| Brand | LEI-TECH |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Producer |
| Regional Category | Domestic (China) |
| Model | LK-JXFX |
| Price | USD 2,800 (FOB Tianjin) |
| Brand | LEI-TECH |
|---|---|
| Model | LK-KXL2000 |
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | VW 50093, VW 50097, ASTM E505 |
| Imaging Resolution | Up to 5 MP |
| Motorized Stage Travel | 70 × 70 mm |
| Stage Repeatability | ±5 µm |
| Minimum Step Resolution (16× microstepping) | 0.625 µm |
| Software Output Formats | DOCX, XLSX, PDF |
| Operating System | Windows 10 Enterprise |
| Brand | LEI-TECH |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | LK-KXLFX |
| Price Range | USD 21,000 – 42,000 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aivia |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Aperio Ariol |
| Slide Capacity | 4, 8, or 200 slides (with SL200 loader) |
| Fluorescence Channels | Up to 9 |
| Z-Stack Layers | Up to 30 |
| Clinical Validation | CE-IVD and FDA-cleared analysis modules available |
| Integration | Compatible with Aperio eSlide Manager and DIH (Digital Imaging Hub) |
| Microscope Platform | Leica DM600B automated upright microscope |
| Oil Immersion | Automated oil dispensing system |
| Software | Aperio Image Analysis Suite with real-time algorithm parameter tuning |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cell DIVE |
| Pricing | Available Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CytoVision® |
| Pricing | Available Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DM6 M LIBS |
| Application | Integrated Optical Microscopy + Laser-Induced Breakdown Spectroscopy (LIBS) for Real-Time Elemental Mapping |
| Sample Preparation | None Required |
| Analysis Speed | <1 Second per Spot |
| Spatial Resolution | ~5–10 µm (laser spot size dependent) |
| Spectral Range | 200–900 nm |
| Detection Capability | Qualitative & Semi-Quantitative Elemental Identification (Z ≥ 5, i.e., Boron and above) |
| Compliance | CE Marked, ISO 9001 Manufacturing Environment, Designed for GLP/GMP-Adjacent R&D and QC Environments |
| Brand | Leica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DMi8 |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Enersight |
| Import Status | Imported |
| Distribution Type | Authorized Distributor |
| Price Range | USD 6,800 – 13,600 (FOB Hamburg) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LAS X ID |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LAS X ID |
| Application Domain | Industrial Quality Control & Materials Science |
| Compliance | ISO 17025-aligned workflow support, GLP/GMP-ready audit trail capabilities, FDA 21 CFR Part 11–compatible user authentication and electronic signature options (via optional configuration) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LAS X Professional Analysis |
| Pricing | Upon Request |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | LAS X |
| Type | Integrated Microscopy Imaging & Analysis Platform |
| Compatibility | Leica Confocal, Widefield, Stereo, Super-Resolution, and Light-Sheet Microscopes |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Deployment | Windows-based client-server architecture with optional remote access via LAS X Mobile Connect module |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LAS X Steel Expert |
| Compliance Standards | ISO 4967, EN 10247, ASTM E45, DIN 50602, GB/T 10561, JIS G0555, SEP 1571 |
| Export Classification | Imported Instrument Software |
| Licensing | Modular standard-specific licensing |
| Data Export Formats | Excel (.xlsx), CSV (.csv), PDF (.pdf) |
| Interface | Dual-View synchronized microscopy workspace |
| Workflow Support | Multi-sample batch analysis, region-of-interest (ROI) mapping, manual & semi-automated inclusion classification |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | LMD6 |
| Cutting Principle | Gravity-assisted, beam-scanning laser microdissection |
| Optical Architecture | Upright microscope platform with galvanometric mirror-based laser beam steering |
| Sample Collection Method | Gravity-driven direct drop into collection vessels (e.g., PCR caps, 8-strip tubes, ibidi µ-slides, PEN-membrane slides) |
| Software Platform | Leica Application Suite (LAS) X v7.6 with AVC (Automatic Cell Recognition), time-lapse imaging, and workflow-driven ROI selection |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Slide Compatibility | PEN membrane slides, PET slides (low-additive), DIRECTOR slides (film-free), standard glass slides |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | LMD7 |
| Laser Wavelength | 349 nm |
| Pulse Repetition Rate | 10–5000 Hz |
| Pulse Duration | < 4 ns |
| Maximum Pulse Energy | 120 µJ |
| Optical Collection Method | Gravity-based |
| Compatible Objectives | 5× to 150× dry objectives (SmartCut series) |
| Illumination Options | LED (25,000 h lifetime, constant CCT) or Halogen with CCIC |
| Cutting Modes | "Move-Cut" (direct real-time laser scanning) and "Draw-Scan" (point-ablation without film) |
| Sample Compatibility | FFPE tissues, frozen sections, plant material, chromosomes, bone, teeth, brain, live cells in culture |
| Collection Vessels | Standard 0.2 mL/0.5 mL PCR tubes, multiwell plates, ibidi µ-slides, PEN-membrane slides, PET slides, DIRECTOR slides |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MICA |
| Price | USD 320,000 (FOB Hamburg) |
| Brand | Leica |
|---|---|
| Model | PAULA |
| Type | Integrated Live-Cell Monitoring Microscope System |
| Optical Configuration | Phase Contrast + Optional Fluorescence Modules |
| Imaging Mode | Automated Time-Lapse Microscopy |
| Connectivity | Wi-Fi 5 (802.11ac), Ethernet, USB-C |
| Barcode Reader | Integrated High-Speed 1D/2D Scanner |
| Multi-Unit Synchronization | Up to 4 Units via Local Network |
| Data Storage | Onboard SSD + Cloud-Ready Encrypted Database |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Traceable Metadata Logging |
| Remote Access | Web-Based Dashboard (HTTPS/TLS 1.2), Cross-Platform Client (Windows/macOS/iOS/Android) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | SCN400 |
| Automation | Integrated SL801 384-slide autoloader |
| Max Magnification | 40× |
| Avg. Scan Time (20×) | 100 s per slide |
| Focusing Technology | Patented Dynamic Focus Tracking |
| Software Platform | Leica SCN400 Client |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager 3D Live Cell |
| Core Technology | Computational Clearing (real-time deconvolution for widefield fluorescence) |
| Imaging Modality | High-sensitivity widefield fluorescence microscopy with integrated environmental control |
| Camera | DFC9000 GTC sCMOS (QE up to 82%) |
| Illumination | Multi-line high-intensity LED source with narrow excitation bandwidths |
| Stage | Quantum motorized stage (≤ ±0.25 µm reproducibility |
| Focus Control | Adaptive Focus Control (AFC) + closed-loop Z-drive (20 nm repeatability) |
| Throughput | Up to 90 fps full-frame acquisition |
| Z-stack Speed | 150-layer stack in <60 s |
| Environmental Chamber | Integrated CO₂, temperature & humidity control with micro-humidifier for long-term live imaging |
| Software Platform | LAS X (GLP-compliant, audit trail enabled, FDA 21 CFR Part 11 ready) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER Imager Cell Spinning Disk System |
| Category | Spinning Disk Confocal Microscopy Platform for 3D Live-Cell and Thick-Tissue Imaging |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | THUNDER |
| Imaging Principle | Widefield Fluorescence with Real-Time Computational Clearing |
| Compliance | ISO/IEC 2382:2015 (Information Technology — Vocabulary), GLP/GMP-Ready Data Integrity Architecture |
| Software Platform | Leica Application Suite X (LAS X) v4.13+ |
| Data Handling | Native Support for TIFF, OME-TIFF, HDF5 |
| Regulatory Context | Designed for 21 CFR Part 11–compliant environments with optional audit trail and electronic signature modules |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nano-Cyte® |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MT Year-Ring Measurement and Analysis System |
| Pricing | Upon Request |
| Resolution | 5 µm |
| Max Sample Count per Session | 1000 |
| Measurement Points per Sample | Up to 500 |
| Data Memory Capacity | 256 kB / 512 kB / 1 MB (configurable) |
| Power Supply | DC 6–9 V |
| Max Annual Ring Width | 100 mm |
| Operating Temperature | 0 °C to 50 °C |
| Software | T-TOOLS LIGHT v3.x / T-TOOLS PRO v4.x |
| Data Export Formats | ASCII (tab-delimited), MST (proprietary binary format for T-TOOLS ecosystem) |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MMO-203 |
| Manipulator Travel (X/Y/Z) | 10 mm |
| Fine Adjustment Resolution | 2 µm |
| Coarse Travel (X/Y/Z) | 22 mm |
| Joystick Travel (X/Y) | 2 mm |
| Translation Speed Modes | High (1.4 mm/s), Max (0.7 mm/s), Low (0.1 mm/s) |
| Drive Type | Hydraulic Remote Control |
| Compatibility | Manual and Motorized Injectors |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | DS-U3 |
| Pixel Count | 5.9 MP |
| Distribution Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Pricing | Upon Request |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | Eclipse Ni-E / Ni-U |
| Optical System | CFI60 / CFI75 Infinity-Corrected |
| Illumination | 12V 100W Halogen with Fly-Eye Lens Array |
| Objective Compatibility | CFI Plan Apochromat λ Series (350–850 nm) |
| Fluorescence Performance | Noise Terminator™ High-S/N System |
| Focus Mechanism | Motorized Coaxial Fine/Coarse (Ni-E, 0.05 µm encoder resolution) / Manual with Re-Positioning Function (Ni-U) |
| Stage | Ceramic-Coated Mechanical or Motorized XY (66 × 52 mm, 0.1 µm step) |
| Eyepiece Options | Widefield UW10× (25 mm FOV), Photomask-Compatible, Ergonomic Tilting Binoculars (10°–30°) |
| Compliance | Designed for ISO 10993-compliant sample handling workflows |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIM E |
| Resolution | ≤85 nm (lateral, TIRF-SIM mode) |
| Temporal Resolution | 0.6 s/frame (2D/TIRF-SIM), ~1 s/frame (3D-SIM) |
| Objective Compatibility | CFI Apo TIRF 100× Oil (NA 1.49) |
| Illumination | Multi-laser SIM (up to 5 lasers, e.g., 405/488/561/640/730 nm) |
| Imaging Modes | TIRF-SIM, 2D-SIM, 3D-SIM |
| Optical Sectioning Thickness | Up to 20 µm |
| Axial Resolution | ~300 nm (3D-SIM) |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–ready software platforms |
| Brand | NT-MDT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor (auniontech) |
| Product Category | Domestic |
| Model | NTEGRA Spectra II |
| Pricing | Upon Request |