Physical Property Testing Instruments
Filter
Showing 8911–8940 of 12372 results
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HBS |
| Lamp Configuration | 3 x air-cooled xenon arc lamps |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 85 °C |
| Relative Humidity Control | 10–95% RH |
| Water Requirements | Deionized or purified water for spray and humidity systems |
| Spray Options | Front spray (top-mounted dual nozzles), optional rear spray (dual-sided wetting), optional secondary liquid spray (e.g., acid rain simulation) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 × 51 mm × 102 mm specimens |
| Calibration | Patented AUTOCAL system |
| Compliance Support | ASTM G155, ISO 4892-2, SAE J2527, J2412, AATCC TM16, ISO 11341, GB/T 16422.2, FDA 21 CFR Part 11 (via optional software audit trail) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-3-HC |
| Xenon Lamp Power | 1800 W (3 lamps) |
| Temperature Range | Ambient to 90°C (operational, with refrigeration option) |
| Humidity Range | 20–95% RH |
| Sample Capacity | 55 specimens |
| Sample Tray Dimensions | 45 × 72 cm |
| Sample Tilt Angle | 10° from horizontal |
| Black Panel Temperature Range | 35–110°C (adjustable per sensor) |
| Black Standard Temperature Range | 36–120°C |
| Water Consumption | 0.1 L/min (spray), 44 L/day (humidification) |
| External Dimensions | 78 × 94 × 94 cm |
| Refrigeration Unit Weight | 85 kg |
| Lamp Life Warranty | 1500 hours |
| Compliance | ASTM D2565, D4459, D6695, D7356, ISO 4892-2, ISO 11341, SAE J2527, J2412, GB/T 16422.2, and others |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HDS |
| Lamp Type | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV 300–400 nm) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 90 °C (with optional refrigerated cooling unit) |
| Relative Humidity Control | 10–95% RH (standard) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Sample Capacity | Up to 51 specimens (51 mm × 102 mm) |
| Dual Spray System | Standard (deionized water + secondary solution, e.g., acid rain or detergent) |
| Calibration | AUTOCAL® automated calibration system |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Interface | Touchscreen controller with built-in Ethernet, self-diagnostic alerts, GLP/GMP-ready audit trail logging |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HS |
| Cooling Type | Air-Cooled |
| Lamp Power | 1800 W |
| Spectral Range | Full-Spectrum Solar Simulation (UV, Visible, IR) |
| Humidity Control | Standard RH Regulation (10–95% RH) |
| Water Spray Function | Dual Nozzle Top-Mounted Spray System |
| Sample Tray Dimensions | 45 × 72 cm |
| Max Sample Capacity | 55 specimens (51 × 102 mm each) |
| Black Panel Temperature Range | 35–110 °C |
| Chamber Air Temperature Range | 25–80 °C |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HS |
| Light Source | High-Stability Xenon Arc Lamp |
| Spectral Range | 290–800 nm (full-spectrum solar simulation) |
| Black Standard Temperature Control | 35–110°C |
| Relative Humidity Range | 10–95% RH |
| Water Spray Function | Programmable intermittent rain simulation |
| Lamp Life | ≥1500 hours |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, and other international weathering standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HSC |
| Humidity Control | Standard RH control (20–95% RH, ±2% RH accuracy) |
| Temperature Range | 31–120°C (black panel), ambient air temperature independently monitored and controlled |
| Irradiance Control | SOLAR EYE broadband feedback system at 340 nm, 420 nm, or TUV |
| Lamp Configuration | 3 × air-cooled xenon arc lamps (1500 h rated life) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Max Sample Capacity | 51 × 51 mm × 102 mm specimens |
| Optional Features | Water spray (dual-nozzle, purified water only), refrigerated cooling unit (enables sub-ambient black panel temperatures), dual-fluid spray (e.g., acid rain simulation) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Density measurement range | 0–1.999 g/cm³ |
|---|---|
| Density accuracy | ±0.001 g/cm³ |
| Alcohol concentration range | 0–100% (v/v) |
| Alcohol accuracy | ±0.5% (v/v) |
| Temperature control | 20 °C ±0.1 °C |
| Sample volume per measurement | 2 mL |
| Data storage capacity | 80 entries |
| Power supply | 220 V ±22 V, 50 Hz ±1 Hz, 50 VA |
| Operating ambient temperature | 5–35 °C |
| Net weight | 2 kg |
| Brand | QATCH |
|---|---|
| Origin | USA |
| Model | NanovisQ |
| Instrument Type | Oscillatory Viscometer (Fixed-Form Factor) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.1–1,000,000 cP |
| Sample Volume | 3–5 µL |
| Measurement Time | ≤5 min |
| Shear Rate Range | 10¹–10⁶ s⁻¹ (5 decades) |
| Sensor Type | Disposable Quartz-Based Acoustic Microfluidic Chip |
| Detection Principle | Non-contact Optical + Piezoelectric Resonance Monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 CHD MASTER/Plus |
| Instrument Type | Microhardness Tester |
| Control System | Electromechanical closed-loop sensor actuation |
| Turret | 6-position motorized turret |
| Operating Concept | 3D intuitive human-machine interface |
| Test Automation | Fully programmable sequence-based testing with adaptive dwell-time termination |
| Data Output | Configurable report templates with embedded hardness conversion algorithms |
| Image Quality | High-resolution optical imaging system with LED illumination and digital autofocus capability |
| Testing Space | Large X-Y-Z travel range (X: 200 mm, Y: 200 mm, Z: 150 mm) |
| Connectivity | Ethernet, USB 3.0, RS-232, optional integration with LIMS and MES systems |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 A/A+ |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 187 mm / 180 mm (extendable to 377 mm) |
| Maximum Specimen Weight | 50 kg |
| Motorized Cross-Table Dimensions | 170 × 250 mm |
| Height Adjustment Speed | up to 6 mm/s |
| Power Supply | 230 V~1/N/PE or 110 V~1/N/PE |
| Max. Power Consumption | ~240 W |
| Host Weight | 120 kg (137 kg with height extension) |
| Interface | 3× USB |
| Software | Qpix Control2 |
| Optional Features | Dual high-resolution camera system (up to 2×), panoramic camera (A+ only), motorized anvil/cross-table, Jominy fixture, multi-specimen holders, interchangeable indenters and objectives |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 CS ECO |
| Instrument Type | Rockwell Hardness Tester |
| Force Range | 1–250 kg (9.81–2452 N) |
| Test Height | 250 mm |
| Throat Depth | 157 mm |
| Maximum Specimen Weight | 100 kg |
| Machine Weight | 77 kg |
| Display | 7-inch capacitive color touchscreen |
| Force Application | Electromechanical, fully automated |
| Power Supply | 100–240 V AC, 45–65 Hz, ~60 W |
| Compliance | ASTM E18, ISO 6508, DIN 50103, GB/T 230.2 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 R |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 260 mm / 180 mm |
| Extended Test Height (Optional) | 450 mm |
| Vertical Adjustment Speed | up to 6 mm/s |
| Anvil/Cross Table Dimensions | 250 × 260 mm |
| Data Interfaces | 3× USB, 1× Ethernet, 1× RS232 |
| Unit Weight | 95 kg (112 kg with height extension) |
| Max. Specimen Weight | 100 kg |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~240 W |
| Software | Qpix T2R |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 RCS |
| Hardness Test Method | Rockwell C Scale (HRC) |
| Maximum Test Force | 150 kgf (1471.5 N) |
| Dual Force Range Capability | 62.5 kgf (613.1 N) and 150 kgf (1471.5 N) |
| Test Height Adjustment Range | 180 mm |
| Horizontal Test Space | 180 mm |
| Anvil Diameter | Ø100 mm |
| Machine Weight | 120 kg |
| Interface | 1 × RS232-C, 1 × RJ45 (Ethernet) |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~360 W |
| Control System | Siemens S7 PLC with 4" Touchscreen HMI |
| Cycle Time | <3 s per test |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 200 CS |
| Instrument Type | Brinell-Vickers-Rockwell Combined Hardness Tester |
| Test Force Range | 0.5 – 187.5 kgf (4.9 – 1839 N) |
| Test Space | 250 mm (height) × 238 mm (throat depth) |
| Turret Positions | 5 |
| Imaging System | 5 MP industrial camera with Ethernet interface |
| Objective Lenses | XLED 2×, XLED 5×, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 4.24 × 3.18 mm (at XLED 2×) |
| Stage Diameter | Ø100 mm |
| Height Adjustment | Manual lead-screw drive |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Interfaces | 1× front USB, 4× rear USB, 2× RJ45 Ethernet, 1× DisplayPort |
| Weight | 132 kg |
| Compliance | ASTM E10, E92, E18 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 / 3000 CS/C EVO |
| Test Force Range | QNESS 250 CS: 1–250 kg (9.81–2450 N) |
| QNESS 750 CS | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 CS | 0.3–3000 kg (2.94–29430 N) |
| QNESS 250 C | 1–250 kg (9.81–2450 N) |
| QNESS 750 C | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 C | 0.3–3000 kg (2.94–29430 N) |
| Test Height | C version: 395 mm |
| CS version | 175 mm |
| Throat Depth | 220 mm |
| Anvil Diameter | Ø100 mm |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial Ethernet camera, up to 270 FPS |
| Objective Lenses | XLED 1, XLED 2, XLED 5, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 7.98 × 5.97 mm (at XLED 1) |
| Display | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~480 W |
| Weight | QNESS 250/750 CS: 250 kg |
| QNESS 3000 CS & all C versions | 300 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 E EVO / QNESS 750 E EVO / QNESS 3000 E EVO |
| Test Force Range | QNESS 250 E EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 E EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 E | 0.3–3000 kgf (2.94–29,430 N) |
| Maximum Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight Capacity | ≤ 3500 kg |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial camera, Ethernet interface, up to 270 fps |
| Optical Magnification | XLED 1 to 100× (FOV: 0.113 × 0.084 mm at 100× up to 7.98 × 5.97 mm at XLED 1) |
| Control Interface | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT Enterprise |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~1230 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 M EVO / QNESS 750 M EVO / QNESS 3000 M EVO |
| Testing Force Range | QNESS 250 M EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 M EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 M EVO | 0.3–3000 kgf (2.94–29430 N) |
| Max Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight | 490 kg |
| Imaging | 5 MP industrial Ethernet camera, up to 270 fps |
| Turret | 2-position standard or 8-position optional |
| Software | Qpix T2 (optional Qpix CONTROL 2 M) |
| OS | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max Power Consumption | ~480 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 CA/CA+ EVO |
| Test Force Range | QNESS 250 CA EVO: 1–250 kg (9.81–2450 N) |
| QNESS 750 CA EVO | 0.3–750 kg (2.94–7358 N) |
| Test Height / Throat Depth | 250 / 220 mm |
| XY Motorized Stage Travel | X 260 mm / Y 266 mm |
| Max. Specimen Weight | 100 kg |
| Host Weight | 320 kg |
| Power Supply | 110–230 V~, 50–60 Hz, 1/N/PE |
| Max. Power Consumption | ~480 W |
| Software | Qpix Control2 |
| Camera | 5 MP Panoramic Imaging (CA+ only) |
| Supported Hardness Methods | Brinell, Vickers, Rockwell, Knoop, Polymer, Carbon Brush Testing |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 A/A+, QNESS 750 A/A+, QNESS 3000 A/A+ EVO |
| Test Force Range | QNESS 250 A/A+: 1–250 kgf (9.81–2450 N) |
| QNESS 750 A/A+ | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 A/A+ | 0.3–3000 kgf (2.94–29430 N) |
| Test Height Adjustment | Motorized asynchronous Z-axis, up to 3200 kg clamping force |
| Throat Depth / Max Vertical Clearance | 362 mm / 320 mm |
| XY Stage Travel | X 460 mm × Y 350 mm |
| Stage Size | 450 × 297 mm (motorized cross-slide) |
| Imaging System | 5 MP panoramic camera (A+ models only) |
| Software | Qpix Control2 with 3D UI, Ethernet interface (RJ45) |
| Compliance | Designed for ASTM E10, E18, E92, E384, ISO 6506, ISO 6507, ISO 6508, ISO 20422, and EN ISO 1463 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 250/750/3000 EVO |
| Instrument Type | Universal Hardness Tester |
| Load Range (Q250) | 1–250 kgf (9.8–2450 N) |
| Load Range (Q750) | 0.3–750 kgf (2.94–7358 N) |
| Load Range (Q3000) | 0.3–3000 kgf (2.94–29430 N) |
| Test Height | 175–510 mm |
| Throat Depth | 220–320 mm |
| Max Specimen Weight | ≤3500 kg |
| Imaging System | 5 MP CMOS camera with Ethernet interface |
| Display | 12″ capacitive touchscreen |
| Loading Control | Electromechanical, closed-loop force feedback |
| Illumination | XLED optical module for Brinell impression analysis |
| Turret | Manual 2-position or optional motorized 8-position auto-turret |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 A/A+ EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.25 g – 62.5 kgf |
| Indenter | ASTM- and DAkkS-certified Vickers diamond |
| Turret | 8-position motorized |
| Illumination | White LED with electric iris shutter |
| Software | Qpix Control2 with intuitive 3D control interface |
| Positioning System | Direct-read linear encoders on X/Y/Z axes (0.5 µm resolution) |
| Optional Feature (A+ only) | Panoramic camera with automated image acquisition (49 × 37 mm field of view) |
| Microstructural Analysis Module | INSPECT (modularly licensable) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 M EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.00245 N – 613.1 N (0.25 g – 62.5 kg) |
| Test Space (Height/Throat Depth) | 145 mm / 170 mm |
| Stage Options | Manual Cross-Slide XY Stage (135 × 135 mm) or Standard Ø100 mm Anvil |
| X/Y Travel | 150 mm × 150 mm |
| Z-Travel | 145 mm |
| Max. Specimen Weight | 50 kg |
| Host Weight | 55 kg |
| Power Supply | 100–240 V, ~1/N/P, 45–65 Hz |
| Software | Qpix Control2 M with INSPECT metallographic analysis module |
| Test Methods Supported | Vickers, Knoop, Brinell |
| Turret | 8-position motorized, configurable with up to 3 hardness modules and 6 objective lenses |
| Illumination | White LED with motorized iris shutter |
| Imaging | High-resolution color camera integrated into optical path |
| Compliance | ASTM E384, ISO 6507, ISO 6508, EN ISO 14978, DAkkS-accredited Vickers diamond indenter included |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS CHD MASTER+ |
| Hardness Testing Methods | Vickers, Knoop, Brinell |
| Test Load Range | 0.49 – 98.1 N (50 g – 10 kgf) |
| Turret | 6-position, motorized |
| X/Y/Z Travel | 150 × 150 × 145 mm |
| Specimen Weight Capacity | ≤ 50 kg |
| Host Weight | 58 kg |
| Camera System | 5 MP color CMOS |
