| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BTY-B3P |
| Price Range | USD 14,000 – 70,000 |
| Measurement Gases | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0.2–21% vol |
| O₂ Accuracy | ±0.2% vol |
| CO₂ Range | 2–100% vol |
| CO₂ Accuracy | ±2% vol |
| Sample Volume (O₂) | ≥5 mL (at 101.3 kPa) |
| Sample Volume (CO₂) | ≥20 mL (at 101.3 kPa) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 5.5 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BTY-B3P |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Differential Pressure Method (ISO 5636, SJT 1071.9, GB/T 36363-2018) |
| Measurement Range | 10–10,000 s/in²·100 mL·1.21 kPa |
| Pressure Differential Range | 0–20 kPa (customizable) |
| High-Pressure Resolution | 0.01 kPa |
| High-Pressure Accuracy | ±0.05 kPa |
| Low-Pressure Resolution | 0.1 Pa |
| Low-Pressure Accuracy | ±0.3 Pa |
| Specimen Area | 12.56 mm² (0.019 in², customizable) |
| Specimen Dimensions | ≥12 mm × 12 mm |
| Sample Capacity | 1–3 specimens per test |
| Test Gases | N₂, O₂, CO₂, dry air (≥99.9% purity, user-supplied) |
| Gas Inlet Pressure | 0.6 MPa (87 psi) |
| Tubing Interface | Φ4 mm polyurethane |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Dimensions (L×W×H) | 390 × 433 × 410 mm |
| Net Weight | 27 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model Series | C130H, C230H, C330H, C390H, G2/131, VAC-V2, VAC-VBS, ET-01, MF-01, FT-F1, TS-01, RT-01, MCJ-01A, YGJ-02A, BLJ-02, GC-7800, C830, ERT-01, Migration Test Cells |
| Compliance Standards | ASTM D3985, ASTM F1249, ISO 15106-2, ISO 15106-3, GB 31604.1-2015, GB 5009.156-2016 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ (H₂ and CH₄ available on custom configuration) |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Max. Vacuum Level | ≤10 Pa in test chamber |
| Pressure Control Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Sample Area | 38.48 cm² (11.2 cm × 11.2 cm) |
| Max. Sample Thickness | 3 mm |
| Chamber Count | 6 independent test chambers |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (user-selectable) |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Labthink-C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ (H₂, CH₄ available on custom configuration) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Max. Vacuum Level | ≤10 Pa in test chamber |
| Pressure Control Range | 10–150 kPa (adjustable), stability ±0.2 kPa |
| Sample Area | 38.48 cm² (11.2 cm × 11.2 cm) |
| Max. Sample Thickness | 3 mm |
| Number of Test Cells | 6 independent chambers |
| Humidity Range | 0% RH |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Measurement Principle | Differential-Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Capability | ≤10 Pa base pressure, 0.01 Pa resolution, ±0.2% accuracy (1–100% of sensor span) |
| Test Area | 38.48 cm² |
| Specimen Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa (adjustable), ±0.2 kPa stability |
| Humidity Control | 0% RH or 5–90% RH ±2% (optional) |
| Test Stations | 6 independent chambers |
| Power Supply | 120 VAC±10% 60 Hz / 220 VAC±10% 50 Hz |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, CO₂, N₂, H₂, CH₄ (customizable) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), or 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Test Area | 38.48 cm² (11.2 cm × 11.2 cm sample) |
| Max Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Resolution | 0.01 °C |
| Temperature Uniformity | ±0.15 °C |
| Chamber Count | 6 independent test chambers |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Gas Inlet | Φ6 mm polyurethane tubing (min. supply pressure: 550 kPa / 79.7 PSI) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H Differential-Pressure Permeability Tester |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂, He (customizable), H₂, CH₄ (hazardous gas option) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Pressure Control Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Test Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Temperature Uniformity | ±0.15 °C |
| Temperature Resolution | 0.01 °C |
| Chamber Configuration | 6 independent test chambers |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Net Weight | 100 kg |
| Key Components | Imported high-precision vacuum transducer, imported pneumatic control system, imported vacuum pump (0.2 Pa ultimate vacuum), 12-inch Windows-based touch tablet |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| Model | C106H |
| Test Principle | Differential-pressure (manometric) method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ (user-supplied), optional H₂/CH₄ (custom) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), or 5–90% ±2% RH (optional) |
| Vacuum Capability | ≤10 Pa test chamber |
| Pressure Control | 10–150 kPa adjustable high-pressure cavity |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| OTR Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Resolution | 0.01 °C |
| Temp. Uniformity | ±0.15 °C |
| Vacuum Sensor Accuracy | ±0.2% of reading (1–100% FS) |
| Chambers | 6 independent, parallel test stations |
| Automation | Motorized sample clamping, auto lid actuation, vacuum pump sequencing, real-time pressure compensation |
| Control Interface | 12″ Windows-based touch panel |
| Data Output | OTR curves, permeability coefficient (P), diffusion coefficient (D), solubility coefficient (S), temperature profiles |
| Optional Compliance Packages | 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure data integrity module |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | C106H |
| Test Principle | Differential Pressure (ASTM D1434 / ISO 2556 / GB/T 1038) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Number of Test Cells | 6 independent chambers |
| Standard Test Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Supported Gases | O₂, N₂, CO₂ (H₂/CH₄ available on custom configuration) |
| Power Supply | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Test Gases | O₂, N₂, CO₂ (H₂, CH₄ optional on customization) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Min. Chamber Vacuum | ≤10 Pa |
| Test Area | 38.48 cm² (11.2 cm × 11.2 cm sample) |
| Max. Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable, ΔP stability <0.2 kPa) |
| Chamber Count | 6 independent test stations |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 115,000 |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂ (user-supplied) |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Transmission Rate (GTR) Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| GTR Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Uniformity | ±0.15 °C |
| Chamber Configuration | 6 independent test chambers |
| Data Output | Permeability Coefficient (P), Diffusion Coefficient (D), Solubility Coefficient (S), GTR curves, P vs. T plots, real-time pressure/temperature logging |
| Software Features | CFR 21 Part 11 compliance package (optional), audit trail, user permission levels, electronic signatures, raw data export (CSV, PDF, XML) |
| Control Interface | 12-inch Windows-based touch tablet |
| Automation | Auto-clamping, auto-vacuum control, auto-pressure compensation, motorized lid actuation with audio-visual alert |
| Vacuum Pump | Imported high-vacuum pump, ultimate vacuum ≤0.2 Pa |
| Pneumatic System | Imported solenoid valves & actuators, MTBF >100,000 cycles |
| Thermal Management | 360° circumferential air-circulation heating, PID-controlled uniformity |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (selectable) |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm (W × D × H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | C106H Gas Permeation Analyzer |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | O₂, N₂, CO₂ |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Capability | ≤10 Pa (Resolution: 0.01 Pa |
| Accuracy | ±0.2% of reading in 1–100% sensor span) |
| Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Pressure Range | 10–150 kPa (adjustable |
| pressure stability | ±0.2 kPa) |
| Humidity Control | 0% RH or 5–90% ±2% RH (customizable) |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable) |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent cavities |
| Standard Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Gases | O₂, N₂, CO₂ (H₂/CH₄ available on custom configuration) |
| Test Pressure | 10–150 kPa (adjustable, ΔP stability <0.2 kPa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 0% RH, or 5–90% ±2% RH (customizable) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Test Cells | 6 independent chambers |
| Sample Size | 11.2 cm × 11.2 cm (4.4″ × 4.4″) |
| Max. Sample Thickness | 3 mm (120 mil) |
| Standard Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂ (gas supply not included) |
| Test Pressure | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Inlet Pressure | 550 kPa (79.7 PSI) |
