Volatile Organic Compounds Detector
Filter
Showing 61–90 of 184 results
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer | IONICON Analytik GmbH |
| Model | FUSION PTR-TOF 10k |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Source VOC Monitoring System |
| Detection Range | 100 ppqv – 100 ppb |
| Mass Resolution | ≥10,000–15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% of reading (mass axis calibration stability) |
| Response Time | ≤100 ms (90% signal rise time, T90) |
| Limit of Detection | <0.1 pptv (for selected VOCs, e.g., benzene, isoprene) |
| Sensitivity | up to 30,000 cps/ppbv (H₃O⁺ mode, for monoterpenes) |
| Brand | IONICON Analytik G.m.b.H. |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 1000 |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Analyzer |
| Typical Configuration | Integrated VOC Monitoring System |
| Detection Range | 10 pptv – 1 ppmv |
| Resolution | 1 pptv |
| Accuracy | ±10 pptv |
| Response Time | ≤100 ms |
| Mass Range | 1–10,000 Th |
| Mass Resolving Power | >1500 (m/Δm) |
| Sampling Flow Rate | 50–800 sccm |
| Inlet & Reaction Chamber Heating | 40–180 °C and 40–120 °C respectively |
| Power Supply | 100–230 V AC, max. 1000 W |
| Dimensions (W×H×D) | 60 × 91 × 80 cm |
| Weight | 150 kg |
| Data Interfaces | Ethernet, RS232 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR-TOF 10K |
| Detection Principle | Proton-Transfer-Reaction (PTR) Ionization |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Gas-Stream VOC Analyzer |
| Detection Range | 1 pptv – 100 ppbv |
| Mass Resolution (m/Δm) | ≥10,000–15,000 |
| Accuracy | ±0.001% (relative mass accuracy) |
| Response Time | ≤100 ms |
| Detection Limit | <1 pptv |
| Sensitivity | >1000 cps/ppbv |
| Brand | IONICON Analytik G m.b.H. |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR-TOF QB |
| Detection Principle | Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOF MS) |
| Instrument Type | Portable |
| Typical Configuration | Multi-Analyte VOC Analyzer |
| Detection Range | C2–C12 Volatile Organic Compounds (VOCs), including aldehydes, ketones, aromatics, terpenes, oxygenates, and sulfur-containing compounds |
| Mass Resolution (m/Δm) | 4000 (FWHM at m/z 200) |
| Accuracy | ±5% relative to certified standard gas mixtures |
| Response Time | <100 ms (10–90% rise time for individual compounds) |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | PTR3-TOF 10K |
| Detection Principle | Proton Transfer Reaction (PTR) coupled with High-Resolution Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Real-Time Gas Analyzer |
| Configuration | Single-Stream Ambient Air Monitoring System |
| Detection Range | 0.1 pptv – 100 ppbv |
| Mass Resolution | Up to 15,000 m/Δm (FWHM) |
| Accuracy | ±0.001% mass accuracy (calibrated) |
| Response Time | < 100 ms (10–90% step response) |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Emission Monitoring (CEM) Analyzer |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Measurement Range | 0–100,000 ppm (as propane or methane equivalent) |
| Resolution | 100 ppb |
| Accuracy | ±5% of reading |
| Response Time (T90) | <1 s |
| Operating Temperature of Sample Path & Detectors | 190 °C |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Purge Gas | Compressed Air or Nitrogen |
| Integrated Combustion Air Supply | Yes |
| Sample Pump | Integrated |
| Zero/Calibration Gas Management | Overload Protection with Automatic Calibration Sequence |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-OVE |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC (TVOC) Monitoring System |
| Measurement Range | 0–1000 ppm (as propane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109L |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC / THC / NMHC / CH₄ Analyzer |
| Measurement Range | 0–1000 ppm (selectable up to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Heating Chamber Temperature | 190 °C |
| Detector Sensitivity | ≤1 ppm full-scale for CH₄ |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15FID |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Detection Range | 0–10,000 ppm C₁–C₁₀ (as methane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±0.1 ppm (at low end), ±1% FS (full scale) |
| Response Time (T₉₀) | ≤3 s at 15 mL/min sample flow |
| Sample Flow Rate | Adjustable 10–30 mL/min (600–1,800 L/h) |
| Heating Zone Temperature | 180 °C (uniform, thermostatically controlled) |
| Integrated Combustion Air Supply | Yes (built-in compressor, no external air source required) |
| Brand | CHINYEE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3-200-3 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Detection Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Operating Heater Temperature | 190 °C |
| Sensitivity (CH₄) | ≤1 ppm full-scale |
| Carrier/Combustion Air | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200-a |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Sensitivity (CH₄) | 1 ppm full-scale |
| Flow Stability | Precision back-pressure regulation |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-300A |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Detection Range | 0–1000 ppm (expandable to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Operating Heater Temperature | 190 °C |
| Carrier/Combustion Air | Integrated compressed air supply |
| Filter Design | Pneumatically actuated reverse-pulse backflush system |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Instrument Type | Online Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Detection Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Typical Configuration | Total VOC (TVOC) Monitoring System |
| Heating Chamber Temperature | 190 °C |
| Detector Sensitivity | ≤1 ppm (CH₄ full scale) |
| Combustion Air Supply | Integrated, self-contained |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-600 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | ppm-level total hydrocarbons (THC), non-methane hydrocarbons (NMHC), and ethane-adjusted NMHC |
| Operating Temperature | Heated FID chamber (typically 180–220 °C) |
| Sample Flow Stability | Precision back-pressure regulator integrated |
| Combustion Air Supply | Internal zero-air generator |
| Compliance | Designed for continuous emission monitoring (CEM) in industrial and environmental applications |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-600-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Total VOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Sensitivity | ≤1 ppm (CH₄ full scale) |
| Heater Chamber Temperature | 190 °C |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-900-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Heating Chamber Temperature | 190 °C |
| Sensitivity (CH₄) | Up to 1 ppm full scale |
| Burner Air Supply | Integrated compressed air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 5-100 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Sensitivity | 1 ppm full-scale for CH₄ |
| Oven Temperature | 190 °C |
| Carrier/Combustion Air | Integrated air supply |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | OVF3000-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable Real-Time Analyzer |
| Typical Configuration | Total Volatile Organic Compounds (TVOC) Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detector Sensitivity | 1 ppm full-scale for CH₄ |
| Heating Chamber Temperature | 190 °C |
| Built-in Air Supply | Yes |
| Operating Time per Hydrogen Cartridge | >40 h |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Instrument Type | Online Analyzer |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Target | Total Volatile Organic Compounds (TVOC) and Non-Methane Hydrocarbons (NMHC) |
| Detection Range | 0–1000 ppm (expandable to 0–100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| FID Sensitivity | ≤1 ppm CH₄ full scale |
| Oven Temperature | 190 °C |
| Carrier/Combustion Air | Integrated zero-air generator |
| Sample Conditioning | Heated sample line & filter with automated back-purge |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VE7-2 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Total VOC Analyzer |
| Measurement Range | 0–1000 ppm (expandable to 0–100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Detector Sensitivity | ≤1 ppm CH₄ full-scale |
| Oven Temperature | 190 °C |
| Carrier/Burner Air Supply | Integrated zero-air generator |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | W600 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detection Principle | Flame Ionization Detection (FID) |
| Full-Scale Sensitivity (CH₄) | 1 ppm |
| Heating Chamber Temperature | 190 °C |
| Dimensions (W×D×H) | 483 mm × 600 mm × 132 mm |
| Carrier/Air Supply | Integrated zero-air generator |
| Compliance | BImSchV 2nd, 13th & 17th Ordinances (Germany), EN 12619, EN 13526, EPA Method 25A, EPA Method 503 |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | W600-1 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | TVOC Monitoring System |
| Measurement Range | 0–1000 ppm (expandable to 100,000 ppm) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Heater Chamber Temperature | 190 °C |
| Dimensions (W×D×H) | 483 × 600 × 132 mm |
| Sensitivity | ≤1 ppm CH₄ full-scale |
| Carrier/Air Supply | Integrated zero-air generator |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-220E |
| Price Range | USD 14,000 – 42,500 (FOB Shanghai) |
| Detection Principle | Dynamic Chamber Method with Integrated PID/EC Sensor Array |
| Instrument Type | Continuous Online Monitoring System |
| Standard Configuration | Integrated TVOC + Formaldehyde Dual-Channel Analysis Module |
| Humidity Control Range | 30–70% RH |
| Humidity Control Accuracy | ±3.0% RH |
| Humidity Resolution | ±2% RH |
| Airflow Velocity in Chamber | 0.1–0.3 m/s |
| Chamber Volume | 1 m³ (standard), configurable to 0.5–5 m³ |
| Temperature Control Range | 15–35°C (±0.5°C stability) |
| Material | Electropolished 316L Stainless Steel Interior with Silicone-Free Sealing |
| Compliance | Meets ASTM D6007–22, ISO 16000-9:2022, GB/T 18883–2022, and JIS A 1912:2020 requirements for chamber-based emission testing |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYK-221S |
| Pricing | Upon Request |
| Detection Principle | Colorimetric Chemical Reaction (Modified Spectrophotometric Endpoint) |
| Lower Detection Limit | 0.05 mg/m³ |
| Measurement Range | 0.00–1.00 mg/m³ |
| Accuracy | ±5% of Full Scale |
| Power Supply | 9 V Alkaline Battery (≥40 h continuous operation) |
| Auto-Power-Off | Activated after 10 min inactivity |
| Dimensions & Portability | Compact handheld form factor, <300 g mass, ergonomic field-deployable design |
| Brand | Jiada Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-211S |
| Detection Limit | 0.05 mg/m³ |
| Measurement Range | 0.00–4.00 mg/m³ |
| Accuracy | ±5% |
| Power Supply | 9 V alkaline battery (≥40 h continuous operation) |
| Auto-power-off | 10 min inactivity |
| Method | Colorimetric reaction with pre-packaged reagent cartridges |
| Dimensions & Weight | Compact handheld design, <300 g |
| Brand | Labthink |
|---|---|
| Model | FT-F1 |
| Type | Benchtop Fogging Test Instrument |
| Standards Compliance | ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G |
| Temperature Range (Hot Plate) | Ambient to 150 °C (optional up to 280 °C) |
| Temperature Control Accuracy | ±0.1 °C at 150 °C |
| Cold Plate Temperature Range | 0–100 °C |
| Cold Plate Control Accuracy | ±0.1 °C |
| Resolution | 0.1 °C |
| Accuracy | ±2% of reading |
| Response Time | <10 min |
| Measurement Methods | Gloss Loss Method (standard), Haze Method (optional), Gravimetric Method (standard, balance not included) |
| Sample Capacity | 6 parallel test positions |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (Hot Unit) | 670 × 490 × 540 mm (L×W×H) |
| Net Weight (Hot Unit, no heat transfer fluid) | 32 kg |
| Dimensions (Cold Unit) | 400 × 220 × 520 mm |
| Net Weight (Cold Unit, no coolant) | 15 kg |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 9100FIRair |
| Detection Principle | Infrared Absorption Spectroscopy (FTIR) |
| Instrument Type | Portable |
| Typical Configuration | Multi-component VOC & Inorganic Gas Analyzer |
| Sampling Method | Pump-aspirated |
| Spectral Range | 485–8500 cm⁻¹ |
| Resolution Options | 1 cm⁻¹, 4 cm⁻¹, or 8 cm⁻¹ |
| Accuracy | ±2% of full scale |
| Response Time | <90 s (gas-dependent) |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GIR320 |
| Detection Principle | Passive Mid-Wave Infrared (MWIR) Optical Gas Imaging (OGI) |
| Instrument Type | Portable |
| Configuration | Multi-gas VOC & hydrocarbon imaging detector |
| Sampling Method | Non-contact passive imaging |
| Temperature Range | −40 °C to 350 °C |
| Resolution | Adjustable spatial resolution (detector-limited) |
| Accuracy | Temperature-dependent radiometric calibration |
| Response Time | <60 s for transient plume detection |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GIR320 (VOC-Specific) |
| Detection Principle | Passive Mid-Wave Infrared (MWIR) Absorption Imaging |
| Instrument Type | Portable |
| Configuration | Integrated VOC-Specific OGI System |
| Temperature Range | −40 °C to 350 °C |
| Resolution | Adjustable (User-Selectable Spatial & Thermal Resolution) |
| Accuracy | Temperature-Dependent (Calibrated per ASTM E1934 & ISO 18434-1) |
| Response Time | <60 s (Initial Detection), 1–60 min (Quantitative Stabilization) |