Flue Gas Analyzer
Filter
Showing 151–180 of 245 results
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA-60 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Electrochemical & NDIR (Non-Dispersive Infrared) Sensor Technology |
| Accuracy (CO) | ±5 ppm |
| Repeatability | ≤2% |
| Response Time (T90) | 45 s |
| Stability | ≤5% |
| Gas Channels | 5 standard electrochemical sensors + up to 2 additional electrochemical + 3 NDIR sensors |
| Data Storage | 1 million records (256 MB) |
| Display | 320 × 240 pixel backlit LCD |
| Printer | Integrated 57 mm dot-matrix thermal printer |
| Power Supply | 12 V / 2.2 Ah rechargeable lead-acid battery (6 h operation) or 110–220 V AC adapter |
| Dimensions (L×H×W) | 500 × 410 × 180 mm |
| Weight | 9.5 kg |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–55 °C |
| Humidity Range | 5–90% RH (non-condensing) |
| Pressure Resolution | 1 Pa (differential), 0.1 hPa (ambient, optional) |
| Temperature Inputs | 8 channels (4 thermocouples + 4 thermistors, optional) |
| Flow Control | Electronically regulated peristaltic pump (90 L/h nominal, 1.63 L/min sampling flow) |
| Sample Conditioning | Peltier-based gas dryer + heated probe (300 mm standard) + 5 µm/20 µm particulate filters |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | GA40Tplus |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Accuracy | ±5 ppm |
| Repeatability | ≤2% |
| Response Time | 45 s |
| Stability | ≤5% |
| Sensor Configuration | Up to 8 sensors (6 electrochemical + 2 infrared) |
| Analog Inputs | 6 (voltage, current, temperature) |
| Analog Outputs | 2 (optional) |
| Data Storage | 1024 records across 10 databases |
| Display | 128×112-pixel backlit LCD |
| Printer | High-speed dot-matrix, 56 mm paper |
| Power | 110/230 V AC, 50/60 Hz |
| Dimensions | 460 × 170 × 160 mm |
| Weight | 10 kg |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | PHOTON |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical Sensors |
| Accuracy | ≤3% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, CH₄, VOCs (via optional electrochemical sensors), O₂ |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (W×H×D) | 500 × 340 × 150 mm |
| Weight | ~7 kg |
| Power Supply | 90–230 VAC, 50–60 Hz |
| Display | Backlit LCD, 320 × 240 px |
| Data Memory | 65,535 records |
| Analog I/O | 8-channel configurable voltage/current input/output |
| Compliance | Designed for EN 15267, EN 14181, ISO 12039, and EPA Method 6C/7E compatibility |
| Brand | Madur |
|---|---|
| Origin | Austria |
| Model | PHOTON S |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical Sensors |
| Accuracy (Indication Error) | ≤3% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS/7 days |
| Measured Gases | SO₂, NO, NO₂, O₂, CO, CO₂ |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAMOS 100-400 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤ ±5% of reading |
| Repeatability | ≤ 2% |
| Response Time (T90) | ≤ 90 s |
| Long-Term Stability | ≤ 5% over 30 days |
| Sampling Pump Flow Rate | 1.5 L/min |
| Operating Humidity | 5–95% RH (non-condensing) |
| Ambient Temperature Range | 0–40 °C |
| Power Supply | 24 V AC |
| Power Consumption | ~8 W |
| Enclosure Rating | IP54 |
| Dimensions (H×W×D) | 380 × 300 × 140 mm |
| Weight | ~4 kg |
| Analog Outputs | 4–20 mA (linear), 0–10 V (programmable, linear) |
| Digital Interface | RS232C (TTL level) |
| Signal Averaging Time | 2–32 s (user-configurable) |
| Zero/Measurement Cycle | Fully automated, independently programmable |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100-400 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤5% FS |
