| Brand | Topfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TF-W |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Force | 100 kgf (≈ 0.98 kN) |
| Force Measurement Range | 0.2%–100% of Full Scale |
| Force Accuracy | ±0.5% FS |
| Test Stroke | 400 mm |
| Displacement Resolution | 0.001 mm |
| Voltage Supply | AC 220 V |
| Speed Range | 5–350 mm/min |
| Dimensions (W×D×H) | 380 × 450 × 1000 mm |
| Weight | 60 kg |
| Brand | TopFeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TFW-100S |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 100 kN |
| Accuracy Class | 0.5 |
| Effective Force Range | 0.2–100% of Full Scale |
| Force Measurement Accuracy | ±0.005% of Reading |
| Force Resolution | 1 / ±300,000 counts (full-scale, no range switching) |
| Drive System | Servo Motor with Worm Gear Reducer |
| Lead Screw | High-Precision Ball Screw |
| Effective Test Width | 500 mm (customizable) |
| Tensile Stroke | 800 mm (customizable) |
| Test Speed Range | 0.01–500 mm/min (optional extended range) |
| Displacement Measurement | Optical Encoder |
| Displacement Accuracy | ±0.005% of Reading |
| Strain Measurement (Optional) | Extensometer with Gauge Lengths 25/50/100 mm |
| Safety Protection | Electronic Limit Switches, Emergency Stop Button |
| Crosshead Adjustment | Dual-Speed Motorized (Fast/Slow), Jog Control |
| Return Function | Automatic or Manual Return at Maximum Speed Post-Test |
| Overload Protection | Automatic Shutdown at >110% of Rated Load |
| Fixture Customization | Application-Specific Clamping Solutions |
| Dimensions (W×D×H) | 1000 × 600 × 2000 mm |
| Power Supply | 220 V AC, 3000 W |
| Approx. Weight | 800 kg |
| Brand | TopFeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TFW-199 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Electromechanical Tensile Tester |
| Maximum Test Load | 200 kN |
| Force Measurement Range | 0.4–100% of Full Scale |
| Force Accuracy | ±0.5% of reading |
| Crosshead Travel | 1000 mm |
| Displacement Resolution | 0.0001 mm |
| Brand | TopFeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TFW-200S |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Test Load | 200 kN |
| Accuracy Class | ISO 5893 Class 0.5 |
| Effective Force Range | 0.2–100% of Full Scale |
| Force Measurement Accuracy | ±0.005% of Reading |
| Force Resolution | 1 part in ±300,000 of Full-Scale Load (Single-Range, Constant Resolution) |
| Drive System | Servo Motor with Precision Worm Gear Reducer |
| Lead Screw | High-Accuracy Ball Screw |
| Effective Test Width | 600 mm (customizable) |
| Max. Travel Distance | 600 mm (customizable) |
| Speed Range | 0.01–500 mm/min (standard), optional extended range |
| Displacement Measurement | Optical Encoder |
| Displacement Accuracy | ±0.005% of Reading |
| Strain Measurement (Optional) | Extensometer (gauge lengths: 25/50/100 mm |
| max. extension | 5/10/25 mm) or Large-Deformation Clip Gauge (min. gauge length: 10 mm |
| max. extension | 800 mm) |
| strain accuracy | ±0.005% of reading |
| Safety Protection | Electronic Limit Switches, Emergency Stop Button |
| Crosshead Adjustment | Dual-Speed Motorized (Fast/Slow), Jog Control |
| Return Function | Automatic or Manual Return to Initial Position at Maximum Speed Post-Test |
| Overload Protection | Automatic Shutdown at >110% of Rated Load |
| Fixture Customization | Application-Specific Grips Available |
| Dimensions (W×D×H) | 1100 × 900 × 2600 mm |
| Power Supply | 380 V AC, 4 kW |
| Approx. Weight | 1500 kg |
| Brand | Topfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TFW-218 |
| Instrument Type | Electromechanical Tensile Testing Machine |
| Maximum Test Load | 5000 kN |
| Load Measurement Range | 0.2–100% of Full Scale |
| Load Accuracy | ±0.5% FS |
| Test Stroke | 25 m |
| Displacement Resolution | 0.0001 mm |
| Brand | Topfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromechanical Universal Testing Machine |
| Model | TFW-317 |
| Load Capacity Range | 0.02 N to 300 kN |
| Load Accuracy | ±0.5% |
| Temperature Chamber Range | −40 °C to +100 °C |
| Temperature Control Accuracy | ±2 °C (longitudinal 100 mm) |
| Vertical Test Space (standard) | 1000 mm |
| Column Internal Width | 840 mm |
| Host Dimensions | 1250 × 560 × 2400 mm |
| Weight | ~380 kg |
