| Brand | Honeywell |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RAEGuard Lite Series Point-Type |
| Pricing | Upon Request |
| Detection Principle | Catalytic Combustion (for combustible gases) / Electrochemical (for toxic gases & O₂) |
| Sampling Method | Diffusion |
| Power Supply | 24 VDC (16–32 VDC operating range) |
| Typical Power Consumption | <1 W (electrochemical), 2 W typical / 5 W max (catalytic) |
| Output Signals | Configurable 4–20 mA (sourcing), optional HART® 7.2 protocol |
| Digital Interface | RS485 Modbus RTU |
| Relay Outputs | Optional 3 × 30 VDC / 5 A |
| Enclosure Rating | IP66 |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C (LEL & EC variants) |
| Operating Temperature | −40°C to +70°C |
| Operating Humidity | LEL: 0–95% RH (non-condensing) |
| Toxic/O₂ | 15–95% RH (non-condensing) |
| Pressure Range | 90–110 kPa |
| Dimensions (H×W×D) | 176 × 157 × 118.5 mm |
| Housing Material | Aluminum alloy |
| Sensor Housing Material | 316 stainless steel |
| Weight | ~2.3 kg |
| Optional Features | Built-in surge protection module, Bluetooth® wireless configuration, non-intrusive magnetic wand operation |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Searchline Excel |
| Certification | ATEX, UL, CSA, IEC 61508 SIL 2 |
| Output | MODBUS RTU (RS-485), 4–20 mA analog |
| Detection Principle | Non-dispersive infrared (NDIR) absorption spectroscopy |
| Operating Range | Up to 120 m path length |
| Environmental Rating | IP66/IP67, -40 °C to +60 °C |
| Compliance | EN 61000-6-2/-6-4, IEC 61326-1, PED 2014/68/EU |
| Sensor Compatibility | Fully compatible with Honeywell XNX universal transmitter platform |
| Mounting | Three-point alignment base with mechanical lock |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Searchpoint Optima Plus |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Certifications | ATEX, IECEx, UL, CSA, FM, SIL 2 (per IEC 61508) |
| Operating Environment | Hazardous Areas (Zone 1/21, Class I Div 1/2) |
| Gas Coverage | Hydrocarbons (e.g., methane, propane, butane, pentane, hexane, toluene, xylene, MEK, acetone), LPG, LNG, solvent vapors |
| Output Signal | 4–20 mA HART, Modbus RTU |
| Enclosure Rating | IP66/IP67 |
| Power Supply | 12–30 VDC |
| Response Time (T90) | <15 s typical for methane |
| Zero Drift | <2% LEL/year (typical, field-validated) |
| Sensor Lifetime | ≥10 years (NDIR optical path, no consumables) |
| Maintenance Interval | Recommended annual verification |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Searchzone Sonik |
| Pricing | Upon Request |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | Sensepoint XCD |
| Sensor Compatibility | Catalytic Bead (LEL), Electrochemical (Toxic Gases), NDIR (CO₂, CH₄, etc.) |
| Enclosure Material | LM25 Aluminum Alloy & 316 Stainless Steel |
| Certifications | IECEx, ATEX, UL, CSA, KTL, GB-Ex, CCCF |
| Output Signals | 4–20 mA (2-wire/3-wire sink/source), 3 Programmable Relays, Modbus RTU (RS-485) |
| Display | Backlit LCD with Tri-color Status Indicator (Green/Amber/Red) |
| Diagnostic Features | SureCell™ Sensor Recognition, Reflex™ Self-Diagnostics, Auto-Calibration Support |
| Environmental Rating | IP66, NEMA 4X, -40°C to +70°C Operating Range |
| Mounting | Integrated Wall-Mount Brackets, Plug-in Sensor Cartridge Design |
| Compliance | Designed for use in Class I Div 1/Zone 1 hazardous areas per IEC 60079-29-1, EN 45544-1, ISO 10156, and aligned with FDA 21 CFR Part 11 data integrity principles for alarm logging |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XNX |
| Pricing | Upon Request |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Model | HD-HW100A |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | Carbon Monoxide (CO) |
| Multi-Component Capability | Yes |
| Repeatability | ≤1.0% |
| Response Time (T90) | ≤90 s |
| Linearity Error | ≤±2% F.S. |
| Operating Temperature Range | -10°C to 50°C |
| Data Storage Capacity | >100,000 records |
| Battery Life | >8 h (fully charged) |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Connectivity | Wi-Fi, USB host/device, cloud platform integration |
| Calibration Options | N₂ zeroing & catalytic zeroing |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time algorithmic correction |
| Flow Measurement | Optional digital mass flow sensor |
| Data Output | ppm / mg/m³ (user-switchable) |
| Regulatory Compliance | JJG635–2011, HJ965–2018, GB/T18204.2–2014, GB9801–1988, GBZ/T300.37–2017 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray Attenuation Method |
| Measured Parameter | PM₁₀ |
| Range | 0–1000 / 5000 µg/m³ (standard) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions | 430 × 483.5 × 266 mm (W×D×H) |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-370 |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM2.5 and PM10 |
| Range | 0–1000/5000 µg/m³ (standard), up to 10,000 µg/m³ (custom configurations) |
| Repeatability | ±20 µg/m³ @ 200/500 µg/m³ |
| Linearity | ±30 µg/m³ @ 200/500 µg/m³ |
| Zero Drift | ±20 µg/m³/day across all ranges |
| Span Drift | ±30 µg/m³/day @ low ranges |
| Sampling Flow Rate | ~16.7 L/min |
| Measurement Interval | 1 hour |
| Data Output | RS-232C, optional LAN (TCP/IP), analog 0–1 V, pulse & contact I/O |
| Power Supply | AC 100 V ±10 V, 50/60 Hz, ~200 VA |
| Dimensions (W×D×H) | 430 × 483.5 × 266 mm |
| Weight | Monitor unit: ~19 kg |
| Sampling pump | ~5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APDA-375A |
| Measurement Principle | Beta-ray Absorption |
| Safety Classification | Non-explosion-proof |
| Measurement Range | Standard: 0–1000 / 0–5000 µg/m³ |
| Resolution | ±1.0 µg/m³ (instantaneous) |
| Accuracy | ±2.0 µg/m³ (24-h average) or ±1% of reading (for concentrations >80 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-h average), <4.8 µg/m³ (1-h average) |
| Sampling Flow Rate | 16.7 L/min |
| Cut-point Options | VSCC (Vortex Separation Cyclone Classifier) for PM10 |
| Operating Temperature | −30 to +60 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 220 V, 50/60 Hz |
| Power Consumption | ~200 VA (up to ~320 VA with optional dehumidification & heater) |
| Dimensions (Analyzer Unit) | 430 W × 400 D × 266 H mm |
| Weight (Analyzer Unit) | ~19 kg |
| Weight (Pump Unit) | ~5 kg |
| Analog Output | 4–20 mA or 0–1 V |
| Digital Interfaces | Optional RS-232C, Ethernet (TCP/IP) |
| Environmental Compliance | Designed for continuous ambient air quality monitoring per ISO 12103-1, EN 12341, and US EPA EQOA-PM-01 reference method equivalency criteria |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Instrument Type | Online Gas Analyzer |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Detection Limit | 0.050 ppmC (2σ, ≤5 ppmC range) or 0.5% F.S. (2σ, >5 ppmC range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Output Signals | 0–1 V / 0–10 V / 4–20 mA (user-selectable) |
| Data Storage | CF card (optional) |
| Communication | Ethernet/LAN interface (optional) |
| Display Language | English, German, French, Japanese |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APHA-370 |
| Measurement Principle | Flame Ionization Detection (FID) with Selective Combustion Technology |
| Target Analytes | CH₄, NMHC, THC (expressed as ppmC) |
| Standard Range | 0–5 / 10 / 20 / 50 ppmC |
| Optional Range | 0–100 ppmC (4 selectable spans, span ratio ≤10) |
| Detection Limit | 0.050 ppmC (2σ, for ranges ≤5 ppmC) or 0.5% F.S. (2σ, for ranges >5 ppmC) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| Zero Drift | ±0.1 ppmC/day or ±2.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day |
| Response Time (T90) | ≤60 s |
| Sample Flow Rate | ~0.9 L/min |
| Output Signals | 0–1 V, 0–10 V, 4–20 mA (user-specified) |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~33 kg |
| Display Language Options | English, German, French, Japanese |
| Data Storage | CF card (optional) |
| Network Interface | Ethernet/LAN (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory Benchtop CEMS |
| Detection Principle | Selective Catalytic Oxidation + Flame Ionization Detection (FID) |
| Measurement Targets | CH₄, NMHC, THC |
| Detection Range | 0–50 / 200 / 500 / 1000 / 2000 ppm (selectable full-scale ranges) |
| Response Time | <150 s at sample inlet |
| Configuration | Integrated VOC Analyzer for Stack/Flue Gas Applications |
