Physical Property Testing Instruments
Filter
Showing 8461–8490 of 12412 results
| Brand | PULUODY |
|---|---|
| Model | OPC-1800D |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm |
| Channel Count | 1000 adjustable size channels |
| Resolution | <10% (per JJG 1061 or NIST-traceable latex standard calibration) |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Sampling Precision | <±1% |
| Flow Rate (Sample) | 5–60 mL/min |
| Flow Rate (Flush) | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Operating Ambient | −15–50 °C |
| Interface | RS232, RS485-to-USB, USB, MODBUS RTU |
| Output | 4–20 mA analog, digital report (particles/mL + ISO/USP/NAS grade) |
| Power | 100–265 VAC, 50–60 Hz |
| Compliance | GB/T 11446.9–2013, USP <788>, USP <789>, EP 8.0, JP 16, ISO 21501-4, ISO 11171, ISO 4406, NAS 1638, ASTM F312-19, JJG 1061 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC-2300 |
| Price | ¥98,000 |
| Dispersion Method | Dry/Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 2–750 µm |
| Repeatability | ±5% |
| Measurement Time | 0.01 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Range | 2–750 µm (configurable up to 1000 µm) |
| Size Resolution | 0.1 µm |
| Accuracy | <±3% typical |
| Counting Resolution | 10% |
| Coincidence Error | ≤5% |
| Maximum Concentration | 9,999,999 particles/mL |
| Sampling Flow Rate | 6–500 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | 4–20 mA analog, RS232/RS485 digital |
| Data Storage | Unlimited (internal + external SD/USB support) |
| Alarm Functions | Particle count threshold, sensor health diagnostics |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300A |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Eighth-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Range | 2–750 µm (configurable to 5–1000 µm) |
| Resolution | 0.1 µm |
| Resolution Accuracy | ≤10% |
| Measurement Accuracy | <±3% typical |
| Coincidence Error | ≤5% |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | 4–20 mA analog, RS232/RS485 digital |
| Data Storage | Unlimited (onboard + external export) |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300B |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Seventh-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Ranges | A: 2–100 µm |
| B | 1–150 µm |
| C | 1–450 µm |
| H | 0.1–1.0 µm |
| I | 0.2–2.0 µm |
| J | 0.5–50.0 µm |
| K | 2–750 µm (or up to 1000 µm / 1000 µm) |
| L | 40–1000 µm (or 10–2000 µm) |
| N | 50–1000 µm |
| M | 100–2000 µm |
| Sizing Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Operating Pressure | 0–0.6 MPa (standard) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | RS232, 4–20 mA analog, optional Ethernet/Modbus TCP |
| Housing Rating | IP65 industrial enclosure |
| Compliance | Supports ISO 21501-4, USP <788>, ASTM F312-19, ISO 4406:2017, and customizable regulatory logic for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | OPC-2300D |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Range | 2–750 µm (configurable up to 1000 µm) |
| Size Channels | Up to 1000 user-defined bins (e.g., 8/16/32 standard channels) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h |
| Pressure Rating | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure-reducing valve) |
| Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Analog Output | 4–20 mA |
| Digital Interface | RS232 / RS485 |
| Data Storage | Unlimited (onboard + external export) |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Compliance Support | ISO 4406, ISO 11171, NAS 1638, ASTM D6786, USP <788>, EP 2.9.19 |
| Power Supply | 9–30 VDC or 220 VAC |
| Alarm Functions | Particle count threshold, sensor health diagnostics |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300M |
| Price | USD 13,800 (FOB) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Generation | 8th-Generation |
| Measuring Range | 2–750 µm (configurable up to 1000 µm) |
| Size Channels | 1000-user-definable channels, standard presets: 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Resolution | 0.1 µm |
| Resolution Accuracy | ±10% (per ISO 21501-4) |
| Counting Accuracy | <±3% typical (NIST-traceable calibration) |
| Coincidence Error | ≤5% at 9,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h (programmable) |
| Flow Rate | 6–500 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), 0–31.5 MPa (with optional pressure regulator) |
| Fluid Temperature Range | −10 °C to +80 °C |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, AC fine test dust, MTD |
| Output Interfaces | 4–20 mA analog, RS232, RS485 |
| Data Storage | Internal non-volatile memory + external USB/SD logging |
| Display | Backlit LCD with membrane keypad |
| Enclosure Rating | IP65 (optional IP67) |
| Power Supply | 9–30 VDC or 220 VAC |
| Alarm Functions | Particle count threshold, sensor fault, flow interruption, temperature/pressure out-of-range |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC-3 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GJB 420B, GB/T 14039, GOST 17216 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination grade |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC-Ex |
| Instrument Type | Optical Particle Counter |
| Explosion Protection | Intrinsic Safety (Ex ia IIC T4 Ga) |
| IP Rating | IP40 to IP65 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 1–150 µm |
| Channel Configurations | Fixed 8-channel or 16-channel (customizable 1–100 µm) |
| Calibration Standards Supported | NAS 1638 (00–>12), ISO 4406 (00–>28), GJB 420B (00–>12), GOST 17216 (00–>17), GB/T 14039, ISO 11171, MIL-STD-1246, SAE AS4059, IP 564/565, DL/T 432 & 1096, JB/T 9737, GB/T 18854 |
| Operating Pressure | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure-reduction valve) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt (online) |
| Analog/Digital Outputs | RS232, RS485, 4–20 mA, 0–5 V (customizable with alarm relay) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB-based contamination grade |
| Compliance | Meets IEC 60079-0/-11 for intrinsic safety |
| aligned with ISO 4402 (historical) and ISO 11171 | 2010 reference calibration protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | OPCI Series |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1–150 µm |
| Repeatability | ±1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Model | P-III |
| Instrument Type | Optical Surface Particle Counter |
| Detection Principle | Light Scattering (Laser-Based) |
| Particle Size Channels | Configurable across 6 channel sets (A–F), ranging from 0.1 µm to 25.0 µm |
| Size Accuracy | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | ≤ 5% |
| Flow Rate Options | 2.83 L/min or 28.3 L/min |
| Sampling Duration | 3–60 s (user-selectable) |
| Operating Temperature | −40 °C to +120 °C |
| Environmental Operating Range | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1, ISO 14644-9 |
| Data Interface | RS232, RS485, LAN, USB |
| Audit Trail & User Access Control | Yes |
| Detection Modes | Count, Mass, Net Efficiency |
| Alarm Output | Customizable count/mass thresholds |
| Storage | Real-time and scheduled (unlimited capacity) |
| Optional Accessories | Straight probe (2″), 90° angled probe, multifunctional surface probe (UK4400301) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PDM-301A |
| Instrument Type | Laboratory Benchtop Digital Densimeter |
| Measurement Principle | Oscillating U-Tube Method |
| Sample Type | Liquids Only |
| Density Range | 0.0000–3.0000 g/cm³ |
| Density Resolution | ±0.0001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Temperature Control Range | 15–30 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 10 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D3505, ISO 12185, GB/T 29617, GB/T 2013, SH/T 0604, SN/T 2383, DB/T 1231, JJG 1058 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 0.01 µm – 1000 µm (configurable sensor modules) |
| Channel Resolution | Up to 1000 user-definable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Viscosity Handling | ≤ 450 mm²/s |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Pressure Range | −0.08 to 0.8 MPa (integrated positive/negative pressure pretreatment) |
| Operating Temperature | Ambient to 65 °C (sample), 0–50 °C (ambient) |
| Data Storage | 3000 tests onboard |
| Compliance Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, DL/T 432, GJB 380, GJB 420A/B, MIL-STD-1246, ASTM D6786, USP <788> & <789> (via optional configuration) |
| Software Platform | PULL 8.1 Multi-Language Analysis Suite (English, Chinese, Japanese, Korean, German, French, Spanish, Russian, Arabic, Portuguese) |
| Output Interface | RS232, integrated thermal printer, capacitive touchscreen (7″ color LCD), dual-input (touch + keypad), iPad-compatible data acquisition module |
| Brand | PULUODY |
|---|---|
| Model | PLD-0201 |
| Type | Optical (Light Obscuration) Particle Counter |
| Measurement Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Detection Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channels | 8 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min |
| Test Duration | Adjustable, down to 12.5 s |
| Viscosity Limit | ≤350 cSt |
| Operating Temperature | Ambient to 65°C |
| Pressure Range | −0.6 to +0.7 kPa (integrated dual-pressure pretreatment system) |
| Compliance Standards | ISO 4406, NAS 1638, GJB 420B, GJB 380, GB/T 14039, GB/T 18854, ISO 11171, ASTM D6786 |
| Calibration Traceability | Certified by China National Defense Science & Technology Commission Level-1 Particle Metrology Station No. 116 |
| Data Output | Real-time particle count per channel, size distribution histogram, contamination grade assignment, RS232 interface, built-in thermal printer |
| Software | P6.4 Analysis Suite (PC & embedded industrial control versions) |
| Control Interface | Integrated capacitive touchscreen LCD |
| Auto-Cleaning Function | Yes |
| Power | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measuring Range | 0.5–1000 µm (sensor-dependent) |
| Compliance Standards | ISO 4406, NAS 1638, MOOG, DL/T 1096, GJB 380, DL/T 432, ISO 11500 |
| Control System | Integrated Industrial PC or Embedded Controller |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Display | Touchscreen LCD with Dual Input (Touch + Keypad) |
| Data Output | RS232 Serial Interface |
| Built-in Printer | Yes |
| Software | P6.4 Particle Analysis Suite (Embedded & PC Versions) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1–450 µm |
| Repeatability | <5% |
| Measurement Time | 20 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Rate | 5–60 mL/min |
| Rinse Flow Rate | 10–100 mL/min |
| Sample Volume Accuracy | ±1% |
| Test Duration | Adjustable, nominal 20 s per measurement |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-conditioning system) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C (sample), 0–50 °C (ambient) |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests on embedded industrial PC |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, ASTM D6786, DL/T 432, DL/T 1096, GJB 420A/B, GJB 380, MIL-STD-1246, MOOG, USP <788>, and GB/T 14039 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Standard Compliance | ISO 4406, ISO 11171, NAS 1638, GB/T 18854, JJG/T 066, GJB 420B, DL/T 432 |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 adjustable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + electromagnetic flow regulation |
| Viscosity Handling | ≤ 450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 MPa to +0.8 MPa |
| Sampling Volume Accuracy | ±1% |
| Test Duration | Configurable (standardized at 20 s per ISO 11500) |
| Data Storage | 3000 onboard tests |
| Interface | RS232, touchscreen GUI, integrated thermal printer |
| Software | PULL 8.1 multi-language platform (English, Chinese, Japanese, Korean, etc.), FDA 21 CFR Part 11–ready audit trail mode optional |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Laser-Based Particle Counter |
| Detection Principle | Light Scattering (Dual-Laser Narrow-Beam Sensor, 8th Generation) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854, JJG 1061 |
| Compliance Standards | ISO 4406:1999/1987, NAS 1638, MOOG, DL/T 1096, ISO 11218, GJB 380, DL/T 432, ISO 11500 |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Detection Range | 0.03–3000 µm (sensor-dependent) |
| Channel Configuration | Up to 1000 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Data Storage | 3000 tests on embedded industrial PC |
| Interface | RS232 |
| Output | Real-time particle count/mL, size distribution histogram, contamination grade per ISO/NAS, built-in thermal printer |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Control | Industrial PC or integrated touch-enabled HMI with color LCD |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201 (Serial: 02010086) |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Viscosity Limit | ≤450 mm²/s |
| Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (rinse) |
| Pressure Range | −0.08 to 0.8 MPa |
| Operating Temperature | Ambient to 65 °C |
| Data Storage | 3000 tests onboard |
| Compliance Standards | ISO 11171, ISO 4406, ISO 4402, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, GJB 420A/B, DL/T 432, DL/T 1096, MIL-STD-1246, ASTM D6786 |
| Software Platform | PULL 8.1 multi-language analytical suite (English, Chinese, Japanese, Korean, etc.) |
| Output Interface | RS232, integrated thermal printer, touchscreen GUI, iPad-compatible data acquisition |
| Calibration Support | ACFTD & MTD traceable calibration |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 18854, JJG/T 066 |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent) |
| Channel Count | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Sample Flow Control | Dual-mode precision piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Pressure Range | −0.08 to 0.8 MPa |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temp Range | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | ASTM D6786, ISO 11500, GJB 380, DL/T 432, MIL-STD-1246, GJB 420A/B, DL/T 1096 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 8th-Generation Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Capacity | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Sample Volume Accuracy | ±1% |
| Pressure Range | −0.08 to 0.8 MPa |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature | 0–50 °C |
| Power Supply | 220 V, 50 Hz, <80 W |
| Compliance Standards | ISO 11171, ISO 4406, ISO 4402, NAS 1638, GB/T 14039, GB/T 18854, JJG/T 066, DL/T 432, GJB 420A/B, ASTM D2276, MIL-STD-1246, USP <788>, USP <789> |
