Physical Property Testing Instruments
Filter
Showing 4021–4050 of 12006 results
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | Pull-Off |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 10 kN |
| Load Cell Accuracy | ±0.01% FS |
| Force Measurement Accuracy | ±0.5% of reading |
| Test Speed Range | 0.001–300 mm/min |
| Effective Test Stroke | ≥200 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 600 × 300 × 300 mm |
| Weight | ~40 kg |
| Key | Max. Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Sweep Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max. Acceleration | 20 g |
| Vibration Axes | Vertical (Z) + Horizontal (X/Y) |
| Waveform | Sine |
| Programmable Segments | 1–15 segments, each with user-defined frequency & duration, loopable |
| Octave Sweep Modes | 5-step logarithmic (low→high, high→low, low→high→low, repeatable) |
| Power Rating | 2.2 kW |
| Table Dimensions (L×W) | 500×500 mm (customizable) |
| Unit Dimensions (L×H×W) | Vertical unit: 500×200×500 mm |
| Horizontal unit | 500×250×500 mm |
| Input Voltage | 1φ AC 220 V, 50/60 Hz |
| Max. Current | 6 A |
| Frequency Resolution | 0.01 Hz, Accuracy: ±0.1 Hz |
| Table Mounting Pattern | Customizable M6/M8 threaded holes |
| Optional Accessories | Magnesium alloy fixtures, FEM-optimized fixtures, circular/square/octagonal extension tables, thermal isolation pads for environmental chamber integration |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Load Capacity Options | 50 / 100 / 200 / 500 / 1000 kgf |
| Force Resolution | 1/100,000 (1/250,000 for ≤10 kN models) |
| Force Accuracy | ≤0.5% FS (≤0.25% FS for ≤10 kN models) |
| Crosshead Travel | 1000 mm (excl. grips) |
| Test Speed Range | 5–300 mm/min (software-controlled, stepless) |
| Drive System | Panasonic AC servo motor + servo driver |
| Transmission | Precision ground ball screw + timing belt + Liming gearbox |
| Load Cell | Explosion-proof high-precision strain-gauge transducer with auto-thermal compensation, zero drift <0.01% FS/°C, repeatability ±0.03% FS, overload capacity 150% FS |
| Position Feedback | 2500 PPR optical encoder |
| Safety Features | Mechanical stroke limiter, software-based load upper-limit alarm, automatic halt on specimen rupture |
| Data Acquisition | PC-based real-time control and analysis, curve plotting (stress–strain, load–displacement), peak hold, auto-stop on break, unit switching (g/kg/N/kN/lbf), report generation & export (PDF/Excel) |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | 2500S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/m·K |
| Temperature Range | 30 K to 1000 °C |
| Accuracy | ±3% |
| Repeatability | <1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 500 × 450 × 320 mm |
| Probe Diameter Options | 2–29.4 mm |
| Additional Outputs | Thermal Diffusivity (±5%), Volumetric Heat Capacity (±7%) |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS 1500 |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–20 W/m·K |
| Temperature Range | −50 to 750 °C |
| Accuracy | < ±3% |
| Repeatability | < ±1% |
| Sample Forms | Solids, Powders, Pastes, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 50 × 40 × 30 cm |
| Probe Sizes | 2–29.4 mm |
| Compliance | ISO 22007-2 |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS 2500S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/m·K |
| Temperature Range | 30 K to 1000 °C |
| Accuracy | < 3% |
| Repeatability | < 1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 500 × 450 × 320 mm |
| Compatible Modules | Basic, Thin-Film, Plate, Anisotropy, Single-Sided, Specific Heat |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS3500 |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/(m·K) |
| Thermal Diffusivity Range | 0.01–1200 mm²/s |
| Volumetric Heat Capacity Range | up to 5 MJ/(m³·K) |
| Temperature Range | 30 K to 1000 °C |
| Minimum Test Duration | 0.1 s |
| Accuracy | < 3% |
| Repeatability | < 1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Sample Dimensions (Min) | 2 mm diameter × 0.5 mm thickness (bulk), 8 mm diameter × 0.1 mm thickness (thin films) |
| Dimensions (L×W×H) | 600 × 460 × 330 mm |
| Compliance | ISO 22007-2:2008 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HPA-300 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Heat Flow Method |
| Dimensions (L×W×H) | 750 × 650 × 1100 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.015–100 W/(m·K) |
| Repeatability | ±1% |
| Maximum Test Temperature | 300 °C |
| Applied Load Range | 0–1000 N (adjustable) |
| Specimen Size | φ50 × 100 mm or φ37.5 × 100 mm |
| Cooling Base Temperature | 20 °C (integrated constant-temperature water bath) |
| Axial Temperature Sensors | 4 points |
| Radial Temperature Sensors | 3–6 gradient points |
| Heating Power | 60 W |
| Software | Fully Automated Acquisition & Analysis Suite with Touchscreen Interface |
| Brand | HPG |
|---|---|
| Origin | Guangdong, China |
| Model | IPC-650M |
| Channel Capacity | 168 measurement channels |
| Temperature Channels | 10 independent thermocouple inputs |
| Module Support | Up to 8 modular units (resistance + temperature modules) |
| Test Current Range | 1 mA – 5 A (selectable per channel) |
| Measurement Method | Four-wire Kelvin sensing with bidirectional current reversal |
| Compliance | CE certified |
| Data Management | SQL-based database with timestamped audit trail |
| Power Backup | Integrated UPS support |
| Traceability | Calibration traceable to NIST-equivalent national standards |
| Regulatory Context | Designed for GLP/GMP-aligned production validation and reliability testing |
| Brand | HPG |
|---|---|
| Origin | Guangdong, China |
| Model | IPC-650S |
| Voltage Ranges | 1.0–1000 V DC (configurable in 0.01–1.0 V steps) |
| Resistance Range | 1 × 10⁶ – 1 × 10¹³ Ω |
| Resistance Accuracy | ±5.0% (1×10⁶–1×10¹⁰ Ω, at 5 V), ±10% (1×10¹⁰–1×10¹¹ Ω), ±15% (1×10¹¹–1×10¹² Ω), ±20–30% (1×10¹²–1×10¹³ Ω) |
| Current Monitoring | 0.1 µA – 500 µA, up to 10 readings/sec per channel |
| Test Speed | 3.5 s/channel (256-channel full test ≤ 10 min) |
| Bias Voltage Range | –100 V to +1000 V DC with polarity reversal |
| Environmental Groups | 2–4 independent test chambers (64 channels/group) |
| Compliance | IPC-TM-650 2.5.10, 2.6.11, 2.6.3.7, 2.6.14 |
| Software | GLP-compliant, audit-trail enabled, remote monitoring via web interface and mobile app |
| Dimensions | 1800 × 600 × 1000 mm (H × W × D) |
| Weight | ~280–350 kg |
| Input Power | AC 220 V ±10% |
| Brand | HPHC |
|---|---|
| Origin | Beijing, China |
| Model | CM8310 Series |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Gas Inlet Ports | 8 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.001 °C |
| Heating Rate | 1 °C/min |
| Pressure Range | Atmospheric |
| Test Capabilities | TPD, TPR, TPO, Pulse Chemisorption (Metal Dispersion), Vapor Adsorption, BET Single-Point Surface Area, Multi-Component Competitive Adsorption |
| Detector | Tungsten-Rhenium Alloy Thermal Conductivity Detector (TCD) |
| TCD Count | 1 |
| Mass Flow Controllers | 2 |
| Exhaust Flow Meter | 1 |
| Electric 6-Port Valve | 1 |
| Electric 4-Port Valves | 2 |
| Furnace Control | Dual-point (“Bed Temp” & “Furnace Temp”) |
| Sample Temperature Sensing | Independent RTD or Thermocouple |
| Internal Line Insulation | Up to 300 °C |
| Gas Flow Range | 5–100 SCCM |
| Tubing Material | 1/8″ SS316 |
| Optional Accessories | Integrated Vapor Generator (Continuous & Pulsed Modes), Customizable LOOP Volumes (≥3 Options), Cold Trap (1), Forced-Air Cooling System (1) |
| Brand | Hprobe |
|---|---|
| Origin | France |
| Model | IBEX-300 |
| Wafer Compatibility | 100–300 mm |
| Max In-Plane (XY) Field | 350 mT |
| Max Perpendicular (Z) Field | 550 mT |
| Field Uniformity (±1 mm) | ±1% |
| Field Resolution (XY/Z) | 0.05 / 0.02 mT |
| Angular Resolution | 0.02° |
| Field Sweep Sampling Rate | < 50 kHz |
| R-H Loop Acquisition Time | < 100 ms |
| Z-Gap Adjustment Range | 500 µm – 5 mm |
| Integrated Instrumentation | Dual-Channel 40 MHz AWG, Sub-200 ps Pulse Generator, SMU (20 mV / 1 nA min ranges), 18-bit DMM (10 nV resolution), Switch Matrix & DAQ Support |
| Software Modes | Calibration / Engineering / Production |
| Compliance | Designed for ASTM F3092, ISO/IEC 17025-aligned test workflows, supports GLP/GMP audit trails via optional 21 CFR Part 11-compliant software module |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HRS-5A |
| Pricing | Available Upon Request |
| Brand | Huafeng |
|---|---|
| Origin | Hunan, China |
| Model | DIL0806A-1400 |
| Temperature Range | RT to 1400 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Displacement Resolution | 0.1 µm |
| Atmosphere Options | Vacuum and Controlled Gas |
| Sample Holder Material | Alumina |
| Maximum Displacement Range | 5000 µm |
| Sample Dimensions | Ø5–8 mm × 25–50 mm (cylindrical or rectangular) |
| Thermal Expansion Coefficient Resolution | 0.001 × 10⁻⁶ K⁻¹ |
| System Measurement Uncertainty | ±0.1% |
| Interface | USB 2.0 |
| Compliance | ASTM E831, ASTM D696, ASTM D3386, DIN 51045 |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-3090PM |
| Price Range | USD 2,800 – 7,000 |
| Display | 800×480 Color TFT Touchscreen (Bilingual: Chinese/English) |
| Sample Positions | 4 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Built-in Air Source | ≥400 mL/min |
| Gas Diffuser Permeability | 3000–6000 mL/min at 2.4 kPa (250 mmH₂O) |
| Heating Power | ≤2500 W |
| Cylinder Specification | 1000 mL (Dedicated Calibration Cylinder) |
| Power Supply Options | AC 220 V / 50–60 Hz |
| Dimensions (L×W×H) | 991 mm × 422 mm × 710 mm |
| Net Weight | ≤50 kg (dry) |
| Operating Environment | 10–35 °C, ≤93% RH (non-condensing), vibration-free, non-corrosive atmosphere, minimal electromagnetic interference |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-3100MD |
| Price Range | USD 1,400 – 7,000 |
| Application Field | Petroleum & Liquid Hydrocarbon Density Testing |
| Instrument Type | Buoyancy-Based Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid Only |
| Density Measurement Range | 0–2 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Control Range | Ambient to 100 °C (user-selectable, ±0.2 °C stability) |
| Minimum Sample Volume | 50 mL |
| Dual-Bath Capacity | 2 independent test positions |
| Stirring Speed | 1250 rpm |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Heating Power | Main Heater 800 W + Auxiliary Heater 300 W |
| Dimensions (L×W×H) | 500 × 305 × 550 mm |
| Weight | 25 kg |
| Interface Options | RJ45 Ethernet, USB 2.0 |
| Compliance | GB/T 1884–2000 |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HK-3150ZL |
| Measurement Range | 0–100 mN/m |
| Accuracy | ≤ ±0.3 mN/m |
| Sensitivity | 0.1 mN/m |
| Temperature Measurement Range | 0–50.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Motor Descent Speed | 0.3–0.4 mm/s |
| Data Storage Capacity | 500 test records |
| Power Supply | 85–264 VAC, 50/60 Hz |
| Power Consumption | ≤50 W |
| Dimensions (L×W×H) | 190 × 300 × 435 mm |
| Weight | 7.5 kg |
| Interface | RJ45, USB |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-vibration, low-EMI environment |
| Brand | HUAXI INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XD50 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0003 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Temperature Control Range | 5–65 °C |
| Display | 7-inch Full-Color Touchscreen |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCYQ-STA-1550 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Options | N₂, O₂ |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Brand | NYX (NTX) |
|---|---|
| Origin | USA |
| Manufacturer | NYX Instruments |
| Product Type | Imported Laboratory Combustion Burner |
| Model | H-6240C |
| Application | Flame Resistance Testing of Protective & Textile Materials |
| Repeatability Error | ±0.1 s |
| Compliance | ASTM D6413, ISO 15025, NFPA 2112, GB/T 5455 |
| Intended Use | Standardized Vertical Flame Propagation Testing |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PCY-SL-30 |
| Price Range | USD 1,400–7,000 |
| Temperature Range | −30 °C to 30 °C |
| Heating Rate | 5 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Diameter | 6–10 mm |
| Measurement Range | 5 mm |
| Resolution | 1 µm |
| Atmosphere Options | Air, Vacuum, Inert Gas |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (PRC) |
| Model | DSC0901 |
| Pricing | Available Upon Request |
| Differential Heat Range | ±2000 µV |
| DSC Power Range | ±10, ±20, ±50, ±100, ±160, ±200 mW (auto-switching) |
| Temperature Range Options | RT–450°C, RT–1150°C, RT–1400°C, RT–1650°C |
| Heating Rate | 0.1–30 °C/min (programmable) |
| Temperature Control Modes | Ramp, Isothermal, Cooling, PID-regulated |
| Base Resolution | 2 µg |
| Sensitivity | 10 µg |
| TGA Capacity | 1–1000 mg (selectable ranges) |
| DTG Range | 0.1–10 mg/min (selectable) |
| Gas Flow Control | Dual-channel mass flow controllers (N₂, O₂), ≤200 mL/min |
| Max Sample Load | 2 g |
| A/D Resolution | 24-bit |
| Data Output | Printer, chart recorder, PC interface |
| Power Supply | 220 V AC ±1 Hz, 50 Hz |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MD-2 / MD-4 / MD-5 |
| Price Range | USD 700–1,400 (FOB) |
| Application Scope | General-purpose solid density measurement |
| Instrument Type | Buoyancy-based density analyzer |
| Form Factor | Benchtop laboratory instrument |
| Sample Type | Non-porous solids (glass, ceramics, sintered materials) |
| Density Range | 1.1–3.3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.01 °C |
| Horizontal Bath Uniformity | ±0.01 °C |
| Vertical Bath Uniformity | ±0.03 °C |
| Heating Rate | ≥0.1 °C/min (±0.02 °C/min) |
| Magnetic Stirring | Stepless speed control, 1–1000 rpm |
| Power Supply | 220 V AC, 1000 W |
| Compliance Standard | GB/T 14901–1994 (Glass — Determination of Density by Sink-Float Method) |
| Minimum Sample Mass | 1 g |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥6000 lm |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥6000 lm |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Tray Size | 200 × 200 mm (net) |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Spot Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥ 6000 lumens |
| Light Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Carriers | 200 × 200 mm transparent tray (for pellets) and direct platform placement (for films) |
| Compliance | ASTM D7252, ISO 18064, GB/T 29187, USP <788> (particle inspection principles), GLP-compliant data audit trail support |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-BS-1908 |
| Price | Upon Request |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Tray Dimensions | 200 × 200 mm (net usable area) |
| Optical Magnification | >20× |
| Light Output | ≥6000 lumens |
| Light Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Overall Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Spot Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Detection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥ 6000 lumens |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Tray Size | 200 × 200 mm (net usable area) |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 Powder Particle |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Scanning Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Source | 24 V / 60 W |
| Illuminance | ≥ 6000 lm |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |