Industry-specific Instruments
Filter
Showing 5701–5730 of 6020 results
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.306 / No.306-L |
| Compliance | JIS C 5016 |
| Operating Principle | Dual-directional cyclic bending at defined mandrel radius |
| Temperature Range (No.306-L) | −20 °C to +25 °C |
| Actuation | Electromechanical reciprocating motion |
| Sample Clamping | Fixed and movable parallel plates with precision mandrel alignment |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.315 |
| Test Principle | Pendulum-based Elmendorf tear method |
| Standards Compliance | JIS K7128-2, ISO 1974, TAPPI T414, ASTM D1922 (equivalent), ISO 6383-2 |
| Load Options | Standard and Low-Load configurations |
| Measurement Unit | mN (millinewtons) |
| Specimen Requirements | Pre-cut slit in rectangular strip (63 mm × 75 mm typical) |
| Readout | Analog arc scale with vernier or digital display (optional upgrade) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.318 |
| Applicable Standards | JIS K5400, JIS K6549, JIS Z0208, TAPPI T448, TAPPI T464, ISO 2528 |
| Measurement Principle | Gravimetric Cup Method (Desiccant or Water-filled) |
| Temperature & Humidity Control | Requires External Environmental Chamber |
| Sample Format | Flat Sheet Specimens (Circular or Square, Typically 50–100 mm Diameter) |
| Compliance | Designed for Conformance with ASTM E96, ISO 2528, and JIS Z0208 Gravimetric Test Protocols |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.323-AUTO |
| Test Standards | JIS L1096, ASTM D726, TAPPI T460, ISO 5636-5, P8117 |
| Sample Size | 50 × 50 mm |
| Clamp Orifice Diameter | φ28.6 ± 0.1 mm (Effective Area: 642 mm²) |
| Outer Cylinder ID | φ82.6 mm |
| Inner Cylinder OD/ID | φ76.2 / φ74 mm |
| Inner Cylinder Height | 254 mm |
| Inner Cylinder Mass | 567 ± 0.5 g |
| Air Volume Range | 0–100 mL (25 mL graduations), 100–350 mL (50 mL graduations) |
| Timing Resolution | 0.1 sec (Digital Timer, Max 99999.9 sec) |
| Detection Method | Photoelectric Sensor |
| Power Supply | AC 100 V, 1-phase, 3 A, 50/60 Hz |
| Main Unit Dimensions/Weight | ≈ W150 × D230 × H420 mm / ≈ 20 kg |
| Control Panel Dimensions/Weight | ≈ W250 × D450 × H280 mm / ≈ 8 kg |
| Optional Accessories | Silicone Oil, Porous Plug Adapter (φ10 mm) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.401 |
| Test Method | Calcium Chloride Desiccant Method (JIS L 1099 Type A-1) |
| Application | Textile Fabric Moisture Vapor Transmission Evaluation |
| Cup Type | Bolt-Tightened Sealed Permeation Cell |
| Compliance | JIS L 1099–2012 Annex A1 (Desiccant Method) |
| Dimensions | Standard 60 mm inner diameter test area |
| Material | High-Purity Stainless Steel (SUS316) body with fluoropolymer-sealed gasket |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.402 |
| Compliance Standards | JIS L1092, JIS K6404-8, ISO 4920 |
| Test Height | 150 mm |
| Spray Angle | 45° |
| Application | Water Repellency Evaluation of Textiles, Rubber, and Plastic Films |
| Supplier Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.404 |
| Compliance | JIS L1018, JIS L1085, JIS L1096, JASO Standards |
| Measurement Principle | Hydraulic Diaphragm Burst Test |
| Pressure Range | 0–600 kPa (typical for Mullen-type textile testers) |
| Diaphragm Material | Calibrated Elastomeric Rubber Membrane |
| Clamping Mechanism | Pneumatic or Mechanical Dual-Plate Clamp |
| Display | Analog Gauge or Digital Pressure Readout (configurable) |
| Sample Size | Standard 125 mm diameter circular specimen |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.409 |
| Complies with | JIS L 1092 (Method A – Low-Pressure Rise), ISO 811 |
| Test Principle | Hydrostatic Pressure Resistance Measurement via Controlled Water Column Rise |
| Operation Modes | Dynamic Water Level Rise (Standard A Method), Fixed-Pressure Hold, and Leakage Detection Mode |
| Sample Clamping | Dual-Ring Mechanical Clamp with Uniform Sealing Force |
| Maximum Test Height | ≥ 200 cm H₂O (typical range for textile hydrostatic head evaluation) |
| Resolution | 1 mm water column |
| Repeatability | ≤ ±2 cm H₂O (per ASTM D751 / ISO 811 inter-laboratory consensus) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.416 |
| Test Standard Compliance | JIS L0849, JIS L0862, JIS K6404-16, JIS K6547, ISO 105-X12 |
| Specimen Size | 140 × 50 mm |
| Cotton Cloth Size | 50 × 50 mm |
| Applied Load | 8.83 N (900 gf) |
| Friction Element Diameter | φ16 ± 1 mm |
| Stroke Length | 100 mm |
| Cycle Rate | 60 cycles/min |
| Counter | 6-digit presettable digital counter |
| Optional Accessories | Light-load kit, safety guard |
| Power Supply | AC 100 V, single-phase, 3 A, 50/60 Hz |
| Dimensions (W×D×H) | Approx. 260 × 640 × 260 mm |
| Weight | Approx. 16 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.428 |
| Standards Compliance | JIS K5701-1, K6404-16, K6547, K6772, L0849, L0862, L1084, P8136, ISO 105-X12 (JASO) |
| Specimen Dimensions | 220 × 30 mm |
| White Cotton Cloth | 50 × 50 mm |
| Initial Load | 1.96 N (6 optional weights provided) |
| Friction Element Radius | R45 mm, 20 × 20 mm contact area |
| Test Table Radius | R200 mm, semi-cylindrical (flat table optional) |
| Stroke Length | 120 mm (100 mm for flat table option) |
| Stroke Rate | 30 double strokes/min |
| Counter | 9-digit presettable digital counter |
| Optional Weights | 4.9 N and 9.8 N (6 total) |
| Power Supply | AC 100 V, 1-phase, 10 A, 50/60 Hz |
| Dimensions (W×D×H) | approx. 600 × 700 × 450 mm |
| Weight | approx. 70 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.445 |
| Measurement Principle | Pendulum-type Elmendorf method |
| Force Range Options | 0–8 N / 0–16 N |
| Specimen Dimensions | 63 ± 1 mm width × 100 ± 2 mm length |
| Initial Cut Length | 20 mm (residual ligament length: 43.0 ± 0.5 mm) |
| Clamp Width | 45 mm |
| Clamp Depth | 16.0 ± 0.5 mm |
| Clamp Gap | 2.8 ± 0.3 mm |
| Optional Accessories | Digital force display module, pneumatic clamping system |
| Dimensions (W×D×H) | Approx. 600 × 200 × 630 mm |
| Weight | Approx. 30 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.453 |
| Test Standard Compliance | JIS L 1018, JIS L 1058, JIS L 1076, JASO M 407 |
| Operating Principle | Rotating Tumbler with Cork-Lined Drum and Rubber Mandrels |
| Sample Mounting | Four cylindrical rubber mandrels with mounted fabric specimens |
| Evaluation Method | Visual comparison against standardized pilling reference photographs |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.473 |
| Test Standards | JIS L 1058, ASTM D3939 |
| Test Method | ICI Mace (Rotating Drum with Protruding Pins) |
| Rotation Cycles | 100 ± 1 rev |
| Sample Mounting | Cylindrical Mandrel Wrapped with Fabric Specimen |
| Evaluation | Visual Comparison Against Standard Photographic Rating Scale (Grade 1–5) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.510 |
| Compliance | JIS K 5101, JIS K 5400 |
| Application Principle | Eccentric gap control mechanism |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.519 |
| Standard Compliance | JIS K 6894 |
| Test Method | Spiral Scribe Adhesion Test |
| Load Application | Fixed Dead-Weight Loading |
| Stroke Pattern | Concentric Spiral (25 revolutions) |
| Evaluation Basis | Visual Comparison Against JIS Reference Charts |
| Sample Substrate | Metallic Panels with Fluoropolymer Coatings |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.527/547 |
| Standards Compliance | JIS K5101, JIS K5400, JIS K5600-2-5, JIS K5701-1, ASTM D1210, ISO 1524 |
| Measurement Principle | Mechanical groove-depth-based particle visibility detection |
| Groove Depth Range | 0–100 µm (typical linear scale) |
| Scale Resolution | 2.5 µm per division (standard JIS/ASTM scale) |
| Material | Hardened stainless steel body with precision-ground stainless steel groove plate |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.542-AB |
| Compliance Standards | JIS K 5101, JIS K 5400, ASTM D823 |
| Operation Principle | Vacuum-assisted, motor-driven drawdown with precision gap control |
| Substrate Fixation | Vacuum suction through perforated platen |
| Coating Method | Fixed-gap bar coating (compatible with wire-wound rods and adjustable applicator bars) |
| Drive System | Stepper motor with constant linear speed control |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.542-AB-H |
| Compliance Standards | JIS K5101, JIS K5400, ASTM D823 |
| Heating Plate Function | Yes |
| Vacuum-Assisted Substrate Fixation | Yes |
| Substrate Compatibility | Coated paper, plastic films, foils |
| Application Method | Adjustable-speed draw-down bar coating |
| Supplier Type | Authorized Distributor (Imported Equipment) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.546 |
| Compliance | JIS K 5101 |
| Operating Principle | Vacuum-assisted dual-glass-disc mulling under controlled load and rotation |
| Sample Handling | Manual loading, fully automated grinding cycle |
| Drive System | Precision stepper motor with programmable speed and dwell time |
| Vacuum System | Integrated vacuum pump (≤10 kPa absolute) for air removal during dispersion |
| Disc Material | Optical-grade ground glass (φ150 mm, parallelism ±2 µm) |
| Load Application | Pneumatically actuated vertical force (adjustable 0–200 N) |
| Cycle Control | Fully programmable sequence (grinding time, rest intervals, lift/lower timing) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.551-AUTO-1 |
| Test Standards | JIS D 0202, JIS K 5400, JIS K 5600-5-6, ASTM D2197, ISO 2409 |
| Sample Stage | 90 × 90 mm, 90° automatic rotation |
| Max. Travel | 50 mm (X), 50 mm (Y) |
| Cut Spacing | 0.5 / 1.0 / 1.5 / 2.0 mm (4-step selection) |
| Cutting Speed | 5 / 10 / 15 / 20 mm/s |
| Number of Cuts | Programmable via timer (standard: 6 or 11 cuts) |
| Load Range | 10–350 gf (counterweight-based) |
| Cutting Needle | φ3 mm diameter, 23 mm length, 60° tip angle |
| Power Supply | AC 100 V, 1-phase, 5 A, 50/60 Hz |
| Dimensions (w/o guard) | 630 × 750 × 700 mm |
| Weight | ~90 kg |
| Dimensions (with guard) | 630 × 750 × 760 mm |
| Weight | ~95 kg |
| Optional Accessories | Electrical continuity module, blade mounting jig, linear displacement sensor |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.553-M |
| Test Angle | 45° (60° for enameled wire) |
| Stroke Range | Horizontal ≤100 mm, Vertical ≤50 mm |
| Scratching Speed | 0.5–1 mm/s (motor-driven, continuously adjustable) |
| Load Capacity | Up to 1 kgf (beam balance type) |
| Test Table Dimensions | M-1: 100 × 180 mm |
| M-2 | 150 × 180 mm |
| Accessories Included | Mitsubishi Uni pencils (6B–9H, 17 pcs), steel stylus (1 pc), dedicated pencil sharpener, #400 abrasive paper, spirit level |
| Optional Accessories | Heated stage, electrical continuity module, φ3 mm × 23 mm conical stylus (60° tip angle) |
| Power Supply | AC 100 V, single-phase, 3 A, 50/60 Hz |
| Dimensions & Weight | M-1: ~440 × 200 × 440 mm, ~20 kg |
| M-2 | ~440 × 260 × 440 mm, ~27 kg |
| Compliance Standards | JIS C3003, JIS K5400, JIS K5600-5-4, JIS K5651, JIS K6894, JIS K6902, ASTM D2197, ASTM D3363, ISO 15184, GB/T 6739 |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WZR |
| Pricing | Upon Request |
| Measurement Range | 0–50 mm (0–500 penetration units) |
| Minimum Resolution | 0.01 mm (equivalent to 0.1 penetration unit) |
| Displacement Sensor Resolution | 0.01 mm |
| Standard Cone Assembly Mass | 150.0 g ± 0.1 g (cone body: 114.44 g ± 0.07 g) |
| Timing Range | 1.0–9.9 s (adjustable in 0.1 s increments) |
| Interface | RS-232 serial port |
| Printer | Built-in RMD III 32PHR-410 thermal microprinter |
| Display | LCD panel |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 30 W |
| Dimensions (W × D × H) | 340 × 280 × 600 mm |
| Net Weight | 16 kg |
| Compliance | GB/T 269–1991, Chinese Pharmacopoeia (ChP) General Chapter 0902 |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WZR-2 |
| Pricing | Upon Request |
| Measurement Range | 0–50 mm (0–500 penetration units) |
| Minimum Resolution | 0.01 mm (0.1 penetration unit) |
| Displacement Sensor Resolution | 0.01 mm |
| Standard Cones | Cone I — total mass 150.0 g ± 0.1 g (cone body 131.78 g ± 0.07 g) |
| Timing Range | 1.0–9.9 s |
| Interface | RS-232 |
| Printer | Built-in RMD III 32PHR-410 thermal printer |
| Display | LCD |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 30 W |
| Dimensions (W×D×H) | 340 × 280 × 600 mm |
| Net Weight | 16 kg |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YiHeng Drug Stability Testing Chamber |
| Price Range | USD 3,200 – 8,100 (FOB Shanghai) |
| Temperature Range | 0°C to 65°C |
| Humidity Range | 20% RH to 98% RH |
| Temperature Uniformity | ±0.5°C (at 25°C) |
| Humidity Uniformity | ±3% RH (at 60% RH) |
| Control Accuracy | ±0.3°C (temperature), ±2.0% RH (humidity) |
| Illumination Option | 0–6000 lx, adjustable via calibrated photometric sensor |
| UV Sterilization | Optional 254 nm germicidal lamp (rear-mounted, timer-controlled) |
| Compliance | Designed per Chinese Pharmacopoeia (2020 Edition), GB/T 10586–2006, ICH Q1A(R2), Q1B, Q5C, and aligned with FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LHH Series |
| Price Range | USD 8,600 – 23,500 (FOB Shanghai) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | LHH-250SD |
| Price | USD 5,600 (FOB Shanghai) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LHH-250SD |
| Chamber Volume | 250 L |
| Temperature Range | 0–65°C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±0.5°C (at 25°C) |
| Humidity Uniformity | ±3% RH (at 60% RH) |
| Temperature Stability | ±0.3°C |
| Humidity Stability | ±2% RH |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LHH-250SDP |
| Temperature Range | 0–70°C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±0.5°C (at 25°C) |
| Humidity Uniformity | ±3% RH (at 60% RH) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LHH-400GP |
| Temperature Range | 0–70°C |
| Humidity Range | 20–98% RH (at 25°C) |
| Illumination Control | 0–6000 lx (adjustable, ±500 lx accuracy at 4500 lx setpoint) |
| Light Source | LED or Fluorescent (UV-A compliant, 320–400 nm) |
| Compliance | Chinese Pharmacopoeia 2020, GB/T 10586–2006, ICH Q1A(R2), Q1B, Q5C |
| Control System | Programmable Touchscreen Controller (100 programs × 1000 segments × 999 cycles) |
| Data Logging | Built-in memory + RS-485/RS-232 interface + optional thermal printer support |
| Safety | Dual independent temperature limit alarms, humidity deviation alarms, password-protected operation, UV sterilization option (optional), real-time fault diagnostics |