| Tubing Interface | Φ6 mm polyurethane |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Net Weight | 100 kg (220 lbs) |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Measurement Principle | Differential Pressure Method (ASTM D1434, ISO 15105-1, GB/T 1038-2000) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (optional 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Min. Detectable Permeation | 0.01 cm³/m²·24h·0.1MPa |
| Test Chambers | 6 independent chambers |
| Sample Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Vacuum Level | ≤10 Pa (pump limit: 0.2 Pa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price | Upon Request |
| Test Principle | Differential Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Test Gases | O₂, N₂, CO₂, CH₄, H₂ (CH₄/H₂ configurable) |
| Test Area | 38.48 cm² per chamber |
| Sample Thickness Limit | ≤3 mm |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% sensor span) |
| Vacuum Level | ≤10 Pa |
| Pressure Control Range | 10–150 kPa (adjustable, stability ±0.2 kPa) |
| Gas Transmission Rate (GTR) Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| GTR Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Stability | ±0.15 °C |
| Chamber Count | 6 independent test chambers |
| Sample Size | 11.2 cm × 11.2 cm |
| Power Supply | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | He, O₂, N₂, CO₂, CH₄ (customizable) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), or 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Permeability Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Temperature Stability | ±0.15 °C |
| Test Area | 38.48 cm² per chamber |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Number of Test Chambers | 6 independent |
| Pressure Control Range | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Inlet | Φ6 mm polyurethane tubing |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 mm × 490 mm × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | C106H |
| Test Principle | Differential Pressure Method (Manometric) |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent cavities |
| Standard Test Area | 38.48 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Test Gas Compatibility | H₂, CH₄, O₂, N₂, CO₂ (custom-configured for flammable gases) |
| Pressure Control Range | 10–150 kPa (adjustable, stability ±0.2 kPa) |
| Power Supply | 120 VAC±10% 60 Hz / 220 VAC±10% 50 Hz |
| Net Weight | 100 kg |
| Compliance | ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C106H |
| Price Range | USD 14,000 – 72,000 |
| Testing Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Test Gases | O₂, N₂, CO₂, H₂ (customizable), CH₄ (customizable) |
| Temperature Range | 15–50 °C (standard) |
| Humidity Range | 0% RH (dry), 5–90% ±2% RH (optional) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Number of Test Chambers | 6 independent chambers |
| Sample Area | 38.48 cm² (11.2 cm × 11.2 cm) |
| Max. Sample Thickness | 3 mm |
| Pressure Range (High-Pressure Side) | 10–150 kPa (adjustable) |
| Pressure Stability | ±0.2 kPa |
| Gas Transmission Rate (GTR) Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| GTR Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Resolution | 0.01 °C |
| Temperature Uniformity | ±0.15 °C |
| Power Supply | 120 VAC ±10%, 60 Hz OR 220 VAC ±10%, 50 Hz (user-selectable) |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Control Interface | 12-inch Windows-based touch panel |
| Optional Compliance Modules | FDA 21 CFR Part 11, GMP-compliant audit trail, DataShield™ data integrity package |
| Brand | Labthink |
|---|---|
| Model | C106H |
| Principle | Differential Pressure Method (ASTM D1434, ISO 15105-1, GB/T 1038-2000) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 15–50 °C (5–60 °C optional) |
| Temp. Stability | ±0.15 °C |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Test Chamber Vacuum Level | ≤10 Pa |
| Chamber Count | 6 independent chambers |
| Standard Test Area | 38.48 cm² |
| Max. Sample Thickness | 3 mm |
| Pressure Control Range | 10–150 kPa |
| Pressure Stability | ±0.2 kPa |
| Gas Options | O₂, N₂, CO₂ (H₂, CH₄ available on custom configuration) |
| Power Supply | 120 VAC ±10%, 60 Hz or 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 490 × 660 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential-Pressure (Manometric) Method |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Measurement Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Temperature Range | 10–50 °C (ambient reference 23 °C) |
| Temp. Stability | ±0.05 °C |
| Temp. Accuracy | ±0.3 °C (at calibration port) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Chamber Vacuum Level | <10 Pa |
