- All
- Favorite
- Popular
- Most rated
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 785 Raman Spectrometer |
| Pricing | Available Upon Request |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane SCT-320, IsoPlane 160 |
| Focal Length | 320 mm (SCT-320), 203 mm (160) |
| Aperture Ratio | f/4.6 (SCT-320), f/3.88 (160) |
| Spectral Resolution (PMT) | 0.05 nm (SCT-320), 0.10 nm (160) |
| Spectral Resolution (CCD, 1200 gr/mm, 435 nm, 20 µm pixels, 10 µm slit) | 0.08 nm (SCT-320), 0.15 nm (160) |
| Grating Mount | Motorized triple-grating turret with auto-recognition |
| Wavelength Range | UV to mid-IR (193 nm–>5 µm, depending on grating & detector) |
| Optical Coating Options | Acton #1900 enhanced Al (193 nm–mid-IR), protected Ag (>98% avg. reflectance), Au (NIR/SWIR) |
| Detector Compatibility | PIXIS, ProEM, PI-MAX4, NIRvana series |
| Software Platform | LightField v8+ (64-bit), supports LabVIEW, MATLAB, EPICS, and FDA 21 CFR Part 11-compliant audit trail modules |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model Variants | TR555, TR557, TR777, DM55, DM77 |
| Spectral Range | 200 nm – 2.2 µm |
| Resolution (Additive Mode) | up to 0.13 cm⁻¹ (TR777) |
| Resolution (Subtractive Mode) | up to 0.4 cm⁻¹ |
| Stray Light Rejection | <1×10⁻⁶ (enabling Raman measurements within 5 cm⁻¹ of Rayleigh line) |
| Focal Length Options | 500 mm, 750 mm, 1000 mm, 1500 mm, 1750 mm, 2250 mm |
| Aperture Ratio | f/6.5 – f/9.7 |
| Grating Compatibility | Up to 1800 grooves/mm |
| Operating Modes | Additive (high-resolution), Subtractive (ultra-low stray light), Independent Dual/Triple Stage |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane81-BRX/BX-VR, IsoPlane81-BRX-UR |
| Spectral Range | 200–1100 nm |
| Focal Length | 80.0 mm |
| f-number | f/4 |
| Spectral Resolution (FWHM) | 0.1 nm |
| Slit Width | 10–500 µm |
| Sensor Format | 1024 × 256 |
| Cooling | Thermoelectric to –45 °C |
| Peak Quantum Efficiency | >95% (up to >97% with eXcelon™) |
| Interface | USB 3.0 |
| Grating Options | 150–4320 g/mm |
| Optical Coating | Protected silver |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Sensor Type | Back-illuminated, fully depleted silicon CCD |
| Pixel Format | 1340 × 100 (HR/LD) or 1340 × 400 (HR/LD) |
| Pixel Size | 20 × 20 µm |
| QE | 75% @ 1000 nm (HR), optimized dark current < 0.0005 e⁻/pix/s (LD) |
| Readout Speed | Up to 32 MHz dual-ADC (HR), 16 MHz (LD) |
| Spectral Acquisition Rate | Up to 1650 spectra/s (continuous), 215 kHz (kinetics mode, HR only) |
| Cooling | ArcTec™ multi-stage thermoelectric cooling |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic USB extender (50 m) |
| Software | LightField 64-bit with PICAM SDK, IntelliCal wavelength & intensity calibration, LabVIEW/MATLAB/EPICS compatibility |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Raman Spectrometer |
| Pricing | Available Upon Request |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Model | S2050-400 / S2050-1k / S2050-130k |
| Spectral Range | 2.0–5.0 µm |
| Full-Spectrum Readout Rate | up to 130 kHz |
| Sensitivity | −80 dBm/nm |
| Resolution | down to 2.5 cm⁻¹ (2048-pixel detector array) |
| Input | fiber-coupled (SMF-28, FC/PC optional) |
| Software Interface | native GUI + MATLAB/Python/C (DLL) APIs |
| Compliance | compatible with GLP/GMP data integrity workflows via timestamped, audit-trail-enabled acquisition logs |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | FER-SCI-BRX, FER-SCI-BX |
| Focal Length | 80.8 mm |
| Aperture | f/4 |
| Spectral Resolution (full focal plane) | 0.20–0.24 nm |
| Wavelength Range | UV-NIR (200–1100 nm) and VIS-NIR (400–1100 nm) |
| Grating Options | 295, 600, 1200 g/mm (interchangeable single-grating turret) |
| Slit Widths | 10–500 µm (laser-cut, height 3.3 mm) |
| CCD Type | Back-illuminated, deep-depletion, frame-transfer architecture with eXcelon and UV coating |
| Sensor Format | 1024 × 256 active + 1024 × 256 storage (total 1024 × 512) |
| Peak Quantum Efficiency | 95% |
| Cooling | Thermoelectric to −60 °C |
| Read Noise | 10 e⁻ rms @ 1 MHz |
| Integration Time | Up to 40 minutes (FER-SCI-BRX), several hours (FER-SCI-BX) |
| Spectral Acquisition Rate | 292 fps (FVB mode, FER-SCI-BRX), 124 fps (FVB mode, FER-SCI-BX) |
| Kinetic Mode Speed | >10,000 spectra/s (10-row binning, FER-SCI-BRX), >5,000 spectra/s (10-row binning, FER-SCI-BX) |
