| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406:1999, NAS 1638, GJB 420B, GJB 380, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95 |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Sampling Volume | 1 mL to unlimited (programmable) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment system) |
| Max. Fluid Viscosity | ≤350 cSt |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Data Output | Onboard thermal printer, RS232 interface, histogram & distribution curve generation |
| Calibration Traceability | Certified by CALIBRATION STATION NO. 116, National Defense Science & Technology Industry Particle Metrology Level-1 Station (Aviation Industry Particle Metrology Center) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CCACS1.0 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm (c), customizable bins (e.g., 4–128 bins) |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | Offline 0–99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Sampling Precision | <±1% |
| Output Interfaces | RS232, RS485, USB, LAN, 4–20 mA analog, MODBUS protocol |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, GBW reference materials |
| Compliance | GB/T 11446.9, GJB 420B-2006, HB 6639/6649, QJ 2850/3024, MIL-STD-1246C, SAE AS4059F, NAVAIR 01-1A-17, ROCT 17216-2001 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | CCACS1.0-01 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | 0–99 mm²/s (offline), up to 500 mm²/s (pressurized) |
| Temperature Range | Fluid 0–80°C, Ambient −15–50°C |
| Calibration Standards | JJG 1061, ISO 21501-4, GB/T 11446.9, GJB 420B-2006, SAE AS4059F, MIL-STD-1246C, HB 6639/HB 6649, NAVAIR 01-1A-17 |
| Compliance | GLP/GMP-ready data integrity, 21 CFR Part 11-compatible audit trail (via optional software module) |
| Interface | RS232/RS485, USB, LAN, 4–20 mA analog output, MODBUS protocol |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Instrument Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquids |
| Density Range | 0.001–1.999 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Temperature Range | 0–50 °C |
| Repeatability | ±0.01 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | 10 mL |
| Compliance Standards | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1511 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Laser Diffraction & Dynamic Light Scattering (DLS) / Flow Imaging |
| Test Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Detection System | 7th-Generation Dual-Laser Narrow-Beam Sensor |
| Compliance | ISO 13320, ISO 13321, SY/T 5329-2012, SY/T 6596-2016 |
| Repeatability | ≤ ±1% for D50 (certified reference materials) |
| Sample Throughput | ≤ 2 min per sample |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 10–30 °C, RH < 85%, vibration-free, EMI-shielded, grounded power |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1511 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–500 µm |
| Repeatability | <1% |
| Measurement Time | 60 sec |
| Detection Principle | Optical Diffraction & Scattering / Laser Flow Imaging |
| Compliance | ISO 13320, ISO 13321 |
| Sample Throughput | One sample per ≤2 min |
| Software Interface | Bilingual (English/Chinese), Windows-compatible |
| Reporting | D3, D10, D25, D50, D75, D80, D90, D97, D100, Span, Specific Surface Area, Aspect Ratio, Circularity Distribution |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513 |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Laser Diffraction & Flow Imaging Hybrid Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | <5% (D50) |
| Measurement Time | ≤30 s per sample |
| Detection Principle | Laser Diffraction (ISO 13320 compliant) + Hydrodynamic Focusing Flow Imaging (ISO 13321 compatible) |
| Sample Introduction | Static cuvette & recirculating wet dispersion unit |
| Software Platform | Windows-native, bilingual (EN/CN), 20 report templates |
| Compliance | SY/T 5329–2012, Q/SY 01004–2016, SY/T 6596–2016, SY/T 5523–2016 |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1513-1 |
| Measurement Principle | Optical Diffraction & Scattering (ISO 13320) / Laser Flow Imaging (ISO 13321) |
| Dynamic Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Repeatability | ≤ ±1% RSD for D50 (certified reference materials) |
| Sample Throughput | ≤2 min per analysis |
| Compliance | SY/T 5329–2022, SY/T 5523–2016, Q/SY 01004–2016, ISO 13320, ISO 13321 |
| Detector | 7th-generation dual-laser narrow-beam photodetector |
| Software | Windows-compatible bilingual (EN/CN), 20 report templates, automated workflow (alignment, background, concentration adjustment, acquisition, analysis, cleaning) |
| Power | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 0–40 °C, clean lab environment |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1513-a |
| Price | USD 39,200 (approx.) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 1% |
| Measurement Time | 30–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513-b |
| Origin | Shaanxi, China |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 5% |
| Measurement Time | 30–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/3.0/5.0/10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, ≥98% at ≥0.5 µm (per ISO 21501-4) |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Data Storage | 10,000 measurement records |
| Battery | 4100 mAh Rechargeable Polymer Li-ion |
| Display | 3.45″ Full-View Industrial Color LCD |
| Operating Temperature | 5–45 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, ISO 21501-4:2018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, and 10.0 µm (configurable channel sets A–D) |
| Counting Efficiency | ≥50% at 0.3 µm |
| Coincidence Error | <5% at 2,000,000 particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Mode | Timed (60 s default) or cyclic |
| Data Storage | 10,000 measurement records |
| Display | 3.45″ industrial-grade full-view color LCD |
| Power | Rechargeable 4100 mAh polymer lithium battery |
| Operating Temp. | 5–45 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, EU GMP Annex 1 (2022), USP <788> |
| Optional Sensors | Temperature & relative humidity (–40 to 120 °C / 0–100% RH), CO, HCHO |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Sensor Technology | 7th-Generation Dual-Laser Narrow-Beam Detection |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/5.0/10.0 µm |
| Counting Accuracy | <5% coincidence error at 2,000,000 particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | Programmable (default 60 s) |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Battery | Rechargeable 4100 mAh polymer lithium-ion |
| Data Storage | Up to 10,000 measurement records |
| Display | 3.45-inch industrial-grade full-view color LCD |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, GMP Annex 1 (2022), USP <788> (particle counting in compressed gases) |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Instrument Type | Optical Airborne Particle Counter |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, or 100 L/min |
| Sampling Time | 60 s default |
| Display | 10.0-inch industrial TFT-LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11-ready |
| Environmental Monitoring Modes | Particle count (#/L), Mass concentration (µg/m³), Filtration efficiency (%) |
| Integrated Sensors | Ambient temperature (−40–120 °C), Relative humidity (0–100% RH), Optional gas sensors (CO, HCHO, etc.) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Protection Features | Overvoltage, overcharge, short-circuit, ESD, and EMI shielding |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Instrument Type | Optical Airborne Particle Counter |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, or 100 L/min |
| Sampling Time | 60 s default |
| Environmental Sensors | Integrated temperature (−40 to +120 °C), relative humidity (0–100% RH), dew point |
| Gas Detection Capability | Up to 3 optional electrochemical or NDIR gas sensors (e.g., CO, HCHO) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11 (audit trail, electronic signatures, role-based access) |
| Display | 10.0-inch industrial-grade TFT LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB/SD) |
| Output Interfaces | RS232, RS485, LAN, USB |
| Alarm Modes | Configurable particle count/mass thresholds |
| Power | AC 100–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Safety Protections | Overvoltage, overcharge, short-circuit, ESD-hardened, EMI-shielded enclosure |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2623, DPC-2611, DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, 100 L/min |
| Particle Size Channels | Configurable from 0.10 µm to 25.0 µm (6-channel selectable calibration sets) |
| Counting Accuracy | ≤ ±30% for particle size distribution |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE |
| Data Storage | ≥10,000 test records with timestamp, location tag, and operator ID |
| Communication | RS232, RS485, LAN, USB |
| Regulatory Features | Audit trail, user access control, electronic signatures per 21 CFR Part 11 |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | PULUODY |
|---|---|
| Model | DPC-2623 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Laser Light Scattering (Narrow-Beam Dual-Laser Sensor) |
| Particle Size Range | 0.1 µm to 25.0 µm (configurable channels across 6 channel sets) |
| Channel Count | 20 adjustable size bins |
| Size Resolution Error | ≤ ±30% |
| Concentration Accuracy | ≤ ±30% |
| Repeatability | ≤ ±10% FS |
| Coincidence Loss | <5% at 2×10⁶ particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | 60 s default |
| Operating Temperature | 5–45 °C |
| Storage Temperature | –40–120 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| IP Rating | IP66 |
| Explosion Protection | Exd II CT4 (intrinsic safety) |
| Compliance | ISO 14644-1, ISO 21501-4, JJF 1190, GMP Annex 1 (2022), USP <788>, FDA 21 CFR Part 11 (software audit trail capable) |
| Data Storage | Local 10,001 records + remote cloud/archive via USB/RS232 |
| Display | 3.45″ industrial TFT LCD |
| Power | 4100 mAh polymer rechargeable battery (optional) |
| Multi-parameter Capability | Integrated temperature/humidity/dew point |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2623 |
| Instrument Type | Optical Particle Counter |
| Laser Sensor | Dual-beam narrow-laser detection (7th-generation) |
| Particle Size Channels | 20 configurable channels (0.10–25.0 µm) |
| Size Resolution Options | Configurable sets A–F per ISO 21501-4 |
| Counting Accuracy | ≤±30% (per ISO 21501-4 & JJF 1190) |
| Repeatability | ≤±10% FS |
| Coincidence Loss | <5% at 2×10⁶ particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | Adjustable (default 60 s) |
| Detection Modes | Particle number (particles/L), mass concentration (µg/m³), filtration efficiency (%) |
| Environmental Sensors | Integrated temperature/humidity (–40–120 °C, 0–100% RH), optional differential pressure & toxic gas (CO, HCHO) modules |
| Display | 3.45″ industrial-grade full-view color LCD |
| Data Storage | Onboard 10,000+ records + remote cloud/archive via USB/RS232 |
| Power | 4100 mAh polymer rechargeable battery (optional) |
| Protection | IP66, ExdII CT4 (intrinsically safe) |
| Compliance | ISO 14644-1:2015, ISO 21501-4:2018, GMP Annex 1 (2022), USP <788>, FDA 21 CFR Part 11 (audit trail ready), JJF 1190–2019 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OMS-IIA |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406, NAS 1638, ISO 11171, GB/T 18854, USP <788>, EP 2.9.19, ASTM F658, MIL-STD-1246, GJB 420B |
| Measurement Range | 0.03–3000 µm (configurable) |
| Sensitivity | 1 µm (ISO 4402), 4 µm(c) (ISO 11171 / GB/T 18854) |
| Channel Count | Up to 1000 user-definable size channels |
| Accuracy | <3% |
| Repeatability | ≤5% CV |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Resolution | ≥90% @ 60 mL/min |
| Sample Volume | 1–200 mL (programmable) |
| Viscosity Range | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Operating Pressure (Online) | 0–0.6 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Temperature Range | Sample: 20–65 °C |
| Ambient | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Output Interfaces | RS232, RS485, MODBUS, 4–20 mA, 0–5 V analog |
| Data Storage | Up to 6000 test records (200 tests) |
| Software Platform | P6.4 Particle Analysis Suite (Integrated & PC Edition) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OMS-IIA-16 |
| Instrument Type | Optical Light-Blockage Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Measurement Range | 0.03–3000 µm (configurable) |
| Sensitivity | 1 µm (per ISO 4402) / 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Count | Up to 1000 user-definable size channels |
| Accuracy | <3% |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Sample Viscosity | Offline: 0–99 mm²/s |
| Online | 0–500 mm²/s |
| Flow Rate | Sampling: 5–60 mL/min |
| Cleaning | 5–150 mL/min |
| Operating Pressure (Online) | 0–0.6 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Temperature Range | Sample: RT–65°C |
| Ambient | 0–50°C |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GB/T 18854, ISO 11171, USP <788>, EP 8.0, JP 16, ChP 2015, ISO 16889, GB/T 30176 |
| Data Output | RS232, RS485, MODBUS, 4–20 mA, 0–5 V analog |
| Software | P6.4 Integrated Analysis Platform (PC & embedded versions) |
| Calibration Traceability | NIM-accredited reference materials (GBW), MTD/ISO 11171, ACFTD/ISO 4402, PSL latex spheres per ASTM F658-87 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | OMS-IIA01 |
| Instrument Type | Optical Liquid Particle Counter (Light Obscuration Principle) |
| Measurement Range | 0.03–3000 µm (configurable) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Channel Count | Up to 1000 user-definable size channels |
| Accuracy | <3% |
| Coincidence Limit | 10,000 particles/mL (≤5% coincidence error) |
| Resolution | ≥90% at 60 mL/min |
| Sample Viscosity | Offline ≤99 mm²/s |
| Operating Pressure (Online) | 0–0.6 MPa (standard), up to 31.5 MPa (with pressure regulator) |
| Flow Rate | Sampling 5–60 mL/min |
| Temperature Range | Sample 20–65°C |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GB/T 18854, ISO 11171, USP <788>, EP 8.0, JP 16, ChP 2015, ISO 16889, GB/T 30176 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC Particle Detector |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering (7th Generation) |
| Measurement Range | 1–150 µm |
| Channel Count | 8 |
| Calibration Standards Supported | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GJB 420B, GOST 17216, GB/T 14039, DL/T 432, JB/T 9737, GB/T 18854 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, optional 4–20 mA / 0–5 V analog |
| Power Supply | 9–30 VDC |
| Reporting | particles/mL + ISO/NAS/GJB contamination code |
| Enclosure Rating | IP65 (industrial-grade robust housing) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 1–150 µm |
| Repeatability | 1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 1–150 µm |
| Channels | 8 |
| Calibration Standards | ISO 11171, ISO 4406, NAS 1638, GJB 420B, GOST 17216, GB/T 14039, SAE AS4059, IP 564/565 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Range | 0–500 cSt |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + Contamination Code (e.g., ISO 4406:2017) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | OPC-0203 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Range | 2–750 µm (configurable up to 1000 µm) |
