Moisture Analyzer
Filter
Showing 211–240 of 676 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | AKF-1PLUS |
| Titration Method | Fully Automatic Volumetric Coulometric Hybrid Karl Fischer Titrator |
| Measurement Resolution | 1 ppm |
| Moisture Content Range | 0.001–100% w/w |
| Accuracy | ≤0.3% RSD (2 mL reagent) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Titration Control Precision | 1.0 µL |
| Electrode Type | Dual Platinum Electrode |
| Polarization Voltage Range | 0–2000 mV |
| Polarization Current Range | 0–125 µA |
| Drift Compensation | Auto-tracking & subtraction |
| Display | Monochrome LCD with Chinese interface |
| Dimensions (W×D×H) | 380 × 300 × 330 mm |
| Net Weight | 5.6 kg |
| Power Supply | 95–260 V AC, 50 Hz |
| Ambient Humidity Limit | ≤80% RH |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 30 mg H₂O |
| Measurement Accuracy | ≤ 0.3% (relative) |
| Minimum Dispensing Resolution | 1/2000 of burette volume |
| Electrolysis Current | Auto-controlled, up to 400 mA |
| Detection Sensitivity | 1 µg H₂O |
| Typical Quantitation Range | 10 µg – 10 mg H₂O |
| Maximum Titration Rate | 0.6 mg H₂O/min |
| Endpoint Detection | Visual LED indicator + audible buzzer + automatic stop |
| Display | 5-digit LED |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Titrator |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 0.001–100% (extendable with specialized reagents and accessories) |
| Accuracy | ≤0.15% RSD (at 2 mL titrant consumption) |
| Minimum Dispensing Volume | 0.2 µL |
| Titration Control Precision | 0.2 µL (upgradable via precision burette exchange) |
| Polarization Current Range | ±150 µA |
| Electrode Potential Range | −2000 mV to +2000 mV |
| Valve & Tubing Material | FEP-coated 3-way dual-position solenoid valves with UV resistance and zero-dead-volume design |
| Display | 7-inch capacitive touchscreen (bilingual: English/Chinese) |
| Data Storage | >200 method files, >200 analysis records |
| Interface Options | RS-232C, USB, Ethernet, Web API |
| Environmental Operating Conditions | 5–40 °C, ≤80% RH |
| Dimensions (L×W×H) | 360 × 250 × 320 mm |
| Net Weight | 7.5 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Analyzer |
| Measurement Principle | Microcoulometric Titration (Electrolytic Bromine Generation) |
| Bromine Number Range | 0–300 g Br/100 g sample |
| Bromine Index Range | 1–1000 mg Br/100 g sample |
| Resolution | 0.01 mg Br |
| Accuracy | ±3% (±0.3 mg Br when bromine index < 1 mg Br/100 g) |
| Repeatability | ±3% |
| Titration Control Precision | ±3% (±0.3 mg Br at low-level detection) |
| Power Supply | 220 V AC / 50 Hz |
| Data Storage Capacity | Internal memory supporting >1000 test records |
| Compliance Standards | SH/T 0630, GB/T 11136, ASTM D1492 |
| Endpoint Detection | Potentiometric (dual-platinum electrode system) |
| Electrolyte Compatibility | Benzene-free electrolyte formulations |
| Display | 7-inch color TFT touchscreen interface |
| Average Analysis Time | ≤60 seconds per sample |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-3N |
| Titration Mode | Fully Automatic |
| Resolution | 0.01 µg (H₂O mass) |
| Water Content Range | 3 µg – 100 mg |
| Measurement Accuracy | 0.01 µg |
| Minimum Dispensing Volume | 10 µL |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Electrolytic Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Range | 1 ppm – 100% w/w |
| Accuracy | ≤0.3% RSD |
| Minimum Dosing Increment | 3 µg |
| Repeatability | ≥99.7% |
| Linearity (R²) | ≥0.999 |
| Electrode Configuration | Dual Platinum Electrolysis Electrodes |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C2 |
| Titration Method | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg (as H₂O mass) |
| Resolution | 0.1 µg |
| Measurement Precision | ±1 mV |
| Repeatability | ≥99% RSD |
| Linearity Correlation Coefficient | ≥0.995 |
| Polarization Voltage Adjustment Range | ±10 mV |
| Electrode Configuration | Dual-electrode Coulometric Cell (Generator & Indicator) |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 10 test records |
| External Power Option | 12 V DC input compatible with vehicle power systems and rechargeable Li-ion batteries |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 0.001–100% w/w |
| Measurement Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispensing Volume | 1/2000 of burette capacity |
| Titration Control Precision | 0.01 µg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 0.001–100% w/w |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispense Volume | 1/2000 of burette capacity |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Generator/Electrolysis Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C6 |
| Titration Mode | Fully Automatic Coulometric Titration |
| Measurement Resolution | 0.01 µg |
| Water Content Range | 0.001–100% w/w |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Repeatability | ±0.3% RSD (n=6, 1000 µg water) |
| Linearity Correlation Coefficient | ≥0.999 |
| Electrolysis Electrode | Dual-platinum generator electrode with integrated indicator electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 1 ppm to 100% (w/w) |
| Resolution | 1 µV (electrochemical detection) |
| Accuracy | >99.7% at 1000 µg water |
| Repeatability | >99.7% at 1000 µg water |
| Linearity (R²) | 0.999 |
| Polarization Voltage Range | ±10 mV |
| Electrode System | Dual Platinum Electrolysis Electrodes |
| Current Control Precision | 0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | Designed for GMP/GLP environments with audit trail, user-level access control, and 21 CFR Part 11–ready software architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Titrator |
| Model | AKF-CAS6 |
| Titration Method | Fully Automated Coulometric Titration |
| Measurement Resolution | 0.01 µg / 0.1 ppm |
| Water Content Range | 3 µg – 199 mg (1 ppm – 100% w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of Burette Volume |
| Repeatability | ≥99.7% RSD |
| Linearity Correlation Coefficient | ≥0.999 |
| Electrode System | Dual Platinum Electrolysis Electrode |
| Titration Control Precision | 0.01 µg |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage Capacity | Unlimited (Internal SSD + Optional Network Backup) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3 µg – 199 mg (H₂O mass) |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg pure water) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Repeatability | ±0.3% (for samples containing >1 mg H₂O) |
| Linearity Correlation Coefficient | 0.999 |
| Electrolysis Electrode | Membrane-separated dual-platinum coulometric electrode |
| Titration Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage Capacity | Unlimited (internal flash memory with timestamped audit trail) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Heating Oven |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Control Precision | 0.01 µg H₂O |
| Electrode Type | Electrolytic Electrode |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Combined Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | RSD ≤0.3% |
| Linearity Correlation Coefficient | ≥0.999 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Control Precision | 0.01 µg H₂O |
| Electrode Type | Dual-platinum electrolysis electrode |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage | Internal non-volatile memory with timestamped audit trail |
| Sample Introduction | Heated headspace evaporation with dry carrier gas (N₂ or air), dual-mode sampling (puncture-seal + screw-cap vial handling) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-CH6 |
| Titration Mode | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg |
| Resolution | 0.01 µg |
| Accuracy | ≤0.3% |
| Minimum Electrolytic Delivery | Electrolytic Mode Only |
| Repeatability | ≥99.7% |
| Linearity (R²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Electrode | Dual Platinum Electrolysis Electrode |
| Titration Control Precision | 0.1 µg |
| Power Requirement | 300 W |
| Data Interface | RS232 / USB |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Measurement Resolution | 0.01 µg H₂O |
| Water Content Range | 3 µg – 199 mg H₂O |
| Accuracy | ≥99.7% (at 1000 µg H₂O) |
| Minimum Sample Injection | 3 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Electrode | Dual-platinum electrolysis electrode |
| Titration Current Control Precision | 0.1 mA |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg H₂O |
| Water Content Range | 3 µg – 199 mg H₂O |
| Accuracy | ≥99.7% (at 1000 µg H₂O) |
| Minimum Sample Injection | 3 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrode Type | Electrolytic Electrode |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Supported |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrolysis Electrode Configuration | Dual-electrode coulometric cell |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 220 V / 50 Hz, 300 W |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Sample Introduction | Heated headspace evaporation with dry carrier gas (N₂ or air), dual-mode sampling (puncture-seal + screw-cap vial) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Heating Oven |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Resolution | 0.01 µg H₂O |
| Accuracy | ≥99.7% at 1000 µg H₂O |
| Minimum Sample Injection | 3 µg H₂O |
| Titration Control Precision | 0.01 µg H₂O |
| Titration Mode | Fully Automated Coulometric Titration |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 1 ppm to 100% (w/w) |
| Resolution | 0.01 µg H₂O |
| Accuracy | ≥99.7% at 1000 µg H₂O |
| Minimum Sample Injection | 3 µg |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrode Configuration | Dual Platinum Electrolysis Electrodes |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 220 V / 50 Hz, 300 W |
| Data Storage | Internal non-volatile memory with timestamped audit trail |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic Coulometric Titration |
| Moisture Range | 1 ppm to 100% w/w |
| Measurement Resolution | ±0.1 µA |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | ≥99.7% (n=6) |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Current Control Precision | 0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 1 ppm – 100% water content |
| Resolution | ±0.1 µA |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Control Precision | 0.1 mA |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Sample Positioning | 8-position automated rotary sample carousel |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg |
| Water Mass Range | 3 µg – 199 mg |
| Measurement Precision | ±1 mV |
| Minimum Dispensing Increment | 1/2000 of Burette Volume |
| Repeatability | ≥99% |
| Linearity (R²) | 0.995 |
| Electrode Type | Electrolytic Electrode |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage | Internal Non-Volatile Memory |
| Compliance | SH/T 1770–2010 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Titrator |
| Measurement Resolution | 0.1 µg (H₂O mass) |
| Water Content Range | 3 µg – 199 mg (0.01 µg detection limit for water mass) |
| Accuracy | ≤0.3% |
| Minimum Dispense | 3 µg |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Component | Electrolytic Electrode |
| Titration Control Precision | 0.1 µg |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm – 100% w/w |
| Resolution | 0.1 mV |
| Accuracy | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability | ±0.3% RSD |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Capacity | 10 mL / 20 mL |
| Titration Precision | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automated Coulometric & Volumetric Dual-Mode (Configurable) |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Precision | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability (RSD) | ≤0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity Options | 10 mL & 20 mL |
| Titration Control Accuracy | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GB/T 6283 |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm – 100% w/w |
| Measurement Accuracy | ±0.1 mV |
| Minimum Dispensing Volume | 0.5 µL |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-V1 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Titrator |
| Moisture Content Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Measurement Resolution | 1 ppm |
| Endpoint Detection Precision | ±1 mV |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Water Titration Calibration Curve | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Configuration | 20 mL Long-Life Automatic Burette |
| Burette Dispensing Accuracy | ±0.001 mL (with 20 mL high-precision burette) |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV (endpoint detection) |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |