Physical Property Testing Instruments
Filter
Showing 8551–8580 of 12407 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable Latex Spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition, PC-based V8.3 Analysis & Calibration Software Suite |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Context | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface, iPad-compatible wireless acquisition |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.065–0.2 µm and 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with configurable particle-count alarm |
| Data Acquisition | iPad-integrated wireless acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Display | Color LCD touch interface with optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Mode | Separated civilian/military standard configuration |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail (software-configurable), GLP/GMP-compliant reporting templates |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Options | 4–20 mA analog signal,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & Touchscreen GUI) |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready configuration (optional), ISO/IEC 17025 traceable calibration workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measurement Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 4–70 µm(c), or user-defined 1–100 µm) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal + digital alarm trigger |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded touchscreen version) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance | Supports GLP audit trails, configurable report generation per ISO 4406, NAS 1638, and SAE AS4059D |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sample Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Compliance | Supports 21 CFR Part 11 audit trail (via optional software module), GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Sample Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Counting Resolution | 0.1 µm (c) minimum detectable threshold |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Analog Output | 4–20 mA |
| Data Interface | IPAD-compatible wireless acquisition system |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Origin | Shaanxi, China |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm |
| Customizable Range | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368, JJG 1061, ISO 21501-4 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.03–3000 µm (sensor-selectable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Options | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Separation Platform |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Mode | Civil & Military Standard Separation Architecture |
| Application Modes | Online continuous monitoring & offline portable/fixed measurement |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Measurement Range | 0.5–5.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c) |
| Extended Sensitivity | Down to 0.1 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501, JJG 1061, Polystyrene Latex (PSL) Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Data Output | IPAD-based acquisition system, 4–20 mA analog interface with configurable alarm triggers |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Operation Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with customizable alarm threshold |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen) |
| Compliance Support | FDA 21 CFR Part 11 audit trail ready (optional), GLP/GMP reporting modules |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm (standard) |
| Accuracy | <±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm thresholds |
| Data Acquisition | iPad-compatible wireless data capture |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Regulatory Alignment | Supports GLP/GMP audit trails, FDA 21 CFR Part 11-compliant user authentication and electronic signature options (via software configuration) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Detection Range | 0.1–1.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501, JJG 1061, NIST-Traceable Latex Spheres |
| Compliance | ChP 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alarm |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + Embedded) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination code |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 0.03 µm – 3000 µm (sensor-configurable: 2–100 µm or 4–70 µm(c)) |
| Channel Count | 16 user-selectable size channels from 1000 total bins |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Online Pressure Range | 0–0.6 MPa (standard), up to 50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Fluid 0–80 °C, Ambient −15–50 °C |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 (1) |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Measurement Range | 0.03 µm to 3000 µm (sensor-configurable: 2–100 µm or 4–70 µm(c)) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Counting Channels | 1000 adjustable size bins (up to 16 user-defined channels) |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (online) | 0–0.6 MPa (standard), 0–50 MPa (with pressure regulator) |
| Fluid Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246, ISO 11500 |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Interface | RS232 / RS485-to-USB / native USB |
| Output | 4–20 mA analog +超标 alarm (customizable) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen |
| Control | Integrated industrial PC or external IPC |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Measurement Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Data Output | 4–20 mA Analog Interface with Customizable Threshold Alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + iPad-compatible) |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Application Mode | Online Continuous Monitoring & Offline Portable/Fixed Sampling |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,800 (FOB Shanghai, ex-factory) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Detector |
| Flow Control | Precision Piston Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol IV, GB/T 18854-2015 |
| Measurement Range | 0.1–100 µm (user-configurable sub-ranges: 0.1–0.5 µm, 0.1–1.0 µm, 4–70 µm(c), or custom 1–100 µm) |
| Sample Volume Accuracy | ±1% |
| Counting Accuracy | ±3% typical (NIST-traceable latex standards) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Reporting Output | Particles/mL + ISO 4406 / NAS 1638 / SAE AS4059F contamination codes |
| Interface | 4–20 mA analog output,超标 alarm relay (customizable), iPad-compatible wireless data acquisition |
| Software | PULUODY V8.3 Analytical Suite (PC & tablet-native, 21 CFR Part 11-compliant audit trail, GLP/GMP-ready calibration logging) |
| Display | Color TFT touchscreen (7″) + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50/60 Hz |
| Compliance | Designed to meet IEST RP-CC004.3 Annex A (Wipe Cloth Extraction & Analysis Protocol), ASTM F3231-21, and JIS Z 8901 Class 5 particle counting requirements for cleanroom consumables validation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-selectable) |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog interface with customizable over-limit alarm |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Mode) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measuring Range | 0.5–5.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable超标 alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Compliance Standards | USP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Calibration Reference | NIST-traceable latex spheres or ISO 21501-4 compliant standards |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + iPad-compatible data acquisition) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor process chemicals, ultrapure water (UPW), electronic cleaning agents, flat-panel display etchants, silicon wafers, optical glass, nanofiltration permeates, polymer solutions, injectables, and insoluble particle analysis in organic solvents |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Seventh-Generation Dual-Laser Narrow-Beam Technology |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 2–100 µm or 4–70 µm(c) |
| Channel Count | 1000 adjustable size channels (up to 16 user-defined bins) |
| Accuracy | <3% typical |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80°C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-11 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Control System |
| Detection Range | 0.1–0.5 µm, 0.2–2.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±5% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Threshold-based particle count alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination等级 |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-2 compliant |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & touchscreen versions) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Ultrapure water (UPW), semiconductor process chemicals, electronic cleaning agents, silicon wafers, flat-panel display substrates, optical lenses, nanofiltration membranes, microfiltration systems, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-12 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm and 0.2–2.0 µm (standard) |
| minimum detectable size | 0.1 µm(c) |
| Sampling Method | Precision Piston Pump with Electromagnetic Flow Control |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output | 4–20 mA analog signal with configurable超标 alarm |
| Data Interface | iPad-compatible wireless acquisition system |
| Calibration Standards | JJG 1061, ISO 21501-2, or NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-13 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Detection Range | 0.1–0.5 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + mechanical precision regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±5% typical (NIST-traceable validation) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen UI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-14 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + High-Accuracy Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Measurement Range | 0.1–0.5 µm, 0.2–2.0 µm |
| Customizable Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Reporting Modes | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software Platform | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + Embedded Touch UI) |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–5.0 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable latex spheres |
| Compliance | ChP 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm triggers |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Control Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-31 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measuring Range | 0.1–1.0 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + precision piston pump |
| Accuracy | ±5% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output | 4–20 mA analog interface with configurable particle exceedance alarm |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-2 compliant |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2-33 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Measurement Range | 0.1–1.0 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±5% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | GLP/GMP audit trail capability, FDA 21 CFR Part 11–ready software architecture (user roles, electronic signatures, data integrity logging) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-4 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm, 0.5–20.0 µm, 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output,超标 alarm (customizable) |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Domain | High-purity acidic/alkaline process liquids, semiconductor CMP slurries, ultrapure water (UPW), electronic cleaning agents, photovoltaic etchants, TFT-LCD rinse solutions |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-41 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Spheres |
| Measurement Range | 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm (customizable from 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Output Interface | 4–20 mA analog output with customizable alarm trigger |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Standalone Mode) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination grade classification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-D |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard) |
| Sampling Method | Precision Piston Pump with Electromagnetic Flow Control |
| Accuracy | <±1% volumetric sampling error |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Touch Interface) |
| Output | 4–20 mA analog signal,超标 alarm relay (customizable), iPad-compatible data acquisition |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |