Spectroscopy Instruments
Filter
Showing 1681–1710 of 2629 results
| Brand | Redback Systems |
|---|---|
| Origin | Australia |
| Model | RS40k |
| Spectral Range | 430–950 nm |
| Resolution (R = λ/Δλ) | 44,000–32,000 |
| Wavelength Stability | <5 pm/°C |
| Wavelength Accuracy | <20 pm |
| Input Interface | Single-mode fiber, FC/PC |
| Detector | Cooled sCMOS (Sony STARVIS) |
| Exposure Time | 1–20,000 ms |
| Dark Current | 0.2 e⁻/pixel/s |
| Read Noise | 1.9 e⁻/pixel (rms) |
| Data Acquisition Rate | up to 5 Hz |
| Dimensions (H×W×L) | 105 × 320 × 292 mm |
| Brand | RELION |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | RELION CL-MicroSpectra |
| Operating Principle | Electron Beam–Induced Cathodoluminescence Spectroscopy |
| Imaging Modality | Computerized Tomographic Spectral Mapping |
| Platform Compatibility | Ground-Based & Airborne Integration |
| Spectral Range | 200–850 nm (CL Emission), Extended to 1–10,000 µm² spatial sampling area |
| Spectral Resolution | 1–15 nm (FWHM) |
| Spatial Resolution (IFOV) | 1 nm (at optimal beam focus) |
| Field of View (TFOV) | 8 mm diameter |
| Imaging Frame Rate | 15 fps (full-frame spectral cube acquisition) |
| Vacuum Chamber | ≤0.25 Pa base pressure |
| Electron Gun | Cold Cathode, Horizontal Geometry |
| Acceleration Voltage | 0–30 kV (adjustable in 100 V increments |
| Beam Current | 0.15–1 mA continuous (5 mA peak, current-limited with thermal feedback) |
| Spot Size Control | Variable demagnification from defocused (≥5 µm) to diffraction-limited point focus (<10 nm at 25 kV) |
| Digital Interface | Real-time vacuum, HV, beam current, and operational mode display with status logging |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPSE-A |
| Pricing | Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | ≥10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Wavelength Range (Monochromator) | 300–800 nm (standard), optional 200–800 nm |
| Spectral Resolution | 4.32 nm (adjustable via slit pairs: 0.4–7.2 nm, slit widths 0.05–1.0 mm) |
| Wavelength Accuracy | ±0.2% |
| Wavelength Repeatability | ±0.15% |
| Monochromator Scan Speed | 50 nm/s (standard), 100 nm/s (high-speed) |
| Exit Slit Width | 600 µm |
| Scan Modes | Time-based, fixed-point, range-scan, cyclic scan |
| Photodetector Wavelength Range | 230–700 nm |
| Peak Sensitivity Wavelength | 420 nm |
| Detection Method | Single-Photon Counting |
| Integration Times | 1 ms to 3600 s (12 selectable steps) |
| Brand | IVEA |
|---|---|
| Origin | France |
| Instrument Type | Online LIBS System |
| Laser Source | Pulsed Nd:YAG (266 nm / 355 nm / 532 nm options) |
| Operating Distance | 3–10 m (customizable) |
| Probe Options | FarLIBS (telescopic coupling) or OfiLIBS (fiber-optic coupling) |
| Optical Architecture | Integrated collimation, focusing, and light collection path |
| Spectrometer Options | Echelle spectrometer + ICCD or Czerny-Turner spectrometer + ICCD |
| Motion Control | Motorized XYZ sample positioning stage |
| Integration | Modular, field-deployable design |
| Compliance | Designed for industrial process monitoring and hazardous environment deployment |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Basis |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Qontor |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Raman-AFM |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Coupling Architecture | Modular optical bridge for direct integration with third-party AFM/SPM platforms (e.g., Bruker Nano Surfaces, Nanonics, NT-MDT, JPK, Park Systems) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Raman-SCA-SEM |
| Instrument Type | Confocal Micro-Raman Spectrometer Integrated with Scanning Electron Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia Reflex |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ≤0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia-Reflex |
| Laser Excitation Options | UV–NIR (e.g., 244 nm, 325 nm, 488 nm, 532 nm, 633 nm, 785 nm) |
| Spectral Range | Down to <10 cm⁻¹ (with NExT filter) |
| Spatial Resolution | <1 µm (lateral), sub-micron axial (confocal) |
| Detector | RenCam™ deep-depletion CCD (UV–NIR enhanced, ultra-low noise) |
| Software | WiRE™ 2.0 (21 CFR Part 11 compliant, scriptable, database-integrated) |
| Microscope Platform | Leica research-grade upright microscope |
| Automation Level | Full motorized laser switching, auto-alignment, auto-focus, auto-confocal mode selection, real-time optical feedback calibration |
| Safety Class | Class 1 (fully enclosed beam path, interlocked access) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | inVia™ InSpect |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | XY ≈ 1 µm, Z ≈ 2 µm |
| Low-Wavenumber Capability | down to 10 cm⁻¹ |
| Spectral Reproducibility | < ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA802 |
| Instrument Type | Confocal Micro-Raman Imaging System |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RA816 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Virsa Raman Analyzer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 50–4000 cm⁻¹ |
| Spectral Resolution | <2.5 cm⁻¹ |
| Spatial Resolution | XY <0.5 µm, Z <2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EUV-X-L Flow Lamp |
| Beam Geometry | Single-Beam Configuration |
| Detector Type | CCD-Based Photoreceiver |
| Wavelength Range | 24–800 nm |
| Wavelength Selection | Manual (via External Monochromator Integration) |
| Spectral Bandwidth | <30 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Photon Flux | >1×10¹⁵ photons/sec/ster at primary EUV emission lines |
| Mass | <1 mg (lightweight integrated lamp head) |
| EUV Emission Capability | Extended output below 25 nm |
| Brand | Resolution Spectra Systems |
|---|---|
| Origin | France |
| Model | MICRO Spectra |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 630–1070 nm |
| Spectral Resolution | 0.01 nm (FWHM) |
| Spatial Resolution | 0.01 nm |
| Minimum Wavenumber Accuracy | 0.01 nm |
| Spectral Repeatability | ±0.01 nm |
| Calibration Stability | Drift-free over time and temperature |
| Technology | SWIFTS™ (Stationary Wave Interferometer Fourier Transform Spectrometer) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VS-7550 |
| Price Range | USD 1,400–2,800 (FOB) |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 104 nm – 1030 nm |
| Automation | Motorized Wavelength Scanning |
| Spectral Bandwidth | Not Applicable (Fixed-grating, slit-defined resolution) |
| Wavelength Accuracy | ±0.35 nm |
| Stray Light | ≤0.01% T |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VS7550 |
| Price Range | USD 0–4,999 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 104 nm – 1030 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | Not Applicable (Fixed by Grating & Slit) |
| Wavelength Accuracy | ±0.35 nm |
| Stray Light | ≤0.01% T |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Resonon Bio-LIF Hyperspectral Fluorescence Imaging System |
| Price Range | USD 1,500–1,500,000 (FOB) |
| Spectral Resolution (FWHM) | 1.9 nm |
| Excitation Wavelength | 532 nm |
| Emission Range | 550–1000 nm |
| Spatial Resolution | 60 µm/pixel |
| Image Dimensions | 1600 × 2065 pixels |
| Spectral Bands per Pixel | 335 |
| Scan Time | 25 s |
| SNR (max) | 255 |
| Weight | 28 kg |
| Dimensions | 50 × 70 × 28 cm |
| Power Supply | 120/240 VAC |
| Operating Temperature | +10 to +35 °C |
| Sample Compatibility | 90 mm Ø Petri dishes or standard 96-well microplates (127 × 86 mm) |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika II |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment | Ground-based & Airborne |
| Spectral Range | 400–900 nm |
| Spectral Resolution | 2.1 nm |
| Spatial Channels | 640 |
| Spectral Channels | 240 |
| Frame Rate | 145 fps |
| Field of View (TFOV) | 3.9°, 5.5°, 12.0°, 16.0°, 22.5°, 33.0°, or 43.5° (interchangeable optics) |
| Instantaneous Field of View (IFOV) | 0.20, 0.30, 0.65, 0.88, 1.25, 1.9, or 2.5 mrad (optics-dependent) |
| Bit Depth | 12-bit |
| Interface | IEEE 1394b & Gigabit Ethernet |
| Power | 8–30 VDC, <2.5 W |
| Weight | 1.3 kg |
| Dimensions | 124 × 239 × 210 mm |
| Operating Temperature | 0–45 °C |
| Aperture | f/3.0 |
| RMS Spot Radius (avg.) | 7 µm |
| Smile (peak-to-peak) | 5 µm |
| Keystone (peak-to-peak) | 7 µm |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 4.9 nm |
| Spectral Bands | 164 |
| Spatial Pixels per Line | 320 |
| Max Frame Rate | 520 fps |
| Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | Gigabit Ethernet |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 30 µm |
| Average RMS Spot Radius | 10 µm |
| Smile (Peak-to-Peak) | 10 µm |
| Keystone (Peak-to-Peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR+ |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 2.5 nm |
| Spectral Bands | 328 |
| Spatial Pixels | 640 |
| Max Frame Rate | 249 fps |
| Data Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | GigE Vision |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 15 µm |
| RMS Spot Radius (avg.) | 10 µm |
| Smile (peak-to-peak) | 10 µm |
| Keystone (peak-to-peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika L |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.1 nm |
| Spatial Resolution (IFOV) | 0.2–0.65 mrad (configurable) |
| Field of View (TFOV) | 3.9°, 5.5°, or 12.0° (selectable) |
| Frame Rate | 249 fps |
| Spatial Pixels per Line | 900 |
| Spectral Bands | 281 |
| Bit Depth | 12-bit |
| Weight | 0.6 kg |
| Dimensions | 10.0 × 12.5 × 5.3 cm |
| Aperture | f/2.4 |
| Pixel Size | 5.86 µm |
| RMS Spot Radius (avg.) | 6 µm |
| Smile (peak-to-peak) | 4 µm |
| Keystone (peak-to-peak) | 5 µm |
| Interface | USB 3.0 |
| Operating Temperature | 5–40 °C |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika NIR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 4.9 nm |
| Spatial Channels | 3200 |
| Field of View (TFOV) | 7.3°, 11°, 22°, or 90° (selectable) |
| Instantaneous Field of View (IFOV) | 0.4, 0.6, 1.2, or 6.3 mrad |
| Frame Rate | 520 fps |
| Spectral Bands | 164 |
| Bit Depth | 14-bit |
| Interface | GigE Vision |
| Weight | 2.7 kg |
| Dimensions | 11.0 × 29.6 × 8.9 cm |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| RMS Spot Radius (avg.) | 10 µm |
| Smile (peak-to-peak) | 10 µm |
| Keystone (peak-to-peak) | 10 µm |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PIKA SWIR |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution (FWHM) | 11.0 nm |
| Spatial Pixels | 640 |
| Spectral Bands | 245 |
| Platform Compatibility | Ground-based and Airborne Deployment |
| Pricing | Available Upon Request |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika UV |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 350–800 nm |
| Spectral Resolution | 2.3 nm |
| Spatial Channels | 1600 |
| Spectral Channels | 196 |
| Field of View (TFOV) | 29.0° |
| Instantaneous Field of View (IFOV) | ≤1600 × n (n = scan lines) |
| Frame Rate | 165 fps |
| Bit Depth | 12-bit |
| Weight | 2.1 kg |
| Dimensions | 10.0 × 26.4 × 7.4 cm |
| Interface | USB 3.0 |
| Operating Temperature | 5–40 °C |
| Aperture | f/2.4 |
| Pixel Size | 8 µm |
| RMS Spot Radius (avg.) | 8 µm |
| Smile (peak-to-peak) | 4 µm |
| Keystone (peak-to-peak) | 6 µm |
| SNR | >600:1 (typ. @ full well) |
| Stray Light Rejection | <0.05% |
| Distortion | <0.1% radial |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika XC |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.4 nm |
| Spatial Pixels | 1384 |
| Frame Rate | 240 fps |
| Field of View (TFOV) | 7.2°, 10.0°, 21.5°, 29.0°, 40.0°, 57.5°, or 72.0° (selectable) |
| Instantaneous Field of View (IFOV) | 0.36, 0.5, 1.1, 1.5, 2.1, 3.1, or 4.2 mrad (selectable) |
| Bit Depth | 14-bit |
| Power Requirement | 8–30 VDC, <2.5 W |
| Weight | 1.9 kg |
| Dimensions | 12.4 × 23.9 × 21.0 cm |
| Operating Temperature | 0–45 °C |
| f-number | f/2.4 |
| RMS Spot Radius (avg.) | 6 µm |
| Smile (peak-to-peak) | 2 µm |
| Keystone (peak-to-peak) | 6 µm |
| Interface | IEEE 1394b |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika XC2 |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based & Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 1.3 nm |
| Spatial Resolution (IFOV) | 0.36–1.1 mrad (configurable) |
| Field of View (TFOV) | 7.2°, 10.0°, or 21.5° (interchangeable optics) |
| Maximum Frame Rate | 171 fps |
| Spatial Pixels per Line | 1600 |
| Spectral Bands | 447 |
| Bit Depth | 12-bit |
| Weight | 2.2 kg |
| Dimensions | 10.1 × 27.5 × 7.4 cm |
| Aperture | f/2.4 |
| Pixel Size | 5.86 µm |
| RMS Spot Radius (avg.) | 6 µm |
| Smile (peak-to-peak) | 4 µm |
| Keystone (peak-to-peak) | 5 µm |
| Interface | USB 3.0 |
| Operating Temperature | 5–40 °C |
| Software Support | Native Windows & Linux drivers |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RFFS-1 |
| Price | Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | RM405 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 400 cm⁻¹ to 4500 cm⁻¹ |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | ±≤0.15 cm⁻¹ |