| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2S |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm threshold |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Standalone Modes) |
| Compliance Support | GLP/GMP audit trails, FDA 21 CFR Part 11-ready configuration (user authentication, electronic signatures, change logs) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2s |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–1.0 µm (standard) |
| Sample Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO Class 1–5 cleanroom liquid monitoring environments |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Connectivity | USB, Ethernet, optional iPad-based remote acquisition |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2SH |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser light scattering with narrow-beam geometry |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference materials |
| Detection Range | 0.1–0.5 µm, 0.2–2.0 µm, 0.5–20.0 µm (user-definable sub-ranges: 1–100 µm or 4–70 µm(c) |
| minimum detectable size | 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Flow Control | Precision metering piston pump + electromagnetic flow regulation |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + tablet-compatible) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PMT-2SY |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination code |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-4 compliant |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2ZX |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with configurable alarm thresholds |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | PRF-III |
| Instrument Type | Optical Particle Counter |
| Magnetic Head Field Strength | 100–1000 Gs (≥600 Gs at peak working point) |
| Deposition Speed | 70 rpm (spectrogram formation), 150 rpm (cleaning/fixation), 200 rpm (drying) |
| Reproducibility | <8% mean error across 8 microscope fields (qualitative), <12% across 4 fields (quantitative) |
| Linear calibration range (optical density vs. debris mass) | 0–55% |
| Oil sample contamination range | 0–3000 ppm |
| Substrate | 55 × 55 × 0.17 mm optical glass slide |
| Control | Four-button tactile interface with real-time RPM and timer display |
| Dimensions | 420 × 310 × 280 mm |
| Power | 220 V, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PRF-III-01 |
| Instrument Type | Optical Particle Counter for Wear Debris Analysis |
| Core Function | Magnetic Separation & Morphological Characterization of Ferrous Wear Particles in Lubricants |
| Brand | PULUODY |
|---|---|
| Origin | Xi’an, Shaanxi, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Category | Domestic |
| Model | PS8011 |
| Instrument Type | Optical Particle Counter Sampling Vial |
| Capacity | 220 mL / 250 mL |
| Material | High-Silica Borosilicate Glass |
| Max. Temperature Resistance | 150 °C |
| Max. Pressure Resistance | 0.1 MPa |
| Cleanliness Grade | NAS 00–4 (per 100 mL) |
| AOQL (Average Outgoing Quality Limit) | 0.5% |
| RCL (Residual Contamination Level) | ≤15 particles ≥4 µm per 100 mL |
| Validated Standards | ISO 3722, GB/T 17484, NAS 1638, ISO 4406, SAE AS749D, ISO 16232, GJB 420A/B, GB/T 14039, DL/T 427, DL/T 1096 |
| Cleaning Process | Ultrasonic cleaning (high-precision), Class 100,000 cleanroom air shower, hot-air drying & hermetic sealing, UV sterilization, cleanliness verification |
| Seal | External-thread cap with O-ring drip-proof gasket |
| Compatibility | Fully compatible with HIAC ROYCO 8000A/8011/8012, PALL HPCA-Kit-O/HPCA-2/PIM400/PCM400/PFC400, SBSS, S40, and all ISO/NAS-compliant optical particle counters |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSC |
| Pricing | Available Upon Request |
| Detection Limit | 1 µg/mL / 0.01 FU / 0.01% |
| Measurement Speed | ≥50 Hz (up to 1000 data points/sec) |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Excitation Source | Dynamic X-ray Fluorescence (XRF) with 150 µW output |
| Measurement Spot Size | 0–1.5 mm or 0–5 mm |
| Working Distance | 3.5–4.5 mm or 20 mm |
| Oil Film Thickness Range | 0–9950 mg/mm² |
| Fluorescence Units (FU) Range | 0–1950 FU |
| Calibration Traceability | NIST- or GBW-certified reference materials |
| Compliance | OIML R 111-1 traceable via NIM (China) and NIST (USA) |
| Data Interface | RS-485 or RS-232 |
| Power Supply | Rechargeable battery or 220 V AC adapter |
| Brand | PULUODY |
|---|---|
| Model | PSC-3A |
| Origin | Shaanxi, China |
| Detection Principle | Fluorescence Energy Spectroscopy (FES) |
