TA Instruments
Filter
Showing 31–60 of 66 results
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery SDT 650 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1500 °C |
| Temperature Stability | ±2% |
| Maximum Sample Mass | 200 mg |
| Base Pressure | 50 μTorr |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 550 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | <25 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 5500 |
| Temperature Range | Ambient to 1200 °C |
| Balance Sensitivity | < 0.1 µg |
| Heating/Cooling Rate | 0.1 to 500 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | < 10 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 RH |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TMA 450 |
| Temperature Range | −150 to 1000 °C |
| Temperature Accuracy | ±1 °C |
| Force Range | 0.001–2 N |
| Frequency Range | 0.01–2 Hz |
| Displacement Resolution | 15 nm |
| Maximum Sample Length | 26 mm |
| Displacement Range | ±2.5 mm |
| Cooling Option | Mechanical Cooling Accessory (MCA 70) to −70 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery X3 DSC |
| Sample Capacity | Up to 3 simultaneous samples |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | –180 °C to 550 °C |
| Temperature Accuracy | ±0.025 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DXF-200 / DXF-500 / DXF-900 |
| Measurement Principle | Laser Flash Method (Xenon Lamp-Based) |
| Maximum Sample Diameter | 25 mm |
| Pulse Width | 400–600 µs |
| Optical System | Reflective, Multi-Faceted Light Guide |
| Temperature Range Options | Up to 200 °C / 500 °C / 900 °C (Model-Dependent) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF 1600 |
| Measurement Principle | Laser Flash Method (LFA) |
| Maximum Operating Temperature | 1600 °C |
| Laser Pulse Energy | 1.35 J (Nd:Glass) |
| Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10 Torr) |
| Furnace Heating Element | MoSi₂ |
| Insulation | High-Purity Alumina Hot Zone |
| Sample Capacity | Up to 6 positions with rotating carousel |
| Detector | Liquid Nitrogen-Cooled Infrared Detector |
| Beam Delivery | Patented Fiber-Optic Light Pipe (99% uniform transmission) |
| Compliance | ASTM E1461, ISO 22007-4, DIN EN 821-2 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DLF 2800 |
| Instrument Principle | Laser Flash Method (LFA) |
| Dimensions (L×W×H) | 12.7 × 12.7 × 6 cm |
| Accuracy | ±2.3% |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Repeatability | ±2% |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DSC-25 |
| Temperature Range | –180 °C to 725 °C |
| Baseline Flatness (–50 °C to 300 °C) | ≤100 µW |
| Baseline Repeatability (–50 °C to 300 °C) | <40 µW |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.01 °C |
| Enthalpy Accuracy | ±0.1% |
| Operational Age | 2 years |
| Condition | Fully Functional |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DTC-300 |
| Measurement Principle | Guarded Heat Flow Method (ASTM E1530) |
| Sample Temperature Range | −40 °C to 200 °C (with optional chiller and heater modules) |
| Thermal Resistance Range | Three interchangeable sensor modules covering low-, medium-, and high-resistance regimes |
| Sample Form Compatibility | Solids, thin films (multi-layer stack), pastes, liquids (with custom containment) |
| Compliance | ASTM E1530, ISO 8301, EN 12667 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DuraPulse |
| Instrument Type | Dynamic Mechanical Durability Tester for Cardiovascular Devices |
| Compliance | ISO 5840-1:2021, ISO 5840-2:2021, ISO 5840-3:2021 |
| Test Stations | Configurable as 2-, 4-, or 6-channel modular units |
| Actuation Principle | Electromagnetic linear motor with closed-loop digital servo control |
| Waveform Fidelity | ≤ ±0.5% deviation from target physiological waveform (e.g., sinusoidal, pulsatile, or patient-specific waveforms) |
| Environmental Control | Independent, sealed test chambers with integrated temperature and fluid medium monitoring |
| Warranty | 10-year limited warranty on linear motor assemblies |
| Software Platform | DuraPulse Control Suite v4.x with audit trail and 21 CFR Part 11–compliant user access controls |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3200 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / Dynamic Mechanical Thermal Analyzer (DMTA) |
| Temperature Range | −150 °C to +315 °C |
| Temperature Accuracy | ±0.3 °C |
| Force Range | ±225 N (optional ±450 N) |
| Displacement Range | ±6.5 mm |
| Frequency Range | 10⁻⁵ Hz to 300 Hz |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3330 |
| Instrument Type | Dynamic Mechanical Tester (DMA/DMTA-Compatible Platform) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | ±3000 N |
| Maximum Dynamic Torque (with optional torsion module) | 28 N·m |
| Configuration Options | Benchtop or Floor-standing |
| Power Requirement | Standard 220 V AC outlet |
| Pneumatic Interface | Compressed air supply required |
| Structural Design | Rigid dual-column beam architecture |
| Vertical Stroke Adjustment | Integrated pneumatic/electric/manual lift mechanism |
| Multi-Axis Capability | Optional torsion motor for axial-torsional coupling |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3450 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / DMTA |
| Force Range | ±3 kN (standard), ±6 kN (high-load option) |
| Displacement Range | up to ±22 mm |
| Frequency Range | 0.0001 Hz to 200 Hz |
| Temperature Range | –150 °C to 300 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3500 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Frequency Range | 0.00001–100 Hz |
| Maximum Dynamic Load | 7.5 kN (standard), 15 kN (optional) |
| Dynamic Stroke | 50 mm |
| Cooling | Air-cooled |
| Motor Mounting Options | Upper Crosshead (3510), Base-Mounted (3520), High-Load Configuration (3550) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ElectroForce |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Control | Physiological Saline Bath |
| Loading Mode | Displacement-Controlled Tension-Tension or Compression-Compression |
| Sample Capacity | Multiple Independent Test Stations |
| Cycle Resolution | High-Resolution Linear Encoder-Based Displacement Measurement |
| Compliance | Designed for ISO 14242-1, ASTM F2129, and FDA Guidance for Cardiovascular Implant Fatigue Testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 3300 |
| Frequency Range | 0.0001 – 100 Hz |
| Load Capacity Options | ±1000 N or ±3000 N (axial) |
| Torsion Options | ±14 N·m or ±25 N·m |
| Linear Stroke Extension Option | +150 mm |
| Force Resolution | ±0.02 N to ±3000 N |
| Drive Type | High-Performance Linear Electromagnetic Motor |
| Encoder Resolution | High-Resolution Optical Encoder (up to 62 revolutions for torsion) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TestBenches |
| Load Capacity Options | 200 N or 400 N |
| Configuration | Planar Biaxial TestBench with Integrated Digital Video Extensometry |
| Distribution Type | Authorized Distributor (Imported Equipment) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 HT |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 to 250 °C |
| Minimum Sample Thickness | 0.025 mm |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 200 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Repeatability | ±0.5% |
| Accuracy | ±1% |
| Temperature Range | −20 °C to +75 °C |
| Minimum Sample Thickness | 0.025 mm |
| Compliance | ASTM C518, ISO 8301 |
| Control Modes | Standalone or PC-controlled |
| Software | WinTherm™ |
| Optional Automation | Robotic Auto-sampler |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 314 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.005–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | Standard –20°C to 75°C |
| Thickness Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Software | WinTherm™ v5.x |
| Automation | Optional AutoSampler for unattended operation |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 50 |
| Thermal Conductivity Range | 0.1–10 W/m·K |
| Dimensions (L×W×H) | 250×170×360 mm |
| Accuracy | ±3% |
| Temperature Range | −10°C to 110°C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 GHP |
| Measurement Principle | Guarded Hot Plate (GHP) |
| Compliance Standards | ASTM C177, ISO 8302, DIN EN 12667 |
| Operating Temperature Range | 90 °C to 250 °C |
| Sample Configuration | Single-specimen, symmetric arrangement |
| Thickness Measurement Method | Optical encoder-based digital displacement sensing |
| Temperature Uniformity Verification | 40 matched thermocouples |
| Thermal Stability Architecture | Dual-zone active temperature control with inert gas purge capability |
| Instrument Class | Primary-standard absolute thermal conductivity measurement system |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 600 |
| Measurement Principle | Guarded Hot Plate / Heat Flow Meter Method (ASTM C518, ISO 8301) |
| Sample Thickness Range | Down to 0.025 mm (with digital thickness measurement) |
| Sensor Type | Dual thin-film heat flux sensors |
| Temperature Control | Responsive solid-state heating/cooling system |
| Software | WinTherm™ (compliant with 21 CFR Part 11 audit trail & user access control) |
| Automation Options | Optional auto-sampler and rotary sample stage |
| Compliance | ASTM C518, ISO 8301, ISO 8302 (guarded hot plate mode), GLP/GMP-ready configuration |
| Brand | TA Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FOX 801 |
| Price | Upon Request |
| Thermal Conductivity Range | 0.001–0.35 W/m·K |
| Accuracy | ±1% |
| Temperature Range | −10 to +65 °C |
| Thickness Measurement Resolution | 0.025 mm |
| Sensor Type | Dual Thin-Film Heat Flux Sensors |
| Compliance | ASTM C518, ISO 8301 |
| Cooling/Heating Method | Solid-State Peltier |
| Control Mode | Standalone or PC-Driven (WinTherm Software) |
| Optional Accessories | Automated Sample Changer, Rotational Sample Holder |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MDR one |
| Compliance | ASTM D5289, ISO 6502, DIN 53529-1 |
| Temperature Control Range | Ambient to 200 °C (standard), optional refrigeration unit for sub-ambient testing |
| Torque Measurement Range | 0.001–10 N·m |
| Angular Displacement Resolution | ≤ 0.001° |
| Drive System | Direct-drive servo motor |
| Frame Stiffness | > 10⁶ N/m |
| Sample Geometry | Sealed dual-cone die (standard), interchangeable with oscillating disk or rotorless rectangular dies |
| Automation | Optional robotic sample handler with pneumatic die clamping |
| Software | Scarabaeus v5.x (multi-language UI, 21 CFR Part 11-compliant audit trail, raw data export in ASTM E1382-compliant format) |
| Calibration | User-performed torque and temperature calibration with NIST-traceable reference standards |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MV one |
| Motor Speed Range | 0.1–10 rpm (standard test at 2 rpm) |
| Rotor Options | 38.10 mm (large) and 30.48 mm (small) diameter |
| Compliance | ASTM D1646, ISO 289, DIN 53523 |
| Temperature Control | High-precision, PID-regulated, ±0.1 °C stability |
| Torque Measurement | Auto-calibrating, high-resolution digital torque sensor |
| Frame | Ultra-rigid monolithic steel construction |
| Drive System | Direct-drive brushless motor with <0.01 rpm speed resolution |
| Software | Scarabaeus v5.x (multi-language, GLP-compliant audit trail, FDA 21 CFR Part 11 ready) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Cell Volume | < 200 µL (capillary-based) |
| Pressure Control | Integrated solid-state linear actuator with ±0.1 psi regulation |
| Automation | Optional DSC Auto autosampler (HPLC-grade precision) |
| Brand | TA Instruments |
|---|---|
| Origin | Italy |
| Model | OPD 868 |
| Temperature Range | RT – 1650 °C |
| Heating Rate | 0.1 – 100 °C/min (up to 200 °C/sec in transient mode) |
| Temperature Accuracy | ±0.2 °C |
| Sample Length | 1 – 85 mm (mode-dependent) |
| Camera Resolution | 5 MP |
| Multi-sample Capability | Up to 8 ISO-standard specimens simultaneously |