Environmental Monitoring Instruments
Filter
Showing 3541–3570 of 9112 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ≤1.0% FS |
| Repeatability | ≤1.0% FS |
| Response Time (T90) | ≤45 s (SO₂ ≤180 s) |
| Stability | ≤2.0% FS/2 h |
| Measured Gases | SO₂, NO, CO, O₂, CO₂ (optional CH₄) |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-time Trend Plotting |
| Data Storage | SD Card (user-configurable interval) |
| Output Interfaces | 4–20 mA analog, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ±2.0% FS |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s for NOₓ, CO, CO₂, O₂ |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Warm-up Time | 30 min |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT LCD with Touch Interface |
| Data Storage | Removable SD Card |
| Output | 4–20 mA DC analog output, Ethernet interface |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Target Gases | NOx, SO₂, CO, CO₂, O₂ |
| Measurement Ranges | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges), SO₂: 0–200/500/1000/3000 ppm (4 ranges), CO: 0–200/500/1000/2000/5000 ppm (5 ranges), CO₂: 0–10/20/30 vol%, O₂: 0–5/10/25 vol% |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Data Storage | SD card (user-configurable interval) |
| Output | 4–20 mA analog, Ethernet |
| Preheat Time | 30 min (±2.0% F.S. stability within 2 h) |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measurable Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5/10/25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226(W) × 265(H) × 510(D) mm |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Measurement Ranges | NOₓ: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% |
| O₂ | 0–5/10/25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA DC, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Target Gases | NOx, SO₂, CO, CO₂, O₂ |
| Measurement Principle | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOx: 0–2500 ppm (7 ranges), SO₂: 0–3000 ppm (4 ranges), CO: 0–5000 ppm (5 ranges), CO₂: 0–30 vol% (3 ranges), O₂: 0–25 vol% (3 ranges) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA, Ethernet |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS/MIAC (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ (5-component simultaneous analysis) |
| Range Options | CO₂: 0–5/10/25 vol% |
| O₂ | 0–5/10/25 vol% |
| Repeatability | ±1.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Zero/Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Preheat Time | 30 min (±2.0% F.S. stability achieved within 2 h) |
| Compliance | MCERTS (UK), TÜV (EU), GOST-R (Russia), ETV (USA), China Metrology Certification, KORELMA (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measurable Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% |
| O₂ | 0–5/10/25 vol% |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| SO₂ | ≤180 s |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~14 kg |
| Dimensions (W×H×D) | 226 × 265 × 510 mm |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, Korea KOLAS, Japan JIS/MI |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOx, SO₂, CO, CO₂, O₂ |
| Measurement Principle | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% (3 ranges) |
| O₂ | 0–5/10/25 vol% (3 ranges) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Target Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Measurement Ranges | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂), ≤180 s (SO₂) |
| Zero/Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT touchscreen with real-time trend graphs and step-by-step on-screen guidance |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), China Metrology Certification (CMC), Korea Metrology Certification, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (±2.0% FS/day for SO₂) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (≤180 s for SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | PG-300 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Measurement Principles | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOₓ: 0–25 to 2500 ppm (7 ranges) |
| SO₂ | 0–200 to 3000 ppm (4 ranges) |
| CO | 0–200 to 5000 ppm (5 ranges) |
| CO₂ | 0–10 to 30 vol% |
| O₂ | 0–5 to 25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min (±2.0% F.S. stabilized within 2 h) |
| Display | Color TFT LCD with touch interface, real-time trend curves, step-by-step on-screen guidance |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Environmental Operating Conditions | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), China Metrology Certification (CMC), Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Detection Principle | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% (3 ranges) |
| O₂ | 0–5/10/25 vol% (3 ranges) |
| CH₄ (optional) | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Certifications | TÜV (EU), MCERTS (UK), GOST (Russia), ETV (US), China Metrology Certification (CMC), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (for CO₂ and O₂) |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s (all gases except SO₂: ≤180 s) |
| Zero/ Span Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity Error | ±2.0% FS |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color LCD touchscreen with real-time trend plotting |
| Data Storage | SD card (user-configurable interval) |
| Output | 4–20 mA analog, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 (PG-300 Series) |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, Korea KOLAS, Japan JIS/MI |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), ETV (US), China Metrology Certification, KOLAS (Korea), JIS (Japan) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Preheat Time | 30 min (±2.0% F.S. stability achieved within 2 h) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, KR KOLAS, JP JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ |
| Measurement Principle | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOₓ: 0–25 to 2500 ppm (7 ranges) |
| SO₂ | 0–200 to 3000 ppm (4 ranges) |
| CO | 0–200 to 5000 ppm (5 ranges) |
| CO₂ | 0–10 to 30 vol% |
| O₂ | 0–5 to 25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), China Metrology Certification (CMC), Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% (3 ranges) |
| O₂ | 0–5/10/25 vol% (3 ranges) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Display | Color TFT LCD with touch interface |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), ETV (US), China Metrology Certification, KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOx, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | UK MCERTS, EU TÜV, US EPA ETV, China CMA, Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (all gases except SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, KR KOLAS, JP JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Minimum Range | 0–5/10/25 vol% (O₂/CO₂) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Zero/ Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-Time Trend Plotting |
| Data Storage | SD Card (User-Configurable Interval) |
| Output | 4–20 mA DC, Ethernet |
| Warm-up Time | ≤30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-Time Trend Plotting |
| Data Storage | SD Card (User-Configurable Interval) |
| Output Interfaces | 4–20 mA DC, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Range Options | NOₓ: 0–25 to 2500 ppm (7 ranges) |
| SO₂ | 0–200 to 3000 ppm (4 ranges) |
| CO | 0–200 to 5000 ppm (5 ranges) |
| CO₂ | 0–10 to 30 vol% |
| O₂ | 0–5 to 25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| SO₂ | ≤180 s |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS/MLIT (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | O₂: 0–5/10/25 vol% |
| CO₂ | 0–5/10/25 vol% |
| Repeatability | ±1.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Zero/Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT-LCD Touchscreen with Real-Time Trend Graphs |
| Data Storage | SD Card (User-Configurable Interval) |
| Output Interfaces | 4–20 mA Analog, Ethernet |
| Warm-up Time | ≤30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | MCERTS (UK), TÜV (EU), GOST-R (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Measurement Principles | Pulsed Chemiluminescence (NOₓ), Modulated NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| T₉₀ Response Time | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PMA-51d |
| Explosion Protection | Ex d IIB+H2 T4 / Ex px d IIC T4X |
| Measurement Principle | Magnetic Mechanical (Magnetic Dumbbell Ball Method) |
| Target Gas | O₂ |
| Range Options | 0–5 vol% to 0–100 vol% O₂ |
| Repeatability | ±0.1 vol% O₂ (standard range) |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±0.05 vol% O₂/week |
| Span Drift | ±0.05 vol% O₂/week |
| Response Time (T90) | ≤20 s |
| Sample Flow Rate | 300 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Ambient Operating Temperature | –10 to +50 °C |
| Wetted Materials | SUS304, SUS316, Pt, Borosilicate Glass, FKM, SiO₂, Au |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model No. | 3200044490 |
| Instrument Type | Portable |
| Measurement Range | 0–200 mg/L (or ppm, as applicable) |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±1% of reading |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 0.5 test per minute |
| Compatible Analyzer Platform | HORIBA OCMA-300/310/350 series |
| Extraction Method | Liquid–Liquid Extraction |
| Analysis Principle (post-extraction) | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Solvent Recovery Compatibility | Yes, with HORIBA SR-305 Solvent Recovery System |