Plant Physiology & Ecology Instruments
Filter
Showing 301–330 of 578 results
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MULTIPLEX RESEARCH |
| Price | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | N-Pen |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-3 |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 25 mm |
| Origin | Israel |
|---|---|
| Manufacturer | OLAN Ltd. |
| Type | Wireless sensor network-based plant physiology & microclimate monitoring system |
| Model | PM-11z |
| Sensor Capacity | 15 direct + scalable via Router repeaters (15 per repeater) |
| Sampling Intervals | 1–1440 min (configurable) |
| Onboard Storage | SD card (host), 4096 data points per sensor |
| Power | Sensors—3×AA batteries (≥6 months) |
| Compliance | Designed for ISO 17025-aligned field research, GLP-compliant data logging architecture |
| Origin | Israel |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PTM-50 |
| Price Range | USD 68,000 – 136,000 |
| CO₂ Measurement Range | 0–1000 ppm |
| CO₂ Exchange Range | −70 to +70 µmol CO₂·m⁻²·s⁻¹ |
| H₂O Exchange Measurement | Integrated Air Temperature & Relative Humidity Sensor |
| Leaf Chamber Area | 10 cm² |
| Chamber Cycling Time | 20 s |
| Sampling Interval | 5–120 min (user-configurable) |
| Airflow Control | 0.25–0.5 LPM (adaptive) |
| Power Supply | 9–24 VDC |
| Communication | Built-in 2.4 GHz RF Transmitter + USB RF Receiver |
| Operating Temperature | 10–40 °C |
| IP Rating | IP55 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | OTC-Auto |
| Price | USD 42,000 (FOB Beijing) |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PlantPen Portable NDVI Clip-on Sensor |
| Pricing | Available Upon Request |
| Measurement Principle | Dual-wavelength reflectance-based normalized difference vegetation index (NDVI) calculation using built-in 660 nm (red) and 740 nm (NIR) LEDs |
| Spectral Detection Range | 620–750 nm |
| Communication | Bluetooth 1.1, USB 2.0 |
| Onboard Memory | 4 MB flash storage (up to 100,000 measurements) |
| Display | 2×8-character monochrome LCD |
| Keypad | Sealed, waterproof two-button interface |
| Power Supply | 4 × AA rechargeable or alkaline batteries (70 h continuous operation) |
| Auto-power-off | After 5 min inactivity |
| Dimensions | 120 × 57 × 30 mm (4.7″ × 2.2″ × 1.2″) |
| Weight | 180 g |
| Operating Environment | 0–55 °C, 0–95% RH (non-condensing) |
| Storage Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Software Compatibility | Windows-based PC application with real-time control, GPS metadata tagging, Excel export, and remote acquisition support |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PhenoPlot® |
| Pricing | Available Upon Request |
| Brand | EKO-TECH |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PhenoTron-HSI |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PhenoTron-SR |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoTron® |
| Key Features | Integrated LED cultivation, hyperspectral imaging (400–1000 nm), fiber-optic O₂/pH/temperature sensing, chlorophyll fluorescence imaging (FluorCam), thermal infrared (Thermo-RGB), high-throughput 96-well respirometry (REDFLASH), programmable circadian lighting (0–500 µmol·m⁻²·s⁻¹ PAR), morphometric seed & root phenotyping |
| Compliance | Designed for ISO/IEC 17025-aligned lab workflows, supports GLP-compliant data audit trails and FDA 21 CFR Part 11–ready software modules (optional) |
| Brand | EcolabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PhenoTron® Dual-Mode |
| Price | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | PhenoTron® PTS |
| Pricing | Upon Request |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FC 1000-H/GF |
| Pricing | Available Upon Request |
| Illumination Area | 3.5 × 3.5 cm |
| Measuring Light Wavelengths | 620 nm (red), 455 nm (blue) |
| Measuring Light Pulse Duration | 10–250 µs |
| Actinic Light (Blue) | ~350 µmol·m⁻²·s⁻¹ |
| Saturating Pulse (Blue) | up to 1,000 µmol·m⁻²·s⁻¹ |
| Far-Red Light | 735 nm |
| CCD Sensor | 512 × 512 pixels (standard), optional 640 × 480 or 1392 × 1040 |
| Pixel Size | 8.2 × 8.4 µm |
| Spectral Range | 400–1000 nm |
| Quantum Efficiency | 70% at 540 nm, 50% at 400 nm and 650 nm |
| Read Noise | <12 e⁻ RMS (typ. 10 e⁻) |
| Full Well Capacity | >70,000 e⁻ (unbinned) |
| Frame Rate | 50 fps |
| A/D Resolution | 12-bit |
| Power Supply | 90–260 V AC or sealed lead-acid battery |
| System Weight (main unit) | 1.8 kg |
| Tripod Weight | 1.5 kg |
| Power Module Weight | 2.5 kg |
| Total Portable Setup Weight (incl. laptop & accessories) | ~3.5 kg |
| Max Power Consumption | 200 W |
| Communication Interface | USB 2.0 |
| Firmware | Upgradable via BIOS |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | FC800-O |
| Pricing | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FluorPen FP 100 Fixed Transparent Leaf Clip |
| Price | Upon Request |
| Measurement Principle | Modulated Chlorophyll Fluorescence (PAM-based) |
| Time Resolution | 10 µs (100,000 measurements/sec) |
| Fluorescence Detection Range | 697–750 nm |
| Excitation Wavelength | 470 nm (blue LED), optional multi-wavelength LED modules available |
| PAR Sensor Range | 400–700 nm, resolution 1 µmol(photon)·m⁻²·s⁻¹ |
| Data Storage | 4 MB internal memory (≥100,000 data points) |
| Dimensions | 120 × 57 × 30 mm |
| Weight | 180 g |
| Power Supply | 4 × AAA batteries (70 h continuous operation) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Communication | USB or Bluetooth (optional) |
| GPS Module | Optional, time-stamped and georeferenced output |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FluorPen FP 100 Fixed-Leaf-Clip |
| Price | Upon Request |
| Measurement Resolution | 10 µs (100,000 Hz) |
| Fluorescence Detection Range | 697–750 nm |
| Excitation Wavelength | 470 nm (blue LED), optional multi-wavelength modules available |
| PAR Sensor Range | 400–700 nm, resolution ±1 µmol(photon)·m⁻²·s⁻¹ |
| Data Storage Capacity | 4 MB (~100,000 data points) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 4 × AAA batteries (70 h typical runtime) |
| Dimensions | 120 × 57 × 30 mm |
| Weight | 180 g |
| Communication Options | USB or Bluetooth 4.0 |
| GPS Module | Optional, time-stamped georeferenced output |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FluorPen FP 100 |
| Pricing | Upon Request |
| Measurement Principle | Modulated Chlorophyll Fluorescence (PAM-based) |
| Time Resolution | 10 µs (100,000 measurements/sec) |
| Fluorescence Detection Range | 697–750 nm |
| Excitation Wavelength | Standard 470 nm blue LED (optional custom wavelengths available) |
| PAR Sensor Range | 400–700 nm, resolution 1 µmol(photon)·m⁻²·s⁻¹ |
| Saturation Pulse Intensity | 0–3000 µmol(photon)·m⁻²·s⁻¹ |
| Actinic Light Intensity | 0–1000 µmol(photon)·m⁻²·s⁻¹ |
| Data Storage Capacity | 100,000 data points (4 MB internal memory) |
| Dimensions | 120 × 57 × 30 mm |
| Weight | 180 g |
| Power Supply | 4 × AAA batteries (70 h typical operation) |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Communication | USB or Bluetooth (optional) |
| GPS Module | Optional, time-stamped georeferenced output |
| Brand | WALZ |
|---|---|
| Origin | Germany |
| Model | PHYTO-PAM-II |
| Measurement Principle | Pulse-Amplitude-Modulated (PAM) Chlorophyll-a Fluorescence Spectroscopy with Multi-Wavelength Excitation |
| Detection Limit | 0.1 µg/L Chl-a |
| Measurement Light Wavelengths | 440, 480, 540, 590, 625 nm (5-channel pulsed LED) |
| Actinic Light Wavelengths | 440, 480, 540, 590, 625 nm + broadband white (420–640 nm) |
| Far-Red Light | 725 nm LED |
| Signal Detection | H-10720 Photomultiplier Module with >650 nm long-pass filter |
| Max Actinic Irradiance | 1400 µmol·m⁻²·s⁻¹ (continuous), 7000 µmol·m⁻²·s⁻¹ (flash), 5000 µmol·m⁻²·s⁻¹ (saturation pulse) |
| Modulation Frequencies | 8 settings |
| Measurement Light Intensity | 2 levels |
| High-Speed Kinetics Mode | O–I₁ fluorescence rise (ms-scale) enabled |
| Functional Absorption Cross-Section of PSII (σPSII) | Quantifiable via multi-wavelength actinic excitation |
| Reference Spectra Standardization | FluoRed™ calibration protocol for inter-instrument spectral interoperability |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS TreeQinetic |
| Application | Non-destructive in-situ assessment of trunk and root anchorage stability under controlled tensile loading |
| Measurement Principle | Quasi-static mechanical displacement-based biomechanical response analysis |
| Key Components | Wireless elastometer (±2 mm, 0.1 µm resolution), dual-axis inclinometer (±15°, 0.002° resolution), digital forcemeter (0–60 kN, 0.01 kN resolution), overload indicator, Bluetooth-enabled data hub, and proprietary TreeQinetic software suite |
| Compliance | Designed for field use in accordance with DIN EN 1991-1-4 (wind actions), ISO 17225-6 (biomass stability reference frameworks), and GLP-aligned data integrity protocols |
| Power | Rechargeable Li-ion battery pack (10 h typical runtime at 20°C) |
| Wireless Range | Up to 30 m (line-of-sight, Bluetooth 5.0) |
| Mechanical System | Winch assembly rated for 2800 kg pulling force |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS TreeTronic 3 |
| Measurement Principle | Electrical Resistance Tomography |
| Max Electrode Count | 24 |
| Minimum Electrodes Required | 10 |
| Max Output Current | 20 mA |
| Max Output Voltage | 80 V |
| Measurement Modes | Two-point & Three-point |
| Electrode Cable Length | 3.5 m |
| Tree Diameter Range | 3–250 cm (extendable) |
| Onboard Storage | >100 scans |
| Display | Color LCD (real-time ERT visualization) |
| Data Transfer | USB 2.0 / Bluetooth |
| Integrated GPS & Bluetooth | Yes |
| Battery Life | >4 h continuous operation |
| Charging Time | ≤2 h |
| Weight | 8.9 kg |
| Dimensions | 55 × 42 × 13 cm |
| Optional Electronic Dendrometer | Range 160 mm–2150 cm, Stainless Steel Construction, LED Display, Bluetooth Sync |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN~GXY |
| Optical Resolution | 4800 × 9600 dpi |
| Image Acquisition Time | 8 s per scan |
| Sensor | High-Sensitivity CCD |
| Illumination | Uniform LED Array |
| Single-Scan Width | 216 mm |
| Single-Scan Depth | 297 mm |
| Color Depth | 48-bit |
| Scan Chamber Dimensions | Dual-Sided, 280 × 58 × 1000 mm & 280 × 58 × 500 mm |
| Power Supply | External 68,000 mAh Li-ion Battery Pack |
| Integrated Laptop | 13th Gen Intel® Core™ i5-13420H, 15.6" FHD Display, 16 GB DDR5 RAM, 512 GB PCIe NVMe SSD |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PT 100 |
| Price | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PlantPen PRI Meter |
| Price | Upon Request |
| Measurement Principle | Dual-wavelength reflectance ratio at 531 nm and 570 nm |
| PRI Formula | (R₅₃₁ − R₅₇₀) / (R₅₃₁ + R₅₇₀) |
| Spectral Detection Range | 500–600 nm |
| Operating Temperature | 0–55 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Storage Conditions | −10 to 60 °C, 0–95 % RH (non-condensing) |
| Communication | Bluetooth 1.1, USB 2.0 |
| Internal Memory | 4 MB (up to 100,000 measurements) |
| Display | 2×8-character monochrome LCD |
| Keypad | Sealed, waterproof two-button interface |
| Power Supply | 4 × AA rechargeable or alkaline batteries (70 h continuous operation) |
| Auto-power-off | After 5 min idle |
| Dimensions | 120 × 57 × 30 mm (4.7″ × 2.2″ × 1.2″) |