| Measurement Range | 0.01 FU (RFU) to full-scale fluorescence response |
| Detection Limit | 1 µg/mL (for representative hydrocarbon standards) |
| Response Time | 0.1–30 s per measurement |
| Sampling Rate | Up to 1000 data points/second |
| Output Units | Standardized Fluorescence Units (FU), % relative to calibration reference, or user-defined scale |
| Sample Compatibility | Flat or moderately curved solid surfaces (metals, composites, ceramics, plastics) contaminated with petroleum-based oils, synthetic lubricants, greases, hydraulic fluids, and other fluorescent organic residues |
| Compliance | Designed for alignment with ISO 8502-9 (Surface cleanliness by fluorescence), ASTM D7474 (Standard Test Method for Determination of Oil and Grease in Wastewater by Infrared Spectrophotometry — adapted for surface residue quantification via fluorescence correlation), and GLP/GMP-relevant data integrity practices |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSC-3A |
| Instrument Type | Optical Fluorescence-Based Particle & Contaminant Analyzer |
| Detection Principle | Fluorescence Energy Spectroscopy (FES) |
| Measurement Range | 0–100% relative oil contamination |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Detection Speed | ≥50 measurements/sec |
| Excitation Source | Dynamic X-ray Fluorescence (XRF), 150 µW |
| Measurement Spot Size | Adjustable (1–5 points), spot diameter 0–1.5 mm or 0–5 mm |
| Working Distance | 3.5–4.5 mm or 20 mm |
| Calibration Traceability | NIST- and GBW-certified reference standards |
| Compliance | OIML R 127 (surface contamination metrology), ISO 8502-3 (surface cleanliness), ASTM D7619 (fluorescent residue quantification) |
| Optional Module | Integrated particle counting (size ranges: A: 0.1–10 µm, B: 1–20 µm, C: 5–50 µm) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PSC-3A-1 |
| Price | USD 31,800 (approx.) |
| Measurable Contaminants | Oils, greases, coolants, cutting fluids, waxes (C5–Cn hydrocarbons) |
| Cleanliness Scale | 0–100% relative contamination level |
| Resolution | 0.01% |
| Accuracy | ±0.5% |
| Fluorescence Units (FU) | 0–1950 FU |
| FU Resolution | 0.01 FU |
| FU Accuracy | ±0.5% |
| Oil Film Thickness | 0–9950 mg/mm² |
| Thickness Resolution | 0.1 mg/mm² |
| Thickness Accuracy | ±0.5% |
| Measurement Spot Diameter | 0–1.5 mm or 0–5 mm (selectable) |
| Working Distance | 3.5–4.5 mm or 20 mm (dual-mode optical path) |
| Excitation Source | Dynamic X-ray Fluorescence (XRF) |
| Excitation Power | 150 µW |
| Detection Frequency | ≥50 Hz |
| Calibration Reference | Surface-specific calibration supported |
| Metrological Traceability | Certified reference materials traceable to GBW (China) and NIST (USA) |
| Calibration Modes | Auto-calibration, manual calibration, multi-point calibration |
| Measurement Points | 1–5 points per sample (user-configurable) |
| Communication Interface | RS-485 or RS-232 |
| Control Platform | PC-based or industrial computer |
| Power Supply | Rechargeable Li-ion battery or AC adapter (220 V AC) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PSC-3B |
| Price | USD 39,800 (FOB) |
| Measurement Principle | Fluorescence Energy Spectroscopy (FES) |
| Detection Target | Hydrocarbon-based contaminants (mineral oils, synthetic lubricants, cutting fluids, greases, waxes |
| Quantification Units | % relative cleanliness, FU (Fluorescence Units), mg/mm² oil film thickness |
| Detection Limit | 1 µg/mL equivalent surface concentration |
| Resolution | 0.01% / 0.01 FU / 0.1 mg/mm² |
| Accuracy | ±0.5% of reading |
| Measurement Time | 0.1–30 s per point |
| Spot Size Options | Ø1.5 mm or Ø5 mm |
| Working Distance | 3.5–4.5 mm (standard) / 20 mm (extended) |
| Excitation Source | Dynamic X-ray fluorescence (XRF) module |
| Excitation Power | 150 µW |
| Sampling Rate | ≥50 Hz |
| Calibration Traceability | NIST-traceable or GBW-certified reference standards |
| Calibration Modes | Auto-calibration, manual zero/baseline, multi-point curve calibration |
| Data Interface | RS-485 / RS-232 |
| Control Platform | PC-based or industrial computer |
| Power Supply | Rechargeable Li-ion battery or AC adapter (100–240 VAC) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSC-3C |
| Price | USD 34,500 (FOB) |
| Sensor | 7th-Generation Dual-Laser Narrow-Beam Particle Detector (Lifetime > 200,000 measurements) |
| Detectable Particle Sizes | Configurable Channels — A: 0.3/2.5/10 µm |
| B | 0.3/(0.5/1.0/2.5/5.0)/10 µm |
| C | 0.3/0.5/1.0/2.5/5.0/10 µm |
| D | 0.5/1.0/1.5/2.0/2.5/3.0 µm |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Airflow Rate | 2.83 L/min (0.1 cfm), adjustable |
| Sampling Duration | 30 s per measurement |
| Measurement Modes | Timed or Continuous Cycling |
| Alarm Types | User-Defined Particle Count & Mass Thresholds |
| Data Storage | 100,001 records (real-time or scheduled) |
| Communication | RS232, USB, RS485 |
| Power | Rechargeable 4100 mAh Li-polymer battery or 220 V AC adapter |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Measurement Points | 1–5 per surface area |
| Calibration Traceability | NIM (China) and NIST (USA) certified reference materials per GBW and ISO/IEC 17025 protocols |
| Compliance | GB/T 16292–1996, ISO 14644-1:2015 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | PSD-250 |
| Instrument Type | Optical Particle Counter Accessory |
| Material | LC Super-Hard Aluminum Alloy |
| Surface Treatment | Zinc Plating for Corrosion Resistance |
| Capacity | 250 mL |
| Operating Vacuum Pressure | 2 kPa |
| Compliance | GB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007 |
| Sampling Vessel Cleanliness Grade | NAS 1638 Class 0 |
| Cleanliness Performance | ≤15 particles ≥4 µm per 100 mL (RCL ≤15/100mL) |
| Tubing Specification | NAS 1638 Class 0 fluoropolymer tubing |
| Included Components | 1 × negative-pressure sampling gun, 1 × 250 mL NAS Class 0 clean bottle, 1 × NAS Class 0 tubing (length adjustable) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanliness Classes | ISO Class 4 (10 particles/ft³ ≥0.1 µm), ISO Class 5 (100 particles/ft³ ≥0.5 µm) |
| Airflow Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Germicidal Lamp |
| Optional Accessories | Pneumatic Rotary Stage (bidirectional), High-Purity Nitrogen Inlet with Particle Filter, Adjustable Gooseneck Nozzle |
| Brand | PULUODY |
|---|---|
| Model | PSD-PF10A-0.5 |
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter Integrated Clean Bench |
| Cleanliness Class | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Airflow Velocity Range | 0.25–0.6 m/s (Adjustable via Control Panel) |
| Vibration Amplitude | ≤3 µm (Operational) |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for Surface Bioburden Reduction |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PSD-PF10A-0.5 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Cleanroom Classification | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Repeatability | ±1% |
| Measurement Time | 15 s |
| Airflow Velocity Range | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for microbial reduction to sterile conditions |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm optional) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PYX-2A |
| Instrument Type | Optical Light-Blockage Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 1–500 µm |
| Adjustable Channel Count | 16 (standard), up to 1096 user-defined channels |
| Sample Volume | 0.2 mL to custom-defined volume |
| Size Accuracy | ≥95% |
| Counting Accuracy | ±5% |
| Sampling Precision | ±0.5% |
| Flow Rate | 5–100 mL/min |
| Dimensions | 220 × 320 × 335 mm |
| Weight | 9.8 kg |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PYX-2A-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 1–500 µm |
| Adjustable Channel Count | 16 (standard), up to 1096 user-defined channels |
| Sample Volume | 0.2 mL to user-defined |
| Size Accuracy | ≥95% |
| Counting Accuracy | ±5% |
| Sampling Precision | ±0.5% |
| Flow Rate | 5–100 mL/min |
| Dimensions | 220 × 320 × 335 mm |
| Weight | 9.8 kg |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | PULUODY |
|---|---|
| Model | P-III (or P3) |
| Instrument Type | Optical Surface Particle Counter |
| Detection Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across six channel sets (A–F), ranging from 0.1 µm to 25.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rate Options | 2.83 L/min or 28.3 L/min |
| Sampling Duration | Programmable (3–60 s) |
| Operating Temperature | –40 °C to +120 °C |
| Environmental Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 14644-1, ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Data Integrity Features | Role-based access control, audit trail, electronic records (21 CFR Part 11 ready) |
| Interface Options | RS232, RS485, LAN, USB |
| Storage | Configurable real-time/timed logging with unlimited capacity |
| Alarm Outputs | Customizable particle count/mass thresholds |
| Probe Options | Straight probe (UK4400302), 90° angled probe (UK4400304), multifunctional surface probe (UK44003012) |
| Brand | PULUODY |
|---|---|
| Model | P-III |
| Type | Optical Surface Particle Counter |
| Measurement Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across 6 preset modes (A–F), down to 0.1 µm |
| Accuracy | ±30% for size distribution & concentration |
| Flow Rate | 2.83 L/min or 28.3 L/min (selectable) |
| Sampling Duration | 3–60 s (programmable) |
| Compliance | ISO 14644-1, ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Data Integrity | Audit trail, role-based access control, electronic records (21 CFR Part 11–ready architecture) |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interface Options | RS232, RS485, LAN, USB |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Outputs | Customizable count/mass thresholds |
| Probe Flexibility | Multiple interchangeable sampling probes for flat, curved, recessed, or confined surfaces |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | P-III ST |
| Instrument Type | Optical Surface Particle Counter |
| Measurement Principle | Light Scattering (Laser-Based) |
| Standard Compliance | ISO 14644-9, ISO 21501-4, JIS B 9921 |
| Flow Rate Options | 2.83 L/min & 28.3 L/min |
| Detectable Particle Sizes | 0.1 µm to 25.0 µm (configurable channels A–F) |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Operating Temperature | −40 °C to +120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Interfaces | RS232, RS485, LAN, USB |
| Data Storage | Configurable real-time/timed storage, unlimited capacity |
| Audit Trail & User Access Control | Yes |
| Regulatory Features | Electronic records, role-based permissions, FDA 21 CFR Part 11–compatible logging (when enabled) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | P-III+ |
| Price | USD 105,000 (FOB) |
| Particle Size Channels | A: 0.3, 2.5, 10 µm |
| B | 0.3, (0.5/1.0/2.5/5.0), 10 µm |
| C | 0.3, 0.5, 1.0, 2.5, 5.0, 10 µm |
| D | 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 µm |
| E | 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm |
| F | 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rates | 2.83 L/min and 28.3 L/min (selectable) |
| Sampling Duration | 3–60 s (programmable) |
| Operating Temperature | −40 to 120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, ISO 14644-9 |
| Data Interfaces | RS232, RS485, LAN, USB |
| Audit Trail & User Access Control | Yes |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Outputs | Configurable count/mass thresholds |
| Storage | Unlimited real-time/timed logging |
| Optional Accessories | Straight probe (UK4400302), 90° probe (UK4400304), Multi-functional probe (UK4400301) |
| Brand | PULUODY |
|---|---|
| Model | UP-200 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Light Scattering (Dual-Laser Narrow-Beam) |
| Particle Size Range | 0.1–100 µm (optional 0.03–3000 µm) |
| Accuracy | ≤±3% (typical) |
| Coincidence Error | ≤±3% at ≥1000 particles/mL |
| Sampling Flow Rate | 5–100 mL/min |
| Sampling Precision | ≤±1% |
| Pressure Range | 0–0.5 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Fluid Temperature Range | 0–80 °C |
| Calibration Standard | NIST-traceable polystyrene latex spheres |
| Output Interfaces | USB, LAN, RS232/RS485, 4–20 mA analog output |
| Compliance | ISO 21501-2:2007, GB/T 29024.2–2016, JJG 1061–2010, SJ/T 11638–2016, GB/T 11446.3 & 11446.9–2013 |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PS-1006 |
| Breakdown Voltage Range | 0–80 kV |
| Step-Up Transformer Capacity | 1.5 kVA |
| Step-Up Rates | 2.0 / 2.5 / 3.0 / 3.5 kV/s (selectable) |
| Electrode Gap | 2.5 mm (standard) |
| Power Supply | AC 220 V ±10%, 50 ±5 Hz |
| Power Consumption | <200 W |
| Ambient Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% |
| Display | Large LCD with Chinese character interface |
| Dimensions | 760 × 670 × 770 mm |
| Weight | 48 kg |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PVM Test Fixtures |
| Pricing | Available Upon Request |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-CTH100-40 |
| Instrument Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±1.0 °C |
| Temperature Stability | ±1.0 °C |
| Humidity Uniformity | ±2.0 %RH |
| Humidity Stability | ±1.0 %RH |
| Heating Rate | −40 °C to +100 °C in ≤45 min (unloaded) |
| Brand | PW (Yuelian) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-1103F |
| Instrument Type | Coefficient of Friction (COF) Tester |
| Max Test Stroke | 6 in (150 mm) |
| Test Speed Range | 0–600 mm/min |
| Test Platform Dimensions | 5 in × 11 in (130 mm × 280 mm) |
| Load Cell Options | 10 N, 20 N |
| Power Supply | AC 220 V |
| Unit Weight | 20 kg |
| Footprint | 700 mm × 230 mm × 280 mm (W × H × D) |
| Compliance | ASTM D1894, GB/T 10006, ISO 8295 |