| Power Supply | AC 220 V / 50 Hz ±10%, 750 W (host) |
| Brand | Topfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TFW-319 |
| Price Range | USD 1,400 – 28,500 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0.02 N to 300 kN |
| Load Accuracy | ±0.5% FS |
| Force Measurement Range | 0.4–100% of Full Scale |
| Force Resolution | 1/500,000 of Maximum Load |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Accuracy | ±0.5% of Reading |
| Displacement Accuracy | ±0.5% of Reading |
| Column Spacing | 840 mm |
| Test Space (Vertical) | Up to 1000 mm |
| Host Dimensions | 1250 × 560 × 2400 mm |
| Power Supply | AC 220 V / 50 Hz ±10%, 750 W |
| Weight | ~380 kg |
| Environmental Operating Range | +5 °C to +35 °C |
| Temperature Chamber Range | −40 °C to +100 °C |
| Chamber Internal Dimensions | 360 × 300 × 500 mm (W×D×H) |
| Heating Power | 1.5 kW |
| Cooling Method | Compressor-based refrigeration |
| Temperature Uniformity | ±2 °C over 100 mm axial zone |
| Ramp Rate | ≤30 min to reach +100 °C from ambient |
| Thermal Equilibration Time | ≤5 min (both above and below 0 °C) |
| Chamber Construction | 304 Stainless Steel Exterior / 316 Mirror-Finish Stainless Steel Interior |
| Insulation | Alumina-silica fiber |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Viewing Window | Double-sealed thermal glass |
| Safety Systems | Leakage current protection, overcurrent circuit breaker |
| Brand | Topfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TFW-5S |
| Instrument Type | Electronic Universal Testing Machine |
| Maximum Test Load | 5 kN (500 kgf) |
| Accuracy Class | 0.5 |
| Effective Force Measurement Range | 0.2%–100% of Full Scale |
| Force Measurement Accuracy | ±0.005% of Reading |
| Force Resolution | 1/±500,000 codes (full-scale, no range switching, constant resolution) |
| Drive System | Servo Motor with Worm Gear Reducer |
| Lead Screw | High-Precision Ball Screw |
| Effective Test Width | 370 mm (customizable) |
| Tensile Stroke | 800 mm (customizable) |
| Test Speed Range | 0.01–500 mm/min (optional extended range) |
| Displacement Measurement | Optical Encoder |
| Displacement Accuracy | ±0.005% of Reading |
| Strain Measurement | Optional Extensometer or Large-Deformation Sensor |
| Strain Accuracy | ±0.005% of Reading |
| Safety Protection | Electronic Limit Switches, Emergency Stop Button |
| Crosshead Adjustment | Dual-Speed (Fast/Slow) Motorized Control with Jog Function |
| Return Function | Automatic or Manual High-Speed Return to Initial Position |
| Overload Protection | Auto-shutdown at >110% of Rated Load |
| Fixture Customization | Application-Specific Fixtures Available |
| Dimensions (W×D×H) | 650 × 400 × 1680 mm |
| Power Supply | 220 V AC, 750 W |
| Net Weight | ~280 kg |
| Brand | TopFeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | TFW-85 |
| Instrument Type | Electronic Universal Testing Machine |
| Maximum Test Load | 200 kN |
| Force Measurement Range | 0.2%–100% of Full Scale |
| Force Accuracy | ±0.5% of reading |
| Crosshead Travel | 1000 mm |
| Displacement Resolution | 0.001 mm |
| Control System | PC-based with Windows OS |
| Compliance | GB/T 16491–2008, JJG 475–2008, ASTM E4, ASTM E8, ISO 6892-1, DIN 50125, JIS Z 2241, BS EN ISO 6892-1 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-1106F |
| Load Capacity | 50 N |
| Measurement Accuracy | ±1% FS |
| Resolution | 0.01 N |
| Crosshead Speed Range | 0.5–500 mm/min |
| Stroke | 200 mm |
| Power | 40 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Dimensions (W×L×H) | 360 × 380 × 520 mm |
| Net Weight | 17 kg |
| Standard Accessories | Host unit, 1 sampling cutter, 10 stainless steel test plates |
| Compliant Test Standards | ASTM D6195, TLMI TT-001, FINAT FTM 1 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB China) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Switching Mechanism | Pneumatic air-door actuated, static sample placement |
| Preheat Time (RT → 150 °C) | ~30 min |
| Precool Time (RT → −70 °C) | ~85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-stage cascade refrigeration with semi-hermetic German compressors (R404A/R23), water-cooled condenser requiring external 10 m³/h cooling tower |
| Inner Chamber Material | Mirror-finish SUS#304 stainless steel |
| Outer Chamber Material | SUS#304 stainless steel or powder-coated steel |
| Insulation | High-density, fire-retardant PU foam |
| Standard Accessories | One 50 mm diameter cable port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Brand | OK |
|---|---|
| Model | OK-HH-49 / OK-HH-80 / OK-HH-150 / OK-HH-225 |
| Type | Three-Zone (Hot/Cold/Test) or Two-Zone (Hot/Cold with Basket Transfer) Thermal Shock Test Chamber |
| Internal Dimensions (W×H×D, cm) | 40×35×30 to 70×60×60 |
| External Dimensions (W×H×D, cm) | 145×180×140 to 190×170×270 |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Shock Transition Time (Door Switching) | <5 min |
| Hot Zone Preheat Time (RT→150 °C) | ~30 min |
| Cold Zone Precool Time (RT→−70 °C) | ~85 min |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany), R404A/R23 refrigerants |
| Cooling Water Requirement | 10 m³/h external cooling tower (user-supplied) |
| Construction | Interior – mirror-finish SUS#304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Accessories | One φ50 mm cable port |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (Hot Shock) |
| Switching Method | Pneumatic Air-Damper–Actuated Static Specimen Transfer |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-Stage Cascade with Semi-Hermetic German Compressors (R404A/R23) |
| Insulation | High-Density Fire-Retardant PU Foam |
| Interior Material | Mirror-Finish SUS304 Stainless Steel |
| Exterior Material | SUS304 or Powder-Coated Steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (hot shock), 0 °C to −45/−55/−65 °C (cold shock) |
| Switching Mechanism | Pneumatic air-door actuated static sample transfer |
| Recovery Time | ≤5 min |
| Temperature Uniformity | ±2.0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-stage cascade with semi-hermetic compressors (R404A/R23) |
| Internal Construction | Mirror-finish SUS304 stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | TOYO Corporation (Japan) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SR-6517 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EN 367 |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C&W |
| Spray Method | Air-Atomized Nozzle System |
| Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117 & ISO 9227) |
| Nozzle Pressure | 0.7–1.0 bar (regulated) |
| De-misting Method | Compressed Air Blow-Off + Thermal Drying Cycle |
| Temperature Range | Ambient to 50 °C (±0.5 °C uniformity) |
| Humidity Control Range | 10–98% RH (±2% RH accuracy) |
| Chamber Capacities | 100 L, 200 L, 450 L, 750 L |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC9000 |
| Pricing | Upon Request |
| Accuracy | ±5 µm or <2% |
| Scanning Speed | 50 mm/s (with integrated speed-indicating LED) |
| Data Storage | Up to 4 full hull scans (total >10,000 individual measurement points) |
| Interface | USB-to-serial PC interface |
| Power Supply | 4 × AA batteries |
| Compliance | ISO 8502-4, ASTM D3276-05, BS 7079-B4, NACE RP0197 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | DV1300 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 40.2 – 141 KU |
| Speed | 200 rpm |
| Resolution | 0.1 KU |
| Weight | 8.5 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Operating Temperature | +10 °C to +40 °C |
| Protection Rating | IP20 |
| Interface | Unidirectional RS232 |
| Display | 4-line backlit LCD |
| Compliance | ASTM D562, ASTM D1131, ASTM D856 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | DV1400 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 40.2 – 141 KU (Krebs Units) |
| Operating Speeds | 20 rpm and 60 rpm (fixed) |
| Power Supply | Rechargeable battery |
| Weight | 1.8 kg |
| Display | Dual-line backlit LCD |
| Compliance | ASTM D562, ISO 2555, BS 3900-A6, EN ISO 2555 |
| Includes | Rotor set and standard sample cup |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GV Cat |
| Price Range | USD 14,000 – 70,000 |
| Instrument Type | Specialty Tribological Tester for Canned Packaging |
| Max Friction Force | Not Specified |
| Friction Force Resolution | mN |
| Oscillation Frequency | 0–2.5 Hz |
| Stroke Length | 0.5–2 in (12.7–50.8 mm) |
| Test Duration | 0–24 h |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LD8100 / LD8105 |
| Price | Upon Request |
