Industry-specific Instruments
Filter
Showing 2941–2970 of 6575 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 050D-200 |
| Pricing | Upon Request |
| Brand | SDLATLAS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | D394 |
| Quotation | Upon Request |
| Working Width | 300 mm (12 in) |
| Roller Diameter (Neoprene) | 54 mm (2.125 in) |
| Linear Speed | 25 mm/s (1 in/s) |
| Static Load Capacity | 50 kg (105 lb) ± 2.3 kg (5 lb) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BX-10 |
| Price | Upon Request |
| Capacity | 100 L/h |
| Minimum Batch Volume | 1000 mL |
| Pasteurization Temperature Range | 30–90 °C |
| Temperature Control Accuracy | ±1 °C |
| Filling Volume | Programmable & Auto-Quantified with Liquid-Level Sensing |
| Compatible Containers | PET bottles, PE bottles, glass bottles, and heat-resistant flexible packaging |
| Safety Interlock | Filling disabled unless product temperature reaches setpoint |
| Power Supply | 8.5 kW, 380 V, 3-phase 5-wire |
| Net Weight | 50 kg |
| Dimensions (L×W×H) | 550 × 450 × 500 mm |
| Brand | Eurotech |
|---|---|
| Origin | Italy |
| Model | XTR20 / XTR25 |
| Extruder Type | Single-Screw Cast Film Extruder |
| Die Material | Special Alloy Steel |
| Chill Roll Configuration | Single, Dual, or Triple Roll |
| Web Width Range | 100–500 mm |
| Optional Features | Unwind Unit for Extrusion Coating, In-Line Gel Detection System |
| Supply Type | Imported Equipment |
| Distributor Status | Authorized General Distributor |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | C706 |
| Pricing | Upon Request |
| Hourly Output (16 oz cups) | 511 |
| Freezing Cylinder Capacity | 3.2 L |
| Ingredient Hopper Capacity | 18.9 L |
| Compressor Cooling Capacity | 9,500 BTU/hr |
| Agitator Motor Power | 1.5 HP |
| Electrical Supply | 380 V, 12 A |
| Net Weight | 150 kg |
| Dimensions (W×L×H) | 464 × 864 × 860 mm |
| Brand | PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-1400 |
| Max. Compression Force | Not Specified |
| Production Rate | 140 tablets/min (variable speed) |
| Die Cavity Diameter Range | 3–20 mm (interchangeable tooling) |
| Construction | 304 stainless steel frame |
| Compliance | Designed to meet core GMP operational requirements for laboratory-scale solid dosage form development |
| Mobility | Integrated casters |
| Drive System | Built-in motorized drive |
| Optional Accessories | Hopper extension, custom-shaped punch sets |
| Control Mode | Fully automated, push-button + jog-reverse function |
| Brand | Labsphere |
|---|---|
| Model | CSTM-QES |
| Origin | Shanghai, China |
| Excitation Wavelengths | 308, 365, 405, 455, 535, 590, 740 nm |
| Integration Sphere Diameter | 6 inch (152 mm) |
| Internal Coating | Spectraflect® |
| Excitation Spot Size | ≤6 mm diameter at 7 mm working distance |
| Spectrometer | CDS2600 (350–1050 nm, 1 nm spectral resolution) |
| NIST-Traceable Calibration Standard | 2Pi-1-INT-050 |
| Sample Types | Thin films, powders, liquid solutions |
| Measurement Mode | DC (steady-state) |
| Software | Custom-developed PLQE analysis suite supporting direct and AM (Absorption-Modified) methods |
| Compliance | NIST-traceable radiometric calibration, ISO/IEC 17025-aligned measurement traceability framework |
| Brand | Labsphere |
|---|---|
| Model | HELIOS-A |
| Origin | USA |
| Light Source Technology | Electrodeless Plasma Lamp (Primary), Halogen & Xenon Options |
| Spectral Range | 250–2500 nm |
| Color Temperature Range | 3000 K–5300 K (Plasma), 3000 K–6500 K (Xenon), Customizable |
| UV Coverage | Yes (<380 nm) |
| Output Stability | <±0.5% over 1 hour (typical) |
| Dynamic Range | >150 dB (23-bit effective) |
| Calibration Traceability | NIST-traceable spectral irradiance |
| Trigger Mode | Continuous (Steady-State) |
| Compliance | ASTM E927-23, ISO 9022-11, IEC 60904-9 Ed. 3, MIL-STD-810H optical testing sections |
| Brand | Labsphere |
|---|---|
| Model | QES |
| Origin | USA |
| Type | Integrating Sphere-Based Monochromatic Light Source for Quantum Efficiency Testing |
| Measurement Mode | DC |
| Calibration Traceability | NIST-Traceable Spectral Irradiance and Radiance |
| Software Interface | SDK Available for Custom Test Sequence Development |
| Compliance Context | Designed to support ISO 15739, ISO 17850, and ASTM E2724-compliant QE characterization workflows |
| Key Applications | CMOS/CCD Image Sensor QE Mapping, Spectral Responsivity Validation, Pixel-Level Linearity Assessment, Module-Level Uniformity Analysis |
| Brand | Moon-BJ |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UV-2000S |
| Price Range | USD 14,000 – 28,000 |
| Brand | Labsphere |
|---|---|
| Model | UV1800F |
| Wavelength Range | 250–450 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth (FWHM) | < 4 nm |
| Wavelength Step | 1 nm |
| Optical Geometry | d/0 (diffuse illumination / 0° viewing) with integrating sphere |
| Sphere Port Diameter | 1.27 cm |
| Sample Illuminated Area | 1.26 cm² |
| Light Source | Pulsed Xenon Lamp |
| UV Dose per Measurement | < 0.2 J/cm² |
| Transmittance Range | 0–100% |
| Absorbance Range | 0–2.2 AU |
| UPF Range | 1–200+ |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183:2020, GB/T 18830:2009, JIS L 1925:2019 |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported (Non-China) |
| Model | LBM-125/250 |
| Drive System | Full Hydraulic |
| Control Interface | LCD Touchscreen (Auto/Manual Mode) |
| Safety Features | Interlocked Acrylic Viewing Door, Multi-Stage Alarm System |
| Compatible Resins | LDPE, HDPE, PP, PC, PS, PET |
| Optional Integration | Labtech Single-Screw Extruder (Φ20/25/30/45 mm) |
| Application Scope | Color Masterbatch Development, Rapid Formulation Screening, Pre-Production Bottle Prototyping |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-95 (115 V, 50–60 Hz), LC-95F (230 V, 50 Hz) |
| Drive Motor | Fully Enclosed DC Motor |
| Speed Range | 20–300 rpm |
| Roller Diameter | 2 in (50.8 mm) |
| Roller Material | Neoprene-Coated Steel |
| Maximum Feed Capacity | 84 L |
| Final Particle Size Range | 1–50 µm |
| Top Particle Size Input | ≤ 1 mm |
| Bearing Type | Sealed Ball Bearings |
| Drive System | Roller Chain Transmission |
| Frame Construction | Welded Structural Steel |
| Compatibility | Standard Borosilicate Glass, Alumina, or Porcelain Jars (sold separately) |
| Grinding Media | Ceramic, Stainless Steel, or Zirconia Beads (sold separately) |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported (Non-China) |
| Model | LCR |
| Screw Options | 12.5 mm, 20 mm, 25 mm, 30 mm, 45 mm |
| Max Film Width | 1100 mm |
| Min Film Width | 50 mm |
| Max Layers | 9 |
| Die Type | High-Performance T-shaped (Coat-Hanger) Cast Die |
| Winding | Pneumatic Shaft (Paperless) with Multiple Winding Configurations |
| Optional Units | Cast Roll Stack, Calender Roll Stack |
| Form Factor | Benchtop to Floor-Mounted Configurations Available |
| Brand | Labtech Engineering |
|---|---|
| Origin | Sweden |
| Model | LEP 20-6 |
| Screw Diameter | 20 mm |
| Target Tubing ID Range | 4–6 mm (customizable) |
| Vacuum Sizing & Cooling Tank | Integrated |
| Haul-off System | Belt-driven, variable-speed |
| Winder | Stepless-speed, tension-controlled |
| Optional | Laser-based diameter measurement system |
| Multi-layer Co-extrusion Capability | Yes |
| Compliance | Designed for ISO 13485-aligned R&D environments and ASTM D2136/D3835-compliant polymer processing validation |
| Brand | Labtech Engineering |
|---|---|
| Origin | Sweden |
| Model | LEP 45-50 |
| Screw Diameter | 45 mm |
| Pipe Diameter Range | 25–50 mm (customizable) |
| Configuration | Single-screw extruder with vacuum sizing tank, belt-type haul-off, automatic pipe cutter |
| Optional | Auto-stacking unit, laser diameter measurement system, multi-layer co-extrusion capability |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported |
| Model | LF-600 |
| Screw Options | 12.5 mm, 20 mm, 25 mm, 30 mm, 45 mm |
| Max Layflat Width | 1000 mm |
| Max Layers | 11 |
| Winding | Dual-station air-expanding shaft (coreless) |
| Tower Height | Adjustable |
| Cooling Ring | High-efficiency annular air ring |
| Die Type | High-performance spiral mandrel die |
| Form Factor | Benchtop to floor-standing configurations available |
| Brand | Labtech Engineering |
|---|---|
| Roll Diameter | 150 mm |
| Configuration | Horizontal Open Two-Roll Mill |
| Drive Type | Variable-Frequency AC Motor with Precision Speed Control |
| Roll Surface | Chrome-Plated Steel |
| Roll Gap Adjustment | Manual Micrometer with Digital Readout |
| Safety Compliance | CE Marked, EN ISO 13857 & EN 61800-5-1 Compliant |
| Construction | Heavy-Duty Cast Iron Frame with Reinforced Bearing Housings |
| Temperature Control Option | Optional Water-Cooled or Electrically Heated Rolls (±1 °C Stability) |
| Power Supply | 380–415 V, 3-Phase, 50/60 Hz |
| Dimensions (L×W×H) | 1850 × 920 × 1280 mm |
| Weight | Approx. 1,450 kg |
| Brand | Labtech Engineering |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model Range | LTE12, LTE16, LTE20, LTE26, LTE36 |
| Screw Diameter | 12–36 mm |
| L/D Ratio | 32–60 |
| Barrel Design | Split-shell (clamshell), modular |
| Screw & Barrel Material | Nitrided high-grade tool steel |
| Control System | PC-based fully automated control |
| Optional Modules | Vacuum venting port, liquid dosing pump, side-feeding fiberglass inlet, Labtech side-cutting granulator |
| Cooling | Integrated internal recirculating cooling system |
| Safety | Multi-level interlock alarms, gravity-balanced hinge mechanism, replaceable barrel liners |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MidiLab9000-E/P/T |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab Plate & Frame Fil |
| Pricing | Available Upon Request |
| Filtration Area | 1.7 ft² |
| Chamber Volume | 0.19 ft³ |
| Feed Flow Rate | 0.8–1.7 GPM |
| Maximum Operating Pressure | 100 psi |
| Frame Material | 316 Stainless Steel (standard) |
| Chamber Count | 6 |
| Plate Size | 8 in × 8 in |
| Actuation | Manual Handwheel with Hard-Chrome Bronze Nut & Hard-Chrome Steel Screw Shaft |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 060101 |
| Price | Upon Request |
| Energy Range Options | 0–6 J (0.003 J resolution) |
| Pendulum Angle | 90° arc |
| Impact Tip Geometry | Triangular pyramid (ISO 3036-compliant) |
| Display Accuracy | ±0.1 J |
| Adjustable Clamp Pressure | Yes |
| Data Interface | RS-232 |
| Power Supply | 230 V, 50 Hz |
| Dimensions (W×D×H) | 860 × 365 × 620 mm |
| Weight | 250 kg |
| Software Compatibility | REGISTRA III data acquisition and statistical analysis suite |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BLD-200N |
| Price | Upon Request |
| Load Capacity | 200 N (Standard) |
| Optional | 10 N, 30 N, 50 N, 100 N, 500 N |
| Accuracy Class | Class 1 |
| Resolution | 0.01 N |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Specimen Width | ≤30 mm |
| Stroke | 500 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 1000 × 370 × 400 mm |
| Net Weight | 27 kg |
| Standard Configuration | Main Unit, Micro Printer |
| Optional Accessories | Additional Load Cells, Lystem™ Software, RS232 Cable, Test Plates, Standard Roller, Sample Cutter, Custom Fixtures |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BLJ-02, YGJ-02A |
