MOTIS
Filter
Showing 61–90 of 105 results
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Combustion Source | 31 kW Propane Corner Burner (250 mm × 250 mm × 80 mm) |
| Test Chamber Dimensions | 3 m × 3 m × 2.4 m (W × L × H) |
| Exhaust Flow Rate | 0.50–0.65 m³/s at 298 K |
| Exhaust Duct | SUS304 J-type, Ø315 ±5 mm, insulated with 50 mm mineral wool |
| Cone Calorimetry-Compatible Sampling Zone Length | 2155 mm |
| Oxygen Analyzer | Servomex 4100 (paramagnetic, 16–21% v/v O₂, ≤12 s response, drift <100 ppm/30 min) |
| CO₂ Analyzer | Servomex 4100 (NDIR, 0–10% v/v CO₂, linearity ≥1% FS) |
| Smoke Obscuration System | Incandescent light source (2900 ±100 K), collimated beam ≥20 mm diameter, Si photodiode detector compliant with CIE V(λ) ±5% |
| Thermocouples | Three OMEGA K-type armored, 0.5 mm dia., spaced 120° on 87 ±5 mm radius circle |
| Pressure Transducer | ±2 Pa accuracy, ≤1 s 90% response |
| Mass Flow Controller | 0–2.5 g/s, ±1.5% reading accuracy |
| Propane Supply Control | Dual independent solenoid valves, switch time ≤12 s, flame stabilization ±5 mg/s for 30.7 ±2 kW output |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Gas Analysis | O₂ (0–25% vol), CO (0–1% vol), CO₂ (0–10% vol) |
| Temperature Sensing | K-type thermocouples (up to 1000 °C) |
| Flow Measurement | Stainless steel bidirectional pitot probe with micro-differential pressure sensor |
| Data Acquisition | Multi-channel analog input board (temperature, pressure, gas concentration, flow) |
| Software | ISO/IEC 17025-aligned calibration routines, real-time parameter calculation, audit-trail-enabled reporting |
| Brand | MOTIS |
|---|---|
| Model | SBI |
| Standard Compliance | EN 13823, GB/T 20284 |
| Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Heat Release Rate (HRR) Derivation | Via O₂ depletion in exhaust duct |
| Smoke Production Quantification | Via light extinction coefficient (k) in sampling duct |
| Flame Spread Assessment | Lateral Flame Spread (LFS) on vertical specimen wing |
| Dripping Evaluation | Visual observation and collection of molten droplets |
| Chamber Dimensions | 3 m × 3 m × 2.4 m (W × L × H) |
| Ignition Source | 31 kW propane corner burner (250 mm × 250 mm × 80 mm) |
| Sampling Zone | Integrated in exhaust duct with multi-sensor array (O₂, CO, CO₂, temperature, differential pressure, optical density) |
| Data Acquisition | Simultaneous real-time logging of thermal, gas, and flow parameters |
| Software | Dedicated SBI calibration & analysis suite compliant with EN 13823 Annex A requirements |
| Power Supply | 220 VAC ±10%, 50–60 Hz |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Exhaust Flow Rate | 0.50–0.65 m³/s at 298 K |
| Propane Burner Output | 30.7 ± 2 kW |
| Optical Path Diameter | ≥20 mm |
| Smoke Measurement Resolution | ≤0.1% linear stability |
| O₂ Analyzer | Paramagnetic, 16–21% (v/v), response time ≤12 s, drift ≤100 × 10⁻⁶ (30 min) |
| CO₂ Analyzer | NDIR, 0–10% (v/v), linearity ≥1% FS, response time ≤12 s |
| Thermocouples | Three 0.5 mm sheathed K-type (GB/T 16839.1), spaced at 120° on arc radius (87 ± 5) mm |
| Pressure Sensor | 0–100 Pa, accuracy ±2 Pa, 90% response time ≤1 s |
| Light Attenuation System | Incandescent source at (2900 ± 100) K, DC power stability ±0.5%, 90% response time ≤3 s |
| Data Acquisition Interval | 3 s |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, Droplet Observation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Heat Release Rate Measurement | Oxygen consumption calorimetry |
| Smoke Measurement | Optical density (light extinction) via white-light beam |
| Flame Spread Assessment | Lateral flame spread (LFS) up to 1.5 m × 1.0 m specimen edge |
| Droplet Collection | Integrated metal drip tray with thermal shielding |
| Chamber Dimensions | 3 m × 3 m × 2.4 m (W × D × H) |
| Ignition Source | 31 kW propane corner burner (250 mm × 250 mm × 80 mm) mounted on specimen trolley |
| Sampling Duct | Stainless-steel duct with integrated probe zone for multi-parameter gas analysis |
| Data Acquisition | Simultaneous sampling of O₂, CO, CO₂, flue gas temperature, mass flow, and optical density |
| Analyzer Specifications | Siemens OXYMAT 61 (0–25% O₂, ±1% FS/week drift, <3 s response), U23 NDIR (CO: 0–1%, CO₂: 0–10%, ±0.5% FS linearity) |
| Calibration Support | Full software-based calibration routines per ISO 5660-1 and EN 13823 Annex B |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI- |
| Compliance | GB/T 20284-2006, EN 13823 |
| Power Supply | 380 V AC, 50 Hz |
| Fuel | 95% commercial propane |
| Exhaust Flow Rate | ≥8000 m³/h |
| Gas Flow Control | Mass flow controller (0–2.3 g/s C₃H₈, ±1% FS accuracy) |
| Temperature Measurement | K-type thermocouples (±0.5 °C) |
| Pressure Sensing | Differential pressure transducers (±0.5 Pa) |
| Oxygen Analysis | 0–25% vol, T90 ≤ 2 s, linearity < ±0.1% O₂ |
| CO/CO₂ Analysis | CO (0–1% vol, ±0.02% vol), CO₂ (0–10% vol, ±1% FS), T90 ≤ 2 s |
| Smoke Measurement | White-light extinction method (24 V, 6 W incandescent source |
| Data Acquisition | NI-compatible 16-bit analog input modules, LabVIEW-based real-time system |
| Cooling System | Active chiller (≤5 °C operational setpoint) |
| Filtration | Dual-stage (coarse ≤25 µm, fine ≤3 µm) |
| Exhaust Duct | J-shaped double-walled 304 stainless steel (ID 315 mm) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SCF |
| Compliance | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Roof Deck Substrate | Plywood, 1300 × 1000 × 120 mm |
| Non-combustible Backstop Panel | Stainless steel, installed at rear end of test deck |
| Adjustable Fan-shaped Deflector Plate | 1440 × 940 mm, stainless steel, angle-adjustable |
| Eave Simulator Assembly | 330 × 2130 × 584 mm, non-combustible board mounted at front frame |
| Airflow Velocity | 19 ± 8 km/h (5.5 ± 2.2 m/s), monitored via calibrated anemometer |
| Exhaust Duct | Stainless steel, 2130 × 762 × 3000 mm, equipped with honeycomb flow straightener, guide vanes, and adjustable turbulence plates |
| Fan | 220 V, 50 Hz, three-phase, reverse-flow capable, 0–100% infinitely variable speed control, min. airflow 300 m³/min |
| Gas Burner | 1.12 m long × 60.3 mm OD, linear slit (12.7 mm wide × 0.91 m long), heat output Class A/B: 21,000–22,000 Btu/min (369–387 kWh) for 10 min |
| Class C | 18,000–19,000 Btu/min (316–334 kWh) for 4 min |
| Burner Surface Temperature | 880 ± 10 °C |
| Automatic Ignition System | High-voltage electrode ≥1.8 kVp |
| Mass Flow Control | Precision thermal mass flow meters for repeatable gas delivery per test class |
| Data Acquisition | NI-based LabVIEW system with 16-bit thermocouple input, 16-bit analog input, digital I/O, 12-bit analog output, 4/8-slot chassis, real-time & Ethernet modules |
| Sample Support | Rotatable metal mesh tray with load-bearing capacity for standard PV modules (up to 2.0 m length) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SCF |
| Standards Compliance | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Sample Support Base | 1300 × 1000 × 120 mm Plywood Deck |
| Stainless Steel Fan Duct | 2130 × 762 × 3000 mm |
| Airflow Velocity | 5.5 ± 2.2 m/s (19 ± 8 km/h) |
| Gas Burner Length | 1.12 m, Slot Width: 12.7 mm, Slot Length: 0.91 m |
| Heat Release Rate | Class A/B: 369–387 kWh (21,000–22,000 Btu/min) for 10 min |
| Class C | 316–334 kWh (18,000–19,000 Btu/min) for 4 min |
| Burner Surface Temperature | 880 ± 10 °C |
| Data Acquisition | NI PXI-based LabVIEW system with 16-bit thermocouple input, 16-bit and 12-bit analog I/O modules, real-time & Ethernet communication support |
| Power Supply | 220 V, 50 Hz, 3-phase |
| Minimum Airflow Capacity | 300 m³/min |
| Auto-Ignition Voltage | ≥1.8 kVp |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SC F |
| Compliance Standards | ASTM E108, UL 790, NFPA 256, IEC 61730-2 Annex A |
| Test Chamber Dimensions (L×W×H) | 1020 × 1000 × 1473 mm |
| Test Panel Size | 1300 × 1000 × 120 mm (plywood substrate) |
| Flame Impingement Burner | 1.12 m long × 60.3 mm OD, 12.7 mm × 910 mm slot |
| Heat Release Rate | Class A/B: 21,000–22,000 Btu/min (369–387 kWh) |
| Class C | 18,000–19,000 Btu/min (316–334 kWh) |
| Airflow Velocity | 5.5 ± 2.2 m/s (19 ± 8 km/h) |
| Exhaust Fan Capacity | ≥300 m³/min, variable-speed (0–100%), 220 V / 50 Hz / 3-phase |
| Ignition Voltage | ≥1.8 kVp |
| Burner Surface Temperature | 880 ± 10 °C |
| Data Acquisition | NI-based LabVIEW system with 16-bit thermocouple input, 16-bit and 12-bit analog I/O modules, real-time & Ethernet communication support |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SCV |
| Chamber Dimensions (H×W×D) | 1300 mm × 300 mm × 450 mm |
| Sample Mounting | Dual stainless-steel support rods |
| Burner | 1 kW premixed gas burner (propane/air) |
| Gas Control System | Pressure gauge, pressure-reducing valve, rotameter, shut-off ball valve, and check valve |
| Compliance | IEC 60332-1-1, IEC 60332-1-2, IEC 60332-1-3, EN 50086-1:1994, GB/T 18380.11–2022, GB/T 18380.12–2022 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 mm × 914 mm × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant panel (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Flame Sources | ASTM E662 pilot flame burner, ISO 5659-2 burner, NES 711 burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Pressure Regulation | Top-mounted pressure relief port linked to calibrated volume bottle |
| Safety Features | Explosion-resistant aluminum foil lining, automatic pneumatic actuators for top/bottom access, full-front opening door |
| Cooling | Integrated recirculating water chiller with NIST-traceable water-cooled heat flux meter (50 kW/m² range) |
| Mass Loss Measurement | Built-in balance (0–2000 g, ±0.1 g) for MOD testing and thermogravimetric analysis |
| Calibration & Compliance | Compliant with ASTM E662, ISO 5659-2, NES 711 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²) |
| Combustion Options | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner + mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-resistant aluminum foil lining, pressure-relief port with calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Data Acquisition | Integrated touchscreen PC with dedicated software, GLP-compliant audit trail, built-in thermal printer |
| Optional Modules | Dräger gas detection tubes (toxicity screening), FTIR coupling interface (smoke gas speciation), water-cooled Medtherm heat flux meter (NIST-traceable), wind-cooled copper calorimeter, integrated balance (0–5000 g, ±0.01 g) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Internal Chamber Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners |
| Temperature Control | External auxiliary heating jacket |
| Safety Features | Explosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators |
| Cooling | Integrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided) |
| Weighing System | 0–5000 g capacity, 0.01 g readability |
| Optical Calibration | Motorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection |
| Light Source | Uniform incandescent collimated beam |
| Data Interface | Touchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module |
| Optional Add-ons | Dräger gas detection tubes, FTIR coupling interface for smoke gas speciation |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Ignition Systems | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-proof aluminum foil lining, pressure-relief port linked to calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Cooling | Integrated recirculating water chiller (no external supply required), water-cooled MEDTHERM heat flux meter (NIST-traceable calibration) |
| Mass Measurement | Integrated balance, 0–5000 g range, 0.01 g resolution |
| Data Acquisition | Touchscreen PC-based control software with real-time transmittance logging, automated filter wheel (Clear/Filter/Dark/ND2), built-in thermal printer |
| Compliance | ASTM E662, ISO 5659-2, GB/T 8323, NES 711 |
| Brand | MOTIS |
|---|---|
| Model | SDB |
| Origin | Shanghai, China |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical Detection System | Side-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²) |
| Ignition Sources | ASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan |
| Temperature Control | External Auxiliary Heating Jacket |
| Pressure Regulation | Automatic Pressure Relief Valve with Calibrated Volume Bottle |
| Safety Features | Explosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door |
| Cooling Options | Air-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller |
| Mass Loss Measurement | Integrated Balance (0–5000 g, ±0.01 g) |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711, GB/T 8323 |
| Software | Integrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow |
| Optional Add-ons | Dräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SIT |
| Pricing | Available Upon Request |
| Compliance | EN ISO 11925-2, DIN 53438, GB/T 8626 |
| Chamber Material | SUS304 Stainless Steel |
| Viewing Windows | Dual Tempered Glass Doors |
| Flame Orientation | Adjustable (Vertical or 45°) |
| Flame Height Control | Rotameter with Calibration Gauge |
| Sample Holder | Dual-Mode (Vertical/Horizontal Translation + 90° Rotation) |
| Sample Fixtures | Standard & Wide Stainless Steel Clamps |
| Ignition Position Options | Center-Line (40 mm above bottom edge) / Edge-Ignition (depth-dependent per thickness) |
| Optional Accessories | 0–10 m/s Anemometer, 0.2 s Resolution Timer |
| Brand | MOTIS |
|---|---|
| Model | SIT |
| Principle | Kleinbrenner small-flame impingement (vertical orientation) |
| Standards Compliance | EN ISO 11925-2, DIN 53438, GB/T 8626, DIN 4102-1 (Class B2) |
| Chamber Construction | Full stainless steel |
| Viewing Windows | Dual tempered glass doors |
| Sample Holder | Adjustable vertical/horizontal positioning |
| Ignition Source | Selectable 0° (vertical) or 45° angle |
| Flame Height Control | Rotameter-regulated propane/air flame |
| Flame Measurement | Integrated calibrated flame gauge |
| Airflow Monitoring | 0–10 m/s anemometer |
| Timing Resolution | 0.2 s |
| Accessories | Annex A sample clamp & template set |
| Sample Fixtures | Two interchangeable stainless steel clamps |
| Origin | Shanghai, China |
| Distribution Type | Authorized distributor |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | TOI |
| Price Range | USD 1,400 – 7,000 |
| Category | Combustion Analyzer / Oxygen Index Tester / Physical Property Testing Instrument |
| Compliance | ASTM D2863, ISO 4589-2, GB/T 2406.2, UL 94 (OI correlation), MIL-STD-2031 (applicable for military-grade material screening) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | TPP |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749 |
| Heat Source | Dual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz infrared tubes |
| Total Incident Heat Flux | 83 kW/m² ± 2 kW/m² |
| Radiant Flux Range | 13–40 kW/m² ± 4 kW/m² |
| Calibrated Water-Cooled Heat Flux Sensor | 0–100 kW/m², response <200 ms, emissivity >0.95 |
| Thermocouple Resolution | 0.1 °C, accuracy ±0.75 °C |
| Data Acquisition Rate | 20 Hz (50 ms interval) with cold-junction compensation |
| Gas Flow Control | Rotameter ±2% accuracy, range >3 L/min |
| Inlet Pressure Regulation | 0–15 psi via adjustable regulator |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | TPP |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009 |
| Heat Source | Dual 45° Meker burners + 9-piece T150 quartz infrared array |
| Total Incident Heat Flux | 83 kW/m² ± 2 kW/m² |
| Radiant Flux (IR only) | 13 kW/m² ± 4 kW/m² |
| Calibrated Water-Cooled Heat Flux Sensor | 0–100 kW/m², response time < 200 ms, emissivity > 0.95 |
| Data Acquisition | ≥10 Hz, thermocouple resolution 0.1 °C, accuracy ±0.75 °C, cold-junction compensation |
| Gas Flow Control | Rotameter (±2% accuracy, >3 L/min), pressure regulation (0–15 psi), quarter-turn shutoff valve |
| Software | Standard TPP test suite with real-time flux monitoring, curve plotting, and pass/fail evaluation per NFPA/ASTM protocols |
| Brand | MOTIS |
|---|---|
| Model | TPP |
| Origin | Shanghai, China |
| Compliance | NFPA 1971, ASTM D4018, GB 8965.1–2009, ISO 12749 |
| Heat Source | Dual Meker burners (38 mm, 5/16″ orifice) + 9× T150 quartz IR tubes |
| Total incident heat flux | 83 kW/m² ± 2 kW/m² |
| Radiant flux range | 13–40 kW/m² ± 4 kW/m² |
| Convection source | 800–1200 BTU/h per burner |
| Calibrated water-cooled heat flux sensor | 0–100 kW/m², response <200 ms, emissivity >0.95 |
| Data acquisition | 20 Hz (50 ms interval), 0.1 °C resolution, ±0.75 °C accuracy, cold-junction compensation |
| Gas control | Rotameter (±2% accuracy, >3 L/min), pressure regulator (0–15 psi), quarter-turn shutoff valve |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UIC-4 |
| Standards Compliance | TB/T 3237, UIC 564-2 |
| Sample Holder | Dual stainless-steel clamps with adjustable support stand |
| Ignition System | Electric spark igniter |
| Burner Type | Bunsen burner with 45° and 90° angular adjustment |
| Flame Height Gauge | Integrated calibrated gauge |
| Construction | Stainless-steel frame and combustion chamber components |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UK-1 & UK-2 |
| Compliance | BS 5852:2006, UK Furniture and Furnishings (Fire) (Safety) Regulations 1988 (as amended), CFR 1634 |
| Chamber Dimensions (UK-1) | 450 × 300 × 150 mm |
| Chamber Dimensions (UK-2) | 450 × 450 × 300 mm |
| Construction | Full stainless steel frame and test fixture |
| Ignition Sources | Standard smoldering cigarette (ISO 12403-1), No. 0–No. 7 calibrated ignition sources |
| Included Accessories | Certified standard polyurethane foam (density 25 ± 1 kg/m³), standardized timber crib (ASTM E1321), stainless steel mesh screen (aperture ≤ 1 mm), stainless steel ignition tube, precision-cut stainless steel template for specimen positioning |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Chamber Volume | >0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Large Transparent Observation Port |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Ignition Source | Bunsen Burner (ASTM D5025 Compliant) |
| Flame Geometry | Fan-shaped Burner (ASTM D4986 Compliant) |
| Gas Flow Control | Rotameter + High-Precision Pressure Regulator |
| Exhaust System | Top-mounted Forced Ventilation |
| Optional Accessory | Burner Calibration Kit (ASTM D5207 Compliant) |
| Standards Supported | UL 94 HB/V-0/V-1/V-2/5VA/5VB/VTM-0/VTM-1/VTM-2/HF-1/HF-2/HBF |
| Referenced Standards | IEC 60695-11-10, IEC 60695-11-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | UL94-X |
| Compliance | UL 94 HB, V0/V1/V2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Extra-Large Transparent Borosilicate Glass |
| Burner Types | Bunsen (ASTM D5025), Fan-Shaped (ASTM D4986) |
| Burner Angle Adjustment | 0°, 20°, 45° |
| Gas Flow Control | Precision Rotameter + High-Accuracy Pressure Regulator |
| Exhaust System | Top-Mounted Forced Ventilation |
| Optional Accessory | ASTM D5207 Compliant Burner Calibration Kit |
| Regulatory Alignment | IEC 60695-11-10/-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Compliance | UL 94 (HB, V-0/V-1/V-2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF) |
| Standards | UL 94, IEC 60695-11-10/-20, ISO 1210, ISO 9770, ISO 9772, ISO 9773, GB/T 2408, GB/T 5169.17, GB/T 8332, ASTM D5025, ASTM D4986, ASTM D5207 |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte black non-reflective surface |
| Viewing Window | Large transparent borosilicate glass viewport |
| Burner Adjustment | 0°, 20°, 45° tilt positions |
| Gas Control | Precision pressure regulator + rotameter for propane/butane flow |
| Exhaust System | Top-mounted forced-air exhaust duct with fume hood interface |
| Optional Accessory | ASTM D5207-compliant burner calibration kit |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | UL94-X |
| Compliance | UL 94 (HB, V-0/V-1/V-2, 5VA/5VB, VTM-0/1/2, HF-1/HF-2/HBF) |
| Chamber Volume | ≥0.75 m³ |
| Interior Finish | Matte Black |
| Viewing Window | Extra-Large Tempered Glass |
| Burner Adjustment | 0°, 20°, 45° |
| Gas Supply | Precision Regulated Propane or Methane |
| Flow Control | Rotameter with ±1% Full-Scale Accuracy |
| Pressure Regulation | High-Accuracy Dual-Stage Pressure Reducer |
| Burner Types | Bunsen (ASTM D5025), Ribbon (ASTM D4986) |
| Exhaust System | Top-Mounted Forced Ventilation |
| Optional | ASTM D5207 Burner Calibration Kit |
| Standards Supported | UL 94, IEC 60695-11-10/-20, ISO 1210/9770/9772/9773, GB/T 2408/5169.17/8332 |