| Weight | 180 g |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen Conveyor-Belt |
| Imaging Area | 35 × 35 cm |
| Conveyor Length | 400 cm |
| Positioning Accuracy | ±0.1 mm |
| Scan Speed | up to 150 mm/s |
| Fluorescence Imaging | Modulated Red LED (620 nm), Far-Red LED (735 nm), Dual-Color Actinic Light (Red + Blue / Red + Cool White) |
| CCD Options | 720 × 560 @ 50 fps (GFP-compatible) or 1360 × 1024 @ 20 fps |
| Fluorescence Parameters | Fo, Fo′, Fs, Fm, Fm′, Fv, NPQ, QY, Rfd, and >50 derived metrics |
| RGB Sensor | 2560 × 1920, 1/2.5″ CMOS, 2.2 µm pixel size |
| Thermal Imaging (optional) | 640 × 480, NETD < 0.05 °C @ 30 °C, 20–120 °C range |
| Software | PSI PhenotypeDB™ with automated protocol scheduling, GLP-compliant audit trail, remote web access, role-based user permissions, and real-time data visualization |
| Brand | PSI (Photosynthesis Systems, Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PlantScreen RGB |
| Imaging Area | 1500 × 3225 px (X×Y) |
| Max Plant Height | 1250 px |
| Z-Axis Load Capacity | 30 kg |
| Fluorescence Camera | 1392 × 1040 px, 35 × 875 px FOV |
| RGB Camera | 2560 × 1920 px, CMOS 1/2", 2.2 µm pixel size |
| Excitation Wavelengths | 618 nm (measuring light), dual-wavelength (orange + white) actinic light, white saturating flash (up to 3600 µmol/m²/s), 735 nm NIR |
| Fluorescence Parameters | Fo, Fm, Fv, Fo’, Fm’, Fv’, Ft, Fv/Fm, Fv’/Fm’, ΦPSII, NPQ, qN, qP, Rfd, etc. |
| RGB Morphometric Parameters | Leaf Area, Solidity, Perimeter, Eccentricity, Roundness, Medium Leaf Width Index, Slenderness of Leaves (SOL), Circle Diameter, Convex Hull Area, Centroid, Internodal Distance, Growth Height, 3D Max Height/Width, Relative Growth Rate, Leaf Angle, Node Leaf Count, Greening Index, Color Segmentation Metrics |
| Motion Control | X/Y/Z axes with ±1 mm (X/Y), ±5 mm (Z) positioning accuracy |
| Power Supply | 3×230/220 VAC, 50/60 Hz |
| Dimensions | 5000 × 3750 × 230 px (L×W×H) |
| Weight | ~400 kg |
| Origin | Israel |
|---|---|
| Type | Imported Instrument |
| Manufacturer Role | Authorized Distributor |
| Model | PM-11z |
| Pricing | Available Upon Request |
| [Origin | Israel |
|---|---|
| Type | Imported |
| Manufacturer Role | Authorized Distributor |
| Model | PM-11z |
| Pricing | Available Upon Request] |
| Brand | PM-Tech |
|---|---|
| Origin | Germany |
| Model | RTC-V17 |
| Camera Resolution | 17.8 MP RGB |
| Imaging Area | 55 mm (W) × 40 mm (H) |
| Light Sources | White, Red, Green, UV (software-controlled intensity) |
| Power Supply | 5 V DC via USB |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Image Acquisition Time | <1 s |
| Integrated Sensors | 12-bit temperature sensor (−50 to +85 °C), water immersion detection with auto-shutdown |
| Software Modes | Pregizer / Topology / Custom topology |
| Data Export | CSV, Excel-compatible formats |
| Language Support | English, Simplified Chinese, Traditional Chinese |
| Brand | PMS |
|---|---|
| Origin | USA |
| Model | 1515D |
| Measurement Range | 0–100 bar |
| Accuracy | ±1% of reading (at 50 bar, half-scale) |
| Chamber Material | Stainless Steel |
| Chamber Internal Dimensions | 6.35 cm ID × 12.7 cm depth |
| Display | Digital backlit pressure gauge with selectable units (bar, MPa, psi) |
| Gas Supply | Integrated 20 ft³ aluminum nitrogen cylinder (max pressure 207 bar) |
| Weight | ~16 kg (instrument only) |
| cylinder | 3.9 kg |
| Overall Dimensions | 56 × 38 × 26 cm |
| Seal Options | Standard 6.35 mm compression seal |
| Accessories | 7× and 3.5× magnifying eyepieces (AAA-powered), LED-illuminated 10× handheld eyepiece, gas-saver valve (full- or half-range), sample insertion tools (1/8", 3/16", 1/4" OD), reusable moisture-equilibration sample bags (species-specific sizing), stainless steel chamber base caps (9.525 mm, 12.7 mm, grass-leaf) |