| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-IR500 / PW-IR1000 |
| Impact Energy Range | Configurable via drop height (0–800 mm) and ball mass (customer-specified) |
| Impact Velocity | 0.01–500 mm/min (adjustable) |
| Drop Height Range | 0–800 mm (motorized vertical adjustment) |
| Data Acquisition Rate | 100 kHz |
| Release Mechanism | Electromagnetic solenoid |
| Positioning | X-Y manual fine-adjustment for center alignment |
| Sensor Capacity | Custom-configured per test requirements |
| Power Supply | AC 220 V |
| Dimensions (L×W×H) | 500 × 300 × 1400 mm |
| Net Weight | 35 kg |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PW-PCT35B |
| Max Operating Temperature | ≤150 °C |
| Internal Chamber Dimensions (Ø×D) | 246 mm × 450 mm |
| Design Pressure Range | 0–3.0 kg/cm² (Safety Relief at 3.5 kg/cm²) |
| Time Setting Range | 0–999 h |
| Temperature Uniformity | ±2.0 °C |
| Heating Rate | RT to 132 °C in ≤35 min |
| Pressurization Time | 0–2.0 kg/cm² in ≤45 min |
| Humidity | 100 % RH (Saturated Steam) |
| Power Supply | AC 220 V, 50/60 Hz, 25 A |
| Brand | PW (Yuelian) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-SAFT20 |
| Temperature Range | Ambient +5 °C to 250 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Load Options | 0.5 kg or 1 kg (20 independent test positions) |
| Sample Area | 24 mm × 24 mm |
| Test Plate Dimensions | 72 mm × 50 mm |
| Sample Cutter Width | 24 mm |
| Timer Accuracy | ±0.5 min |
| Initial Temperature | 40 °C |
| Heating Program Control | Multi-segment ramping via touchscreen interface |
| Chamber Interior | 304 stainless steel |
| Exterior Finish | Electrostatic powder coating |
| Power Supply | 220 V, 2 kW |
| Compliance | GB/T 36794–2018 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PW-SD150LS |
| Refrigeration Method | Mechanical Compression Refrigeration |
| Temperature Range | −40 °C to +150 °C |
| Temperature Fluctuation | ±0.5 °C (ambient pressure, empty chamber) |
| Temperature Uniformity | ≤2 °C (ambient pressure to 40 kPa, empty chamber) |
| Temperature Deviation | ±0.5 °C (ambient pressure, empty chamber) |
| Ramp Rate (Heating) | ≥1 °C/min (−40 °C to +150 °C, ambient pressure, empty, average) |
| Ramp Rate (Cooling) | ≤40 min (ambient pressure to 1.0 kPa) |
| Internal Chamber Dimensions | 600 D × 500 W × 830 H mm |
| Pressure Range | Ambient (101.3 kPa) to 50 kPa |
| Pressure Control Accuracy | ±2 kPa (≥40 kPa) |
| Compressor | Bitzer or Bock semi-hermetic twin-stage cascade system |
| Vacuum Pump | Leybold oil-sealed rotary vane pump |
| Control System | Japanese Unique industrial-grade 7″ color touchscreen with PID+VRF control logic |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.21, GB/T 2423.25, GB/T 2423.26, GJB 150.1A–150.6, GB/T 10590, GB/T 5170.10, JJF 1101 |
| Brand | Yuelian (PW) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-SS10C |
| Test Angles | 90° and 180° adjustable |
| Test Stations | 10 parallel positions |
| Timer Resolution | 0.1 min, max duration 999999.9 min with battery-backed memory |
| Standard Weight | 1 kg (interchangeable weights available) |
| Frame Material | Powder-coated steel sheet |
| Vibration Damping | Integrated spring isolation system with anti-drop guard rail |
| Specimen Mounting | 10 stainless steel plates + 10 connection strips |
| Dimensions (W×D×H) | 55 × 22 × 52 cm |
| Net Weight | 35 kg |
| Compliance | GB/T 2792, GB/T 4851, PSTC-7, CNS 11888 |
| Brand | PW (Yuelian) |
|---|---|
| Model | PW-UCS80-40 |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity | Up to 100 kgf (980 N) |
| Temperature Range | –40°C to +150°C |
| Humidity Range | 20–98% RH |
| Temperature Accuracy | ±1°C |
| Speed Range | 0.01–500 mm/min |
| Force Measurement Accuracy | ≤0.5% of full scale (per ASTM E4) |
| Force Resolution | 1/1,000,000 FS |
| Displacement Resolution | 1/1,000,000 FS |
| Data Acquisition | 24-bit isolated USB 2.0 interface |
| Compliance Standards | ASTM E4, ISO 6892-1, GB/T 228.1, JIS Z2241, DIN 50125 |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-FCR2-2 |
| Pricing | Available Upon Request |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Model | PWDRP-II |
| Measurement Principle | Steady-State Heat Flow (Guarded Hot Plate / Parallel Plate Method) |
| Thermal Conductivity Range | 0.1–100 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±2% |
