| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DMA 850 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 to 600 °C |
| Force Range | 0.0001–18 N |
| Resolution (Displacement) | 0.1 nm over 25 mm travel |
| Bearing Type | Frictionless air bearing |
| Actuation | Non-contact lightweight motor |
| Control Technology | DirectStrain™, Auto-Ranging |
| Cooling | Integrated mechanical refrigeration (down to –100 °C without LN₂) |
| Software | TRIOS™ |
| Warranty | 5-year furnace warranty |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 55 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | <25 μg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 3200 Series |
| Frequency Range | 0.0001 – 300 Hz |
| Force Capacity Options | ±225 N or ±450 N (standard) |
| Optional Torsion Motor | 14 N·m or 25 N·m |
| Optional Linear Extension | +150 mm stroke |
| Encoder Resolution | High-resolution optical encoder (torsion mode, up to 62 revolutions) |
| Environmental Compatibility | Integrated with temperature chambers, saline baths, and bioreactors |
| Sensor Range | ±0.002 N to ±450 N (interchangeable load cells) |
| Drive Type | Direct-drive linear electromagnetic motor |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 5500 |
| Frequency Range | 0.0001 – 20 Hz |
| Force Control Range | ±0.002 N to ±200 N |
| Architecture | Single-Beam Open-Frame Design |
| Environmental Compatibility | Compatible with Incubators & Gloveboxes |
| Optional Fixture | 24-Well Compression Fixture for Multi-Specimen Testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Nano ITC |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 0.19 mL (low-volume) |
| Thermal Control | Solid-state Peltier heating/cooling |
| Injection System | Removable syringe with high-precision stepper motor drive |
| Software | ITCRun and NanoAnalyze™ |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA elite |
| Drive Type | Direct-drive motor with high-resolution strain control |
| Torque Sensor | Patented high-stiffness, wide-range sensor with low noise floor |
| Frame Stiffness | Ultra-rigid monolithic frame eliminating instrument compliance |
| Temperature Control | Integrated gas-cooling unit for rapid and stable thermal regulation |
| Pressure Control | Pneumatically actuated, user-adjustable die closure pressure |
| Automation | Optional robotic autosampler for unattended operation |
| Calibration | User-performed torque and geometry calibration |
| Compliance | Designed to support ASTM D6204, ISO 6673, and ISO 10985 test methods |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA Flex |
| Drive Type | High-Resolution Direct-Drive Motor |
| Torque Sensor | Patented High-Stiffness, Wide-Range Transducer |
| Frame | Ultra-Rigid Monolithic Structure |
| Control | Fully Programmable Strain, Frequency, Temperature, Time, and Mold Closure Pressure |
| Automation | Integrated Robotic Sample Handler |
| Mold Closure | Pneumatically Actuated, Adjustable Pressure Disc |
| Calibration | User-Executable with Replaceable Die Plates |
| Upgrade Path | Field-Upgradeable to Extended Frequency and Strain Range |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Affinity ITC / ITC Auto |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 190 µL (low-volume) |
| Sample Throughput | Multi-sample via integrated 96-well autosampler |
| Temperature Control | Active solid-state heating/cooling with ±0.01 °C stability |
| Automation Level | Fully automated titration, injection, cleaning, and cell positioning |
| Compliance | Designed for GLP/GMP environments |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | AHT |
| Application | Continuous Shore A Hardness Testing of Vulcanized Rubber |
| Sample Capacity | 20-position (upgradable to 30) automated sample carousel |
| Control | Fully software-driven test setup, data acquisition, and pass/fail evaluation |
| Compliance | ASTM D2240, ISO 7619-1, DIN 53505 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ARES-G2 |
| Instrument Type | Rotational Rheometer |
| Sample Type | High-Viscosity & Solid-State Materials |
| Motor Bearing | Sapphire Air Bearing |
| Temperature Range | −40 °C to 180 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 1 × 10⁻⁷ to 628 rad/s |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 801 / DIL 801L |
| Configuration | Horizontal, single-sample dilatometer |
| Operating Atmosphere | Air, vacuum, or inert gas (N₂, Ar) |
| Temperature Range | −150 °C to 1600 °C (dependent on furnace and sensor option) |
| Force Control | User-adjustable contact force from 0.02 N to 1.00 N |
| Sensor Type | High-stability LVDT with digital signal conditioning |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045-1, USP <671> |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 802/802L |
| Measurement Principle | True Mechanical Differential Expansion Detection |
| Sensor Type | High-Stability LVDT with Digital Amplification |
| Contact Force Range | 0.02–1.00 N (User-Adjustable) |
| Configuration | Convertible Between Differential and Single-Sample Modes |
| Thermal Uniformity | Optimized Horizontal Furnace Design |
| Vibration Resistance | Integrated Mechanical Isolation Architecture |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 803/803L |
| Configuration | Dual-sample horizontal dilatometer with differential capability |
| Sensor Type | High-stability LVDT with digital amplifier |
| Contact Force Range | User-adjustable from 0.02 N to 1.00 N |