| Specimen Quantity | 3 independent test chambers |
| Specimen Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (custom configurations available for flammable, explosive or toxic gases) |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Gas Supply Pressure | 0.5–0.6 MPa |
| Power Supply | 220 VAC ±10%, 50 Hz OR 120 VAC ±10%, 60 Hz |
| Dimensions (L×W×H) | 710 × 350 × 630 mm |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | C130H |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Vacuum Capability | <10 Pa (sensor resolution 0.01 Pa |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Sample Capacity | 3 independent test chambers (Φ97 mm, 38.48 cm² effective area) |
| Power Supply | 220 VAC ±10% 50 Hz or 120 VAC ±10% 60 Hz |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H-Labthink |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Differential Pressure Method (ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003) |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Test Temperature | 10–50 °C (±0.05 °C stability, ±0.3 °C accuracy via calibration port) |
| Vacuum Capability | <10 Pa chamber vacuum, sensor resolution 0.01 Pa, accuracy ±0.2% of reading (1–100% of sensor span) |
| Test Pressure Range | 10–210 kPa (adjustable, pressure drift <0.2 kPa during test) |
| Specimen Size | Ø97 mm |
| Effective Test Area | 38.48 cm² |
| Specimen Capacity | 3 independent test chambers |
| Gas Compatibility | O₂, N₂, CO₂, He, air, and custom hazardous or humidified gases (optional modules) |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz |
| Dimensions | 710 × 350 × 630 mm (L×W×H) |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Differential Pressure Method (Manometric) |
| Standards Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (ambient 23 °C) |
| Temp. Stability | ±0.05 °C |
| Temp. Accuracy | ±0.3 °C (via calibration port) |
| Vacuum Resolution | 0.01 Pa |
| Vacuum Accuracy | ±0.2% of reading (1–100% of sensor span) |
| Max. Test Chamber Vacuum | <10 Pa |
| Sample Quantity | 3 independent test cells |
| Sample Diameter | Φ97 mm |
| Effective Test Area | 38.48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (custom configurations available for flammable, explosive or toxic gases) |
| Test Pressure Range | 10–210 kPa (adjustable) |
| Gas Supply Pressure | 0.5–0.6 MPa |
| Power Supply | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (user-selectable) |
| Dimensions (L×W×H) | 710 × 350 × 630 mm |
| Net Weight | ~100 kg |
| Brand | Labthink |
|---|---|
| Model | C130H |
| Principle | Differential Pressure Method (Manometric) |
| Test Gases | O₂, N₂, CO₂ (customizable for mixed/inflammable gases) |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Pressure Range | 10–210 kPa (adjustable high-side pressure) |
| Vacuum Capability | <10 Pa base pressure, 0.2 Pa ultimate vacuum |
| Measurement Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Size | Φ97 mm (38.48 cm² effective area) |
| Chambers | 3 independent test stations |
| Compliance | ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1, YBB 00082003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | C130H |
| Price Range | USD 14,000 – 98,000 |
| Testing Principle | Differential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000) |
| Test Gases | O₂, N₂, CO₂ (customizable for mixed or hazardous gases) |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Pressure Range | 10–210 kPa (adjustable high-side pressure) |
| Vacuum Capability | <10 Pa chamber vacuum |
| Measurement Range | 0.01–50,000 cm³/(m²·24h·0.1MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1MPa) |
| Sample Capacity | 3 independent test chambers (Φ97 mm, 38.48 cm² effective area) |
| Compliance | ISO 2556, JIS K7126-1, YBB 00082003, GLP/GMP-ready (optional DataShield™ & 21 CFR Part 11 support) |
| Brand | Labthink |
|---|---|
| Model | C130H |
| Measurement Principle | Differential Pressure (ASTM D1434 / ISO 15105-1) |
| Test Gases | O₂, N₂, CO₂, Air, He (customizable for flammable/toxic gases) |
| Test Range | 0.01–50,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Temperature Range | 10–50 °C (±0.05 °C stability) |
| Vacuum Capability | <10 Pa base pressure, 0.01 Pa resolution |
| Pressure Control | 10–210 kPa (adjustable, ±0.2 kPa stability) |
| Sample Capacity | 3 independent chambers (Φ97 mm, 38.48 cm² effective area) |
| Compliance | GB/T 1038–2000, ISO 2556, JIS K7126-1, YBB 00082003, FDA 21 CFR Part 11 (optional), GMP Annex 11 (optional) |