| Wavelength Accuracy | 0.26 nm |
| Repeatability | 0.13 nm |
| Spatial Resolution | 38.5 lp/mm @ 50% contrast (Nyquist-limited, full focal plane) |
| Line Transfer Speed | Adjustable 5.6–35 µs/line (FER-SCI-BRX), 15.2–95 µs/line (FER-SCI-BX) |
| Nonlinearity | <1% @ 1 MHz |
| Gain Options | 1.5 or 3 e⁻/ADU |
| Interface | USB 3.0 (3 m cable included) |
| I/O | Three MCX coaxial ports (2 trigger outputs, 1 trigger input), onboard programmable timing generator |
| Software | 64-bit LightField with real-time processing engine, IntelliCal lamp integration for automated wavelength and intensity calibration |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | SP2150, SP2300, SP2500, SP2750 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LIBS-1000 |
| Pricing | Available Upon Request |
| Key Specifications | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SWIR Short-Wave Infrared Spectrometer |
| Pricing | Upon Technical Consultation |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S76120 Prototype |
| Spectral Range | 7.6–12 µm |
| Resolution | 8–10 cm⁻¹ |
| Full-Spectrum Readout Rate | 50 Hz |
| Sensitivity (Full Aperture) | 200 pW/nm (−67 dBm/nm) |
| Exposure Time | 1–200 ms |
| Field of View (FWHM, full angle) | 2.1° |
| ADC Bit Depth | 14-bit |
| Dark Noise RMS (100 ms) | 7 counts |
| Minimum Detectable Power (100 ms) | 200 pW/nm |
| Input Interface | Free-Space Optical |
| Polarization Sensitivity | Vertical |
| Max Operating Temperature | 30 °C |
| Dimensions (H×L×W) | 100 × 306 × 200 mm³ |
| Weight | 5 kg |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE Pro High-Performance Spectrometer |
| Detector Type | Back-Thinned CCD |
| Optical Resolution (FWHM) | Configurable from 0.14 nm to 10 nm (dependent on grating and slit) |
| Wavelength Range | 200–1100 nm (model-dependent configurations) |
| Signal-to-Noise Ratio | Up to 80,000:1 (at full signal, 10 s integration) |
| Dynamic Range | >85,000:1 (with 15,000-spectrum onboard memory buffer) |
| Integration Time | 8 ms – 60 s |
| Thermoelectric Cooling | Down to –15 °C below ambient |
| Interface | USB 3.0 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via OceanView software configuration) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE65 Pro Research-Grade Spectrometer |
| Detector | Hamamatsu S7031-1006 back-illuminated CCD |
| Quantum Efficiency | up to 90% |
| Cooling | TEC-controlled, down to −15 °C |
| Spectral Range (configurable) | 200–950 nm or 350–1100 nm |
| Slit Options | Interchangeable SMA905-mount slits |
| Stray Light Rejection | Enhanced via optimized grating and optical design |
| Signal-to-Noise Ratio | 1000:1 (full signal, 1 s integration) |
| Thermal Wavelength Stability | <0.005 nm/°C |
| Trigger Interface | TTL-compatible hardware trigger input/output |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiChannel Multichannel Spectrometer |
| Pricing | Available Upon Request |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Acton LS 785 |
| Focal Length | 85 mm |
| Aperture Ratio | f/2.0 |
| Spectral Resolution | 5 cm⁻¹ (with 25 µm fiber) |
| Linear Dispersion | 6.13 nm/mm @ 900 nm |
| Grating | 1200 g/mm, gold-coated |
| Wavelength Range | 750–1100 nm (tunable via micrometer-driven grating stage) |
| Optical Design | Prism-based, AR-coated fused silica prism + optimized f/2 imaging optics |
| Detector Compatibility | Fully compatible with Teledyne Princeton Instruments PIXIS and PyLoN deep-depletion CCD cameras |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | HyperChannel Hyperspectral Imaging Spectrometer |
| Pricing | Available Upon Request |
| Brand | ARC |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ARCoptix |
| Pricing | Upon Request |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | <5 nm |
| Wavelength Accuracy | <0.5 nm |
| Wavelength Temperature Drift | <0.03 nm/°C |
| Stray Light Suppression | –27 dB (broadband), –35 dB (narrowband) |
| Radiometric Accuracy | <5% |
| Dynamic Range | 5000:1 |
| Integration Time | 0.1–2000 ms |
| Wavelength Repeatability | <0.2 nm |
| Field of View (Relative Radiometry) | 10° |
| Field of View (Absolute Radiometry) | 180° |
| Compliance | IEC 60904-9 (Ed. 2), JIS C 8912, ASTM E927, IEC 60904-3 AM1.5 G spectral classes (50 nm bins) |
| Programmable Trigger Delay | 0–2000 ms (0.1 ms resolution) |
Show next