| Furnace Compatibility | Interchangeable TA furnace modules |
| Operating Mode | Simultaneous dual-sample or differential (sample vs. inert reference) |
| Compliance | Designed for ASTM E228, ISO 11359-2, and USP <640> thermal expansion testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 805 |
| Temperature Range | −150 to 1300 °C |
| Maximum Heating Rate | ≤4000 °C/s |
| Measurement Resolution | 0.01 µm / 0.05 °C |
| Atmosphere Options | Air, Vacuum, Inert Gases (e.g., Ar, N₂, He) |
| Quench Medium | High-velocity Helium Gas |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 806 |
| Measurement Principle | Non-contact shadow-edge optical imaging |
| Light Source | High-intensity GaN LED with collimated short-wavelength planar illumination |
| Detection | High-resolution CCD sensor with digital edge detection |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | 1400 °C → 50 °C in ≤10 min |
| Furnace Design | Dual-zone planar heating (top + bottom) for minimized axial and radial thermal gradients |
| Sample Area | 30 mm wide field-of-view with position-insensitive measurement |
| Compliance | ASTM E228, ISO 11359-1, USP <632>, GLP/GMP-ready data audit trail (via TRIOS software) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 821 / DIL 822 |
| Measurement Principle | Contact-based linear thermal expansion measurement using optical encoder and linear motor actuation |
| Resolution | 1 nm |
| Configuration | Vertical sample orientation |
| Force Control | Constant low-force contact via linear motor |
| Differential Capability | True differential measurement (DIL 822 only) |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045 |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 831 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm (standard), 12 mm (optimal) |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.03 × 10⁻⁶ K⁻¹ |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 832 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm |
| Sample Diameter | ≤6 mm |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.01 × 10⁻⁶ K⁻¹ |
| Total Measurement Range | 5000 µm |
| Cooling Time (1000 °C → RT) | 13 min |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Precision Air Bearing |
| Temperature Range | -10 to 200 °C |
| Frequency Range | 10⁻⁴ to 628 rad/s |
| Minimum Angular Velocity | 10⁻⁴ rad/s |
| Maximum Angular Velocity | 300 rad/s |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 10 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Compliance | ASTM D4065, ASTM D7028, ISO 6721, ISO 11359, USP <1031> |
| Cooling Range | –100 °C to 600 °C |
| Force Range | 0.1 mN to 18 N |
| Displacement Resolution | 0.1 nm over 25 mm dynamic range |
| Environmental Options | Dual configurable environmental chambers (inert gas, humidity, vacuum) |
| Control Architecture | Non-contact voice-coil motor with continuous force control |
| Bearing System | Low-compliance air bearing |
| Strain Sensing | Direct optical encoder-based strain measurement |
| Software Platform | TRIOS v5.x with 21 CFR Part 11 compliant audit trail and GLP/GMP-ready workflows |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| Temperature Precision | ±0.01 °C |
| DSC Heat Flow Range | ±500 mW |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 250 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Precision | ±0.008 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Capacity | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without liquid nitrogen) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 2500 |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | –180 °C to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Throughput | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without LN₂) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25P |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –130 °C to 550 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Pressure Range | 1 Pa to 7 MPa (0.0001–1,000 psi) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC2500 |
| Temperature Range | –180 to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Baseline Flatness (–50 to 300 °C) | <5 μW |
| Baseline Repeatability (–50 to 300 °C) | <10 μW |
| Enthalpy Accuracy | ±0.04 % |
| Heating/Cooling Rate | 0.1–100 K/min |
| Modulated DSC | Standard |
| Tzero® Technology | Advanced (T4P) |
| Direct Cp Measurement | Supported |
| User-Replaceable Furnace | Yes |
| 54-Position Autosampler | Standard |
| Dual-Gas Delivery Module | Standard |
| Color Touchscreen Interface | Standard |
| Optical Accessory Compatibility | Optional |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery HP-TGA 75 / 750 / 7500 |
| Temperature Range | Up to 1100 °C |
| Balance Sensitivity | 0.1 µg |
| Operating Environment | Controlled High-Pressure Atmosphere (up to 75, 750, or 7500 psi) |
| Instrument Type | Benchtop Integrated High-Pressure TGA System |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Discovery HR 30 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.05 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 10 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 20 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF-1200 |
| Temperature Range | RT to 1200 °C |
| Laser Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10⁻³ torr) |
| Detection | Liquid Nitrogen-Cooled IR Detector |
| Heating System | Resistive Furnace |
| Measurement Principle | Laser Flash Analysis (LFA) |