| Software Platform | PULL 8.1 Industrial Control & Analysis System (multi-language: English, Chinese, Japanese, Korean, etc.) |
| Data Storage | 3000+ tests on embedded industrial PC |
| Output Interface | RS232, integrated thermal printer, color LCD touchscreen (dual touch/keyboard input), iPad-compatible data acquisition module |
| Calibration Support | ACFTD & MTD traceable calibration |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Model | PLD-0201I |
| Measurement Principle | Light Obscuration (LO) per ISO 11171:1999 / ISO 4406:1999 / NAS1638 / GJB420B |
| Laser Sensor | 7th-Generation Narrow-Beam Laser Detector (PCF-7A) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channels | 8 user-configurable size thresholds |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min via precision piston pump with electromagnetic flow regulation |
| Pressure Range | –0.06 to 0.7 MPa (dual positive/negative pressure pre-treatment system) |
| Viscosity Handling | up to 350 cSt |
| Max Particle Concentration | 10,000 particles/mL (≤5% coincidence error) |
| Test Duration | Adjustable, default 12.5 s |
| Operating Temp | Ambient to 65 °C |
| Ambient Temp | 0–50 °C |
| Power | 220 V AC, 50 Hz, <80 W |
| Calibration Compliance | GB/T 18854–2002, ISO 11171:1999, JJG 066–95 |
| Data Output | Real-time particle count/size distribution, histogram, ISO 4406 & NAS1638 contamination grade assignment, built-in thermal printer |
| Interface | RS232 serial port |
| Software | P6.4 Analysis Suite (integrated LabPC7 platform) |
| Regulatory Support | GLP-compliant audit trail, FDA 21 CFR Part 11-ready configuration (optional), traceable calibration certificate available from National Defense Science & Technology Industry First-Class Particle Metrology Station (No. 116) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Detection Channels | 8 user-configurable channels |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Sample Flow Rate | 5–60 mL/min |
| Sample Volume Accuracy | ±1% |
| Test Duration | Adjustable, default 12.5 s |
| Viscosity Limit | ≤350 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V, 50 Hz, <80 W |
| Calibration Standard | GB/T 18854–2002 (equivalent to ISO 11171:1999) |
| Compliance Standards | ISO 4406:1999, NAS 1638, GJB 380, GJB 420 |
| Data Interface | RS232 |
| Control System | Integrated Industrial PC or External PC |
| Software | P6.4 Particle Analysis Suite (Standalone & PC Edition) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PLD-0201 (Latest) |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171:1999, GB/T 18854–2002, JJG 066–95 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171) |
| Particle Size Range | 1–450 µm |
| Channel Resolution | 1000 adjustable channels (user-selectable 8-channel configuration) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Sample Volume Precision | ±1% |
| Flow Rate | 5–60 mL/min |
| Test Duration | Adjustable down to 12.5 s |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pre-treatment system) |
| Max. Viscosity Handling | ≤350 cSt |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Photometric Blockage |
| Measurement Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Number of Adjustable Channels | 8 |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Pressure Range | −0.6 to +0.7 bar (integrated positive/negative pressure pretreatment system) |
| Viscosity Handling | up to 350 cSt |
| Operating Temperature | ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Calibration Compliance | GB/T 18854–2002 (equivalent to ISO 11171:1999), JJG 066–95 |
| Standards Supported | ISO 4406, NAS 1638, GJB 380, GJB 420, GB/T 14039–2002 |
| Data Output | Real-time particle count per channel, histogram, contamination grade assignment, RS232 interface, built-in thermal printer |
| Software | P6.4 Particle Analysis Suite (embedded & PC versions) |
| Regulatory Traceability | Calibrated and certified by the AVIC Particle Metrology Testing Station (National Defense Science & Technology Industry First-Class Particle Metrology Station No. 116) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-008 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 0.01 µm to 1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa |
| Compliance Standards | ISO 4406, NAS 1638, ISO 11171, ISO 4402, GB/T 14039, DL/T 432, GJB 420A/B, ASTM D2276, MIL-STD-1246, USP <788>, and 510+ global particle contamination standards |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-01 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Photometric Blocking |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-treatment system) |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171/GB/T 18854) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (cleaning) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | –0.08 to 0.8 MPa |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |