Physical Property Testing Instruments
Filter
Showing 8491–8520 of 12411 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter |
| Model | PLD-0201-04 |
| Measurement Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406, NAS 1638, ISO 11171, ISO 4402 |
| Sample Flow Control | Dual-precision piston pump + electromagnetic flow regulation |
| Adjustable Sizing Channels | User-definable threshold settings with built-in pulse-height calibration |
| Sample Handling | Integrated pressurized/depressurized sampling chamber with stirring and degassing functions |
| Display & Interface | 7-inch color TFT-LCD touchscreen with dual-input (touch + keypad) |
| Data Output | RS232 serial port, on-device thermal printer, iPad-compatible data acquisition |
| Software Architecture | Decoupled analysis & calibration modules |
| Calibration Support | Traceable to GBW reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PLD-0201-16-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | GB/T 18854–2002 (ISO 11171:1999, JJG 066–95) |
| Reporting Standards | ISO 4406, NAS 1638, GB/T 14039, DL/T 1096, ISO 4402 |
| Measurement Range | 1–450 µm (configurable sub-ranges: 2–100 µm, 1–150 µm, 2–200 µm) |
| Channel Count | 1000 size bins |
| Repeatability | <5% CV (at ≥1000 counts per sample) |
| Sample Flow Rate | 10–60 mL/min (online), 20–150 mL/min (flush) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Fluid Temperature | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Output Interfaces | RS232, 4–20 mA analog, customizable alarm relay |
| Data Storage | 3000 records (100 full test reports) |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Fully compatible with ISO/IEC 17025-aligned calibration workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-3 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) / Photometric Blockage |
| Calibration Standards | ISO 11171, ISO 4406, NAS 1638, GB/T 18854, JJG/T 066 |
| Detection Channels | 1000 adjustable size bins |
| Flow Control | Precision piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Range | 1 mL to unlimited (user-defined) |
| Display | Color LCD touchscreen with dual input (touch + keypad) |
| Data Output | RS232 serial interface, built-in thermal printer, iPad-compatible data acquisition |
| Software | PULL 8.1 multi-language platform (English, Chinese, Japanese, Korean, etc.), GLP-compliant audit trail, 3000-test local storage |
| Compliance | Supports FDA 21 CFR Part 11-ready configuration (via optional software module), ISO/IEC 17025 traceable calibration protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-7 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, DL/T 1096, GJB 380 |
| Measuring Range | 1–1000 µm (sensor-dependent |
| Sample Volume | 1 mL to unlimited (user-defined) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Reporting | Particles/mL + ISO 4406/NAS 1638 contamination codes |
| Data Interface | RS232 |
| Control System | Integrated industrial PC with embedded OS |
| Display | Touchscreen LCD with dual input (touch + keypad) |
| Software | P6.4 Analysis Suite (embedded & PC versions) |
| Compliance | GB/T 18854, JJG/T 066, JJG 1061, ISO 11500, DL/T 432 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-8 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Minimum Detectable Size | 0.01 µm (nano-range mode) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, ASTM D6786, DL/T 432, DL/T 1096, GJB 380, GJB 420A/B, MIL-STD-1246, GB/T 14039, GB/T 18854 |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Data Storage | 3,000 tests (embedded industrial PC) |
| Interface | RS232 |
| Output | Particle count per mL, size distribution histogram, contamination grade (ISO/NAS), printable reports |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-8 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (configurable sensor |
| typical operational range | 0.5–600 µm) |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Reporting Standards | ISO 4406:1999/2017, NAS 1638, DL/T 1096, MOOG, ISO 11218 |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Sample Handling | Integrated pressure-assisted degassing, magnetic stirring, and high-viscosity compensation |
| Display & Interface | 7-inch TFT-LCD touchscreen with dual input (touch + keypad), embedded OS, thermal printer |
| Data Output | RS232 serial interface, histogram, size distribution curve, particle count per mL, contamination grade |
| Software | P6.4 Analysis Suite (embedded & PC versions) |
| Compliance Support | FDA 21 CFR Part 11 audit trail (via PC software), GLP/GMP traceability mode |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-DL |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | 1000 channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (flushing) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa |
| Data Storage | 3000 tests (onboard industrial PC) |
| Interface | RS232 |
| Compliance | ISO 4406, NAS 1638, DL/T 432, DL/T 1096, GJB 420B, ASTM D6786, MIL-STD-1246, MOOG, ISO 11218 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0201-GT |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump + electromagnetic flow regulation (5–60 mL/min) |
| Viscosity Handling | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | −0.08 to 0.8 MPa (dual-polarity pre-treatment system) |
| Data Storage | 3000 tests onboard |
| Compliance | ASTM D6786, ISO 4406:2017, NAS 1638, DL/T 1096, GJB 420B, MOOG, ISO 11218 |
| Brand | PULUODY |
|---|---|
| Model | PLD-0201L |
| Measurement Principle | Light Obscuration (LO) / Optical Blockage |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump with electromagnetic flow regulation (5–60 mL/min) |
| Pressure Range | −0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment) |
| Viscosity Limit | ≤350 cSt (mm²/s) |
| Operating Temperature | Ambient to 65 °C |
| Environmental Temp. | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Compliance Standards | ISO 4406:1999, NAS 1638, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95, GJB 380, GJB 420 |
| Data Interface | RS232 serial port |
| Built-in Printer | Yes |
| Calibration Traceability | Certified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PLD-0201NEW |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Laser Sensor | 6th-generation narrow-beam laser detector |
| Sensitivity | 1 µm (per ISO 4402) / 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Measurement Range | 1–450 µm |
| Number of Adjustable Channels | 8 |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Sampling Volume | 1 mL to unlimited (user-definable) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment) |
| Max. Fluid Viscosity | ≤350 mm²/s |
| Operating Temperature | Ambient to 65°C |
| Ambient Temperature Range | 0–50°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Compliance Standards | ISO 4406, NAS 1638, GJB 380, GJB 420, GB/T 14039–2002, GB/T 18854–2002 (equivalent to ISO 11171:1999), JJG 066–95 |
| Calibration Traceability | Certified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station) |
| Data Output | Real-time particle count per channel, contamination grade assignment, histogram generation, built-in thermal printer |
| Interface | RS232 serial port for external PC connection and data archiving |
| Software | P6.4 Particle Analysis Suite (integrated embedded OS + optional PC version) |
| Auto-Cleaning Function | Yes |
| Sample Pretreatment | None required |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PLD-0203 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171, ACFTD/ISO 4402 |
| Compliance | ISO 4406:2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Sensor Generations | 7th-generation dual-laser narrow-beam optical sensors |
| Software | P6.4 Integrated Particle Analysis Suite (PC & embedded versions) |
| Control Interface | Industrial-grade touchscreen HMI + optional IPC integration |
| Measurement Range | 0.03 μm to 3000 μm (configurable sensor modules A–N) |
| Channel Count | Up to 1000 user-configurable size channels (any 16 active per test) |
| Sensitivity | 1 μm (per ISO 4402) or 4 μm(c) (per ISO 11171 / GB/T 18854) |
| Accuracy | < ±3% |
| Volume Precision | ±1% |
| Sample Volume | 1–200 mL (programmable) |
| Flow Rate | Sampling 5–60 mL/min |
| Max Online Pressure | 0–0.6 MPa (standard) |
| Viscosity Range | Offline ≤99 mm²/s |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Resolution | ≥90% at 60 mL/min |
| Reporting | Real-time particle count per size bin, distribution histogram, cumulative curve, ISO/NAS/GJB contamination code, pass/fail flagging |
| Data Output | RS232, RS485, USB, analog 4–20 mA / 0–5 V, MODBUS RTU |
| Alarm Logic | Configurable threshold-based超标 alert (hardware + software) |
| Storage Capacity | Up to 6,000 test records (200 × 30-result sets) |
| Auto-Cleaning | Integrated post-test fluidic purge cycle |
| Operating Temp. | Sample 20–65 °C |
| Power | 220 VAC, 50 Hz, <80 W |
| Metrological Accreditation | CALIBRATED BY National Northwest Metrology & Testing Center (civil) / CASC First-Level Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Measurement Principle | Light Blockage (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Particle Size Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Volumetric Accuracy | ±1% |
| Flow Rate (Sampling) | 5–60 mL/min |
| Flow Rate (Cleaning) | 5–150 mL/min |
| Max. Online Pressure | 0–31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Ambient to 65°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203 (8-Channel) |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam sensor |
| Measurement Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliant with | ISO 4406:1987/1999, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Particle Size Range | 0.03 µm to 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-definable size channels (16 active per test) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Volume Accuracy | ±1% |
| Sample Flow Rate | 5–60 mL/min (test), 5–150 mL/min (cleaning) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Operating Pressure (Online) | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure regulator) |
| Sample Volume | 1–200 mL (programmable) |
| Temperature Range | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Auto-Cleaning Function | Yes |
| Software | P6.4 Analysis & Testing Suite (Integrated & PC Edition) |
| Compliance Support | FDA 21 CFR Part 11 audit trail (optional configuration), GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Sample Volume Accuracy | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Operating Pressure | 0–0.6 MPa (standard) |
| Temperature Range | Sample: 20–65°C |
| Ambient | 0–50°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA analog, MODBUS RTU |
| Alarm Output | Configurable particle count or size-based threshold alert |
| Internal Storage | Up to 6000 test records (200 tests × 30 results each) |
| Software | P6.4 Particle Analysis Suite (PC & embedded integrated version) |
| Display | Color LCD touchscreen interface |
| Self-cleaning Function | Integrated post-test rinse cycle |
| Regulatory Traceability | Certified by National Northwest Metrology & Testing Center (civilian) and PLA Commission of Science, Technology and Industry for National Defense — First-Level Particle Metrology Station (military) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PLD-0203 Series |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Laser Sensor | 7th-generation dual-laser narrow-beam detector |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 channels (user-selectable 16 size bins) |
| Sensitivity | 1 µm (ISO 4402) or 4 µm(c) (ISO 11171 / GB/T 18854) |
| Resolution | ≥90% @ 60 mL/min |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Sample Volume Accuracy | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Pressure Rating | 0–0.6 MPa (standard) |
| Standards Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500, GB/T 18854, JJG 1061, MTD/ISO 11171, ACFTD/ISO 4402, ASTM F658-87 (PSL calibration) |
| Software | P6.4 Integrated Analysis & Testing Software (PC & embedded versions) |
| Control Interface | Industrial-grade touchscreen LCD (integrated IPC or external industrial PC) |
| Data Output | Real-time particle count per channel, size distribution histogram, cumulative curve, contamination grade classification (NAS/ISO), built-in thermal printer, RS232/RS485/USB, MODBUS, 4–20 mA & 0–5 V analog outputs |
| Storage Capacity | Up to 6,000 test records (200 tests × 30 results each) |
| Self-Cleaning Function | Yes |
| Operating Temperature | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Calibration Traceability | Certified by National Northwest Metrology & Testing Center (civil) or CASC First-Level Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0203-16 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Software | P6.4 Integrated Analysis & PC Edition |
| Control System | Embedded Industrial PC or External Industrial PC |
| Compliance Standards | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, ISO 11500, DL/T 432, GJB 380 |
| Calibration Standards | JJG 1061, ISO 11171, ISO 4402 (ACFTD), GB/T 18854, ASTM F658-87 (PSL Latex Spheres) |
| Measurement Range | 0.03 µm – 3000 µm (model-dependent configuration) |
| Sensitivity | 1 µm (ISO 4402) or 4 µm(c) (ISO 11171 / GB/T 18854) |
| Channel Count | 1000 user-configurable size channels |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Accuracy | <±3% |
| Sample Volume | 1–200 mL (programmable) |
| Volume Precision | ±1% |
| Online Pressure Range | 0–0.6 MPa (standard) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Temperature Range | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, ±1%, <80 W |
| Data Output | Particle count vs. size distribution, histogram, cumulative curve, contamination grade (NAS/ISO), built-in thermal printer |
| Communication Interfaces | RS232, RS485, USB (U-disk), MODBUS, 4–20 mA analog output, 0–5 V analog output |
| Alarm Function | Configurable threshold-based particle count alarm |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Auto-Cleaning | Yes, post-analysis rinse cycle |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail (software-enabled), GLP/GMP-ready data integrity framework |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-0203-16 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor (7th Generation) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance Standards | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-selectable size channels |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Accuracy | < ±3% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Sample Volume Precision | ±1% |
| Flow Rate | Sampling 5–60 mL/min |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Pressure | 0–0.6 MPa (standard) |
| Sample Temperature | Ambient to 65 °C |
| Ambient Temperature | 0–50 °C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, MODBUS, 4–20 mA / 0–5 V analog |
| Data Storage | Up to 6000 test records (200 tests × 30 results/test) |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail (optional configuration), GLP/GMP-ready reporting structure |
| Cleaning Protocol | Automated post-test rinse cycle |
| Certification | Calibrated per national military standard by CALIBRATION AUTHORITY OF THE COMMISSION OF SCIENCE, TECHNOLOGY AND INDUSTRY FOR NATIONAL DEFENSE (CSTIND) — Grade I Particle Metrology Station (Military Grade), or NORTHWEST NATIONAL METROLOGY & TESTING CENTER (Civil Grade) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Principle | Light Obscuration (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Channel Count | 1000 configurable size channels (16 user-selectable bins) |
| Size Range | 0.03 µm – 3000 µm (model-dependent configuration) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Resolution | ≥90% at 60 mL/min |
| Accuracy | < ±3% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Sample Volume | 1–200 mL (programmable) |
| Volume Precision | ±1% |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Pressure Rating | 0–0.6 MPa (standard) |
| Operating Temp. | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Output | Real-time particle count vs. size histogram, cumulative/differential distribution, contamination grade (NAS/ISO), RS232/RS485/USB, 4–20 mA & 0–5 V analog outputs, MODBUS RTU, built-in thermal printer |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Cloud Integration | PULUODY Oil Monitoring Cloud Platform |
| Self-Cleaning Function | Yes |
| Onboard Storage | Up to 6000 test records (200 assays) |
| Regulatory Support | Audit trail, user access control, electronic signature-ready for GLP/GMP environments per FDA 21 CFR Part 11 guidance |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, MTD/ISO 11171, JJG 1061 |
| Compliance Standards | ISO 4406:1987/1999, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Measurement Range | 0.03 µm to 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 user-selectable size channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% at 60 mL/min |
| Volumetric Accuracy | ±1% |
| Sample Volume | 1–200 mL (programmable) |
| Flow Rate | 5–60 mL/min (test), 5–150 mL/min (cleaning) |
| Max. Online Pressure | 0.6 MPa (standard), 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Sample inlet 20–65°C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Data Output | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Storage Capacity | Up to 6000 test records (200 tests × 30 results each) |
| Self-cleaning Function | Yes |
| Software | P6.4 Analysis & Testing Software (Integrated & PC Edition) |
| Control Interface | Industrial-grade color touchscreen LCD |
| Regulatory Certification | Calibrated per national military metrology standards (CNSA Defense Science & Technology Commission Level-1 Particle Metrology Station) |
| Brand | PULUODY |
|---|---|
| Model | PLD-1884B |
| Temperature Control Range | 5–80 °C |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W |
| Input Power | <1000 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Construction | Stainless Steel Bath with Optical Clarity |
| Cooling System | Imported Hermetic Compressor |
| Circulation | Magnetic Drive Circulating Pump |
| Compliance | GB/T 1884, ASTM D1298, ISO 3675 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PLD-1885A |
| Instrument Type | True Density Calculator |
| Form Factor | Portable |
| Sample Type | Liquid |
| Density Measurement Range | 0.0005 g/mL |
| Density Accuracy | ±0.0005 g/mL |
| Compliance Standard | GB/T 1885–1998 “Petroleum Measurement Tables” |
| Application Scope | Crude oil, gasoline, diesel, lubricating oils, water content (mₛ) and net oil mass (m꜀) calculation |
| Temperature Range | –55 °C to +50 °C |
| Power Supply | Rechargeable battery or 220 V AC adapter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | PLD-201 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 0.01 µm – 1000 µm (sensor-dependent, up to 1000 channels) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Sample Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Calibration Standards | ISO 11171, ISO 4402, ISO 4406, NAS 1638, GB/T 14039, GJB 420A/B, DL/T 432, JJG/T 066 |
| Compliance | Meets GLP-relevant data integrity requirements |
| Software | PULL 8.1 Multi-Language Analysis Platform (English, Chinese, Japanese, Korean, etc.), 3000-test onboard storage, RS232 interface, touchscreen GUI with dual input (touch + keypad), integrated thermal printer |
| Operating Temperature | 0–50 °C |
| Sample Viscosity Limit | ≤450 mm²/s |
| Pressure Range | −0.08 to 0.8 MPa |
| Sampling Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (test), 10–100 mL/min (cleaning) |
| Repeatability | ≤5% coincidence error at 10,000 particles/mL |
| Data Output | Particle count per mL, contamination grade (ISO/NAS), histogram, cumulative distribution, raw pulse data |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PLD-601 |
| Price Range | USD 55,000–69,000 (FOB UK) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.1–800 µm |
| Repeatability | ≥99% |
| Measurement Time | 10–60 s |
| Brand | PULUODY |
|---|---|
| Model | PLD-601 |
| Instrument Type | Optical Particle Counter (Light Obscuration Method) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Channel Count | 1000 Adjustable Channels (Down to 0.01 µm resolution) |
| Particle Size Range | 1–450 µm (Extended Range: 0.03–3000 µm Optional) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Sampling Accuracy | < ±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (Calibrated per ChP 2015/2020), <10% (Calibrated per USP/ISO 21501) |
| Software | V8.9 Integrated PC & Touchscreen Analysis Suite |
| Compliance | FDA 21 CFR Part 11, Annex 11, GLP/GMP Data Integrity Requirements, Audit Trail, Electronic Signature, Five-Tier User Permissions |
| Standards Supported | ChP 0903 (2015 & 2020), USP <788>, <789>, <797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21501-4, ISO 11171, ISO 4406, NAS 1638, SAE AS4059, MIL-STD-1246, ASTM D6786, GB/T 18854, DL/T 432, GJB/T 420A/B |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration (LO) Particle Counter |
| Measurement Range | 1–500 µm |
| Repeatability | 1000 particles/mL (2.5% coincidence error) |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-601 |
| Price | USD 35,200 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm available upon configuration) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | ≤60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601-1 |
| Instrument Type | Optical Particle Counter |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Software Version | V8.9 Integrated PC-Based Analysis Software |
| Compliance Standards | Chinese Pharmacopoeia 2015 & 2020, USP <788> & <789>, EP 2.9.19, BP, GB 8368 |
| Calibration Traceability | JJG 1061, ISO 21501-4, NIST-Traceable Latex Standards |
| Detection Range | 1–450 µm (extended range 0.03–3000 µm optional) |
| Custom Channel Configurations | 4, 6, 8, 16, 32, 64, or 128 user-defined size bins |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Sampling Accuracy | < ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501-4) |
| Display Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-601-N |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Channel Resolution | 1000 Channels |
| Minimum Detectable Size | 0.01 µm |
| Calibration Standards | ISO 21501-4, JJG 1061, USP <788>, ChP 2020 <0903>, EP 10.0, ISO 11171 |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signature, 5-Tier User Permissions |
| Operating Temperature Range | 0–80 °C (fluid), 0–50 °C (ambient) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±5% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (5% coincidence error) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501) |
| Customizable Size Ranges | 1–100 µm, 4–70 µm(c), 0.1 µm(c), or user-defined thresholds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PLD-601-X |
| Price | USD 26,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 5–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-601-Y |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm (extendable to 0.03–3000 µm with optional configuration) |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Sampling Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm resolution) |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Resolution Compliance | >95% (ChP), <10% (USP/ISO 21501) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Software | V8.9 Integrated Analysis Suite (PC & touchscreen), 5-level user permission, audit trail, electronic signature, 21 CFR Part 11 compliance |
| Regulatory Alignment | ChP 2015/2020 <0903>, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, ISO 11171, NAS 1638, MIL-STD-1246C |
