Physical Property Testing Instruments
Filter
Showing 10651–10680 of 12275 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJPL-3KN |
| Max Test Load | 3 kN |
| Frequency Range | 0.001–10 Hz (amplitude-dependent) |
| Actuator Stroke | 50 mm (adjustable mid-stroke) |
| Effective Test Width | 60 mm × 3 stations |
| Max Spring OD | ≤60 mm |
| Max Free Length | ≤240 mm |
| Amplitude Range | 0.001–50 mm |
| Load Accuracy Class | 0.5 |
| Load Measurement Range | 0.2–100% FS |
| Load Resolution | 1/30,000 full scale (10 kHz dynamic sampling) |
| Displacement Measurement Accuracy | ±0.002 mm |
| Deformation Accuracy | ±1% of reading |
| Speed Control | Dual-speed (fast/slow), jog-capable |
| Safety Features | Mechanical limit switches, overload protection (10% over capacity), automatic return post-test |
| Power Supply | 220 V AC, 2 kW |
| Host Weight | ~850 kg |
| Included | 10 custom spring compression fatigue fixtures (dimensionally matched to user-provided samples), proprietary fatigue control software suite (with backup DVD), operation manual & interface cables |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System |
| Compressor | Imported Semi-Hermetic German Compressor |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, EIA-364-32, QC/T 17–92 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (FOB) |
| Power Supply | AC 380 V ±10%, 50/60 Hz |
| Refrigerants | R404A & R23 (EPA-approved) |
| Compressor | Tecumseh or Copeland High-Performance Hermetic Units |
| Cooling System | Dual-Stage Cascade Mechanical Refrigeration with Water-Cooled Condenser |
| Temperature Control | Touchscreen LCD Controller with RS232 Interface |
| Compliance | GB/T 2423.1–1989 (Test A), GB/T 2423.2–1989 (Test B), IEC 60068-2-1, MIL-STD-2164A, GJB 1032–1990, GJB 234–1985 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Load Capacity | 800 kg |
| Peak Thrust | 150 kN |
| Frequency Range | 10–55 Hz |
| Peak-to-Peak Displacement | 1.5 mm |
| Table Dimensions | 1500 × 1500 mm |
| Max Acceleration | 9 g |
| Vibration Axis | Vertical (Single-Axis Operational Mode) |
| Control Modes | Fixed-Frequency & Sweep Testing |
| Table Material | Anodized Aluminum Alloy |
| System Architecture | Electro-hydraulic Servo with High-Pressure Hydraulic Power Unit (HPU) and Real-Time PC-Based Controller |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Frequency Range | 1–600 Hz |
| Max. Load Capacity | 100 kg |
| Peak Acceleration | 20 g |
| Adjustable Peak-to-Peak Amplitude | 0–5 mm |
| Table Surface Dimensions (L×W) | 50 × 50 cm |
| Shaker Power Rating | 2.2 kW |
| Control Modes | Sine, Amplitude Modulation (AM), Fixed-Frequency Sine, Programmable Sweep, Logarithmic Sweep, Octave Sweep, Time-Controlled Operation |
| Communication Interface | RS-485 |
| Power Supply | 220 V ±20%, Max. Current: 10 A |
| Frequency Resolution | 0.01 Hz (display), Accuracy: ±0.1 Hz |
| Operating Axes | Vertical, Horizontal, or Combined Triaxial (X/Y/Z) |
| Brand | AiYao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRT |
| Pricing | Available Upon Request |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BT-2 |
| Instrument Type | Thermo-Hygrometer |
| Temperature Range (Internal) | –30 °C to +50 °C (–22 °F to +122 °F) |
| Temperature Range (External Probe) | –50 °C to +70 °C (–58 °F to +158 °F) |
| Humidity Range | 20–99 % RH |
| Temperature Resolution | 0.1 °C/°F |
| Humidity Resolution | 1 % RH |
| Temperature Accuracy | ±1 °C |
| Humidity Accuracy | ±5 % RH (at 25 °C) |
| Power Supply | 1 × 1.5 V AAA alkaline battery (optional) |
| Dimensions (H×W×D) | 111 × 101 × 21.5 mm |
| Display Area | 81.5 × 64.5 mm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BT-2 |
| Instrument Type | Digital Thermo-Hygrometer |
| Temperature Range (Internal) | –30 °C to +50 °C (–22 °F to +122 °F) |
| Temperature Range (External Probe) | –50 °C to +70 °C (–58 °F to +158 °F) |
| Humidity Range | 20–99% RH |
| Temperature Resolution | 0.1 °C/°F |
| Humidity Resolution | 1% RH |
| Temperature Accuracy | ±1 °C |
| Humidity Accuracy | ±5% RH (at 25 °C) |
| Power Supply | 1 × 1.5 V AAA alkaline battery (included) |
| Dimensions (H×W×D) | 111 × 101 × 21.5 mm |
| Display Area | 81.5 × 64.5 mm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JH50, JH70, JH90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step adjustable) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per batch |
| Display | TFT high-definition color LCD |
| Data Storage | 8 GB internal |
| Image Capture | Still frame capture with real-time video streaming |
| Video Playback | Local playback supported |
| Connectivity | USB, RS-232, Ethernet |
| Power Supply | 220 VAC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | LHH-800SD |
| Temperature Range | 0–65 °C |
| Max Operating Temperature | ≤150 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±2 °C |
| Temperature Deviation | ±2 °C |
| Ramp-up Time (to 65 °C) | 20 min |
| Internal Chamber Dimensions (W×H×D) | 965×1430×580 mm |
| Humidity Range | 40–90 %RH |
| Humidity Accuracy | ±3 %RH |
| Illumination Control | Optional (0–6000 lx, stepless adjustment) |
| Refrigeration System | Dual independent imported hermetic compressors with auto-switching logic |
| Controller Type | Programmable touchscreen (SDP/GSP series), LCD display (SD/GSD series) |
| Sensor Types | Pt100 RTD (temperature), capacitive humidity sensor |
| Compliance Support | IQ/OQ/PQ validation documentation available |
| Power Supply | AC 220 V / 50 Hz or AC 380 V / 50 Hz |
| Safety Protections | Over-temperature, compressor overheat/overpressure, fan overheat, overload, low-water, audible/visual alarms |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LND-2 |
| Instrument Category | Efflux Viscometer |
| Mounting Type | Benchtop Fixed |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 30–100 s (efflux time) |
| Temperature Range | 20–25 °C (standard test condition) |
| Temperature Resolution | Not applicable (non-temperature-controlled) |
| Temperature Accuracy | Not applicable (non-temperature-controlled) |
| Calibration Standards | ASTM D1200, ISO 2431, GB/T 1723–1993 |
| Measurement Error | ±3% of reading |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDJ-1 Ultra-Low Viscosity |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.1–2,000,000 mPa·s |
| Speed Settings | 6, 12, 30, 60 rpm (manual gear shift) |
| Accuracy | ±5% (for Newtonian fluids) |
| Spindle Set | #0, #1, #2, #3, #4 |
| Gear Ratio Units | I (1:1), II (1:10, 1:100), III (×0.1, ×0.2, ×0.4, ×0.5) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDJ-4 High-Viscosity |
| Instrument Category | Rotational Viscometer (Analog, Spindle-Based) |
| Form Factor | Benchtop (Non-Portable) |
| Operating Environment | Ambient Temperature (15–30 °C) |
| Viscosity Range | 10–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | No. 1–4 (standard) |
| Accuracy (Newtonian fluids) | ±5% full scale |
| Display | Analog dial with mechanical pointer |
| Dimensions | 275 × 265 × 445 mm |
| Weight | ~12.5 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-79 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–1×10⁶ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Measuring Systems | Three interchangeable spindles (Units I, II, III) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 170 × 140 × 440 mm |
| Weight | 15 kg |
| Operating Environment | Ambient temperature (no integrated temperature control) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-8S |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 0.1–2,000,000 mPa·s (with appropriate spindle and speed selection) |
| Speed Settings | 6, 12, 30, 60 rpm |
| Spindles | LV#1–#4 (standard set) |
| Display | Digital LCD with bilingual (English/Chinese) interface |
| Measurement Accuracy (Newtonian fluids) | ±5% of full scale |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | Ambient temperature (10–35 °C), <80% RH non-condensing |
| Compliance | Designed per GB/T 2794–2013 (China National Standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–2% (displayed as % vol when ≥1% |
| Accuracy | ±1.0% of full scale |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | <90% RH (non-condensing) |
| Interference Restrictions | Excludes CH₄, SO₂, H₂S, Cl₂, NH₃, and other corrosive or spectrally overlapping gases |
| Power Supply | AC 220 V, 50–60 Hz / DC 12 V (rechargeable Ni-MH battery onboard) |
| Power Consumption | ≤3 W (DC mode) |
| Dimensions | 210 × 90 × 230 mm |
| Weight | 2.0 kg |
| Response Time (t₉₀) | ≤50 s |
| Display | Backlit Chinese-language LCD |
| Data Output | Integrated thermal printer (real-time printout of measurement records) |
| Auto-Sampling Interval | Programmable timed measurement cycles |
| Compliance | Designed per IEC 61000-6-3 (EMC), GB/T 18204.2–2014 (Chinese standard for CO₂ detection in indoor air), and general industrial safety requirements for portable gas analyzers |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3A |
| Measurement Range | 0–1.5% (w/w) |
| Accuracy | ±2.5% |
| Display | Chinese LCD interface |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 450 mm × 305 mm × 550 mm (H) |
| Weight | 15 kg |
| Data Storage Capacity | 63 entries per sample type (beer + soft drinks) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature (15–30 °C) |
| Viscosity Range | 0.1–2,000,000 mPa·s |
| Speed Settings | 6 / 12 / 30 / 60 rpm |
| Rotor Set | L1–L4 (ISO/DIN-compatible spindles) |
| Display | Digital LCD with Dual-Language UI (English/Chinese) |
| Power Input | 110–240 V AC, 50/60 Hz |
| Accuracy (Newtonian Fluids) | ±2% of full scale |
| Viscosity Measurement Principle | Couette flow via rotating spindle in stationary sample cup |
| Compliance | Designed to meet ISO 2555, ASTM D2196, and GB/T 2794 standards for rotational viscosity testing |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1A |
| Melting Point Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Linear Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable) |
| Accuracy | ±0.5 °C below 200 °C |
| Sample Capacity | 3 positions (simultaneous) |
| Display | Backlit LCD with real-time melting curve visualization |
| Interface | RS232 for data export |
| Dimensions | 398 × 280 × 170 mm |
| Weight | 11 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Compliance | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TS2 / TS3 |
| Pricing | Upon Request |
| High-Temperature Range | +60 °C to +200 °C |
| Low-Temperature Range | 0 °C to –55 °C or 0 °C to –65 °C |
| Temperature Transition Time | ≤10 s |
| Temperature Recovery Time | 3–5 min |
| Test Load Capacity | 1.0–20.0 kg |
| Internal Chamber Dimensions (W×D×H) | 200×200×150 mm to 650×500×400 mm |
| Compliance | MIL-883E, IEC 60068-2-14, JIS C 60068-2-14 |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSC-1M-4 |
| Price | Upon Request |
| Hp Measurement Range | ±2000 A/m |
| Number of Measurement Channels | 2–4 (configurable per probe) |
| Minimum Step Size | 1 mm |
| Maximum Step Size | 128 mm |
| Max Scanning Speed (at 1 mm step) | 0.2–0.5 m/s |
| Basic Relative Error per Channel (Hp) | ±5% |
| Length Measurement Relative Error | <5% |
| Microprocessor | 8-bit |
| RAM Capacity | 128 kB |
| Flash Memory | 4 MB |
| Display | 128×64-pixel monochrome LCD with real-time waveform plotting |
| Data Transfer Interface | RS-232 @ 115 kbps |
| Keypad | 45-key bilingual (English/Russian) tactile keyboard |
| Power Supply | 4×AA NiMH (1.2 V) or alkaline (1.5 V) batteries |
| Power Consumption | 0.8–3.0 V·A |
| Operating Temperature | −15 °C to +55 °C |
| Relative Humidity | 45–85 % RH |
| Dimensions | 230 × 105 × 40 mm |
| Weight | 0.5 kg |
| Probe Types | Type 1 (4-channel wheeled cart, integrated length encoder), Type 2 (2-channel single-wheel probe for small components), Type 3 (2-channel dual-wheel probe for complex geometries and small-diameter pipes), Type 4 (2-channel contact probe without encoder, for confined-access areas) |
| Auto-calibration | Yes, sensor-level real-time compensation |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSC-2M-8 |
| Pricing | Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7415, 7425 |
| Temperature Sensor | Thermistor |
| Temperature Range | 0–60°C |
| Temperature Accuracy | ±0.6°C at 25°C (with ±0.03°C/°C thermal drift compensation) |
| Temperature Resolution | 0.1°C |
| Relative Humidity Sensor | Thin-film Capacitive |
| RH Range | 5–95% RH |
| RH Accuracy | ±3% RH at 25°C (with ±0.2% RH/°C thermal drift compensation |
| RH Resolution | 0.1% RH |
| Operating Temperature (Instrument) | 5–45°C |
| Operating Temperature (Probe) | −10–60°C |
| Storage Temperature | −20–60°C |
| Data Memory Capacity | 12,700 measurements across 100 data sets |
| Logging Interval | 1 s to 1 h |
| Time Constant | User-configurable |
| Dimensions (Instrument) | 8.4 × 17.8 × 4.4 cm |
| Probe Dimensions | 17.8 cm length × 1.9 cm diameter |
| Weight | 270 g |
| Power Supply | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | QUESTemp° 32 / 34 / 36 |
| Sensor Technology | Traditional Wet-Bulb (Cotton Wick) |
| IP Rating | IP54 |
| Compliance | UL/CSA Class I, II, III |
| Operating Temperature (Sensor) | –5 °C to 100 °C |
| Battery Life (Alkaline) | 140 h |
| Data Logging Intervals | 1–60 min adjustable |
| WBGT Calculation | ISO 7243, ACGIH, NIOSH, OSHA compliant |
| Software | TSI DMS (Data Management Software) |
| Measurement Parameters | Dry-Bulb Temp, Wet-Bulb Temp (wetted wick), Globe Temp, Relative Humidity, Air Velocity, Indoor/Outdoor WBGT, HUMIDEX, PMV/PPD (per ISO 7730) |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | TSY Series |
| Pricing | Available Upon Request |
| X-ray Tube Voltage Range | 20–225 kV |
| Tube Current Range | 1–50 mA |
| High-Voltage Generator Weight | 210 kg |
| Cooling System | TZL-30 (integrated) or TZL-30F (split-type), temperature control range: 0–50 °C, accuracy: ±0.5 °C |
| Water Flow Rate | 1.6–3.0 L/min |
| Output Pressure | 2.5–4 kg/cm² |
| Control Interface | Color TFT touchscreen, Chinese-language UI |
| Safety Interlocks | Overcurrent, overvoltage, undervoltage, undercurrent, water flow loss, overheating, door interlock |
| Brand | FRT |
|---|---|
| Origin | Germany |
| Model | MicroProf MHU |
| Wafer Handling | Semi-Automatic with Material Handling Unit (MHU) |
| Throughput | Up to 220 wafers/hour |
| Wafer Diameter Support | 2″ to 8″ |
| Cassette Capacity | Up to 4 open FOUPs/SMIF pods |
| Integrated Options | Pre-aligner, OCR reader |
| Application Focus | Semiconductor, MEMS, Sapphire, LED wafer manufacturing |
| Brand | Tuofeng |
|---|---|
| Model | BW-20 |
| Type | Electromechanical Tensile Testing Machine |
| Max Test Load | 20 kN |
| Load Measurement Range | 0.2–100% of full scale |
| Load Accuracy | ±0.5% of reading |
| Crosshead Travel | 800 mm |
| Displacement Resolution | 0.0001 mm |
| Positioning Accuracy (Displacement) | ±0.5% of reading |
| Speed Range | 0.01–500 mm/min |
| Test Space (Width × Height) | 400 mm × 800 mm |
| Frame Type | Dual-column Portal Structure |
| Dimensions (W×D×H) | 780 × 560 × 1780 mm |
| Weight | ~200 kg |
| Compliance | JC/T 992–2006, JC/T 993–2006, JC/T 547–2005, JG 149–2003, JC 890–2001, JC/T 907–2002, JG 158–2004, DBJ 01-38–2002, DBJ/T 01-50–2002 |
| Brand | Tuofeng |
|---|---|
| Model | GDW |
| Type | Electromechanical Universal Testing Machine |
| Max Test Load | 5–100 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% FS |
| Force Error | ±0.5% of reading |
| Force Resolution | 1/500,000 of full scale (ungraded, constant throughout) |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Error | ±0.5% of reading |
| Deformation Resolution | up to 1/300,000 |
| Displacement Error | ±0.5% of reading |
| Column Spacing | 840 mm |
| Crosshead Travel (standard) | 1000 mm |
| Host Dimensions | 1250 × 560 × 2400 mm |
| Power Supply | AC 220 V / 50 Hz ±10%, 750 W |
| Weight | ~380 kg |
| Environmental Chamber Temp Range | −40 °C to +100 °C |
| Chamber Heating Power | 1500 W |
| Chamber Internal Dimensions | 360 × 300 × 500 mm (W × D × H) |
| Chamber Construction | 304 stainless steel exterior, 316 mirror-finish stainless interior, ceramic fiber insulation |
| Temperature Control | Programmable PID with Pt100 sensors |
| Temp Uniformity | ±2 °C over 100 mm axial zone |
| Heating Rate | ≤30 min to +100 °C from ambient |
| Thermal Equilibration Time | ≤5 min (both below and above 0 °C) |
| Safety Features | Leakage current protection, overcurrent circuit breaker |
| Brand | Tuofeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HGD |
| Price Range | USD 2,800 – 7,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 100 kN |
| Force Measurement Range | 0–100 kN (Full Scale) |
| Force Accuracy | ±0.5% of reading |
| Test Stroke | 1000 mm |
| Displacement Resolution | 0.0001 mm |