| Compliance Context | Designed for regulatory-grade monitoring per EPA Method 25A, ISO 12039, and EN 12619 requirements |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APMA-370 |
| Instrument Type | Portable Gas Analyzer |
| Detection Target | Single-component (CO) |
| Measurement Range | 0–5 / 0–10 / 0–20 / 0–50 ppm (selectable) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤60 s (at lowest range) |
| Zero Drift | ±0.1 ppm/day or ±1.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day or ±3.0% F.S./week |
| Linearity Error | ±1.0% F.S. |
| Detection Limit | 0.05 ppm (2σ, for ranges ≤10 ppm) |
| Sample Flow Rate | ~1.5 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~16 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APNA-370(G) |
| Instrument Type | Online Continuous Emission Monitor |
| Measured Gases | Nitric Oxide (NO), Nitrogen Dioxide (NO₂), Total Nitrogen Oxides (NOₓ) |
| Response Time (T90) | ≤120 s |
| Detection Limit | 0.5 ppb (2σ, ≤0.2 ppm range) / 1.0% F.S. (2σ, >0.2 ppm range) |
| Measurement Range | 0–10 ppm (4 selectable sub-ranges, max span ratio 10:1) |
| Accuracy | ±1.0% F.S. (linearity & repeatability) |
| Zero Drift | ±1.0 ppb/day or ±1.0% F.S./day (whichever greater) |
| Span Drift | ±1.0% F.S./day |
| Sample Flow Rate | ~0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~21 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APNA-370 |
| Measurement Principle | Dual-Flow Modulated Chemiluminescence Detection (CLD) |
| Range Options | 0–0.1 / 0.2 / 0.5 / 1.0 ppm (standard) |
| LOD | 0.5 ppb (2σ, ≤0.2 ppm range) or 1.0% F.S. (2σ, >0.2 ppm range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0 ppb/day or ±1.0% F.S./day (whichever greater) |
| Span Drift | ±1.0% F.S./day |
| Response Time (T₉₀) | ≤120 s (at minimum range) |
| Sample Flow Rate | ~0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 W × 550 D × 221 H mm |
| Weight | ~21 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APOA-370 |
| Measurement Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Range | 0–0.1 / 0.2 / 0.5 / 1.0 ppm (standard) |
| Detection Limit | 0.5 ppb (2σ, ≤0.2 ppm range) or 0.5% F.S. (2σ, >0.2 ppm range) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0% F.S./day, ±2.0% F.S./week |
| Span Drift | ±1.0% F.S./day, ±2.0% F.S./week |
| Response Time (T90) | ≤120 s |
| Sample Flow Rate | ~0.7 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (configurable) |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~20 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APOA-370 |
| Instrument Type | Fixed-Position |
| Measurement Range | 0–10 ppm |
| Detection Limit | 0.5 ppb |
| Response Time (T90) | ≤120 s |
| Zero Drift | ±1% F.S./day |
| Resolution | 0.1 ppb |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APSA-370 |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Range | 0–100 ppb to 0–10 ppm (field-selectable) |
| Detection Limit | <50 ppt (3σ, 1-minute average) |
| Accuracy | ±1% of full scale |
| Response Time (T90) | <60 seconds |
| Sample Flow Rate | 0.5–1.0 L/min |
| Operating Temperature | 0–40 °C |
| Humidity Tolerance | 0–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | EPA EQOA-01, ISO 7935:1990, JIS K 0301 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APSA-370 |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Range | 0–0.05 / 0.1 / 0.2 / 0.5 ppm (standard) |
| LOD | 0.5 ppb (2σ, for ranges ≤0.2 ppm) or 0.5% F.S. (2σ, for ranges >0.2 ppm) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0% F.S./day (lowest range), ±2.0% F.S./week (lowest range) |
| Span Drift | ±1.0% F.S./day (lowest range), ±2.0% F.S./week (lowest range) |
| Response Time (T₉₀) | ≤180 s |
| Sample Flow Rate | ~0.7 L/min |
| Output Signals | 0–1 V / 0–10 V / 4–20 mA (configurable) |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz (user-specified) |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | COPA-3000 |
| Detection Principles | CO – Alternating Flow Modulation NDIR |
| Measurement Range (Standard) | CO: 0–200/500 ppm or 0–500/1000 ppm |
| CO₂ | 0–5/25 vol% |
| O₂ | 0–5/25 vol% |
