Q-LAB
Filter
Showing 151–180 of 281 results
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-Sun Xe-3HBSE |
| Xenon Lamp Power | 3 × 1800 W |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Q-Sun Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q-SUN Xe-8 |
| Xenon Lamp Power | 1.8 kW |
| Irradiance Range | 0.25–1.3 W/m² (at 340 nm) |
| Light Cycle | Programmable |
| Humidity Range | 10–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Cooling Method | Air-Cooled Xenon Arc Lamp |
| Lamp Life | 1500 hours (warranty) |
| Spectral Range | 295–800 nm (full-spectrum solar simulation) |
| Irradiance Control | SOLAR EYE® closed-loop feedback system |
| Temperature Monitoring | Black Panel Thermometer (BPT) or Black Standard Thermometer (BST) |
| Humidity Control | Available on Xe-2 and Xe-3 models |
| Water Spray | Programmable pure-water spray (optional, operable in light/dark cycles) |
| Filter Options | Daylight (F/Q/B), Window Glass (Q/B/SL/SF-5/IR), Extended UV (Q/B, Quartz) |
| Sample Mounting | Flat-bed (Xe-1/Xe-3) or Rotating Vertical Drum (Xe-2) |
| Compliance | Preconfigured test protocols for ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, IEC 60068-2-9, GMW 14124, VW PV 3929, and others |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Range | 20–95% RH (model-dependent) |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Filter Options | Daylight, Window Glass, Extended UV |
| Black Panel Temperature Range | 45–120 °C (varies by model and filter) |
| Sample Capacity | Up to 55 specimens (Xe-3 HD/HS models) |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, IEC 60068-2-9, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Cycle | 1–9999 h, continuously adjustable |
| Humidity Control Range | 10–95% RH (model-dependent) |
| Cooling Method | Air-cooled xenon lamps |
| Lamp Life | ~1500 hours |
| Compliance | ASTM G151, G154, ISO 4892-2, SAE J2412, IEC 60068-2-5, FDA 21 CFR Part 11 (software-enabled configurations), GLP/GMP-ready audit trails |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Series |
| Pricing | Available Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-1 / Xe-3 / B02 |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 85 °C (operational, dependent on irradiance and humidity settings) |
| Humidity Range | 10–95% RH (controlled, model-dependent) |
| Lamp Life | ~1500 hours |
| Cooling Method | Air-cooled |
| Filter Types | Daylight, Window Glass, Extended UV |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Xenon Lamp Power | 1.8 kW |
| Irradiance Range | 0.25–1.3 W/m² (at 340 nm) |
| Light Cycle | Programmable |
| Humidity Range | 10–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Xenon Lamp Power | 1800 W |
| Irradiance Control | 1.3 W/m² @ 340 nm |
| Max Exposure Duration | 1500 h per cycle |
| Humidity Range | Up to 95% RH |
| Compliance | GB/T 1865–2009 Cycle A Method 1 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-SUN® Xe-8 |
| Price | Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-UV |
| Type | UV Aging Test Chamber |
| Light Source | Fluorescent UV Lamps (UVA-340, UVB-313, or Cool White as configurable) |
| Irradiance Control | Optional SOLAR EYE® feedback-controlled system (standard on Q-UV/se, Q-UV/spray, Q-UV/cw |
| Condensation Mechanism | Water jacketed chamber wall condensation |
| Spray System | Optional on Q-UV/spray (deionized water only) |
| Temperature Range | Black Panel Temperature: 35–80 °C (95–176 °F) |
| Chamber Air Temperature | 25–80 °C (77–176 °F) |
| UV Wavelength Range | UVA-340 (300–400 nm, peak at 340 nm) |
| Internal Chamber Dimensions (L×W×H) | 110 × 105 × 45 cm (43.3 × 41.3 × 17.7 in) |
| Volume | 51 L (1.8 ft³) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, JIS D0205, GB/T 14522, MIL-STD-810G Method 506.6 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QCT |
| Temperature Range | Ambient to 72 °C |
| Sample Capacity | 62 pcs of 75 × 150 mm panels or 48 pcs of 100 × 150 mm panels |
| Condensate Generation | Continuous cold-surface condensation |
| Drying System | Heated forced-air circulation |
| Cycle Programming | 24-hr timer, up to 96 programmable 15-minute stages per day |
| Water Supply | 6 mm plastic tubing, ~2 L/day consumption |
| Compliance | Designed for ASTM D4585, ISO 6270-2, and JIS D0205 environmental corrosion testing protocols |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-Lab QCT |
| Pricing | Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | QCT |
| Price Range | USD 25,000 – 65,000 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV |
| Type | UV Aging Test Chamber |
| Light Source | Fluorescent UV Lamps (UVA-340, UVB-313, or UVA-351) |
| Condensation System | Yes |
| Water Spray System | Optional (QUV/spray, QUV/se) |
| Irradiance Control | Yes (via calibrated sensor & feedback loop) |
| Black Panel Temperature Range | 40–80 °C |
| Chamber Temperature Range (Condensation) | 40–60 °C |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Power Supply | 120/230 V, 50/60 Hz, up to 1800 W |
| Water Consumption | 8 L/day (condensation), 7 L/min (spray, peak) |
| Lamp Life | 1600–5000 h (model-dependent) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, IEC 61215, MIL-STD-810, FDA 21 CFR Part 11 (with optional software) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV |
| Test Duration | 1–5000 h |
| Irradiance Range | 10 W/m² |
| UV Wavelength Range | 295–400 nm (configurable via lamp type) |
| Black Panel Temperature Range | 35–80 °C |
| Chamber Humidity Range | 10–100 % RH (condensation cycle enabled) |
| Illuminated Chamber Volume | 65 L (L×W×H: 114 × 45 × 127 cm) |
| Lamp Type Compatibility | UVA-340, UVA-351, UVB-313EL, QFS-40 |
| Brand | Q-LAB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV (Imported from USA) |
| Quotation | Upon Request |
| Illuminant Temperature Range (°C) | Configurable per test standard |
| Black Panel Temperature Range (°C) | 35–80 °C (typical operating range) |
| UV Wavelength Range (nm) | 295–400 nm (selectable via lamp type: UVA-340 or UVB-313) |
| Chamber Dimensions (L×W×H) | 1100 × 500 × 420 mm (standard QUV se model) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | QUV |
| Pricing | Upon Request |
| Exposure Time | Programmable |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | Programmable |
| Black Panel Temperature Range | Consult Technical Support |
| Chamber Temperature Range (°C) | Consult Technical Support |
| UV Wavelength Range | 320–400 nm |
| Internal Chamber Dimensions (L×W×H) | Consult Technical Support |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV UV Aging Test Chamber |
| Illumination Temperature Range | 35–80 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV (Imported) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, DIN 75220, GB/T 14522 |
| Lamp Options | UVB-313EL, UVA-340, UVA-351, FS-40, CW (QUV/CW & QUV/Basic only) |
| Sample Capacity | Two 75 mm × 150 mm (3″ × 6″) panels per rack |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Chamber Construction | Stainless steel interior, corrosion-resistant exterior |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV Accelerated Weathering Tester |
| Quotation | Available Upon Request |
| UV Wavelength Range | 320–400 nm (UVA/UVB) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Lamp Life | ≥5,000 hours |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522, JIS D 0205 |
| Control System | Radiant Power Closed-Loop Feedback, Self-Diagnostic Alarms, Maintenance Reminders |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV Accelerated Weathering Tester |
| Price | Upon Request |
| UV Wavelength Range | 280–340 nm |
| Sample Chamber Dimensions (L×W×H) | Available Upon Request |
| Illumination Temperature Range | Available Upon Request |
| Black Panel Temperature Range | Available Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se / QUV/spray / QUV/cw / QUV/basic |
| UV Lamp Options | UVA-340 (295–365 nm), UVA-313 (250–370 nm) |
| Black Panel Temperature Range | 40–80 °C |
| Condensation Temperature Range | 40–60 °C |
| Chamber Dimensions (L×W×H) | Varies by model |
| Sample Capacity | Up to 50 specimens (75 × 150 mm) |
| Power Supply | 120/230 V, 50/60 Hz, up to 1800 W |
| Water Consumption | 8 L/day (condensation), 7 L/min (spray) |
| Lamp Lifetime | 1600–5000 h (model-dependent) |
| Compliance | ISO 4892-3, ASTM G154, ASTM D4329, SAE J2020, IEC 60068-2-5 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV |
| UV Wavelength Range | 280–400 nm |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, IEC 61215 (UV preconditioning), FDA 21 CFR Part 11 (software-enabled configurations) |
| Sample Capacity | Up to 48 specimens (75 × 150 mm) |
| Power Supply | 230 V ±10%, 50/60 Hz, max. 2000 W |
| Water Requirements | Deionized or tap water (pH 6.0–8.0), 2–80 psi, ~8 L/day for condensation cycle |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV |
| UV Wavelength Range | 280–400 nm |
| Spectral Options | UVA-340 (295–365 nm), UVB-313 (peak at 313 nm) |
| Condensation Method | Water-cooled cold mirror condensation cycle |
| Control System | Solar Eye irradiance feedback control |
| Compliance | ISO 4892-3, ASTM G154, IEC 60068-2-5, AATCC TM186, SAE J2020 |
| Connectivity | Ethernet-enabled with remote monitoring capability |
| Calibration | CR10-compatible, traceable to NIST standards |
| Sample Mounting | Clip-in rack system for standardized specimen holders |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV |
| UV Wavelength Range | 280–400 nm |
| Compliance | ASTM G154, ISO 11507, ASTM D4329, JIS D0205, SAE J2020, AATCC TM186, ISO 4892-3 |
| Light Source Options | UVA-340 (sunlight-simulating), UVB-313 (enhanced degradation), UVC (for specialized disinfection or polymer studies), Cool White Fluorescent (QUV/cw) |
| Irradiance Control | SOLAR EYE® feedback-controlled system (standard on QUV/se, QUV/spray, QUV/cw) |
| Condensation Mechanism | Refrigerated cold-wall condensation |
| Optional Features | Water Spray (QUV/spray), Visible Light Exposure (QUV/cw), Programmable Cycles (UV/condensation/spray/dark), Digital Touchscreen Interface, GLP/GMP Audit Trail Support (via Q-Lab’s QUV Software Suite) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV Advanced |
| UV Wavelength Range | 320–400 nm (UVA-340/UVB-313 spectral options) |
| Black Panel Temperature Range | 35–80 °C |
| Irradiance Control | SOLAR EYE® closed-loop feedback system |
| Chamber Dimensions | Custom-configurable (standard internal volume: 160 L) |
| Lamp Life | ≥5,000 hours |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, DIN 75220, BS EN 1062-5 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV |
| Irradiance Range | Adjustable |
| UV Lamp Power | Adjustable |
| Humidity Range | Adjustable |
| Black Panel Temperature Range | Up to 80 °C |
| UV Wavelength Options | UVA-340, UVB-313, UVC (IEC-compliant), Cool White |
| Chamber Dimensions | Custom Configurations Available |
| Test Duration | Programmable |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se / QUV/spray / QUV/basic / QUV/cw / QUV/uvc |
| UV Lamp Options | UVA-340, UVB-313EL+, UVA-351, UVC-254, Cool White |
| Irradiance Control | Closed-loop Solar Eye® system (QUV/se, QUV/spray, QUV/uvc, QUV/cw) |
| Condensation Cycle | 40–60 °C, duration programmable |
| UV Exposure Temperature Range | 45–80 °C (QUV/se, QUV/spray) |
| Sample Capacity | Up to 50 specimens (75 × 150 mm) |
| Chamber Dimensions (W×H×D) | 137 × 135 × 53 cm |
| Weight | 136 kg |
| Power Supply | 120 V ±10%, 1φ, 60 Hz, 14–16 A or 230 V ±10%, 1φ, 50/60 Hz, 7–8 A |
| Lamp Life | 8,000 h (standard irradiance) |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, ISO 4892-1, JIS D0205, SAE J2020, IEC 60335-1, IEC 61215-2, USP <661>, FDA 21 CFR Part 11 (via optional software audit trail), GLP/GMP-ready data logging |