| Repeatability | ≤2% FS |
| Response Time (T90) | 45 s |
| Stability | ≤5% FS over 30 days |
| Sensor Options | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, Cl₂, H₂) & NDIR (CO, CO₂, CH₄, N₂O) |
| Housing | IP54-rated ABS enclosure |
| Power Supply | 24 V AC, ~8 W |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–+55 °C |
| Dimensions (H×W×D) | 380 × 300 × 140 mm |
| Weight | ~4 kg |
| Zero/Measurement Cycle | Fully automated dual-phase sequence with independent timing control |
| Output Signals | 4–20 mA and 0–10 V per channel |
| Digital Interface | RS232 |
| NDIR Response Time | T90 < 10 s |
| Built-in Sample Conditioning | Peltier-cooled dryer, particulate filter, condensate peristaltic pump |
| Calibration | Factory-calibrated sensors |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | maMoS-100/200 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 45 s |
| Stability | ≤ 5% FS drift over 1 h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCA03 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Extractive In-Situ Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% of Full Scale |
| Repeatability | Not Specified |
| Response Time | ≤10 s |
| Stability | Not Specified |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | DELTA65S |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤±5% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Stability | ≤5% FS/8 h |
| Measured Parameters | O₂, CO, NO, CO₂, Flue Gas Temperature |
| O₂ Range | 0–21.00% vol |
| CO Range | 0–4000 ppm |
| CO (H₂-compensated) | 0–10000 ppm |
| NO Range | 0–5000 ppm |
| Flue Gas Temperature Range | −40 to +1100 °C |
| Dimensions | 82 × 169 × 44 mm |
| Weight | ~390 g |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | MGA6 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) + Electrochemical Sensors |
| Measured Gases | O₂, CO, CO₂, HC (Hydrocarbons), SO₂, NO, NO₂ |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Drift Stability | ≤ 2% FS over 24 h |
| Display | 7″ TFT Color Touchscreen (800 × 480) |
| Operating System | Embedded Linux |
| Connectivity | Bluetooth 5.0, WLAN (IEEE 802.11 b/g/n), RS485, 8-channel analog output, 4-channel analog input |
| Data Storage | Internal database with timestamped measurement logs |
| Output Formats | CSV, PDF reports |
| Compliance | EN 15267-3, EN 14181 (QAL1/QAL2), ISO 12039, ISO 10849, ASTM D6522, EPA Method 6C / 7E / 10 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | MGA6plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) + Electrochemical Sensors |
| Measured Gases | O₂, CO₂, CO, NO, SO₂, NO₂, HC (C₃H₈/CH₄), N₂O |
| O₂ Sensor Options | Paramagnetic (5-year lifespan) or Electrochemical |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Long-Term Stability | ≤ 2% FS over 30 days |
| Display | 7″ TFT Color Touchscreen (800 × 480) |
| Operating System | Embedded Linux |
| Connectivity | Bluetooth 5.0, WLAN (IEEE 802.11 b/g/n), RS485, 8× analog outputs (0–10 V / 4–20 mA), 4× analog inputs |
| Data Storage | Internal database with timestamped measurement logs |
| Reporting | CSV export, PDF report generation via MRU4U software |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, ISO 10849, and applicable EPA Method 6C/7E/8 requirements |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | NOVAcompact |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurable Gases | O₂, CO, NO, NO₂, SO₂, COhigh, Temperature, Pressure, Flow Velocity |
| Detection Principle | Electrochemical Sensors (O₂, CO, NO, NO₂, SO₂), Thermocouple (Temperature), Piezoresistive Sensor (Pressure), Pitot Tube (Flow Velocity) |