| Accuracy | ±0.5% FS (repeatability, full scale) |
| Zero Drift | ±0.5% FS/day |
| Span Drift | ±1.0% FS/day |
| Response Time | ≤20 s (TD + T90, 3.0 L/min sample flow) |
| Sample Flow Rate | 1.5–3.0 L/min |
| Cooling Dew Point | ~5 °C (electronic cooler) |
| Output | DC 0–1 V (non-isolated), RS-232C |
| Power Supply | AC 100 V ±10%, 50/60 Hz |
| Dimensions (W×H×D) | 750 × 1054 × 710 mm |
| Weight | ~120 kg (excl. O₂ cylinder & regulator) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to 40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication Interface | RS-485 |
| Protocol | Modbus RTU |
| Baud Rates | 1200–19200 bps |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication Interface | RS-485, Modbus RTU (optional) |
| Sample Gas Requirements | O₂ <21%, dust-free, dry, pressure ≥1.98 kPa |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto-calibration (optional) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Minimum Detection Limit | 0–50 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (standard), optional 0–10 V / Modbus RTU via RS-485 |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂ (196–690 kPa |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Interference-Corrected Non-Dispersive Infrared (NDIR) Absorption |
| Measurands | CO, CO₂, CH₄ (configurable per application) |
| Range Options | 0–0.11 vol% to 0–100 vol% (CO/CO₂), 0–50 ppm to 0–2000 ppm (CH₄) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient | –5 to 40 °C, ≤90% RH |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / Modbus-RTU over RS-485 |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5–10 L/min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Correction |
| Detectable Gases | CO, CO₂, CH₄ (configurable) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero/Full-Scale Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (optional range) |
| Sample Flow Rate | 500 mL/min |
| Operating Temperature | −5 to +40 °C |
| Analog Output | Isolated 4–20 mA (DC), optional voltage outputs |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Sample Gas Requirements | O₂ <21%, dust-free, dry, pressure ≥1.98 kPa |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual standard |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (CO/CO₂), 0–50 ppm to 0–2000 ppm (CH₄) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V / 1–5 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Sample Contact Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5–10 L/min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Interference-Corrected Non-Dispersive Infrared (NDIR) Absorption |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) |
| Repeatability | ±0.5% FS (standard range) |
| Linearity | ±1.0% FS |
| Zero & Span Drift | ±2.0% FS/week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow | 500 mL/min |
| Operating Ambient | –5 to +40 °C, RH <90%, vibration <0.3 m/s² @ 100 Hz |
| Analog Output | Isolated 4–20 mA (DC), optional 0–10 V |
| Communication | RS-485, Modbus-RTU (selectable baud rates: 1200–19200 bps) |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Purge Gas | N₂, 196–690 kPa, 0.5 L/min (operational), 10 L/min (purge mode) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EIA-51d / EIA-51p |
| Explosion Protection Type | Ex d IIB+H2 T4 (EIA-51d) / Ex p II T4X (EIA-51p) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Interference Compensation |
| Detectable Gases | CO, CO₂, CH₄ (configurable per application) |
| Range | 0–0.11 vol% to 0–100 vol% (gas-dependent) / 0–50 ppm to 0–2000 ppm (gas-dependent) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero & Span Drift | ±2.0% F.S./week |
| Response Time (T90) | ≤20 s (standard), ≤40 s (extended range) |
| Sample Flow Rate | 500 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Operating Ambient Temperature | –5 to +40 °C |
| Analog Output | Isolated DC 4–20 mA (standard), optional 0–10 V / 0–5 V / 1–5 V / 0–16 mA |
| Communication Interface | RS-485 |
| Protocol | Modbus-RTU |
| Baud Rates | 1200–19200 bps |
| Wetted Materials | SUS304, SUS316, FKM, CaF₂, Au |
| Calibration | Manual (standard), Auto-calibration (optional) |