| Temperature Range | Ambient to 110 °C |
| Sample Forms | Solid discs, powders, pastes, liquids, adhesives, foils, and granular materials |
| Sample Diameter | Φ130 mm |
| Thickness Range | 1–100 mm |
| Heating Source | Low-voltage (36 V) copper block heater |
| Power Supply | AC 220 V, 50 Hz |
| Timer Resolution | 0.1 s (0–999.9 s) |
| Included Accessories | Two calibrated thermocouples, one aluminum reference sample, insulated test chamber, powder/paste containment frame, thermal interface compound |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-LD07 |
| Chamber Volume | ≥0.5 m³ |
| Test Voltage Range | 100–600 V AC |
| Electrode Force | 1.0 N ± 0.05 N |
| Electrode Material | Platinum |
| Droplet Volume | 44–50 drops/cm³ |
| Droplet Height Adjustment | 30–40 mm |
| Droplet Interval | 30 ± 5 s |
| Short-Circuit Current Threshold | ≥0.5 A (cut-off after 2 s) |
| Voltage Drop Limit | ≤10% at 1 A ± 0.1 A |
| Power Supply | AC 220 V / 50 Hz |
| Construction | Stainless Steel & Brass Housing |
| Compliance | IEC 60112, IEC 60335-1, GB/T 4207, GB 4706.1, GB 2099.1, VDE 0620 |
| Brand | Product Intelligence and Creativity |
|---|---|
| Origin | Beijing, China |
| Model | PZ-1000SD-A |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 120 × 180 mm |
| Optical Magnification | 0.7–4.5× |
| Surface/Interfacial Tension Range | 0–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Heating System | Programmable High-Temperature Furnace (up to 1600 °C), 30-Step Ramp/Soak Control, ±0.1 °C Stability ≤1000 °C |
| Vacuum System | Molecular Pump, Wide-Range Vacuum Gauge |
| Imaging System | Monochrome Industrial CCD Camera (130 W pixels, 25 fps), Telecentric Zoom Lens |
| Light Source | Adjustable Blue-Tone LED Cold Illumination (Lifespan >25,000 h) |
| Software | Automated Image Analysis Suite with Circle, Ellipse, Oblique Ellipse, Differential Circle/Ellipse, and Dynamic Video Sequence Fitting Algorithms |
| Compliance | GB/T 24368-2009, SY/T 5153-2007, ASTM D724-99(2003), ASTM D5946-2004, ISO 15989 |
| Brand | Product Intelligence & Creativity |
|---|---|
| Origin | Beijing, China |
| Model | PZ-E2 |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | 0–100 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Test Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sample Volume Requirement | ≥3 mL (plate), ≥5 mL (ring) |
| Power Consumption | 100 W |
| Dimensions (L×W×H) | 20 × 35 × 35 cm |
| Weight | 7.5 kg |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | AIM Box |
| Compliance | ASTM G201, GM 2617M/3619M/7454M/7455M/9538P, Ford DVM 0020, GMW 3417 |
| Light Source | Natural Sunlight with Automotive Glass Filtering |
| Tracking System | Dual-Axis Solar Tracker |
| Temperature Control | Blackboard Thermometer + Active Air-Cooling Fan |
| Sample Capacity | Full-size automotive interior components (dashboards, seats, steering wheels) |
| Spectral Filtering | OEM-grade laminated automotive glass (windshield or side-glass variants per test standard) |
| Operating Environment | Outdoor field exposure site (e.g., Arizona) |
| Calibration & Traceability | ISO/IEC 17025-accredited testing methodology |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT-600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray, Dry, 100% RH Humidity, and Hold (Static) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford APGE, VW PV1210, Renault D17 2028 |
| Water Requirement | Deionized or purified water only |
| Internal Solution Reservoir | 120 L with level sensor and saltwater filter |
| Controller | Integrated microprocessor-based system with self-diagnostic functions, service alerts, and safety shutdown |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Chamber Type | Cyclic Corrosion Test Chamber |
| Core Functions | Salt Spray / Dry / High-Humidity (100% RH) Cycling |
| Compliance | ASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, ISO 11997, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210 |
| Control System | Integrated Q-FOG Microprocessor Controller with Real-Time Display and Programmable Cycle Sequencing |
| Chamber Volume | 1100 L (Standard Configuration) |
| Construction | Fiberglass-Reinforced Polymer (FRP) Cabinet with Corrosion-Resistant Interior |
| Humidity Generation | Electric Steam Generator |
| Salt Fog Delivery | Compressed-Air-Driven Atomization via Bubble Tower (except Prohesion mode) |
| Temperature Control | Dual-Heater System (Chamber + Air Stream) |
| Viewing Window | Polycarbonate Side Window with Sealed Gasket |
| Data Logging | Onboard Event Timestamping (Start/Stop/Phase Transition), Optional USB Export |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB CCT1100 |
| Chamber Volume | 1103 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Operating Modes | Salt Spray / Prohesion / 100% RH Humidity / Dry / Static |
| Temperature Range | Ambient to 50 °C (typical operational range per ASTM B117, ISO 9227, SAE J2334) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated air pressure |
| Water Requirement | Deionized or purified water (≥1 MΩ·cm resistivity recommended) |
| Compliance | Designed to meet ASTM G85 Annexes A1–A5, ISO 11997-1/2, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray / Dry / 100% RH / Static |
| Compliance | ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, Volvo VCS 1027,149, GB/T 10125 |
| Humidity Control | Up to 100% RH with precision air pre-conditioning (CCT-series) |
| Temperature Range | Ambient +10°C to 50°C (operational during spray/dry/RH phases) |
| Salt Solution Delivery | Variable-speed peristaltic pump with independent control of solution flow rate and atomization distance via regulated compressed air |
| Controller | Q-FOG Intelligent Touchscreen Controller with built-in diagnostics, service scheduling, safety shutdown, and audit-trail-ready event logging |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB CCT600 |
| Chamber Capacity | 640 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Operating Environments | Salt Fog / Dry / 100% RH Humidity / Ambient Hold |
| Temperature Range | Ambient to 50 °C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated air pressure |
| Internal Solution Reservoir | 120 L with level sensor and filtration |
| Compliance | Designed to support ASTM B117, ISO 9227, ASTM G85 Annexes (A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, and other internationally recognized cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH 1100 |
| Capacity | 1100 L (internal chamber volume) |
| Humidity Control Range | 0–100% RH (programmable, pulse-fogging assisted) |
| Temperature Range | Ambient +10°C to 60°C (typical operational range per ASTM G85 Annexes and ISO 16701) |
| Spray Function | Adjustable flow rate, user-defined on/off timing, non-atomized liquid delivery |
| Compliance | Fully supports GMW 14872, SAE J2334, ISO 16701, ASTM G85 Annexes 1/2/3/5, ISO 9227, IEC 60068-2-52, MIL-STD-810G, and other cyclic corrosion standards requiring precise RH control |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH600-HSC / CRH1100-HSC |
| Salt Fog Deposition Rate | Adjustable via precision peristaltic pump and air pressure regulation |
| Temperature Range | 10°C to 70°C (operational), with rapid transition capability |
| Relative Humidity Control | 10% to 95% RH, ±2% RH accuracy (at 25°C) |
| Chamber Capacity | 640 L (CRH600-HSC) or 1103 L (CRH1100-HSC) |
| Spray Nozzle System | Self-cleaning, modular, DI-water compatible |
| Internal Solution Reservoir | 120 L, with level sensor and particulate filtration |
| Compliance | Designed to meet GMW 14872, SAE J2334, ISO 11997, ASTM B117 (modified), VW PV1210, Ford CETP, Renault D17 2025, GB/T 24135–2009, and other automotive & industrial cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100-HSC |
| Spray Mode | Continuous/Cyclic Spray |
| Temperature Range | 20–70 °C |
| Chamber Volume | 1103 L |
| Humidity Control | Full-Variable RH via Air Preconditioning System |
| Spray Function | Adjustable High-Flow Liquid Shower Module |
| Nozzle Maintenance | Automatic Self-Cleaning Mechanism |
| Internal Solution Reservoir | 120 L with Filtration & Low-Level Alarm |
| Compliance | GMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600 |
| Chamber Volume | 640 L |
| Salt Spray Deposition Rate | Adjustable per ASTM B117 / ISO 9227 |
| Temperature Range | 10–70 °C (operational), with RH control from 10% to 95% RH |
| Humidity Control Method | Pre-conditioned air + ultrasonic misting + forced-air circulation |
| Compliance | GMW 14872, SAE J2334, Ford CETP, ISO 16701, VW PV1210, Renault D17 2025, Volvo VCS 1027, Chrysler MSFC-100, GB/T 10125, ISO 9227, ASTM G85 Annex A5 (Prohesion) |
| Brand | Q-LAB |
|---|---|