| Size Channels | Up to 1000 user-defined bins (e.g., 8/16/32 standard channels) |
| Resolution | 0.1 µm |
| Accuracy | < ±3% typical |
| Counting Precision (Coincidence Error) | ≤5% at 999,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Flow Rate | 6–500 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure-reducing valve) |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Data Storage | Unlimited local logging |
| Alarm Functions | Particle count threshold, sensor health diagnostics |
| Power Supply | 9–30 VDC or 220 VAC |
| Compliance Basis | Configurable to ISO 11171, ISO 4406, NAS 1638, ASTM D6786, USP <788>, and customer-specified LO calibration protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC-0203A |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Eighth-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Range | 2–750 µm (configurable up to 1000 µm) |
| Size Channels | Up to 1000 user-defined bins (e.g., 8/16/32 standard channels) |
| Resolution | 0.1 µm |
| Counting Accuracy | < ±3% typical |
| Coincidence Error | ≤5% at 999,999 particles/mL |
| Maximum Concentration | 9,999,999 particles/mL |
| Sampling Flow Rate | 6–500 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure-reducing valve) |
| Fluid Temperature Range | −10 °C to +80 °C |
| Output Interfaces | 4–20 mA analog, RS232/RS485 digital |
| Data Storage | Unlimited local logging |
| Calibration Standards | NIST-traceable latex spheres, AC fine test dust, MTD |
| Compliance Options | Customizable to ISO 4406, NAS 1638, SAE AS4059, ASTM D7647, USP <788> & <789>, and client-specific water quality protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering (7th Generation) |
| Measurement Range | 1–150 µm |
| Channel Count | 8 |
| Standards Compliance | NAS 1638 (00–>12), ISO 4406 (00–>28), GJB 420B (00–>12), GOST 17216 (00–>17), GB/T 14039, ISO 11171, SAE AS4059, MIL-STD-1246, IP 564/565, JIS B 9933, DL/T 432 & 1096, JB/T 9737, GB/T 18854 |
| Pressure Rating | 0–1.0 MPa (direct), 0–31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, optional 4–20 mA / 0–5 V analog |
| Power Supply | 9–30 VDC |
| Enclosure Rating | IP65-rated rugged housing |
| Calibration Support | Traceable to ISO 21501-4 and ISO 11171 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | OPC-16 Channel |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering (7th Generation) |
| Measurement Range | 1–150 µm |
| Number of Channels | 16 |
| Calibration Standards Supported | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GJB 420B, GOST 17216, GB/T 14039, DL/T 432, JB/T 9737, GB/T 18854 |
| Pressure Rating | 0–1.0 MPa (standard), up to 31.5 MPa (with integrated pressure reducer) |
| Flow Rate | 15–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | RS232, RS485, 4–20 mA, 0–5 V (customizable) |
| Power Supply | 9–30 VDC |
| Reporting | Particles per mL + ISO/NAS/GJB contamination code |
| Compliance | Supports GLP/GMP audit trails, ASTM D6786, ISO 11500, IP 564/565 |
| Brand | PULUODY |
|---|---|
| Model | OPC-1800 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm |
| Channel Count | 1000 adjustable size channels |
| Calibration Standards | JJG 1061, ISO 11171, USP <788>, USP <789>, EP 2.9.19, JP 6.06, GB/T 11446.9-2013, ISO 21510, NAS1638, ISO 4406 |
| Sampling Accuracy | <±1% |
| Precision | <±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution | <10% (per latex sphere calibration per JJG 1061) |
| Sample Flow Rate | 5–60 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Operating Environment | −15–50 °C |
| Interface | RS232, RS485-to-USB, USB, MODBUS RTU |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Software | P6.4 Integrated & PC Edition |
| Control | Industrial PC or Embedded IPC |
| Detection Principle | Seventh-generation dual-laser narrow-beam light obscuration |
| Sensor | High-stability optical sensing module with temperature-compensated photodetector array |
| Compliance Support | Fully configurable to USP, EP, JP, BP, IP, WHO, ChP, ISO, ASTM, and military standards (e.g., MIL-STD-1246, GJB/T 420A/B) |
| Brand | PULUODY |
|---|---|
| Model | OPC-1800A |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm |
| Channel Count | 1000 adjustable size channels |
| Resolution | <10% (per JJG 1061 or NIST-traceable latex standard calibration) |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Sampling Precision | <±1% |
| Flow Rate (Sampling) | 5–60 mL/min |
| Flow Rate (Cleaning) | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Operating Ambient Temperature | −15–50 °C |
| Viscosity Range | 0–99 mm²/s (offline), up to 500 mm²/s (pressurized) |
| Interface | RS232, RS485-to-USB, USB, MODBUS RTU, 4–20 mA analog output |
| Display | Color LCD touchscreen |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Laser Sensor | 7th-generation dual-laser narrow-beam obscuration detector |
| Software | P6.4 Particle Analysis Suite (Integrated & PC versions) |
| Calibration Standards | GBW certified reference materials |