MingShen Science
Filter
Showing 1–30 of 99 results
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | 101-1A |
| Instrument Type | General-Purpose Forced-Air Oven |
| Temperature Range | 10–250 °C |
| Temperature Uniformity | ±2.5% |
| Temperature Fluctuation | ±1 °C |
| Temperature Resolution | ±1 °C |
| Control Range | 50–300 °C |
| External Dimensions | 760 × 530 × 670 mm |
| Interior Chamber Dimensions | 450 × 450 × 350 mm |
| Chamber Material | Galvanized Steel with Heat-Resistant Coating |
| Heating Method | Forced-Air Circulation |
| Operating Ambient Temperature | 0–55 °C |
| Power Supply | 220 V, 50 Hz |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | AY-8 |
| Temperature Range | 0–999 °C |
| Heating Rate Accuracy | ±30 s/24 h |
| Temperature Accuracy | ±1 °C |
| Sample Chamber Dimensions | 330 × 290 × 120 mm |
| Timing Range | 0–999 min |
| Temperature Resolution | 1 °C |
| Atmosphere | Oxidizing (Air) |
| Power Consumption | ≤5 kW |
| Thermocouple Class | 0.5 grade |
| Time Resolution | 0.1 min |
| Preheating Options | Three selectable preset temperatures |
| Recovery Performance | Furnace returns to pre-insertion temperature within 7 min |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CY/TF |
| Price Range | USD 32–63 |
| Material | Standard 201 Stainless Steel (304 SS Optional) |
| Handle Length | 710 mm (CY/TF1), 810 mm (CY/TF2), 830 mm (CY/TF3) |
| Scoop Width | 100 mm (CY/TF1), 190 mm (CY/TF2), 300 mm (CY/TF3) |
| Scoop Depth | 80 mm (CY/TF1), 100 mm (CY/TF2), 120 mm (CY/TF3) |
| Max Particle Size Handled | 25 mm (CY/TF1), 50 mm (CY/TF2), 100 mm (CY/TF3) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CZ10 |
| Vibration Force | 100 kgf |
| Power Consumption | 0.008 kW |
| Vibration Frequency | 3000 rpm |
| Operating Voltage | 220 V AC |
| Applicable Bin Wall Thickness | 0.6–0.8 mm |
| Weight | 2 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DB |
| Price Range | USD 45 – 92 |
| Material | AISI 304 Stainless Steel |
| Compliance | Designed per GB/T 474 & GB/T 475 |
| Available Sizes | DB300 (Φ300 mm), DB400 (Φ400 mm), DB500 (Φ500 mm), DB600 (Φ600 mm), DB700 (Φ700 mm), DB800 (Φ800 mm), DB900 (Φ900 mm), DB1200 (Φ1200 mm) |
| Dimensions (DB800) | Diameter 800 mm, Plate Height 220 mm, Handle Length 900 mm |
| Surface Finish | Electropolished, Non-porous, Corrosion-Resistant |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DL-1 |
| Detection Principle | Coulometric Titration (per GB/T 214–2007) |
| Furnace Max Temp | 1500 °C (continuous operation at 1200 °C) |
| Heating Rate | 20–25 °C/min |
| Isothermal Zone | 80 mm (±10 °C) |
| Furnace Tube | Dual-threaded silicon carbide tube (Φ70/60 × 250/100 × 30 mm) |
| Reaction Tube | Alumina tapered tube (Φ22/18 × 760 mm) |
| Temperature Control Range | 0–1600 °C |
| Power Consumption | ~4 kW |
| Supply | 220 V, 50 Hz |
| Thermocouple | Pt-Rh/Pt (Class I accuracy, 0–1600 °C) |
| Net Weight | ~80 kg |
| Dimensions (L×W×H) | Furnace unit: 760×300×410 mm |
| Absorption unit | 340×150×320 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | DMF300 |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Max. Power | 3.5 kW |
| Supply Voltage | 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 550×550×550 mm |
| Net Weight | 30 kg |
| Safety Protections | Thermocouple fault detection (open/short/reversed), over-temperature cutoff, automatic heating circuit disconnection |
| Compliance | GB/T 212–2008 |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | DS2-1000N |
| Max Test Force | 100 kN |
| Loading Method | Manual |
| Platen Spacing | >100 mm |
| Force Range | 0–1000 N (0–100 kgf) |
| Resolution | 1 N (0.1 kgf) |
| Sampling Rate | 1000 Hz |
| Display | 4-digit LCD |
| Operating Temp | −20°C to +40°C |
| Power | Rechargeable 6-cell battery or 220 V AC adapter |
| Interface | USB |
| Dimensions (L×W×H) | 360 × 260 × 560 mm |
| Weight | ~25 kg |
| Compliance | MT/T 748–2007, Local Standard for Boiler Honeycomb Briquettes |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | DSF-8 |
| Power | 0.75 kW |
| Splitting Ratio | 1:8 (adjustable) |
| Capacity | 1200 kg/min |
| Dimensions (L×W×H) | 800×550×920 mm |
| Inlet Opening | 70×70 mm |
| Weight | 130 kg |
| Voltage | 380 V AC |
| Sealing Type | Fully Enclosed with Optional Environmental Exhaust Port |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EP Series |
| Instrument Type | Jaw Crusher |
| Sample Applicability | Hard and Medium-Hard Materials (e.g., coal, ore, rock, limestone, ceramics) |
| Maximum Feed Size | ≤ 100 mm |
| Adjustable Discharge Size Range | 1–15 mm |
| Batch Processing Capacity | 200–600 kg/h |
| Motor Power | 1.5–3 kW |
| Dimensions (L×W×H) | 680×400×620 mm to 800×490×950 mm |
| Weight | 85–170 kg |
| Voltage | 380 V AC, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | EPS 1/8 |
| Instrument Type | Laboratory Crusher & Mechanical Divider |
| Sample Applicability | Hard, Brittle Bulk Materials (e.g., Coal, Rock, Ore, Clinker) |
| Feed Size | ≤120 mm |
| Adjustable Output Particle Size | 3–25 mm |
| Final Discharge Size | ≥0.5 mm |
| Throughput Capacity | 300–500 kg/h |
| Division Ratio Options | 1:2, 1:4, 1:8 (primary) |
| 1 | 9 (secondary via dual-stage division) |
| Moisture Tolerance (as-received basis) | ≤11% |
| Power Supply | 3-phase AC 380 V, 50 Hz |
| Motor Power | 3 kW |
| Net Weight | ~400 kg |
| Dimensions (L×W×H) | 1100 × 590 × 1160 mm |
| Compliance | Designed per GB/T 474–2008 “Method for Preparation of Coal Samples” |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FC-6 |
| Voltage | 220 V AC, 50 Hz |
| Current Rating | 1.5 A |
| Power Consumption | 180 W |
| Drum Material | Stainless Steel (AISI 304) |
| Drum Inner Diameter | 220 mm |
| Maximum Sample Mass | < 2 kg |
| Net Weight | 40 kg |
| Drive System | V-belt transmission with step-start pulley |
| Safety Compliance | Grounded chassis, interlocked lid switch (mechanical), centrifugal brake stop |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | FCL-1 |
| Temperature Control Accuracy | ±5°C at 1100°C |
| Temperature Range | Ambient to 1300°C |
| Heating Time | ≤25 min to 1100°C |
| Method | High-Temperature Combustion Hydrolysis |
| Fluorine Analysis Compliance | GB/T 4633–2014 |
| Chlorine Analysis Compliance | GB/T 3558–2014 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3.5 kW |
| Stirring Speed | Continuously Adjustable with Digital Display |
| Flowmeter Range | 0–1000 mL/min (graduation: 10 mL/min) |
| High-Temperature Furnace | Capable of ≥1100°C with ≥80 mm uniform zone at 1100±5°C |
| Combustion Tube | Fused Quartz, Rated ≥1200°C |
| Voltage Control for Evaporation | Solid-State Relay, 0–220 V Continuous Adjustment |
| Temperature Controller | PID-Based with Low-Drift Components |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Float-Sink Test Scoop |
| Price | USD 7.20 (ex-works) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FS-100 |
| Instrument Type | High-Speed Rotor Crusher |
| Sample Applicability | Hard & Brittle Materials (e.g., coal, ore, non-metallic minerals, brittle metals) |
| Feed Size | <13 mm |
| Output Particle Size | 0.01–0.5 mm (equivalent to 200 mesh) |
| Batch Capacity | 50 g |
| Input Voltage | 220 V AC |
| Motor Power | 480 W |
| Rotational Speed | 24,000 rpm |
| Chamber Diameter | 100 mm |
| Continuous Operation Limit | ≤5 min |
| Cooling Interval | ≥10 min |
| Blade Material | Stainless Steel (2Cr13) |
| Net Weight | 2.9 kg |
| Dimensions (L×W×H) | 150×150×300 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | GF-3000 |
| Power Supply | 220 V, 50 Hz, 6 kW (main unit) |
| Gas Requirements | O₂ purity ≥99.5%, regulated pressure 0.25 MPa |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 35–85% RH |
| Atmospheric Pressure | 86–106 kPa |
| Sample Mass | 0.9000–1.1000 g |
| Furnace Temperature Range | Ambient to 1000 °C |
| Capacity | Up to 19 samples per run |
| Dimensions | 655 × 600 × 575 mm (L×W×H) |
| Weight | 60 kg |
| Compliance | GB/T 212–2001 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GF-6000 |
| Furnace Configuration | Dual independent furnaces (A-furnace for moisture/ash/volatiles |
| Sample Capacity | 19 samples per run |
| Temperature Range | Ambient to 1000 °C |
| Test Temperatures | Moisture at 105 °C, Ash at 815 °C, Volatiles at 900 °C |
| Sample Mass | Moisture/Ash: 0.6–1.1 g |
| Volatiles | 0.9–1.1 g |
| Compliance | Fully conforms to GB/T 212–2008 “Methods for Proximate Analysis of Coal” |
| Gas Requirements | N₂ and O₂, both ≥99.5% purity, regulated to 0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | A-furnace: 5 kW |
| B-furnace | 2 kW |
| Net Weight | A-furnace ≈ 95 kg |
| Crucible Capacity | 20 positions (19 active test stations) |
| Integrated Analytical Balance | Modular high-stability microbalance with automated tare and sample loading |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | GJ-1 |
| Instrument Type | Pulverizer |
| Sample Type | Hard Materials (Metals, Coal, Coke, Ores, Granular Solids) |
| Feed Size | ≤13 mm |
| Output Particle Size | 80–200 mesh (0.2 mm nominal) |
| Discharge Fineness Range | 0.01–0.5 mm |
| Loading Capacity | 100 g |
| Motor Power | 1.5 kW |
| Supply Voltage | 380 V AC |
| Weight | 120 kg |
| Dimensions (W×D×H) | 480×480×690 mm |
| Grinding Bowl Material | Manganese Steel |
| Bowl Quantity | 1 |
| Processing Time | 1–5 min |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GJ-3Y |
| Instrument Type | Laboratory Sample Mill |
| Sample Applicability | Hard Non-Metallic Minerals |
| Output Particle Size | 0.01–0.5 mm |
| Input Particle Size | <13 mm |
| Output Mesh Range | 80–300 mesh |
| Batch Grinding Capacity | 300 g (3 × 100–150 g) |
| Control Mode | Automatic with Hydraulic Clamping |
| Motor Power | 1.5 kW × 2 |
| Voltage | 380 V AC |
| Operating Time | 1–3 min per batch |
| Standard Mortar Material | High-Manganese Steel |
| Number of Mortars | 3 |
| Noise Level | Low |
| Mounting | Freestanding (no anchoring required) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GZ Series |
| Price Range | USD 37 – 315 |
| Voltage Compatibility | AC/DC Configurable |
| Construction | Wound-Type Solenoid with Insulated Bobbin, Enamel-Coated Copper Wire, and Interleaved Insulation Paper |
| Operating Voltage Tolerance | 85–110% of Rated Voltage |
| Core Actuation Principle | Electromagnetic Attraction with Spring-Return Release |
| Structural Variants | Open-Type & Enclosed-Type Mounting Configurations |
| Custom Fabrication | Available per OEM Drawings and Technical Specifications |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GZ1 |
| Price | USD 350 (FOB Henan) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HDL-600H |
| Measurement Principle | Coulometric Titration |
| Sulfur Range | 0.01–40% |
| Resolution | 0.001% |
| Analysis Time | 4–8 min (sample-dependent) |
| Combustion Temperature | 1150 °C (coal), 920 °C (heavy oil) |
| Temperature Control Accuracy | ±3 °C |
| Sample Mass | 50 mg ±5 mg (coal), 80–100 mg (heavy oil) |
| Sample Capacity | 1–24 positions per run |
| Compliance | GB/T 214–1996 |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3.5 kW |
| Dimensions (W×D×H) | 1100 × 540 × 450 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HDL-600S |
| Measurement Principle | Coulometric Titration |
| Sample Capacity | 1–24 samples (batch + on-the-fly addition) |
| Sulfur Detection Range | 0.1–40% |
| Resolution | 0.001% |
| Temperature Control | 1150 °C (coal), 920 °C (oil) |
| Temperature Stability | ±3 °C |
| Sample Mass | 40–70 mg (coal), 50–100 mg (oil) |
| Test Duration | 4–8 min per sample |
| Power Supply | 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤5 kW |
| Dimensions | 550 × 500 × 630 mm |
| Weight | 40 kg |
| Compliance | GB/T 214–2007, GB/T 214–1996 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HDL-9 |
| Detection Principle | Coulometric Titration (ASTM D3177, GB/T 214, ISO 4299) |
| Application Scope | Coal, Coke, Iron Ore, Steel Slag, Limestone, Fly Ash, and Other Inorganic Solids |
| Compliance | GB/T 214–2007, ASTM D3177–22, ISO 4299:2021 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HDL-9W |
| Detection Principle | Coulometric Titration (Microcoulometry) |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.1–40 wt% |
| Analysis Time | 3–9 min per sample |
| Detection Limit | 0.01 wt% (as specified in GB/T 214) |
| Display Interface | Dual-mode (Chinese LCD + PC-controlled) |
| Operating Temperature Range | 600–1150 °C (user-selectable |
| Carrier Gas Flow Rate | 1000 mL/min |
| Heating Element | Silicon Carbide Tube (340 mm length) |
| Power Supply | 220 V AC, 50 Hz, 2 kW |
| Compliance | GB/T 214–2007 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HKP-650 |
| Wavelength | Fixed at 650 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.05 nm |
| Spectral Bandwidth | 1.7 nm |
| Absorbance Range | –0.4 to 4.0 A |
| Concentration Display Range | 0–99999 (unitless or customizable units) |
| Stray Light | ≤0.05% T |
| Baseline Flatness | ±0.002 A |
| Drift Stability | ±0.0007 A/h |
| Display | 7-inch color TFT touchscreen (Chinese UI) |
| Sample Chamber | Large-volume cuvette compartment |
| Output Interfaces | USB, RS-232 |
| Compliance | Designed per GB/T 216–2003 for phosphorus determination in coal |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HM-60 |
| Motor Power | 90 W |
| Main Shaft Speed | 20 ± 1 rpm |
| Total Rotations | 60 ± 0.25 rev |
| Applied Load | 284 ± 2 N |
| Voltage Options | 220 V or 380 V (default 380 V) |
| Net Weight | 90 kg |
| Dimensions (L×W×H) | 440 × 380 × 500 mm |
| Compliance | GB/T 2565–2014 (revised version of GB 2565–87) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HR-3 |
| Furnace Type | Horizontal High-Temperature Furnace |
| Heating Element | Silicon Carbide (SiC) Tube |
| Max Temp | 1600 °C |
| Temp Resolution | 1 °C |
| Temp Accuracy | ≤0.2% FS |
| Thermocouple | Pt-Rh/Pt (Type S) |
| Controlled Ramp Rates | 15–20 °C/min up to 900 °C |
| Imaging System | CCD Camera with Real-Time Digital Capture |
| Image Storage Interval | 1 min ≥900 °C |
| Compliance | GB/T 219–2008 |
| Communication Interface | RS-232 (with optional USB adapter) |
| Software Platform | Windows XP or later |
| Dimensions (L×W×H) | 900×380×470 mm |
| Weight | 45 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HR-4 |
| Temperature Range | Ambient–1600 °C (resolution: 1 °C, S-type thermocouple) |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Temperature Accuracy | ±3 °C |
| Timing Range | 0–999 min (1 s resolution <10 min) |
| Timing Drift | <1 s/h |
| Max Output Current | ≤30 A |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | 0–40 °C, RH ≤80% |
| Control Core | Microcontroller-based closed-loop phase-angle SCR control with auto-calibration of temperature and current |
| Compliance | Designed per GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility Determination) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HWSK-6 |
| Channel Count | Single-channel |
| Display | Backlit LCD with Chinese UI |
| Input Sensor | Type K thermocouple |
| Temperature Range | Ambient to 1000 °C |
| Resolution | 0.1 °C |
| Temperature Accuracy | ±3 °C |
| Time Programmability | 000–999 min (1-min resolution) |
| Control Algorithm | PID |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Load Power | ≤5 kW |
| Enclosure Material | Cast iron |
| Dimensions | 330 × 290 × 120 mm (L×W×H) |
| Mounting | Benchtop fixed installation |
| Weight | ~6 kg |
| Operating Environment | 0–40 °C, RH ≤80% |
| Cold-junction Compensation | Integrated constant-current circuit |
| Programmable Ramp Profiles | Up to 15 segmented temperature/time steps |