| Operating Temperature | +5 to +45 °C |
| Storage Temperature | −20 to +50 °C |
| Power Supply | Rechargeable Li-ion Battery (10 h standard / 2–3 h with Peltier cooler) |
| Weight | ~5.8 kg |
| Dimensions (W×H×D) | 423 × 240 × 176 mm |
| Ingress Protection | IP20 |
| Data Storage | 16,000 internal records + optional 2 GB SD card |
| Connectivity | USB, Bluetooth, SD card slot |
| Compliance | Designed for EN 50379-1, EN 50379-2, and applicable parts of ISO 12039, ISO 10849, VDI 3862 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | NOVAplus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ 1% FS |
| Response Time | ≤ 10 s |
| Stability | ≤ 1% FS over 8 h |
| Measurable Parameters | O₂, CO, NO, NO₂, SO₂, CO (high range), CO (very high range), H₂S, CO₂ (NDIR), Total Hydrocarbons (HC), Flue Gas Temperature, Differential Temperature, Combustion Air Temperature |
| Sensor Configuration | Up to 6 electrochemical cells + 3 NDIR channels |
| Battery Life | 20 h (main unit), 30 h (RCU) |
| Wireless Range | 20 m (obstructed) / 100 m (line-of-sight) |
| Data Storage | 16,000 records |
| Display | 3.5″ backlit color LCD |
| Connectivity | SD card slot, mini-USB port, wireless RCU link |
| Optional Accessories | Peltier cooler, peristaltic condensate pump, 5-year O₂ sensor, integrated thermal printer, leak detection module, pitot tube/rotating vane anemometer interface, humidity & barometric pressure probe |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | OMS420 |
| Response Time | < 10 s |
| Measurement Principle | ZrO₂ Electrochemical Cell |
| Optional Sensor | COe (Combustible Gas Equivalent) |
| O₂ Range | 0–25% vol |
| COe Range (optional) | 0–1000 ppm |
| Accuracy | ±0.2% O₂ or ±5% of reading (whichever is greater) |
| Repeatability | ≤ ±1% FS |
| Warm-up Time | 30 min |
| Service Life | > 5 years |
| Analog Outputs | Dual 4–20 mA (user-configurable range) |
| Digital Interface | RS485 (Modbus RTU) |
| Power Supply | 18–24 VDC / 90–100 W |
| Calibration Port | Threaded connection for 6/4 mm tubing |
| Purge Air Interface | Quick-connect fitting, 8 mm, 6–8 bar compressed air required |
| Operating Ambient Temperature (electronics) | –20 °C to +60 °C |
| Enclosure Rating | IP65 |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | OPTIMA7 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ 0.5% FS (Note: “≤0%” is technically invalid |
| Response Time | ≤ 10 s (T90) |
| Drift Stability | ≤ 1% FS/24 h |
| Measurable Parameters | O₂, CO (with H₂ compensation), COlow, NO, NOlow, NO₂, SO₂, H₂S, CO₂, Flue Gas Temperature (0–1100 °C), Ambient Air Temperature (0–100 °C), Static Pressure (±100 hPa), Differential Pressure (±100 hPa), Gas Velocity (3–100 m/s), Combustion Efficiency |
| Brand | MRU (Germany) |
|---|---|
| Origin | Germany |
| Model | VARIO plus-new |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Dual-mode — NDIR (CO₂, CO, NO, SO₂, NO₂, HC) + Electrochemical (O₂, CO, NO, SO₂, NO₂, H₂) |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 1% FS |
| Response Time (T₉₀) | ≤ 20 s |
| Drift Stability (24 h) | ≤ 1% FS |
| Measured Gases | O₂, CO₂, CO, NO, SO₂, NO₂, HC (as C₃H₈), H₂ |
| Operating System | Embedded Linux |
| Display | 7″ TFT color touchscreen (800 × 480 px) |
| Data Interfaces | Ethernet, WLAN (802.11 b/g/n), Bluetooth 4.0, USB 2.0, RS485, 8 × 4–20 mA analog outputs, 4 × 4–20 mA analog inputs, AUX port (K-type thermocouple, 0–10 V, 4–20 mA, RS485) |
| Power | Rechargeable 48 Wh Li-ion battery (typ. 6 h operation) |
| Condensate Management | Integrated Peltier cooler + automatic peristaltic condensate pump |
