolution | 0.1 µm (c) minimum detectable threshold |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Analog Output | 4–20 mA |
| Data Interface | IPAD-compatible wireless acquisition system |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Origin | Shaanxi, China |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm |
| Customizable Range | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368, JJG 1061, ISO 21501-4 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |