MingShen Science
Filter
Showing 31–60 of 99 results
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-2 |
| Price | USD 2,250 (approx.) |
| Furnace Max Temp | 1500 °C |
| Operating Temp Range | 1200–1300 °C |
| Heating Rate | 20–25 °C/min |
| Hot Zone Length | 100 mm |
| Silicon Carbide Tube | Dual-threaded, Φ45/35 × 500/100 mm, 40 mm active length |
| Reaction Tube | Alumina, Φ25/20 × 850 mm |
| Temperature Sensor | Pt–Rh/Pt thermocouple, 0–1600 °C, Class 1.0 accuracy |
| Power Consumption | 4–5 kW |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Net Weight | 90 kg |
| Dimensions (Furnace) | 400 × 460 × 980 mm |
| Gas Analyzer Range | 0–99% CO₂, Accuracy: ±2% FS |
| Gas System | CO₂ purification train (pressure regulator, scrubbers, desiccant tower, flowmeter), buoyancy-type gas collection cylinder (Φ360 × 750 mm) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jack-Type Hydraulic Press |
| Load Capacity Options | 2 t, 5 t, 10 t, 16 t, 20 t, 50 t |
| Stroke | 125 mm / 140 mm (model-dependent) |
| Hydraulic Fluid | ISO VG 10 mineral oil (pre-filled) |
| Compliance | Designed for laboratory sample preparation per ASTM D7580, ISO 13320 (powder compaction), and GLP-aligned workflows |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JB-2 |
| Pricing | USD 92 (based on ¥650 @ 7.07 exchange rate) |
| Technology | Coulometric Titration |
| Air Flow Rate | 1000 mL/min |
| Power Supply | 220 VAC |
| Dimensions (L×W×H) | 240 × 180 × 295 mm |
| Core Components | Electromagnetic Pump, Glass Rotameter with Needle Valve, Dual-Stage Drying Tube (Silica Gel + Acid Scavenger) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | JC-2 |
| Compliance | GB/T 479 |
| Temperature Control Range | Ambient to 1100 °C |
| Control Accuracy | ±1 °C |
| Heating Rate | 30 min to 250 °C |
| Temperature Measurement Error | ±3 °C |
| Temp. Resolution | 1 °C |
| Timer Range | 0–999 min |
| Timing Accuracy | ±1 min |
| Time Resolution | 1 min |
| Heating Element | Silicon Carbide Rods |
| Thermocouple Type | K-type |
| Total Power Rating | 2 × 4 kW |
| Continuous Operation | 24 h |
| Recording Drum Linear Speed | 1 mm/min (±2 mm over 160 min) |
| Cold-Junction Compensation | 0–60 °C |
| Power Supply | 220 V ±10 %, 50 Hz ±2 % |
| Host Dimensions (L×W×H) | 800 × 400 × 580 mm |
| Controller Dimensions | 330 × 290 × 120 mm |
| Host Weight | 96 kg |
| Controller Weight | 7 kg |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JC-9 |
| Temperature Range | 0–999 °C (Accuracy Class 0.5, Resolution: 1 °C, K-type Thermocouple) |
| Timer Range | 0–999 min |
| Heating Rate Control | 3 °C/min from 250 °C to 730 °C within 30 min |
| Time Accuracy | ±30 s per 24 h |
| Time Resolution | 0.1 min |
| Power Consumption | 4 kW |
| Supply Voltage | 220 V, 50 Hz |
| Net Weight | 150 kg |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JCM-2 |
| Power | 120 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Motor Speed | 1400 rpm |
| Dimensions (L×W×H) | 360 mm × 240 mm × 300 mm |
| Weight | 19 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JX-2 |
| Price | USD 2,700 (approx.) |
| Compliance | GB/T 1572–1989 |
| Sample Size | 400 cm³ |
| Particle Size Range | 3–6 mm |
| Required Air Blower | ≥12 m³/h airflow, ≥1000 mmHg pressure |
| Sieve Aperture | 6 mm |
| Slag Retention Measurement | Mass fraction (%) of residue >6 mm after vibratory sieving |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | JXL-620 |
| Type | Box-type Muffle Furnace |
| Max Temperature | 1000 °C |
| Temperature Control Accuracy | ±5 °C |
| Max Power | 3.5 kW |
| Heating Rate to Max Temp | ≤20 min |
| Heating Method | Resistance Wire (Ni-Cr Alloy) |
| Internal Chamber Dimensions | 300 × 200 × 120 mm |
| Thermal Sensor | K-type Thermocouple (NiCr-NiSi) |
| Control System | Microprocessor-based with 20-Stage Programmable Ramp/Soak Profile |
| Display | Chinese LCD with Touch Keypad |
| Insulation Material | Polycrystalline Ceramic Fiber |
| Voltage | 220 V ±10% |
| Net Weight | 55 kg |
| External Dimensions | 680 × 600 × 670 mm (L×W×H) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JYS-200 |
| Principle | Electromechanical Vibratory Sieving |
| Sieve Diameter | Φ200 mm |
| Max Load Capacity | 8 kg |
| Stackable Sieve Layers | 8 |
| Standard Sieve Diameters | Φ200 / Φ100 / Φ75 mm |
| Particle Size Range | 38 µm – 3 mm |
| Noise Level | ≤50 dB(A) |
| Max Single Batch Feed | 200 g |
| Vibration Amplitude | ≤5 mm |
| Motor Speed | 1420 rpm |
| Power Supply | AC 220 V, 50 Hz |
| Motor Power | 0.125 kW |
| Net Weight | 40 kg |
| Dimensions (L×W×H) | 400 × 300 × 736 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | KER-86 |
| Material | 304 Stainless Steel |
| Compliance | GB/T 474 |
| Sample Throughput Capacity | ≤13 mm (Large), ≤6 mm (Medium), ≤3 mm (Small), ≤1.25 mm (Extra-Small) |
| Groove Width | 39 mm / 18 mm / 9 mm / 5 mm |
| Groove Count | ≥8 per side |
| Groove Inclination Angle | ≥60° from horizontal |
| Minimum Opening Size | ≥5 mm |
| Sealing Integrity | Tight-fitting receiver assembly to prevent fines and moisture loss |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | KH-3 |
| Temperature Control Range | 100–1000 °C |
| Temperature Measurement Accuracy | Class 0.2 |
| Temperature Control Stability | ±10 °C |
| Furnace Length | 700 mm |
| Isothermal Zone Length | ≥200 mm |
| Conveyor Speed | 15–70 mm/min |
| Isothermal Uniformity at 815 °C | ±10 °C over ≥150 mm |
| Heating Time (RT → 815 °C) | ≤45 min |
| Rated Power | 3 kW |
| Supply Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Dimensions (L×W×H) | 1200 × 420 × 505 mm |
| Net Weight | 70 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KZDL-8H |
| Pricing | USD 1,350 (FOB) |
| Measurement Principle | Coulometric Titration (ASTM D3177, GB/T 214, ISO 4299) |
| Sulfur Range | 0.1–40 wt% |
| Combustion Time | 3–9 min per sample |
| Furnace Temp Control | 1150 ± 5 °C (adjustable, SiC heating element, hot zone ≥90 mm) |
| Temperature Sensor Accuracy | Class 0.5 |
| Heating Rate | 25–30 °C/min (reaches 1200 °C in ~35 min) |
| Electrolytic Cell Volume | 450 mL (organic glass construction with sintered glass frit gas diffuser) |
| Stability | Stable operation within 60 seconds after power-on |
| Power Supply | 220 V ± 20 V AC, 50 Hz |
| Dimensions (mm) | Controller: 365 × 155 × 340 |
| High-Temp Furnace | 580 × 250 × 270 |
| Air Purifier Unit | 258 × 300 × 360 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KZDL-9C |
| Measurement Principle | Combustion-Iodometric Titration (Dry Colorimetric Method per GB/T 2462–1996) |
| Power Supply | 220 V ±20 V, 50 Hz |
| Max. Power Consumption | ≤2.5 kW |
| Sulfur Range | 0.01–99.99 wt% |
| Resolution | 0.01 wt% |
| Temperature Control Range | 300–1300 °C |
| Temp. Display Range | Ambient to 1300 °C |
| Temp. Resolution | 1 °C |
| Target Temp. Setpoint Accuracy | ±5 °C at 1150 °C |
| Heating Time | ~25 min to reach 1150 ±5 °C |
| Sample Positioning | Dual-Hall Element Driven Multi-Stage Auto-Sampling |
| Furnace Design | Horizontal High-Temperature Tube Furnace |
| Dimensions (L×W×H, mm) | Controller: 370×350×170 |
| Furnace | 580×250×270 |
| Purifier | 180×245×300 |
| Net Weight | Controller 5 kg, Furnace 15 kg, Purifier 4 kg |
| Compliance | GB/T 2462–1996, ASTM D4294 (referenced methodology), ISO 8754 (equivalent combustion principle) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | Lever-Actuated |
| Max. Sample Mass | ~1 g per press |
| Standard Pellet Diameter Options | 6 mm, 8 mm, 12 mm, 20 mm, 40 mm, 60 mm |
| Compliance | Designed for ASTM D5865, ISO 1928, and GB/T 213-compliant calorimetric sample preparation |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LM |
| Price | USD 92 (FOB) |
| Input Voltage Range | ±15% of 220 VAC |
| Control Signals | 4–20 mA, 0–5 VDC |
| Output Trigger Type | Single-Phase Phase-Angle Control |
| Isolation | Optocoupled Input/Output |
| Operating Temperature | –20 °C to +40 °C |
| Relative Humidity | ≤85% RH at 25 °C |
| Conducted Current | 50 mA |
| On-State Voltage Drop | <1.5 V |
| Off-State Leakage Current | <10 mA |
| Turn-On Time (50 Hz) | 1 ms |
| Turn-Off Time | 10 ms |
| Dimensions (L×W×H) | 210 × 135 × 270 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Manual Wooden-Frame Coal Sample Sieve |
| Price Range | USD 55 – 83 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDH |
| Capacity Options | 500 mL and 1000 mL |
| Dimensions (500 mL) | Height 205 mm, Base Diameter 120 mm, Mass 210 g |
| Dimensions (1000 mL) | Height 250 mm, Base Diameter 145 mm, Mass 300 g |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MFQ |
| Price Range | USD 120 – 350 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MK-8 |
| Drum Internal Diameter × Length | 1000 mm × 1000 mm ±5 mm |
| Rotational Speed | 25 rpm (100 revolutions in 4 min ±10 s) |
| Motor Power | 2.2 kW |
| Net Weight | 970 kg |
| Overall Dimensions (L×W×H) | 1830 mm × 1350 mm × 1800 mm |
| Voltage | 380 V / 220 V AC |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-6000 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Range | 0–40 °C (ambient variation ≤1 °C per test) |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Duration | 18–20 min (coal samples with low calorific value may require extended duration) |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 50 L |
| Inner Bucket Volume | 2.3 L |
| Power Consumption | <500 W |
| Supply Voltage | 220 V ±10 V |
| Dimensions (W×D×H) | 450 mm × 580 mm × 480 mm |
| Ignition Voltage | 24 V |
| Compliance | GB/T 213–2003 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MLR-7000 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibol Calorimetry |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ±0.1% (RSD) |
| Single-Sample Test Duration | ~15 min |
| Heat Capacity | 10,500–11,000 J/K |
| Outer Water Jacket Volume | 30 L |
| Inner Water Bucket Volume | 2.1–2.3 L |
| Ignition Voltage | 24 V DC |
| Ignition Duration | 6 s |
| Operating Ambient | 5–40 °C |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | <80 W |
| Net Weight | 50 kg |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-8000 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ≤0.1% RSD |
| Single-Sample Test Duration | ≤15 min (GB/T 213 compliant) |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 30 L |
| Inner Water Bucket Volume | 2.1 L |
| Oxygen Pressure Range | 2.8–3.0 MPa |
| Ignition Voltage | 24 V DC |
| Power Consumption | <500 W |
| Dimensions (Main Unit) | 500×460×600 mm |
| Weight | 45 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | 0–65 °C |
| Temperature Resolution | 0.0001 K |
| Precision | ±0.1% RSD |
| Single-Sample Test Duration | ~15 min |
| Heat Capacity | ~10,500 J/K |
| Outer Water Jacket Volume | 51 L |
| Inner Water Bucket Volume | 2.3 L |
| Ignition Voltage | AC 24 V (5 s duration) |
| Oxygen Bomb Material | Ni-Cr-Mo Alloy |
| Bomb Pressure Rating | 20 MPa |
| Charging Pressure | 2.8–3.0 MPa |
| Power Supply | 220 V ±10%, 30 W |
| Dimensions (L×W×H) | 660 × 500 × 540 mm |
| Weight | ~30 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MLR-8W |
| Temperature Measurement Range | 0–65 °C |
| Temperature Resolution | 0.0001 °C |
| Sample Mass | 0.5–1.5 g |
| Heat Capacity | ~10,500 J/K |
| Outer Water Jacket Volume | ~51 L |
| Inner Water Bucket Volume | ~2.1 L |
| Ignition Voltage | 20 V |
| Ignition Duration | Programmable (3–8 s) |
| Water Quantification Accuracy | ≤ ±1 g |
| Ambient Operating Conditions | 5–40 °C, ≤30% RH (max ΔT ≤1 °C per test) |
| Power Supply | AC 220 V |
| Dimensions | 450 × 580 × 480 mm |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MLR-9C |
| Instrument Type | Oxygen Bomb Calorimeter |
| Temperature Range | 0–65 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | < 0.2% (over 10 min) |
| Precision (Heat Capacity) | ≤ 0.1% RSD |
| Single-Sample Test Time | ≤ 20 min |
| Heat Capacity | 10,500 J/K |
| Outer Water Jacket Volume | 51 L |
| Inner Water Bucket Volume | 2.3 L |
| Oxygen Bomb Volume | 300 mL |
| Cooling Method | Semiconductor Refrigeration |
| Power Supply | 220 V ±10%, 30 W |
| Dimensions (Main Unit) | 650 × 500 × 460 mm (L×W×H) |
| Dimensions (Chiller Unit) | 510 × 380 × 425 mm (L×W×H) |
| Weight (Main Unit) | 40 kg |
| Weight (Chiller Unit) | 17 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MRD-6M |
| Power | 800 W |
| Temperature Range | Ambient to 500 °C |
| Resolution | 1 °C |
| Repeatability Error | ≤5 °C |
| Heating Rate | 4.5–5.0 °C/min |
| Sample Capacity | 6 samples per run |
| Operating Environment | 5–40 °C, RH ≤80% |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Dimensions (H×W×D) | 350 mm × 370 mm × 240 mm |
| Weight | 15 kg |
| Compliance | GB/T 18511–2001 |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-3000 |
| Measurement Principle | Coulometric-Gravimetric Method |
| H Range | 0–20 wt% |
| C Range | 1–99 wt% |
| Sample Mass | 70–75 mg (air-dried, <0.2 mm) |
| Analysis Time | ~10–15 min (including isothermal holds at 300°C for 30 s, 500°C for 2 min, and 850°C for ~10 min) |
| Electrolysis Voltage | Coating: 10 V |
| Operational | 24 V |
| Electrolysis Current | >600 mA (initial), <70 mA (endpoint) |
| Accuracy | Complies with GB/T 15460–2003 (H: ±0.15 wt%, C: ±0.50 wt%) |
| Heating Rate | ~50 min to 850°C |
| Linearity & Stability | ±0.1% full scale |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSCQY-5000 |
| Measurement Principle | Coulometric–Gravimetric Method |
| Carbon Range | 1–99 wt% |
| Hydrogen Range | 1–20 wt% |
| Furnace Temp. | 850 °C ±10 °C (combustion), 400 °C ±10 °C (reduction) |
| Electrolysis Voltage | 24 V (main), 10 V (coating film) |
| Electrolysis Current | >500 mA (working), <70 mA (endpoint) |
| Test Duration | 9–13.5 min |
| Linearity of Coulometric Integrator | ±0.1% |
| Max. Permissible Error | H ≤0.15 wt%, C ≤0.50 wt% |
| Sample Particle Size | <0.2 mm |
| Heating Rate | 25–30 °C/min |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSSC-5000 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Drying Methods | Microwave, Infrared, or Combined |
| Microwave Power | Adjustable via software |
| Sample Mass (Total Moisture) | 10–12 g, weighed to 0.001 g |
| Sample Mass (Analytical Moisture) | 1.45–1.55 g, weighed to 0.0001 g |
| Balance Resolution | 0.0001 g |
| Balance Capacity | 0–195 g |
| Total Moisture Drying Time | 12–15 min (adjustable) |
| Analytical Moisture Drying Time | ~10 min (adjustable) |
| Max. Sample Capacity per Batch | 9 specimens |
| Particle Size (Total Moisture) | <6 mm |
| Particle Size (Analytical Moisture) | ≤80 mesh |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (L×W×H) | 480 × 350 × 540 mm |
| Net Weight | 35 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MTP-6 |
| Power Supply | AC 220 V ±20 V, 50 Hz |
| Power Consumption | ≤25 W |
| Balance Interface | RS-232 serial communication (supports continuous output mode) |
| Data Storage | 200-entry circular buffer (per parameter: moisture, ash, volatile matter, fixed carbon, G-index) |
| Print Function | Single-entry, page-wide, and historical report printing |
| Operating Modes | Error-prevention mode & continuous operation mode (switchable) |
| Compliance Support | ASTM D3172, ASTM D3173, ASTM D3174, ASTM D3175, ISO 1171, ISO 562, ISO 687, GB/T 212–2008 |