| Disc Pressure | 100 N |
| Peel Speed | 0.8 m/s |
| Roll Speed Options | 300 mm/min, 600 mm/min (adjustable) |
| Roller Load | 20 N ± 0.2 N |
| Roll Cycles | 3 (configurable up to 999) |
| Dimensions (BLJ-02) | 280 × 230 × 380 mm |
| Dimensions (YGJ-02A) | 360 × 230 × 260 mm |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight (BLJ-02) | 21 kg |
| Net Weight (YGJ-02A) | 25 kg |
| Compliance Standards | GB/T 7707, GB/T 7706, GB/T 4581, GB/T 2792, JIS C2107, JIS Z0237 |
| Brand | Labthink |
|---|---|
| Model | BMC-B1 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application Scope | Rigid PVC sheets for food packaging, pharmaceutical solid-dose blister lidding materials, plastic tamper-evident caps |
| Compliance Standards | GB/T 15267–1994, YBB00202005–YBB00232005, GB 5663–1985, GB/T 17876–2010 |
| Control System | Microprocessor-based with electromagnetic release mechanism |
| Sample Clamping | Pneumatic clamping system |
| Activation Modes | Manual push-button + foot pedal dual initiation |
| Drop Height Range | Adjustable (standard test heights per referenced standards) |
| Impact Mass | Standard steel ball (diameter and mass defined per applicable standard, e.g., 38 mm Ø, 45 g per GB/T 17876–2010) |
| Test Result Assessment | Visual inspection of cracks, punctures, or deformation post-impact |
| Brand | Labthink |
|---|---|
| Model | BMC-B1 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Compliance | GB/T 15267–1994 |
| Application | Impact Resistance Testing of Rigid PVC Sheets for Food Packaging |
| Test Principle | Controlled-height steel ball drop onto clamped specimen under standardized conditions |
| Reporting Metric | Percent Breakage Rate (defined as complete separation into ≥2 fragments) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic |
| Model | BMC-B1A |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Model | BST-01B |
| Measurement Range | 40–1600 kPa |
| Accuracy | ≤0.5% FS |
| Resolution | 0.1 kPa |
| Hydraulic Oil Flow Rate | 95 ± 5 mL/min (methyl silicone oil) |
| Diaphragm Resistance | 25–35 kPa (at 9 mm dome height) |
| Clamp Pressure | >430 kPa (adjustable) |
| Upper Clamp Ring ID | Φ(30.5 ± 0.05) mm |
| Lower Clamp Ring ID | Φ(33.1 ± 0.05) mm |
| System Seal Integrity | <10% Pmax pressure drop within 1 min |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 530 × 360 × 590 mm |
| Weight | 80 kg |
| Compliance | GB/T 454, GB/T 3198, ISO 2758, YBB00152002, GB 12255-90 |
| Brand | Labthink |
|---|---|
| Model | BST-02B |
| Measurement Range | 250–5600 kPa |
| Accuracy | ≤0.5% FS |
| Resolution | 0.1 kPa (low range) / 1 kPa (high range) |
| Hydraulic Oil Flow Rate | 170 ± 15 mL/min (methyl silicone oil) |
| Diaphragm Resistance | 170–220 kPa (10 mm dome height) |
| Clamp Pressure | >690 kPa (adjustable) |
| Clamp Ring Inner Diameter | Φ31.5 ± 0.05 mm (upper & lower) |
| Air Supply Requirement | 0.02–0.3 m³/min at 0.6–0.7 MPa |
| Dimensions | 530 × 350 × 600 mm |
| Weight | 85 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1539, GB/T 6545, ISO 2759 |
| Brand | Labthink |
|---|---|
| Model | BST-02B |
| Measurement Range | 250–5600 kPa |
| Accuracy | ≤0.5% FS |
| Resolution | 0.1 kPa (low range) / 1 kPa (high range) |
| Diaphragm Resistance | 170–220 kPa (10 mm dome height), 250–250 kPa (18 mm dome height) |
| Clamp Pressure | >690 kPa (adjustable) |
| Clamp Ring Inner Diameter | Φ31.5 ± 0.05 mm (upper & lower) |
| Hydraulic Oil Flow Rate | 170 ± 15 mL/min (methyl silicone oil) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 530 × 350 × 600 mm |
| Weight | 85 kg |
| Compliance | GB/T 1539, GB/T 6545, ISO 2759 |
