| Brand | Coatema |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Coatema Prepreg Line |
| Pricing | Upon Request |
| Brand | PSA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickSlit |
| Pricing | Upon Request |
| Max Web Width | 2200 mm |
| Max Unwind Roll Weight | 3000 kg |
| Max Unwind Diameter | Φ1600 mm |
| Core Diameter Range | Φ50–200 mm |
| Slitting Methods | Guillotine, Score, Flying Cut, Pressure Cut, Tear Cut |
| Min Slit Width | 20 mm |
| Max Rewind Diameter | Φ600 mm |
| Max Line Speed | 800 m/min |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 79-11-00 |
| Force Range | 0–399 gf |
| Display | 3-digit LCD |
| Crease Angle | 90° |
| Bend Angle (Stiffness) | 15° |
| Readout Time | 15 s |
| Resolution & Accuracy | ±1.0 gf |
| Power Supply | 240 V, 50 Hz |
| Fuse | 500 mA |
| Dimensions (Instrument) | 235 mm (H) × 180 mm (L) × 320 mm (W) |
| Dimensions (Packed) | 670 mm (H) × 550 mm (L) × 520 mm (W) |
| Weight (Instrument) | 11 kg |
| Weight (Packed) | 14 kg |
| Includes | Precision cutting blade and certified calibration weights |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Model | Rheo-Line MFR |
| Compliance | ASTM D5289, ASTM D6204, ASTM D6601 |
| Cavity Type | Dual-cone, fully sealed |
| Cavity Gap | 0.45 mm (nominal) |
| Torque Measurement | Top platen-mounted torque transducer |
| Closure System | Flexible closure mechanism to prevent film rupture and sample distortion |
| Temperature Control | 3-zone PID, ±0.03 °C accuracy |
| Drive System | High-performance servo motor with aerospace-grade digital servo controller |
| Frequency Range | 0.01–40 Hz |
| Strain Amplitude Range | 1%–200% |
| Torque Calibration | Precision torque spring |
| Power Supply | 220 V AC, 50 Hz, single-phase |
| Pneumatic Requirement | 4.2 kg/cm² (60 psi) |
| Torque Units | in·lb or N·m (user-selectable) |
| Temperature Units | °C / °F |
| Pressure Units | psi / kg/cm² (configurable) |
| Time Format | min/sec, min/decimal, sec |
| Data Export | Universal ASCII/CSV format compatible with SQL, LabVIEW, MATLAB, and LIMS platforms |
| Host PC Requirements | Pentium-class processor, Ethernet interface |
| Optional Accessories | Automated sample loader, volumetric sample cutter |
| Brand | Duratt |
|---|---|
| Origin | Shanghai, China |
| Model | D8000 / D10000 / D12000 |
| Max Dynamic Force | 12000 N |
| Frequency Range | 0.01–100 Hz |
| Dynamic Displacement | ±30 mm |
| Host Weight | 200 kg |
| Compliance | CE-certified electrical design |
| Actuation | Custom high-performance linear motor with integrated ball-screw vertical positioning |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Model | TC-micro |
| Configuration Options | TC50 (2ר50 mm or 4ר32 mm) / TC63 (2ר63 mm or 4ר32 mm) |
| Pressure Control | Constant-pressure hydraulic circuit |
| Thermal Range | 5–95 °C (adjustable setpoints) |
| Water Reservoirs | Dual 500 L pressurized tanks (hot & cold) |
| Flow Monitoring | Integrated inline flow sensors per test channel |
| Minimum Flow Velocity | ≥0.5 m/s (automatically maintained) |
| Test Chamber Architecture | Four independent, sealed micro-chambers with individual leak detection |
| Control Interface | 15-inch industrial touchscreen HMI with PLC-based logic |
| Safety Compliance | EN 61000-6-2/6-4, EN ISO 13857, integrated emergency stop circuits |
| Brand | BDC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Medical Device Testing Equipment |
| Model | VDT3600i |
| Instrument Type | Cardiovascular Implant Fatigue Tester |
| Maximum Test Pressure | 500 mmHg |
| Frequency Range | 3–50 Hz |
| Unit Weight | 160 kg |
| Brand | PSA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ShortSlit Auto |
| Quotation | Upon Request |
| Max Web Width | 3600 mm |
| Max Parent Roll Weight | 4000 kg |
| Max Material Thickness | 2000 µm |
| Core Diameter Range | 1"–6" (paper, plastic, or coreless) |
| Slitting Methods | Rotary Shear, Score Slitting, Crush Cut |
| Min Slit Width | 200 mm |
| Max Rewind Diameter | Φ500 mm |
| Max Line Speed | 400 m/min |
| Cycle Time | e.g., 50 m rewound in ≤25 s |
| Brand | PSA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SuperSlit |
| Pricing | Available Upon Request |
| Maximum Web Width | 800–4000 mm |
| Max Unwind Roll Weight | 5000 kg |
| Max Unwind Diameter | Φ1800 mm |
| Core Diameter Range | Φ50–200 mm |
| Slitting Methods | Guillotine, Score, Flying Cut, Pressure Cut, Tear Cut |
| Minimum Slit Width (with shaft-mounted winders) | 25 mm |
| Minimum Slit Width (with independent turret winders) | 240 mm |
| Max Rewind Diameter | Φ1500 mm |
| Max Line Speed | 800 m/min |
| Compatible Materials | Industrial Films, Packaging Films, Coated Flexible & Rigid Films, Paper, Laminates, Aluminum Foil Composites, Nonwovens, Multilayer Composites |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/61 |
| Test Chambers | 6 × 10 cm² |
| Sample Types | Films & Rigid/ Flexible Packages (up to 3 L) |
| OTR Range (per chamber) | 0.5–1000 cm³/m²·day |
| Combined 6-chamber range | 0.1–200 cm³/m²·day |
| RH Control | 0–90% RH (film), 100% RH on O₂ side only |
| Temperature Range | Ambient to 65°C |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Test Range (Film) | 0.05–200 cc/(m²·day) |
| Resolution | 0.02 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1% |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Testing Capacity | Up to 3 L |
| Sensor Type | Coulometric (Coulox®) |
| Compliance | ASTM D3985, ISO 15105-2, YBB 00082003, GB/T 1038 |
| Interface | Touchscreen + USB + Ethernet |
| Optional | PermNet® Lite software, Package Test Conversion Chamber |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sciteq HCP |
| Pricing | Upon Request |
| Brand | PROSIM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1 |
| Quotation | Upon Request |
| Instrument Type | Multiaxial Orthopedic Fatigue Tester |
| Maximum Test Load | 5 kN |
| Frequency Range | >2.0 Hz |
| Machine Weight | 400 kg |
| Brand | IIC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XLDS-15 |
| Pricing | Available Upon Request |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | PS-800C |
| Application Scope | Polyolefin resin pellets (transparent & semi-transparent) |
| Throughput | Up to 1,000 kg/h |
| Detection Principle | Dual 3-CCD color line-scan imaging under free-fall conditions |
| Output Functions | Contamination identification, particle rejection triggering, color-ratio quantification |
| Compliance Context | Designed for GLP-aligned QC environments |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Fully Automatic Hydraulic Pellet Press |
| Max Platen Pressure | 50 MT |
| Platen Dimensions | 300 × 300 mm |
| Max Opening Distance | 150 mm |
| Overall Dimensions (L×W×H) | 120 × 70 × 176 cm |
| Net Weight | 950 kg |
| Heating Power | 2 × 5 kW |
| Hydraulic Motor Power | 4.0 kW |
| Max Platen Temperature | 300 °C |
| Programmable Cooling Rate | 0–20 °C/min (controlled from 0 °C to 200 °C) |
| Brand | PROSIM |
|---|---|
| Origin | United Kingdom |
| Model | HIP-SPINE-FATIGUE-SIMULATOR |
| Max Test Load | 5 kN |
| Frequency Range | 2.0 Hz |
| Machine Weight | 800 kg |
| Degrees of Freedom | 6-axis motion per station (flexion/extension ±60°, abduction/adduction ±20°, internal/external rotation ±30°) |
| Microseparation Capability | up to 5 mm (acetabular cup) |
| Temperature Control | 37 °C ± 2 °C (serum bath) |
| Station Capacity | 6 simultaneous implant test stations + 2 load-soak stations |
| Sensor Configuration | Six-axis load cell per station |
| Motion Control | Closed-loop servo-electromechanical actuation with waveform tracking fidelity < ±0.5% error |
| Compliance | ISO 14242-1:2012, ISO 18192-1:2011 |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 22-34 |
| Cutting Width | 15 mm |
| Cutting Length | 254 mm |
| Dimensional Accuracy | ±0.05 mm |
| Construction | Hardened Steel Blade Assembly with Integrated Safety Guard |
| Brand | Duratt |
|---|---|
| Origin | Shanghai, China |
| Model | D200 / D500 / D1500 / D3000 |
| Max Test Force | 3000 N |
| Frequency Range | 200 Hz |
| Dynamic Displacement | ±30 mm |
| Host Weight | 200 kg |
| Compliance | CE |
| Brand | Labtech Engineering |
|---|---|
| Origin | Sweden |
| Model | LEP 20-6 |
| Screw Diameter | 20 mm |
| Target Tubing ID Range | 4–6 mm (customizable) |
| Vacuum Sizing & Cooling Tank | Integrated |
| Haul-off System | Belt-driven, variable-speed |
| Winder | Stepless-speed, tension-controlled |
| Optional | Laser-based diameter measurement system |
| Multi-layer Co-extrusion Capability | Yes |
| Compliance | Designed for ISO 13485-aligned R&D environments and ASTM D2136/D3835-compliant polymer processing validation |
| Brand | TMI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 75-50 |
| Price | Upon Request |
| Heat Seal Temperature Range | Ambient to 350°C (662°F) |
| Temperature Resolution | ±0.1°C (0.18°F) |
| Temperature Accuracy | ±0.70°C (1.26°F) |
| Hot Tack Load Cell Capacity | 111.2 N (11.3 kgf) |
| Load Accuracy | 0.1% Full Scale |
| Peel Speed Range | 1–200 mm/sec (0.04–7.87 in/sec) |
| Seal Load Cell Capacity | 4448.2 N (453.6 kgf) |
| Load Accuracy | ±0.89 N (±0.09 kgf) |
| Seal Pressure Range | 137.9–2758 kPa (20–400 psi) |
| Pressure Resolution | 0.68 kPa (0.1 psi) |
| Seal Delay Time Range | 0.20–99.99 s |
| Time Resolution | 10 ms |
| Control Timing Accuracy | ±0.025 ms |
| Seal Jaw Length | Up to 203.2 mm (8.0 in) |
| Jaw Width | 12.7–25.4 mm (0.5–1.0 in) |
| Jaw Surface Configurations | Flat, Vertical, Horizontal, Custom, or Standard Geometries |
| Compliance | ASTM F1921, ASTM F2029, ASTM F88, ISO 11607-2, USP <1207> |
| Calibration Standard | ASTM E4 |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | OP5 |
| Compliance | ASTM D1238, ISO 1133 |
| Accuracy | ±0.5% |
| Calibration | Fully automated, zero manual calibration required |
| Sampling | Continuous micro-sampling (≈20 g per cycle) |
| Maintenance | Single-gear-pump architecture |
| Installation | Process-integrated, non-intrusive inline configuration |
| Application Domain | Polyolefins, polyethylene (PE), polypropylene (PP), thermoplastic elastomers (TPE), engineering plastics |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mooney-Line |
| Pricing | Upon Request |
| Standard Compliance | ISO 289 |
| Power Supply | Single-phase AC 220 V, 50 Hz |
| Compressed Air Requirement | 4.2 kg/cm² (60 psi) |
| Rotor Speed | 2 rpm |
| Temperature Control | Digital PID |
| Temperature Range | Ambient to 200 °C |
| Measuring Units | Mooney units (MU) for viscosity |
| Test Modes | Mooney viscosity [ML(1+X)], scorch time (ts1, ts2), compound scorch & viscosity profiling, stress relaxation, die release test |
| Preheat Option | Enabled / Disabled per test protocol |
| Data Storage | Microsoft Access or SQL Server database (exportable) |
| Host PC Requirements | Pentium-class CPU, Ethernet interface, Windows 2000 or XP |
| Optional Accessories | Small rotor, large rotor, volumetric sample cutter |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported |
| Model | LF-600 |
| Screw Options | 12.5 mm, 20 mm, 25 mm, 30 mm, 45 mm |
| Max Layflat Width | 1000 mm |
| Max Layers | 11 |
| Winding | Dual-station air-expanding shaft (coreless) |
| Tower Height | Adjustable |
| Cooling Ring | High-efficiency annular air ring |
| Die Type | High-performance spiral mandrel die |
| Form Factor | Benchtop to floor-standing configurations available |
Show next