| Origin | China (Hubei) |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PWC |
| Quotation | Available Upon Request |
| Xenon Lamp Power | Configurable per IEC 60068-2-5 & ASTM G155 |
| Temperature Range | –10°C to +80°C (operational, ±0.5°C uniformity) |
| Humidity Range | 10% to 95% RH (±3% RH accuracy) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50°C (operational control stability ±2°C) |
| Salt Solution Delivery | Pneumatic air-assisted atomization with adjustable spray rate (typically 1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Humidity Control | 100% RH capability (CCT-specific) |
| Chamber Volume | Standard 600 L (custom sizes available) |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body with corrosion-resistant stainless steel hardware |
| Control System | 7-inch full-color touchscreen interface with programmable multi-step cycling logic |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Chamber Volume Options | 600 L / 1100 L |
| Temperature Range | Ambient to 50°C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Pneumatic atomization via saturated compressed air and adjustable peristaltic pump |
| Humidity Control | 100% RH via steam generator (CCT-specific) |
| Dry Cycle | Forced-air convection heating with dual heater control (chamber + air heater) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A1–A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, DIN 50017, JIS Z2371 |
| Software Interface | Q-FOG Touchscreen Controller with programmable multi-step cyclic profiles, real-time monitoring, data logging, and audit-ready event history |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Compliance | ASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, Renault D17 2028 |
| Chamber Capacity | 640 L (CCT-600) / 1103 L (CCT-1100) |
| Temperature Range | 10–70 °C (operational range under cyclic conditions) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated compressed air |
| Humidity Control | 100% RH capability (CCT only) |
| Sample Capacity | 160 specimens (75 mm × 150 mm) for CCT-600 |
| Internal Reservoir | 120 L deionized water tank with integrated salt solution filter and low-level alarm |
| Cycle Flexibility | Four-phase cycling — Salt Fog, Dry-off, 100% RH (CCT only), and Ambient Rest |
| Controller | Embedded microprocessor with self-diagnostic firmware, audit-trail-capable logging (FDA 21 CFR Part 11 compliant configuration available), and intuitive touchscreen interface |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT |
| Compliance | ASTM B117, ISO 9227, ISO 11997, ASTM G85 (Annex A1–A5), SAE J2334, GMW 14872, VDA 621-415, JIS Z 2371, DIN 50021, BS EN ISO 7253 |
| Humidity Range | 100% RH (CCT-specific) |
| Temperature Control | Spray, Dry, and Humidify Modes with Independent Heating Systems |
| Chamber Capacity | Standard configurations available (e.g., CCT-1100, CCT-2100) |
| Control System | Touchscreen Programmable Controller with Multi-Step Cycling Capability |
| Construction | Fiberglass-Reinforced Polymer (FRP) Cabinet, Corrosion-Resistant Interior |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT Series |
| Type | Cyclic Corrosion Test Chamber |
| Compliance | ASTM B117, ISO 9227, ASTM G85 (Annexes A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210 |
| Temperature Range | 10–70 °C (operational range per test method) |
| Humidity Control | 100% RH (CCT only) |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Chamber Volume | Available in multiple standard sizes (e.g., CCT-1100: 1100 L) |
| Controller | Q-FOG Touchscreen Microprocessor with Multi-Step Program Logic, Audit Trail Logging, and User Access Levels |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT SSP CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (CCT-600/SSP-600/CRH-600) or 1103 L (CCT-1100/SSP-1100/CRH-1100) |
| Internal Salt Solution Reservoir | 120 L |
| Sample Rack Capacity | 160 pcs (75 mm × 150 mm) for 600-series |
| Relative Humidity Control | 95–100% RH (CCT), fully adjustable 10–95% RH (CRH) |
| Air Pressure Requirement | 3–10 bar |
| Water Purity | <8 ppm TDS, resistivity >50 kΩ·cm |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT-1100 |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 1103 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Humidity Control | Up to 100% RH |
| Cycle Modes | Salt Spray, Dry, High Humidity (100% RH), and Hold/Rest |