| Brand | ElectroOptic |
|---|---|
| Origin | Russia |
| Model | CONTOUR-IR |
| Sensor Type | Silicon-based CCD |
| Spectral Range | 700–1100 nm |
| Interface | USB 2.0 or GigE (configurable) |
| Pixel Resolution | 1392 × 1040 (standard) |
| Pixel Size | 6.45 µm × 6.45 µm |
| Read Noise | <15 e⁻ (rms, typical) |
| Dark Current | <0.001 e⁻/pixel/s @ 25°C |
| Cooling | Thermoelectric (Peltier), ΔT ≤ −20°C below ambient |
| Dynamic Range | >60 dB |
| Compliance | CE, RoHS |
| Brand | ElectroOptic |
|---|---|
| Origin | Russia |
| Model | CONTOUR-M |
| Spectral Range | 400–1700 nm |
| Sensor Type | High-Sensitivity Silicon CCD |
| Display | 4-inch TFT LCD |
| Mounting Thread | 1/4"-20 internal thread |
| Form Factor | Handheld, Compact Design |
| Intended Use | IR beam alignment, NIR system characterization, IR microscopy support, luminescence visualization, and cultural heritage diagnostics |
| Brand | ElectroOptic |
|---|---|
| Origin | Russia |
| Model | CONTOUR |
| Spectral Range | 350–1700 nm (UV–NIR) |
| Integrated Display | TFT-LCD |
| Imaging Sensor Type | Enhanced CCD with IR Conversion Device |
| Supply Type | Imported |
| Distributor Status | Authorized Distributor |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SU1024-LDH2 |
| Pricing | Upon Request |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | 1300B, 2048B |
| Pixel Size | 13.5 × 13.5 µm, 20 × 20 µm |
| Energy Range | <30 eV to ~20 keV |
| Cooling | Thermoelectric (to –55 °C) |
| Readout Speed | 50 kHz to 2 MHz |
| ADC Resolution | 16-bit |
| Interface | High-Speed USB 2.0 (with optional fiber-optic extension up to 50 m) |
| Vacuum Compatibility | UHV-rated (<10⁻⁹ Torr), in-situ mounting |
| Imaging Array | Back-illuminated CCD, no AR coating |
| Quantum Efficiency | >95% peak absorption efficiency across soft X-ray band |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Quad-RO 4320 |
| Pixel Size | 24 × 24 µm |
| Imaging Array | 2084 × 2084 pixels |
| Energy Range | ~3 keV to >20 keV |
| Quantum Efficiency (at 550 nm) | >70% |
| Readout Interface | IEEE 1394a (FireWire) |
| ADC Resolution | 16-bit |
| Maximum Readout Speed | 4 MHz (4 outputs × 1 MHz each) |
| Cooling | Thermoelectric (hot-stage) |
| Scintillator Compatibility | Interchangeable Gd₂O₂S:Tb screens optimized for 8, 12, and 17 keV |
| Software Platform | LightField (64-bit) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | XF-1024F, XF-1024B, XF-2048F, XF-2048B |
| Pixel Size | 13 × 13 µm (XF-1024 series), 13.5 × 13.5 µm (XF-2048 series) |
| X-ray Energy Range | <3 keV to >20 keV |
| Readout Speeds | 100 kHz and 2 MHz |
| ADC Resolution | 16-bit |
| Interface | High-speed USB 2.0 |
| Sensor Architecture | Front-illuminated (FI) or back-illuminated (BI) scientific CCD |
| Quantum Efficiency | Up to 97% at 550 nm (BI), 32% at 550 nm (FI) |
| Cooling | Thermoelectric (TE) with hot-spot suppression |
| Optical Coupling | Vacuum-integrated fiber-optic taper |
| Software Platform | LightField (64-bit), PICAM API |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | NIRvana: LN / NIRvana: 640 / NIRvana: 640ST |
| Sensor Format | 640 × 512 InGaAs FPA |
| Pixel Size | 20 × 20 µm |
| Spectral Range | 0.9–1.7 µm (NIRvana: 640 & 640ST), 0.9–1.55 µm (NIRvana: LN) |
| Peak Quantum Efficiency | up to 85% (0.95–1.5 µm) |
| Operating Temperature | –190 °C (LN), –85 °C (TE-cooled), –65 °C (ST) |
| Frame Rate | up to 110 fps |
| Interface | GigE Vision compliant |
| Bit Depth | 16-bit digitization |
| Readout Modes | 2 MHz / 5 MHz / 10 MHz |
| Software Platform | LightField 64-bit |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP audit trail capable, ASTM E1317-22 compatible for spectral radiometric calibration |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Camera Formats | 512×512 to 2048×2048 |