| Auto-Calibration | Scheduled zero calibration during continuous operation |
| Data Export | CSV/PDF reports via USB or network |
| Compliance | EN 50379-1/-2, EN 15267-3, MCERTS (UK), EPA Method 6C/7E/10, ISO 12039, ISO 10849, DIN 33430, GLP-compliant data logging with audit trail capability |
| Brand | MSR Analytical |
|---|---|
| Model | GXH-3050E |
| Origin | Beijing, China |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | NDIR (Non-Dispersive Infrared) with optional TCD, Electrochemical, and Fluorescence Detection Modules |
| Measurable Gases | CO, CO₂, CH₄, C₃H₈, HC (hydrocarbons), H₂, O₂, H₂S, SO₂, NH₃ |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ ±1% FS |
| Response Time | ≤ 60 s |
| Zero & Span Drift | ≤ ±1% FS / 48 h |
| Warm-up Time | ≤ 30 min |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% or internal 7.5 V DC Li-ion battery |
| Output Interface | RS232 serial communication |
| Sample Conditioning | Integrated probe with cooling, particulate filtration, moisture removal, and chemical scrubbing |
| Brand | NOVA |
|---|---|
| Origin | Canada |
| Model | NOVA 7900P |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) for CO/CO₂/CH₄ |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Response Time (T90) | ≤ 30 s |
| Drift (Zero & Span, 8 h) | ≤ ±0.5% FS |
| Operating Temperature | 0–50 °C |
| Dimensions | 254 mm H × 254 mm W × 356 mm D |
| Weight | ~9 kg |
| Gas Ranges (Standard) | CO: 0–25.0% vol |
| CO₂ | 0–2.00% vol |
| CH₄ | 0–10.00% vol |
| H₂ | 0–40.00% vol |
| O₂ | 0–1.00% vol (or ppm range optional) |
| Output | 0–1 V DC per gas channel |
| Power | Rechargeable Li-ion battery |
| Sampling | Integrated diaphragm pump, particulate filter, condensate trap, and flow meter |
| Compliance | Designed to support ASTM D6522, ISO 12039, EN 15267, and EPA Method 3A / 10 |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OPTIMA 7 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical Sensor (O₂, CO, NOₓ, SO₂, H₂S) |
| Accuracy | ≤ ±1% of full scale |
| Repeatability | ≤ 0.5% (typical, per ISO 12039 & EN 15267-3) |
| Response Time (T₉₀) | ≤ 10 s |
| Drift Stability | ≤ 1% FS/week |
| Measurable Gases | O₂, CO (low/high/very high), CO₂, NO, NO₂, NOₓ, SO₂, H₂S, flue gas temperature (0–1100 °C), ambient air temperature (0–100 °C), differential pressure (±100 hPa), static pressure (±100 hPa), flue gas velocity (3–100 m/s) |
| Display | 3.5″ color TFT LCD with LED backlight & zoom function |
| Data Storage | 16,000 internal records |
| Connectivity | Mini-USB (data transfer & charging), IrDA (infrared printer interface), optional Bluetooth 4.0 |
| Filtration | Integrated PTFE-reusable particulate filter + water separator |
| Gas Path | Stainless steel sampling probe & fittings |
| Power | Rechargeable Li-ion battery (≥6 h standard |
| Weight | < 800 g (main unit only) |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PENTOL |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Turbidimetric Spectrophotometry |
| Measurement Range | 1–200 ppm SO₃ |
| Accuracy | ±5% of reading (calibrated range) |
| Repeatability | ±2% |
| Response Time (90% FSD) | <120 s |
| Drift Stability | ±5% over 30 days |
| T90 Delay | ~60 s |
| Sample Flow Control | Precise dual-pump liquid/gas flow regulation |
| Absorbent | Aqueous isopropanol solution |
| Reaction Chemistry | SO₃ → H₂SO₄ → SO₄²⁻ → BaClO₄⁻ complex formation |
| Reagent Consumption | 0.25–2 cm³/h (adjustable) |
| Operating Ambient Temperature | 0–40 °C |
| Power Supply | 230 V / 110 V, 50/60 Hz, 350 W |
| Analyzer Module | 19″ rack, 6U height, 500 mm depth, 27 kg |
| Control Module | 19″ rack, 4U height, 500 mm depth, 13 kg |
| Probe Length Options | 1.0, 1.2, 1.5, 2.0 m |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS232 (optional, factory-configurable) |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Model | SO3 Generator |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Component |
| Measurement Accuracy | ±5% |
| Repeatability | ±5% |
| Response Time | 1 s |
| Long-Term Stability | ±5% |
| Target Analyte | SO₃ |
| Catalyst | V₂O₅ |
| SO₂ Feed Rate | 2–200 L/h |
| Air Dilution Flow | 100–5,000 L/h |
| Max Operating Temperature | 1000 °C |
| Heating Rate (to 500 °C, no load) | 20 K/min |
| Power Supply | 400 V / 30 A / 7 kW |
| Dimensions (L×W×H) | 1800 × 1400 × 1200 mm |
| Weight | 429 kg |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | AtmosFIR (Fixed Emission Source Version) |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Detection Targets | CO₂, H₂O, CO, SO₂, NO, HF, CH₄, HCN, and up to 1000+ gases |
| Repeatability | ±1% of full scale |
| Response Time | 120 s (T₉₀) |
| Operating Temperature Range | Heated optical path up to 180 °C |
| Detector | Thermoelectrically cooled DTGS (Deuterated Triglycine Sulfate) |
| Certification | UK MCERTS, M22 (Flue Gas Monitoring), ISO 14001-compliant design |
| Enclosure Rating | IP65-rated rugged transport case |
| Weight | <18 kg (carbon-fiber reinforced composite chassis) |
| Power Supply | 24 V DC or universal AC adapter (100–240 V, 50/60 Hz) |
| Data Output | USB 3.0, Ethernet, optional 4–20 mA analog outputs |
| Software Platform | PAS (Protea Analysis Suite) with PLS multivariate calibration engine |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProtIR 204M |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Accuracy (Relative Error) | <5% |
| Repeatability | <2% |
| Response Time | <30 s |
| Long-term Stability | <5% over 7 days |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, HCl, HF, NH₃, CH₄, N₂O, H₂O vapor, and >28 pre-calibrated VOCs & inorganic species |
| Spectral Resolution | 1–128 cm⁻¹ (selectable) |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Optical Path Length | 6.4 m |
| Detector | DTGS |
| IR Source | Globar mid-IR source |
| Beamsplitter | ZnSe |
| Sample Cell Material | Nickel-plated aluminum with gold-coated mirrors & BaF₂ windows |
| Operating Temperature | 5–40 °C |
| Weight | 71 kg |
| Dimensions | 117 × 66.5 × 43 cm |
| Data Interface | Ethernet (OPC DA v3.0 compliant), 16 × 4–20 mA outputs (optional), 5 × digital I/O (optional) |
| Software Suite | PAS, PAS-Pro, Protea Spectrum Viewer |
| Calibration Support | Automated N₂ purge, real-time pressure & temperature compensation, built-in zirconia O₂ sensor (optional), dynamic dilution module (optional) |
| Compliance | UK MCerts certified, compatible with BS EN 14181, EN 15267, ISO 12039, and EPA Method 320 |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS53-T |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Flame Ionization Detection (FID) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm (as propane) |
| Accuracy | ≤ ±1% of reading |
| Repeatability | < ±2% of full scale |
| Response Time | ≤ 2 s (without sampling line) |
| Stability | < ±2% of full scale (zero & span drift over 7 days: < ±2% and < ±4%, respectively) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-Sensitivity to O₂ | < ±2% of full scale |
| Detection Limit | < 2% of full scale |
| Zero Drift | < ±2% FS/week |
| Span Drift | < ±4% FS/week |
| Sample Flow Rate | ~90 L/h |
| Output Signals | 0–10 V or 0/4–20 mA |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz |
| Dimensions | 360 mm × 200 mm × 500 mm |
| Weight | ~20 kg |
| Certification | TÜV-certified |
| Optional Features | ppb-range capability, heated sampling line, front-mounted particulate filter, integrated zero-air & combustion air supply, H₂ or He/H₂ fuel selector, onboard calibration gas cylinder, onboard fuel cylinder, PC communication software |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XHCEMS7000 |
| Instrument Category | Continuous Emission Monitoring System (CEMS) Quality Assurance/Quality Control (QA/QC) Platform |
| Communication Protocol | Compliant with HJ/T 212-2017 |
| Data Storage | Local + Remote Sync |
| Calibration Gas Generation | SO₂ and NOₓ standard gas mixtures, programmable concentration range, high repeatability and accuracy |
| Brand | MADUR |
|---|---|
| Origin | Italy |
| Model | NOVO |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ≤ ±0.5% FS |
| Dimensions | 270 × 93 × 68 mm |
| Weight | 0.9 kg |
| Operating Temperature | +5 °C to +45 °C |
| Storage Temperature | +5 °C to +45 °C |
| Power Supply | Rechargeable Li-ion battery (6–8 h runtime) |
| Display | 7-inch capacitive touchscreen |
| Connectivity | Bluetooth 4.2, USB 2.0 |
| Compliance | EN 50379-1 & EN 50379-2 |
| Sensor Technologies | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂, H₂S, NH₃), Catalytic Combustion (CxHy), NDIR (CH₄, CO₂) |
| Max Simultaneous Gases | 4 sensor channels (configurable) |
| Brand | SERVOMEX |
|---|---|
| Origin | United Kingdom |
| Model | 2700 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurands | O₂ and combustible gases (e.g., CH₄, H₂, CO) |
| Measurement Principle | Zirconia electrochemical cell (O₂), thick-film catalytic thermal conductivity (Tfx) sensor (combustibles) |
| Operating Temperature | up to 1750 °C (3182 °F) |
| Accuracy | low indication error |
| Repeatability | high |
| Response Time | fast |
| Stability | high |
| Display | backlit LCD |
| Calibration | automatic on-site self-calibration |
| Certification | ATEX Category 3, FM Class I, Division 2, Group A–D |
| Flange Standard | ANSI 4″ 150 lb (with optional adapters) |
| Probe Materials | stainless steel / high-temperature alloy / ceramic |
| Optional | high-dust filtration, thermal isolation flange, probe retention assembly, insulated disc |
| Brand | SERVOMEX |
|---|---|
| Origin | United Kingdom |
| Model | SpectraExact 2500 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Single-Beam Dual-Wavelength Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) Photometry |
| Accuracy | Low measurement error |
| Repeatability | High |
| Response Time | Fast |
| Stability | Excellent |
| Target Gases | Corrosive, toxic, and flammable gases (e.g., CO, CO₂, CH₄, SO₂, NO, NO₂, NH₃, HCl, HF) |
| Certifications | UKCA, CE, ATEX, UKEx, IECEx |
| Enclosure Rating | IP66 |
| Optical Path | Dedicated, field-serviceable measurement cell |
| Maintenance Profile | Non-consumable sensing technology |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Core Analyzers | NSA-3080A Online Gas Analyzer, RBV-DUST/II In-Situ Dust Monitor, VPT511BF-A Volumetric Flow Meter |
| Data Acquisition | Integrated DAQ & Reporting Platform |
| Regulatory Alignment | Designed for compliance with HJ 75–2017, HJ 76–2017, EPA Method 1–4, 6C, 7E, 10, and ISO 12141, ISO 15712 |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-802 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% FS |
| Repeatability | ≤2% FS |
| Response Time | ≤90 s |
| Long-term Stability | ≤2% FS/7 days |
| Measured Gases | CO, CO₂, H₂, O₂ |