| Positioning Repeatability | ±3.5 µm |
| Interface | 1× USB 3.0 (hardness tester–PC), optional QDAS/PCI/AMS/REMOTE modules |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~200 W |
| Objective Lenses | 4×, 20×, 40× |
| Certified Vickers Indenters | DakkS-accredited |
| Sample Holders | CHD Master+: single-position (Ø30/40/50 mm), quad-position (Ø30/40/50 mm), octo-position (Ø30/40 mm) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QBJ |
| Pricing | Available Upon Request |
| Punch Diameter | 20 mm |
| Maximum Indentation Depth | 10 mm |
| Indentation Resolution | 0.05 mm |
| Digital Depth Display | 0.01 mm resolution |
| Specimen Size | 70 mm × 70 mm |
| Specimen Thickness Range | 0.30–1.25 mm |
| Substrate Material | Polished Steel Plate per GB/T 9271 |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Asia-Pacific |
| Model | QC-508M1 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Electromechanical Tensile Tester |
| Max Test Load | 10–50 kN |
| Load Cell Capacity | 50 kN Full Scale |
| Force Accuracy | ±0.01% FS |
| Test Stroke | 700 mm (standard) / up to 800 mm (with extended configuration) |
| Displacement Resolution | 0.001 mm |
| Speed Range | 0.03–1000 mm/min |
| Data Acquisition Rate | 100 Hz |
| Compliance | ISO 7500-1, ASTM E4, ASTM D76, DIN 51221, JIS B7721/B7733, EN 10002-2, BS 1610, GB/T 228.1 |
| Key | Origin: Jilin, China |
|---|---|
| Manufacturer Type | Distributor |
| Model | QC-I |
| Quotation | Upon Request |
| Pressure Range | 1–100 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.5% F.S. |
| Water Tank Volume | 2.4 m³ (2400 × 1000 × 1000 mm) |
| Fixture Dimensions | 2200 × 900 mm |
| Lift Stroke | 1000 mm |
| Max. Test Object | Metallic tank ≤ 2000 × 872 × 700 mm |
| Rated Capacity | 1.22 m³ |
| Power Supply | 380 V AC, 5 kW |
| Weight | 1000 kg |
| Overall Dimensions | 2600 × 1600 × 2000 mm |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-III |
| Pricing | Available Upon Request |
| Vibration Axes | Z (vertical), X & Y (horizontal, sequential) |
| Max. Acceleration | 30 m/s² (adjustable) |
| Frequency Range | 1–35 Hz (programmable) |
| Amplitude Range | 0.1–5 mm (frequency-dependent, programmable) |
| Test Duration | Z-axis: 4 h |
| X-axis | 2 h |
| Y-axis | 2 h (independently configurable) |
| Fill Level | Up to 50% of rated capacity (configurable) |
| Pressure Monitoring | 0–30 kPa / 0–80 kPa dual-range, ±0.5% FS |
| Temperature Sensing | 0–100 °C, ±1 °C accuracy |
| Time Control Resolution | 1 s |
| Compliance Support | ASTM D471, ISO 16750-3, SAE J1739, GB/T 28046.3 |
| Brand | QDLaser |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | QVFM Series |
| Pricing | Upon Request |
| Laser Wavelength Options | 405–1064 nm (1–3 wavelengths selectable) |
| Resolution | 720p @ 60 fps (input source) |
| Field of View | 39° (H) × 23° (V) |
| Focus | Autofocus-free (fixed-focus optical design) |
| Scan Modes | Raster and vector scanning |
| Power Consumption | Peak 6.5 W, typical <5.5 W |
| Dimensions | 52.00 × 38.40 × 16.75 mm |
| Laser Packaging | TO-38 or TO-56 hermetic can |
| Output Power Range | 7–220 mW (model-dependent, CW) |
| Primary Applications | 3D machine vision, LiDAR sensing, retinal projection, industrial defect detection, biomedical instrumentation, automotive ADAS components, micro-display systems |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | QHZ |
| Pricing | Upon Request |
| Standards | GB/T 9279–1988, ISO 1518:1973, ISO 1518–1997 |
| Scratch Length | ≥60 mm |
| Traverse Speed | 30–40 mm/s |
| Indenter | 1 mm diameter hardened steel ball |
| Load Range | 0–2000 g |
| Dimensions (L×W×H) | 300 × 200 × 300 mm |