| Pixel Sizes | 13×13 µm, 13.5×13.5 µm, 20×20 µm, 24×24 µm, 26×26 µm |
| Spectral Range | 180–1100 nm |
| Cooling | Vacuum-sealed, thermoelectrically cooled to –90 °C |
| Readout | Dual-amplifier architecture (low-noise & high-dynamic-range modes) |
| Interface | High-speed USB 2.0 (2 MHz max readout rate) |
| Data Depth | True 16-bit digitization |
| QE | Up to 95% (eXcelon-enhanced back-illuminated deep depletion sensors) |
| Software | LightField 64-bit platform with IntelliCal wavelength/intensity calibration, PICAM API, LabVIEW/MATLAB/EPICS compatibility |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | KURO 1200B / KURO 2048B |
| Pixel Size | 11.0 × 11.0 µm |
| Quantum Efficiency | >95% (peak) |
| Read Noise | 1.3 e⁻ rms (median) |
| Full-Well Capacity | 80,000 e⁻ |
| Dynamic Range | 61,500:1 (95 dB) |
| Frame Rate | 82 fps @ 1200 × 1200 (12-bit), 41 fps @ 1200 × 1200 (16-bit) |
| Fill Factor | 100% |
| Spectral Optimization | UV–NIR (180–1100 nm) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | SOPHIA 2048B / SOPHIA 2048BX |
| Pixel Size | 15 × 15 µm |
| Sensor Architecture | Back-Illuminated CCD |
| Peak Quantum Efficiency | >95% (eXcelon-enhanced for 2048BX) |
| Cooling | ArcTec™ Thermoelectric Vacuum-Sealed Cryogenic System (down to –90 °C) |
| Readout Noise | ~4 e⁻ rms |
| Readout Speed | Up to 16 MHz (quad-port) |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic extension (up to 50 m) |
| Software Platform | LightField® 64-bit with IntelliCal™, PICAM API, LabVIEW/MATLAB/EPICS compatibility |
| Vacuum Warranty | Lifetime hermetic seal |
| Spectral Compatibility | UV-VIS-NIR (enhanced with eXcelon anti-fringing technology) |
| Mechanical Interface | Standard Nikon F-mount or spectrograph-compatible flange (ConFlat for SOPHIA-XO variant) |
| Brand | e2v |
|---|---|
| Origin | France |
| Model | OCTOPLUS |
| Pixel Size | 10 × 20 µm, 10 × 200 µm |
| Resolution | 2048 pixels |
| Max Line Rate | 20–250 kHz |
| Bit Depth | 10/11/12-bit |
| Interface | Camera Link® (Basic/Medium/Full), USB3 |
| Full Well Capacity | 140 ke⁻ / 200 ke⁻ |
| Quantum Efficiency | 54% @ 850 nm, 41% @ 890 nm |
| Read Noise | 5 e⁻ |
| Dynamic Range | 69–72 dB |
| SNR Max | 51–53 dB |
| PRNU (HF) | ≤ 0.5% |
| Integration Dead Time | 0.6 µs |
| Power Supply | 10–15 V DC (PoCL-compliant) |
| Power Consumption | < 3 W |
| Sensor Package | Ceramic or Organic |
| Programmable Gain | Analog ×1/×2/×4, Digital ×1–×7.996 |
| Offset Adjustment | −4096 to +4096 (12-bit LSB) |
| Trigger Modes | Internal/External line trigger with programmable exposure and line period |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SU1024-LDM |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GL2048R |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SU1024-LDH |
| Pricing | Upon Request |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | 1024-1.7, 1024-2.2 |
| Pixel Size | 25 µm (W) × 500 µm (H), 25 µm (W) × 250 µm (H) |
| Spectral Range | 800–1700 nm (1024-1.7), 1000–2200 nm (1024-2.2) |
| Digitization | 16-bit ADC |
| Max Acquisition Rate | 6600 spectra/sec |
| Cooling | Liquid nitrogen (77 K) |
| QE Peak | 88% (1024-1.7), 70% (1024-2.2) |
| Dark Current | <0.1 e⁻/pixel/sec @ 77 K |
| Read Noise | <15 e⁻ RMS (typ.) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | PIXIS-XO-100B, PIXIS-XO-100BR, PIXIS-XO-400B, PIXIS-XO-400BR, PIXIS-XO-1024B, PIXIS-XO-1024BR, PIXIS-XO-1300B, PIXIS-XO-2KB, PIXIS-XO-2048B |
| Pixel Sizes | 13 × 13 µm, 13.5 × 13.5 µm, 20 × 20 µm |
| Detection Range | <30 eV to ~20 keV |
| Cooling | Thermoelectric (–70 °C to –90 °C) |
| Readout Interface | High-speed USB 2.0 |
| ADC Resolution | 16-bit |
| Readout Speed | Up to 2 MHz |
| Sensor Architecture | Back-illuminated, deep-depletion CCD options available |
| Vacuum Interface | Rotatable ConFlat (CF) flange |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Range | PyLoN 100B/BR, 400B/BR, 2KB, 2KBUV, 2KF, 256E/BR |
| Pixel Size | 20 × 20 µm, 13.5 × 13.5 µm, 26 × 26 µm |
| Cooling | Liquid Nitrogen to –120 °C |
| Dark Current | ≤1 e⁻/pixel/hour |
| Spectral Response | 200–1100 nm |
| Readout Speed | 50 kHz – 4 MHz |
| Interface | Gigabit Ethernet |
| Software | LightField (64-bit) |
| QE Peak | Up to 98% (eXcelon-enhanced deep-depletion back-illuminated) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512BX3, 1024BX3, 1600 eXcelon3 |
| Pixel Size | 13 × 13 µm, 16 × 16 µm |
| Spectral Range | 180–1100 nm |
| Peak Quantum Efficiency | >95% |
| Cooling | −70°C vacuum-sealed thermo-electric |
| Readout Speed | Up to 34 fps full-frame |
| Interface | GigE Vision compliant |
| Data Depth | True 16-bit |
| Calibration | Built-in OptiCAL reference source with automated gain/offset correction |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model Variants | 512/1024EMB, 1024i, 1024f, 1024i-RF, 2048f |
| Pixel Sizes | 13×13 µm, 12.8×12.8 µm, 16×16 µm, 26×26 µm, 13.5×13.5 µm |
| Gating Speed | up to 1 MHz |
| Minimum Gating Width | <500 ps |
| Timing Precision | ±10 ps |
| Readout Speeds | 2–10 MHz |
| Data Depth | 16-bit |
| Interface | GigE (up to 50 m cable length) |
| QE Peak | >50% (Gen III filmless photocathode, 200–900 nm) |
| Dual-Image Acquisition Interval | 2 µs |
| Spectral Acquisition Rate | up to 10,000 spectra/s |
| Software Platform | LightField v6.x (64-bit, LabVIEW/MATLAB/EPICS compatible) |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model Variants | 512×512, 1024×1024, 1600×200, 1600×400 |
| Pixel Sizes | 13×13 µm, 13.5×13.5 µm, 20×20 µm, 24×24 µm |
| Sensor Architecture | Back-Illuminated EMCCD with eXcelon3 anti-fringing technology |
| Quantum Efficiency | Up to 95% at 650 nm |
| Cooling | Deep thermoelectric cooling (≤ –90 °C sensor operating temperature) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Variants | 400BR, 1024BR, 1300R/BR |
| Pixel Size | 13 × 13 µm, 20 × 20 µm |
| Operating Temperature Range | –70 °C to –90 °C |
| Energy Detection Range | ~3 keV to ~20 keV |
| Window Material | Beryllium (Be) vacuum window |
| Readout Architecture | Dual-output amplifier with selectable gain modes |
| ADC Resolution | 16-bit |
| Interface | High-speed USB 2.0 (up to 2 MHz readout rate) |
| Sensor Type | Deep-depletion back-illuminated CCD |
| Cooling Method | Thermoelectric (TE) cooling with vacuum-sealed package |
| Brand | ElectroOptic |
|---|---|
| Origin | Russia |
| Model | CONTOUR-IR digit |
| Interface | USB 2.0 (480 Mbps nominal, up to 400 MB/s sustained) |
| Sensor Type | High-sensitivity CMOS with microlens array and enhanced pixel cascade amplification |
| Spectral Range | 400–1700 nm |
| Bit Depth | 8-bit luminance output |
| Frame Rate | Real-time digital video output (dependent on resolution and host system bandwidth) |
| Software Compatibility | WDM driver architecture |
| Power Supply | Bus-powered via USB 2.0 |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | iDus, Newton |
| Pixel Size | 26 µm or 50 µm |
| Sensor Types | CCD, EMCCD, InGaAs (1.7 µm & 2.2 µm) |
| Cooling | Down to –100 °C (UltraVac™) |
| QE Peak | Up to 95% (VIS/NIR) |
| Dark Current | As low as 0.00007 e⁻/pix/s |
| Read Noise | As low as <1 e⁻ (EM mode) |
| Full-Well Capacity | Up to 170 M e⁻ |
| Spectral Acquisition Rate | Up to 193 spectra per second |
Show next