| Voltage Range (LD8100) | 9 V, 90 V |
| Voltage Range (LD8105) | 9 V, 24 V, 67.5 V, 90 V |
| Max Coating Thickness Detection | 500 µm |
| Voltage Accuracy | ±5% |
| Minimum Detectable Resistance | 100 kΩ |
| Feedback Modes | Visual (LCD), Audible (Buzzer), Tactile (Vibration, optional headphone support) |
| Safety Feature | Continuity Check of Return Lead |
| Compliance Standards | ISO 8289-A, ISO 14654:1999, BS 7793-2:1996, ASTM D5162-A, JIS K 6766:2008, TM0384-2002 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LD8100 / LD8105 |
| Price | Upon Request |
| Voltage Range (LD8100) | 9 V, 90 V |
| Voltage Range (LD8105) | 9 V, 24 V, 67.5 V, 90 V |
| Max Coating Thickness | 500 µm |
| Voltage Accuracy | ±5% |
| Detection Sensitivity | 100 kΩ at all voltage settings |
| Feedback Modes | Visual (LCD), Audible (buzzer), Tactile (vibration), Optional Audio (headphone output) |
| Safety Feature | Return-lead continuity monitoring |
| Compliance Standards | ISO 8289-A, ISO 14654:1999, BS 7793-2:1996, ASTM D5162-A, JIS K 6766:2008, TM0384-2002 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LD6057 / LD6058 |
| Pricing | Upon Request |
| Measurement Principles | Magnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous substrates) |
| Display | Monochrome High-Contrast LCD (LD6057) / Reversible Color LCD (LD6058) |
| Data Storage Capacity | 250 readings (LD6057) / 100,000 readings (LD6058) |
| Data Transfer Interfaces | USB (standard), Wi-Fi & Bluetooth (LD6058 only) |
| Compliance Standards | ISO 2808, GOST R 51694 |
| Alarm Function | Audible and visual Hi/Lo limit alert |
| Calibration | Sensor-integrated, auto-recalled per probe |
| Probe Compatibility | Interchangeable modular probes (sold separately) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LD2040 / LD2050 |
| Pricing | Available Upon Request |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | CAT |
| Stroke Length | 12.7–50.8 mm (0.5–2 in) |
| Frequency Range | 0–2.5 Hz |
| Top Cylinder Pressure | 0–6 bar (0–87 psi) |
| Side Cylinder Pressure | 0–6 bar (0–87 psi) |
| Compatible Can Volume | 150–1000 mL |
| Minimum/Maximum Can Diameter | 53–84 mm |
| Minimum/Maximum Can Height | 88–205 mm |
| Operating Temperature | 0–50 °C (32–122 °F) |
| Operating Humidity | 0–90 % RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Air Supply | 8 bar ±20 % |
| Sound Level | <70 dB(A) |
| Weight | 125 kg (276 lb) |
| Dimensions | 1050 × 790 × 760 mm (41.3 × 31.1 × 29.9 in) |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | CoatmasterFlex |
| Measurement Principle | Active Thermographic Optical (ATO) |
| Measurable Substrates | Metal, Rubber, Ceramic, Glass, Plastic, Wood |
| Wet Film Range | 1–400 µm |
| Dry/Powder Film Range | 1–1000 µm |
| Measurement Speed | ≥20 ms per reading |
| Standoff Distance Tolerance | 2–15 cm |
| Angular Tolerance | ±70° |
| Relative Standard Deviation (RSD) | <1% |
| Color Independence | Valid for all colors including white |
| Data Access | Real-time via ERP integration and web browser |
| Weight (without battery) | 1.3 kg |
| Dimensions | 374 × 91 × 203 mm |
| Compliance | DIN EN 15042-2 |
| Brand | TQC Sheen |
|---|---|
| Country of Origin | Netherlands |
| Model | CurveX 4 |
| Dimensions | 110 × 85 × 35 mm |
| Weight | 190 g (6.7 oz) |
| Housing Material | Anodized Aluminum |
| Operating Temperature | 0–60 °C |
| Measurement Range | −200 to 1300 °C |
| Accuracy | ±1 °C (±1.8 °F) |
| Battery Life | Up to 35 h (rechargeable Li-ion via USB-C) |
| Data Storage | 20 batches, 50,000 readings total |
| Sampling Interval | 1 s to 60 min (user-programmable) |
| Channels | 8 thermocouple inputs (Type K standard) |
| Display | Triple-color LED status indicators |
| Interface | USB-C (data export & charging) |
| Compliance | Qualicoat, GSB, ISO 9001, QIB, and ASTM D3003-22 (for thermal profiling in coating cure validation) |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sheen Efflux Cup |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VF2226 / VF2227 / VF2228 / VF2229 / VF2230 |
| Viscosity Range | mPa·s (converted from efflux time in seconds) |
| Orifice Diameter | 2.0 mm (VF2226), 2.7 mm (VF2227), 3.8 mm (VF2228), 4.3 mm (VF2229), 5.3 mm (VF2230) |
| Compliance | ISO 1522:2005, NBN T22-105, BS 3900-E5 |